Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Endo GIA Curved Tip Articulating Reload tape for cutting and anastomosis with Tri-Staple technology in all sizes |
12 |
Female |
- Material: 48 titanium pins
- Size: length 30mm, pin height 2.0mm- 2.5mm- 3.0mm.
- I-shaped bar design
- Technical characteristics: - Curved endoscopic stapler has 3 rows of different height staples on each side, staple height from inside to outside is: 2.0mm; 2.5mm; 3.0mm. Staple height when closed: 0.75mm;1.0mm;1.5mm.
- Fixed anvil bar
- Standard B-shaped staples, Tri-Staple technology, target tissue closure range 0.88mm - 1.5mm.
-Compatible with straight laparoscopic surgery suture tools with reusable battery and same brand
- Standards: ISO, CE, CFG |
Tra Vinh General Hospital |
|||
2 |
Endoscopic stapler with tristaple technology has 3 rows of staples of different heights on each side, staple height from inside to outside is: 3.0mm; 3.5mm; 4.0mm, staple length 45mm. |
24 |
Female |
- Material: 66 titanium pins
- Dimensions: length 45mm, pin height 3.0mm- 3.5mm- 4.0mm.
- I-shaped bar design
- Technical characteristics: - Laparoscopic stapler has 3 rows of different height staples on each side, staple height from inside to outside is: 3.0mm; 3.5mm; 4.0mm. Staple height when closed: 1.25mm; 1.5mm; 1.75mm.
- Fixed anvil bar
- Standard B-shaped staples, Tri-Staple technology, target tissue closure range 1.5mm - 2.25mm.
-Compatible with straight laparoscopic surgery suture tools with reusable battery and same brand
- Standards: ISO, CE, CFG |
Tra Vinh General Hospital |
|||
3 |
TristaLle technology endoscopy has 3 different height pins on each side, the height pin from the inside out is: 3.0mm; 3.5mm; 4.0mm, 60mm pin length. |
48 |
Female |
- Material: 90 titanium pins
- Size: length 60mm, pin height 3.0mm- 3.5mm- 4.0mm.
-I-shaped bar design
- Technical characteristics: - Laparoscopic stapler has 3 rows of staples of different heights on each side, staple height from inside to outside is: 3.0mm; 3.5mm; 4.0mm. Staple height when closed: 1.25mm; 1.5mm; 1.75mm.
- Fixed anvil bar
- Standard B-shaped staples, Tri-Staple technology, target tissue closure range 1.5mm - 2.25mm.
- Cutting pin length greater than or equal to 55mm
-Compatible with straight laparoscopic surgery suture tools with reusable battery and same brand
- Standards: ISO, CE, CFG |
Tra Vinh General Hospital |
|||
4 |
Ball pump set |
500 |
Female |
Balloon pump set: can handle high pressure, volume 20ml, pressure 30atm
- Material made of Polycarbonate
- Attached accessories: Hemostatic valve, insertion device, torque, 3-way lock, extension tubing, prime lock, etc. FDA standards |
Tra Vinh General Hospital |
|||
5 |
Ball pump set |
500 |
Set |
Material: Polycarbonate. Pressure gauge material: Brass Nylon. Fluorescent watch face allows viewing in dark conditions, pressure release lock lever, pressure connection cord with 360 degree swivel lock, Detachable. Maximum pressure 30 Atm, Volume 25 ml. Comes with Y-valve for hemostatic combination opening and closing, large diameter 10Fr, guide wire driver, pusher. Manufacturer standards: ISO, CE. Origin: G7 |
Tra Vinh General Hospital |
|||
6 |
High pressure balloon pump set with three pin, Y-shaped connector |
30 |
Female |
Polycarbonate material. Pressure 30 atm. Capacity: 25 ml. FDA standards. |
Tra Vinh General Hospital |
|||
7 |
Set of steel threads to close the sternum |
5 |
Set |
*Steel thread set for sternum No. 7
* Stainless steel material, suitable needle size for sternum closure and abdominal wall surgery |
Tra Vinh General Hospital |
|||
8 |
3-round foreign object catching kit |
2 |
Female |
Set includes: Three Nitinol cables twisted together, There is a Platinum strip tightly linked to the Loops to increase recognition. Super elastic Nitinol wire is flexible and has good torsion resistance. Working sizes 6-10mm, 9-15mm, 12-20mm,... Catheter length 100cm, Snare length 120cm. FDA standards |
Tra Vinh General Hospital |
|||
9 |
Set of tools to help open access to blood vessels of all sizes |
100 |
Set |
The set of tools to open access to the radial and femoral vessels includes: Vascular dilation tube (Dilator); Sheath introducer, Mini guidewire, Vascular puncture needle, Dimensions: 5 F; 6F; 7F; 8F; 9F, Length: 11 cm |
Tra Vinh General Hospital |
|||
10 |
Thrombotic suction kit |
20 |
Female |
Thrombectomy kit: with interwoven fiber structure, stylet shaft design Radiopaque marking at the distal end, shaft length 140cm, tip length 6mm, hydrophilic coating ≥ 40cm long. Size: 6F. Inner diameter 1.00mm and distal lumen area is 0.78 mm², included tools: 30ml syringe with lock, connecting wire with lock 2 pm, washing equipment, 70µm filter membrane |
Tra Vinh General Hospital |
|||
11 |
Thrombotic suction kit |
20 |
Female |
Thrombectomy kit size 6F. 5.2F catheter with a maximum outside diameter of 0.068''. Has a stainless steel braided border. Tapered tip. Used for blood vessels with diameter ≥2.0mm. Catheter length: 140 cm. The hydrophilic segment is 20cm long. Markers made of Platinum / Iridium material. Minimum compatible guiding catheter inner diameter: 0.070". Compatible guide wire: 0.014". There is a 12 cm long Rapid Exchange head to guide the 0.014" guide wire. Supplied with: 2 30 ml suction syringes, 1 4 ml flushing syringe, 1 coagulation and storage tray holding up to 60 ml of solution and 2 70 micron filters, 1 tubing: 21.5 cm with stopcock lock. Meets FDA standards. |
Tra Vinh General Hospital |
|||
12 |
Vascular opening kit, |
1.000 |
Set |
Description: Arterial access opening kit includes: guide wire 0.025", 0.035" long ≥ 45cm, angioplasty needle 18G or 20G, syringe ≥ 2.5ml, Introducer sheath, dilation rod, skin incision knife, etc.
Size: Diameter 4Fr to 8Fr, length 7cm-10cm.
Technical standards: cross-cut hemostatic valve, Dilator made of polypropylene, Sheath made of ETFE |
Tra Vinh General Hospital |
|||
13 |
Radial artery access kit |
400 |
Female |
Radial artery access tool Material: Polyethylene and polypropylene, Hemostasis valve prevents blood leakage, Size: 4Fr to 6Fr, length 7cm-11cm depending on diameter, guide wire made of stainless steel, diameter 0.018" - 0.038", length 40cm -50cm, Angiography needle 18G x 7cm or 21G x 4cm, Lock 3 fall..Origin: countries in the bloc G7 |
Tra Vinh General Hospital |
|||
14 |
Disposable vein stripping kit |
10 |
Set |
Steel wire piece coated with tetrafluoroethylene/hexafluoropropylene (FEP) copolymer
Handle
Three (03) cutting heads with diameters of 9, 12 and 15 mm
One (01) screw cap to attach the cutting heads
Standards: ISO, CE, FDA |
Tra Vinh General Hospital |
|||
15 |
3-Door Manifold Connector |
700 |
Female |
3-port Manifold, Poly Carbonate material. Inner diameter 0.093"
There are 3 ports suitable for different uses, with rotating luer and rotating air discharge head. Withstands pressure of 200, 500 PSI (depending on product code), FDA standards |
Tra Vinh General Hospital |
|||
16 |
1 chamber pacemaker |
10 |
Female |
IS-1 connection standard. MRI mode can be activated and deactivated using the handheld device. An MRI scan can be performed immediately after implantation.
The AutoCapture pacing system allows for maximum response to pacing thresholds with the ability to confirm beat-by-beat pacing leads. The AutoCapture pacing system automatically generates a 5V backup pulse when conduction loss is detected, and can be programmed as either unipolar or bipolar. Stores the electrocardiogram inside the heart chamber for up to 14 minutes. |
Tra Vinh General Hospital |
|||
17 |
2 chamber pacemaker |
20 |
Female |
Creates a dual-chamber pacemaker with rhythm response to movement. Allows 3T full-body MRI scan - no limit on scan time or patient height. Manages atrial and ventricular pacing, allowing programming of safe pacing amplitudes up to 4 times the pacing threshold. There is a function to suggest parameters to help program the machine appropriately for each patient. The frequency response to the magnet when the battery is remaining is 85 cycles/minute. Battery life up to 14.9 years. |
Tra Vinh General Hospital |
|||
18 |
2 chamber pacemaker |
20 |
Set |
IS-1 connection standard. MRI mode can be activated and deactivated using the handheld device. An MRI scan can be performed immediately after implantation. The AutoCapture pacing system allows for maximum response to pacing thresholds with the ability to confirm beat-by-beat pacing leads. The AutoCapture pacing system automatically generates a 5V backup pulse when conduction loss is detected, and can be programmed as either unipolar or bipolar.
Automatic feature set, Intrinsic Ventricular Conduction Priority, AF Suppression - Pacing to suppress atrial fibrillation and SenseAbility - Automatic sensing. There is a programmable atrial tachyarrhythmia alarm. Stores the electrocardiogram inside the heart chamber for up to 14 minutes |
Tra Vinh General Hospital |
|||
19 |
HERA Manifold Dispenser |
700 |
Female |
3-port Manifold, 360 degree rotation, Luer male head for quick and accurate connection, transparent design can observe flow rate accurately
-Poly Carbonate material. There is an opening and closing valve, maximum pressure of 500psi |
Tra Vinh General Hospital |
|||
20 |
Hemostatic valve set has 02/03 connection ports with 30 and 40 degree angles (Y-Connector) |
50 |
Set |
There are 2 types: 02 and 03 ports, Length: 54, 80 and 78 mm, Angled ports: 30 and 40 degrees, Size: 9 Fr, Minimizes blood loss and retrograde bleeding, Material: Polycarbonate, Product set includes: 1 valve, 1 torque and 1 needle. Quality standards: ISO |
Tra Vinh General Hospital |
|||
21 |
10ml syringe with luerlock tip used in vascular intervention |
1.400 |
Female |
10ml syringe with luerlock tip used in vascular intervention, material made of Poly carbonate, good pressure resistance, easy to see the flow and air bubbles inside, Fixxel male luer vortex tip Meets FDA standards. |
Tra Vinh General Hospital |
|||
22 |
3ml syringe with luerlock tip used in vascular intervention |
500 |
Female |
3ml syringe with luerlock tip used in vascular intervention, material made of Poly carbonate with good pressure resistance, easy to see the flow and air bubbles inside, Fixxel male luer vortex tip Meets FDA standards. |
Tra Vinh General Hospital |
|||
23 |
Aortic retrograde balloon pump, various sizes |
10 |
Pieces |
RX catheter system with 60cm long lumen enhances thrust for distal lesions. Z-Tip technology: tip length from 3 - 5 mm. Coating: Hydro-X (distal segment); Water resistant coating (inner tube), tip enty Profile, : 0.017", Crossing Profile: 0.039". Normal pressure 12 atm. Balloon rupture pressure is up to 22atm. Compatible wire: 0.014 inch. Balloon diameter from 1.5 - 6 mm. Balloon length from 15 - 240 mm. Tube length: 150 cm. Quality standards: ISO, CE. Origin: Europe |
Tra Vinh General Hospital |
|||
24 |
Aortic counterpulsation balloon 7.5Fr |
10 |
Female |
Material: Polyurethane, Size: 7Fr, 8Fr, 9Fr, Balloon volume 30cc, 40cc, 50cc Center lumen diameter 0.027", Cardiothane II balloon membrane, Hydrophilic coating. Guidewire: 0.025", membrane length: 9.1", 10.2", 10.3'', balloon inflation size: 14mm, 15mm, 16mm |
Tra Vinh General Hospital |
|||
25 |
Peripheral vascular intervention dilation balloon, diameter 3-12mm, length 20-300mm |
2 |
Female |
Peripheral angioplasty balloon. The ball uses guide wire 0.035. Compatible with 5F or 6F or 7F sheath. Dual Lumen tube design: Radiopaque marker: has 2 markers made of Platinum Iridium with injection molding technology (swaged -> zero profile). The ball has 6 folds, ball material: Flexitec Xtreme. The ball has a hydrophilic coating. |
Tra Vinh General Hospital |
|||
26 |
Vascular intervention dilation balloon, diameter: 1.5mm-4mm, length: 20mm-220mm, system: 0.014". |
5 |
Female |
System Design: Over The Wire.
Ball type: Controlled Compliance (3-sided stacking technique).
Ball material: SCP (Semi-Crystalline Polymer).
Coating: Hydrophilic.
Ball diameter: 1.5mm, 2mm, 2.5mm, 3mm, 3.5mm, 4mm.
Ball length: 20mm, 40mm, 70mm, 100mm, 140mm, 180mm, 220mm.
System length: 90cm, 120cm, 150cm.
Marker: 2 stereotyped markers.
Wiring system: 0.014".
Certified: CFS, ISO. |
Tra Vinh General Hospital |
|||
27 |
Vascular intervention dilation balloon, diameter: 3mm-10mm, length: 20mm-200mm, system: 0.035". |
10 |
Female |
System Design: Over The Wire. Ball shape: Controlled Compliance (5-sided folding technique helps the ball fold smaller).
Ball material: SCP (Semi-Crystalline Polymer).
Coating: Hydrophobic.
Ball diameter: 3mm, 4mm, 5mm, 6mm, 7mm, 8mm, 9mm, 10mm.
Ball length: 20mm, 40mm, 60mm, 80mm, 100mm, 120mm, 150mm, 170mm, 200mm.
System length: 80cm, 90cm, 130cm.
Marker: 2 stereotyped markers.
Maximum pressure: 20atm.
Wiring system: 0.035".
Certified: CFS, ISO. |
Tra Vinh General Hospital |
|||
28 |
Vascular intervention dilation balloon, compatible with 0.018" guidewires |
5 |
Female |
Peripheral angioplasty balloon made of Pebax material with Hydrophilic Bioslide technology, compatible with 0.014"/0.018" guide wire
There are 2 types: monorail and over-the-wire (catheter length 40, 80, 90, 135, 150 cm), comes with guidewire 0.014"/0.018" pressure from 6atm to 14atm, introducer sheath recommended 4F. Pebax ball material, hydrophilic coating on the ball. Diameter: 2.0mm -10.0mm, | length: 10mm - 220mm.. |
Tra Vinh General Hospital |
|||
29 |
Hot can balls
vascular card, diameter: 2mm-7mm, length: 20mm-
200mm, system
System: 0.018". |
10 |
Female |
System Design: Over The Wire.
Ball shape: Controlled Compliance (5-sided folding technique helps the ball fold smaller).
Ball material: SCP (Semi-Crystalline Polymer).
Coating: Hydrophobic.
Ball diameter: 2mm, 2.5mm, 3mm, 3.5mm, 4mm, 5mm, 6mm, 7mm.
Ball length: 20mm, 40mm, 60mm, 80mm, 120mm, 150mm, 170mm, 200mm.
System length: 90cm, 130cm, 150cm.
Marker: 2 stereotyped markers.
Wiring system: 0.018".
Certified: CFS, ISO. |
Tra Vinh General Hospital |
|||
30 |
Balloon angioplasty of femoral, below knee, popliteal, radius and humerus, balloon diameter 12-18mm |
5 |
Female |
System Design: Over The Wire.
Ball shape: Non-Compliant (4-sided folding technique helps the ball fold smaller).
Ball material: Co-Extruded.
Coating: Hydrophilic Medi-Glide.
Ball diameter: 12mm, 14mm, 16mm, 18mm.
Ball length: 20mm, 40mm, 60mm. Body shaft length: 75cm, 120cm.
Compatible conductor: 0.035".
Maximum pressure: 8atm.
Entry profile: 0.037".
Certified: ISO.. |
Tra Vinh General Hospital |
|||
31 |
Peripheral artery ball |
5 |
Female |
Ball 0.035", Flexitec ball material
- Sizes 3,4,5,6,7,8,9,10mm, length 20,40,60,80,120,150, 200,250, 300mm. Especially with size 12x20.40mm. Guide 5F-7F.
- Unique with a length of up to 300mm, suitable for treating long lesions.
- Soft ball, low profile but achieves high pressure of 11-12-14-15-16-17-18 bar.
- Catheter system length 80cm and 130cm
- Quality standards: ISO, CE. |
Tra Vinh General Hospital |
|||
32 |
Peripheral artery ball |
5 |
Female |
High pressure peripheral angioplasty balloon 12,14,16,18, 19,20, 23,24 bar
- Shelves 4,5,6,7,8,9,10, 12mm are 20,40,80,100mm long.
- Catheter system length 40cm, 80cm and 135cm."
- Quality standards: ISO, FDA. |
Tra Vinh General Hospital |
|||
33 |
24atm high pressure peripheral angioplasty balloon, compatible with 0.035" guide wire |
5 |
Female |
High pressure peripheral angioplasty balloon, Nybax material, coated with Medi-glide lubricant. Input to lesion location: 0.040" (1.016mm).
Diameter: 3mm - 12mm, length: 20mm - 200mm. Compatible with 0.035" wire, maximum pressure 24atm.
There are 2 bands marked with Platinum Iridium.. |
Tra Vinh General Hospital |
|||
34 |
High pressure peripheral angioplasty balloon, diameter 4-12mm |
5 |
Female |
High pressure peripheral balloon dilation. The ball uses a 0.035" guide wire. Compatible with 6F, or 7F sheath. Ball burst pressure is up to 24atm. |
Tra Vinh General Hospital |
|||
35 |
Paclitaxel coated angioplasty balloon, coating density: 3µg/mm², diameter:
2mm-7mm, length: 40mm-120mm, system: 0.018". |
2 |
Female |
Drug coating: Paclitaxcel (anti-proliferative) and butyryl-tri-hexyl citrate (BTHC) with Lux coating technology helps increase the efficiency of drug release into blood vessels, with a coating density of 3µg/mm².
Ball diameter: 2mm, 2.5mm, 3mm, 4mm, 5mm, 6mm, 7mm.
Ball length: 40mm, 80mm, 120mm.
System length: 90cm, 130cm, 150cm.
Marker: 2 stereotyped markers.
Wiring system: 0.018".
Certified: CFS, ISO. |
Tra Vinh General Hospital |
|||
36 |
High pressure a coronary heat |
150 |
Female |
High-pressure angioplasty balloon, made of non-expandable material, with Bi-Segment balloon carrier system. Hydrophilic coating reduces friction on the catheter body. Super small tip profile: 0.017", small Crossing profile: 0.031". . Ball diameter: 2.00mm, 6.00mm, Ball length: 6mm- 30mm, Maker made of Platinum. The product has CE and FDA certificates. |
Tra Vinh General Hospital |
|||
37 |
High pressure a coronary heat |
150 |
Female |
High pressure angioplasty balloon. Diameter from 2.0mm to 4.5mm, length from 8mm to 25mm. Material: Nylon 12. Coating: hydrophilic up to 50cm on tube body 3-fold design, 30° conical ball tip design. Compatible with 0.014" guide wire and 5F catheter. Quality standards: ISO, CE |
Tra Vinh General Hospital |
|||
38 |
High pressure a coronary heat |
150 |
Box/pieces |
2 layers of Hydrophilic ultrasonic coating on the outside and inside, 3-fold Nylon ball, Hypotube body design, Tip profile 0.016'', Two markers made of Pt/Ir material, Diameter: 2.0mm - 5.0 mm. Length: 6mm - 30mm, NP: 12atm; RBP: 22atm (2.0-4.0mm), 20atm (4.5-5.0mm), Standard: ISO 13485, CE. |
Tra Vinh General Hospital |
|||
39 |
High pressure a coronary heat |
150 |
Female |
Compact ball design Z-tip technology with tapered tip, Nylon material. Ball body diameter 0.0336 inch, tip penetration cross section 0.0172 inch. Hydrophilic coating Hydro-X. Ball diameter: 1.75 – 5 mm. Ball length: 8 – 18 mm. Normal pressure is 12 atm, balloon burst pressure is 18 atm - 20 atm. Usable length of catheter 140cm. Number of balloon folds: 3- 5, Origin: European countries |
Tra Vinh General Hospital |
|||
40 |
Polyamide high pressure angioplasty balloon |
150 |
Female |
Material: Polyamide, hydrophilic coating, radiopaque marked at both ends. Marker length 1.00mm, bell-shaped ball shoulder. Catheter length 143cm, proximal outer diameter 2.1F/0.69mm. Distal tip outer diameter: 2.45F/0.81mm, 2.5F/0.83mm, 2.6F/0.86mm, With depth markers 90cm and 100cm from the tip. Tip diameter 0.016 inch, compatible with 0.014 inch wire. Ball diameter from 2.50 - 4.5mm, ball length 8mm-15mm. Normal pressure is 12 Atm, balloon burst pressure is from 20 atm to 23 atm depending on diameter. Quality standards: ISO, Origin: G7 countries |
Tra Vinh General Hospital |
|||
41 |
Normal pressure a coronary pressure |
150 |
Female |
Expandable angioplasty balloon made of OptiLEAP material, coated with Zglide hydrophilic layer with Bi-Segment balloon carrier system. Size: diameter: 1.2-4.0mm; Length: 8-30mm. Super small tip profile: 0.017", small Crossing profile: 0.026",. Maker made of Platinum. The product has CE and FDA certificates. |
Tra Vinh General Hospital |
|||
42 |
Normal pressure a coronary pressure |
150 |
Female |
Used to dilate narrow segments of coronary arteries or bypass stenoses, Polyether block amide balloon material, Rapid Exchange design, semi-elastic balloon type, radiopaque marked with Platinum - Iridium material, 1.0mm long, super hydrophilic coating, Catheter length 143cm, . Crossing profile (3.0mm) 0.84mm. Tip diameter 0.39mm (0.015 inch). Normal pressure 6Atm, Ball burst pressure 14Atm. Standard: ISO 13485, Origin: G7 countries |
Tra Vinh General Hospital |
|||
43 |
Normal pressure a coronary pressure |
150 |
Female |
Nylon material. Balloon body diameter 0.0216" - 0.0306", penetration cross section 0.0164". Hydrophilic coating. Balloon diameter: 1 - 4 mm. Balloon length: 5 - 30 mm. Normal pressure 6atm, balloon rupture pressure 14 atm - 16atm Available length of catheter: 140 cm. Number of balloon folds: 2-3.. Origin: Europe |
Tra Vinh General Hospital |
|||
44 |
Normal pressure a coronary pressure |
150 |
Female |
Ball material: Grilamid L25. Ball head material: Pebax, 2 gold oil markers. Proximal body: AISI 304 coated stainless steel. Distal body: 3-layer polyamide combined body with reinforced inner lumen. Hydrophilic coating. Inlet size: 0.0158". Normal pressure (NP): 8 atm. Balloon burst pressure (RBP): 16 atm |
Tra Vinh General Hospital |
|||
45 |
Normal pressure a coronary pressure |
150 |
Box/pieces |
2 layers of Hydrophilic ultrasonic coating on the outside and inside, Property pebax material ball with 2 folds, 3 folds, Hypotube body, Tip profile 0.016'', Two markers in Pt/Ir, Diameter: 1.0 mm - 4.0 mm. Length: 5mm - 30 mm, NP: 6 atm; RBP: 14atm, Standard: ISO 13485, CE. |
Tra Vinh General Hospital |
|||
46 |
Coronent coronary ball has a knife |
10 |
Female |
The knife-shaped coronary intervention dilation balloon has a hydrophilic coating. The balloon has 3 or 4 stainless steel blades mounted along the outside surface of the balloon. Blade height 0.005'', blade length 8mm, Balloon diameter: 2.00mm -4.00mm, Platinum Irridium marker material 1mm, Damage contact diameter 0.017 inch, Balloon length: 6mm- 15mm, Nominal pressure 6atm, Balloon rupture pressure 12atm. CE, FDA standard standards |
Tra Vinh General Hospital |
|||
47 |
Peripheral dilation balloon made of Nybax material, diameter 1.5-4mm, length 20-220mm, compatible with 0.014" guide wire |
5 |
Female |
Small-sized peripheral angioplasty balloon, Nybax material coated with hydrophilic Bioslide technology. “3 fold” design. Includes 2mm Platinum Iridium markers.
Input to lesion site 0.017". Maximum pressure 14atm. Compatible wire 0.014". Diameter: 1.5mm - 4.0mm. Length: 40mm -220mm. Catheters come in two forms: monorail and OTW with lengths of 90cm and 150cm. |
Tra Vinh General Hospital |
|||
48 |
Peripheral dilation balloon coated with 3.5mg/mm2 drug, compatible with 0.035" guide wire |
2 |
Female |
Special drug coating and drug release technology FreePAC, optimizes drug release time (30-60"). Flexitec xtreme ball material with 6 folds, Hydrophilic balance technique (lubrication, Urea conductor helps effectively control the drug release process. Ball uses Introducer sheath 5F or 6F, compatible with 0.035" wire - Ball has 2 markers. |
Tra Vinh General Hospital |
|||
49 |
45 MHZ mechanical IVUS ultrasound probe |
10 |
Female |
Ultrasound probe with mechanical rotation mechanism at high frequency up to 45Mhz, with hydrophilic coating to enhance propulsion and control ability, probe 20.5mm from the tip, length of wire running in the shaft 15.5mm from the tip, radial diameter through the near and far body 3.0F, middle body 3.1F, effective length 135cm. |
Tra Vinh General Hospital |
|||
50 |
Coronary and peripheral ultrasound probe |
10 |
Female |
Coronary and peripheral ultrasound probe. The probe is soft and pointed, with an outer diameter of 0.019" to help easily enter stents and clean difficult wounds. The distal shaft has a hydrophilic coating of ≥24cm, a useful length of 150cm, and has software that displays images of blood flow in the vessel, helping to evaluate the size of the vessel lumen and the degree of pressure on the vessel wall of the stent. |
Tra Vinh General Hospital |
|||
51 |
Y-type Y-Star connector |
200 |
Set |
Y-Star connector is a press and screw type, valve inner diameter 9Fr, used in diagnostic imaging and vascular intervention procedures with a flexible connection port that helps attach additional connections for maximum support during surgery.
Y-connector set includes: Y-connector, Torque, Needle 10cm long, Transmission line with luer lock has 03 ports, 25cm long, 02 flexible connection ports |
Tra Vinh General Hospital |
|||
52 |
Male/male connector |
700 |
Female |
Male-male/female-female connector Material: Transparent polyethylene used to connect to high pressure measuring wire or infusion line during vascular intervention. |
Tra Vinh General Hospital |
|||
53 |
Intervention wire (micro wire) used for CTO technique |
30 |
Female |
Multi-core conductor with ACT ONE technology (double helix design) increases tip durability, torque response and shock resistance.
One-piece core single conductor.
Tip load from 0.3 - 20 gf provides very good support for medical intervention cases.
Coating: silicone, SLIP-COAT or SLIP-COAT on polymer base.
Tip: straight, J, pre-shaped.
Length: 180, 190, 300cm/330cm (RG3).
Quality certification: ISO, CE. |
Tra Vinh General Hospital |
|||
54 |
Soft interference conductor (microconductor). |
30 |
Female |
Multi-core conductor with ACT ONE technology (double helix design) increases tip durability, torque response and shock resistance. One-piece core single conductor.
Coating: silicone or SLIP-COAT.
Tip load: 0.5 gf, 0.7gf, 0.8 gf.
Tip: straight, J.
Diameter: 0.014 inches. Length: 180 cm / 150, 165 cm (extension wire).
Quality certification: ISO, CE. |
Tra Vinh General Hospital |
|||
55 |
Wires (microwires) provide peripheral intervention |
20 |
Female |
The wire has tip load from 1.0 g to 40 g, pointed or magnetic tip
- Wire diameter 0.014inch, 0.018inch
- One-piece core single conductor.
- Multi-core conductor using ACT ONE technology increases torque transmission capacity and high tip durability, length 200cm, 235cm, 300cm
- Coating: hydrophilic/hydrophilic on polymer base.
- Quality standards: ISO, CE |
Tra Vinh General Hospital |
|||
56 |
Hydrophilic coated vascular intervention guide wire diameter: 0.035" |
50 |
Female |
Vascular intervention guide wire coated with hydrophilic layer: Structure: Nitinol, Diameter: 0.035" length: 45cm - 180cm., There are 06 different tip types: Angled; Straight; 1.5J; 2.0J; 3.0J; Beak. |
Tra Vinh General Hospital |
|||
57 |
Brain intervention wire with double helix structure |
20 |
Female |
ACTONE technology with double helix structure maintains tip shape, good torque response. SLIP-COAT, SLIP-COAT coating on polymer base 170cm -180cm long. Diameter: 0.008 inch -0.018 inch Available length: 200cm, 300cm. Tips: straight, round curver, angled. Quality standards: ISO, CE |
Tra Vinh General Hospital |
|||
58 |
Coronary intervention conductor |
100 |
Pieces/ yarn |
1. Materials: Durasteel base material (equivalent or higher), full body polymer coating with hydrophilic layer
2. Size: Diameter: 0.014'', Length: 190cm or 300cm, Tip load: 1.5g; 2.7g; 4.1g. J-curved tip, straight tip, wire tip has radiopaque marker (Marker Band) to help feel the position of the guide wire on the path to the lesion. |
Tra Vinh General Hospital |
|||
59 |
Coronary intervention conductor |
100 |
Pieces/ yarn |
Materials: Distal core made of ELASTINITE NITINOL, proximal core made of stainless steel, coated with durable hydrophilic and hydrophobic coating. Size: Diameter 0.014'', length 190cm or 300cm. J-curved head, straight head, durable, bearing 0.7g. The end of the wire has a radiopaque marker: 1.5mm. |
Tra Vinh General Hospital |
|||
60 |
Runthrough type coronary intervention guide wire |
1.400 |
Female |
Coronary intervention guide wire, diameter 0.014" 180cm long. Length of the distal part with outer coil layer: 25cm, length of the radiopaque tip: 3cm. Materials: Core: Nickel-Titanium, the first part of the outer coil layer is made of Platinum, the back part of the coil layer is stainless steel. Origin: G7 countries |
Tra Vinh General Hospital |
|||
61 |
Neurological intervention leads of all types and sizes |
20 |
Female |
Lead wire for cerebrovascular intervention, . Head diameter is approximately 0.014 inches. Length about ≥200 cm, the distal end has a 5cm long platinum spring coil, 38 cm long hydrophilic coating Material: stainless steel, hydrophilic. Packaging: 1 piece/box |
Tra Vinh General Hospital |
|||
62 |
Diagnostic leads |
30 |
Female |
- 0.035" guide wire with flexible tip, tip load of 6.3 gf & tube body hardness of 3.6 N helps increase thrust. Nitinol core guide wire is easily opaque
operation. Coating the outside of the conductor with a hydrophilic layer.
- Tip shape: 1.5, 3, 6 J, straight, angle.
- Available length: 50 - 180 cm. (Details of sizes) |
Tra Vinh General Hospital |
|||
63 |
Coronary diagnostic guide wire 0.035" |
700 |
Female |
Material ; Stainless steel, Diameter 0.035" long ≥150 cm, Standard: ,ISO |
Tra Vinh General Hospital |
|||
64 |
Coronary diagnostic guide wire sizes from 0.035" to 0.038", |
700 |
Female |
Diameter in many sizes: 0.035" - 0.038". Length: ≥150cm. Core made of stainless steel, coated with PTFE. Standard: FDA |
Tra Vinh General Hospital |
|||
65 |
Hydrophilic coated vascular diagnostic guide wire is 260cm long |
20 |
Female |
Structure: Core is Nitinol material, super elastic alloy., Outer layer is Polyurethane, increased optical resistance with Tungsten layer.. Hydrophilic M coat coating, Head shape: curved tip (Straight, Angled). Dimensions: Lead length: 260 cm, Length of flexible tip: 3 cm, Diameter: 0.035'',.... |
Tra Vinh General Hospital |
|||
66 |
Coronary diagnostic leads of all sizes and hydrophilic types |
200 |
Female |
The core structure is a super-elastic alloy (Nitinol), the polyurethane outer layer is covered with a tungsten layer to increase radiopaque properties. The coronary angiography guide wire is coated with a hydrophilic layer of M Coat. diameter 0.035", curved end, straight end. Length 150cm. length of flexible end: 3cm, |
Tra Vinh General Hospital |
|||
67 |
Angiography guide wire 0.035"-150cm, stainless steel, silicon coated, teflon |
30 |
Female |
- Material: stainless steel, silicon coating, teflon.
- Smooth surface, easy to move inside the catheter as well as the blood vessel.
- High optical resistance, no twisting during operation.
- Diameter 0.035", length 150cm |
Tra Vinh General Hospital |
|||
68 |
Ballooned electrode wires for temporary pacemakers |
30 |
Female |
The woven material is biocompatible, soft at body temperature and adapts to the endocardium. Latex balloon has a volume of up to 1.5 ml, the design of the balloon supports easy wire placement. Optional body size 5F. The first electrode is located at the far end of the electrode wire, the second electrode is about 1cm away from the first electrode. • Comes with needle, syringe, ECG adapter, Safety Adapter. |
Tra Vinh General Hospital |
|||
69 |
Pressure gauges |
1.400 |
Female |
PVC material. The proximal end is a fixed male/female leur, the distal end is a fixed male. Length 30cm, 152cm. FDA standards |
Tra Vinh General Hospital |
|||
70 |
FFR pressure measuring line, CFR flow measuring and IFR micro resistance measuring |
10 |
Female |
Coronary reserve pressure measurement leads IFR and FFR have hydrophilic coating and PTFE coating, probe position 3 cm from the tip, tip load 0.66, straight tip and J shape, effective length 185cm,300cm, diameter 0.014", flexible section length 30cm. |
Tra Vinh General Hospital |
|||
71 |
High pressure wire |
50 |
Female |
Material: Polyurethane, luer lock connection port can withstand pressure up to 1200psi, length 30cm, 120cm |
Tra Vinh General Hospital |
|||
72 |
Temporary pacing electrode with shade |
30 |
Female |
Temporary pacing bipolar wire with type 5F balloon, stainless steel material.
Catheter made of Polyurethane (PUR), flexible, anti-thrombotic, non-toxic, Electrode prevents the formation of strong impulses, pin: 2mm gold-plated. Stimulating electrode 110 cm, Catheter has markers every 10 cm for positioning, electrode length: 5 mm, electrode distance: 10 mm. |
Tra Vinh General Hospital |
|||
73 |
Peripheral circuit protection tools |
5 |
Female |
Material: filter mesh made of Nitinol, Full-Wall mesh weaving technique. The filter mouth has a round frame made of Gold - Tungsten material as a marker
Profile: Conical filter wire attached, with guide and recovery catheter included. The system does not affect the flow during intervention at all. The system is suitable for both 0.014'' and 0.018'' conductors, filter diameter 3,4,5,6,7mm, push wire length 190cm - 320cm. CFS, ISO, CE certificates. |
Tra Vinh General Hospital |
|||
74 |
Endo GIA Ultra Universal automatic anastomosis cutter used in laparoscopic surgery, capable of meeting a 45 degree angle with 5 angled points on each side and one point in the middle. Shaft length 16cm |
10 |
Female |
- Laparoscopic anastomosis suturing tools of all sizes:
- Material: titanium pin
- Dimensions: After installing the compatible staples, it can be folded at a total angle of 90 degrees on both sides, 45 degrees on each side with 5 folding points on each side and one point in the middle. Shaft length 16cm
- Technical characteristics: Multi-purpose endoscopic anastomosis cutting tool, integrated with all types of endoscopic anastomotic cutting staples. types, sizes, TRI-STAPLER TECHNOLOGY
- Compatible with radial curved staples and laparoscopic staplers with reinforced patches.
- Standards: ISO, CE, CFG |
Tra Vinh General Hospital |
|||
75 |
Pulse tools with self -consumption and double hemostatic mechanism |
7 |
Female |
The vascular closure device includes: 01 0.035'' or 0.038'' guide wire 70cm long, 01 dilator, 01 sheath. The vascular closure device uses a dual hemostatic mechanism with anchors inside the vessel and collagen outside the vessel, held by absorbable sutures to help fix the position where the vessel needs to be closed. Parts left in the body are bioabsorbable, absorbed within 60 - 90 minutes. day. Size: 6Fr and 8Fr |
Tra Vinh General Hospital |
|||
76 |
The device opens the way into the radial artery with a hydrophilic layer and an ultra-thin wall |
10 |
Female |
Ultra-thin wall technology reduces the outer diameter of the sheath by 1Fr while still maintaining the same inner diameter as similar sheaths.
Structure:
- Angiography needle size: 20G x 51mm; 22G x 32mm
- Mini guidewire plastic size 0.025" x 45cm; plastic 0.021" x 45cm; spring 0.018" x 45cm;
- 10cm long Sheath coated with M Coat hydrophilic layer
- Size: size 7Fr, 6Fr and 5Fr |
Tra Vinh General Hospital |
|||
77 |
The device opens the way to the radial artery, has a hemostatic valve, and is coated with a hydrophilic layer |
5 |
Female |
Structure includes:
- Threading needle size 20G x 11/4".
- Mini guidewire plastic size 0.025" x 45cm or 0.025" x 80cm
- 2.5ml syringe
- Dilator (dilator)
- Knife cuts the skin
Characteristic:
- "Cross-Cut" style hemostatic valve
- Sheath is coated with M Coat hydrophilic layer, the resistance is only 1/2 that of regular sheath, reducing discomfort for the patient.
- Size: diameter 5F-6F, length 10cm or 16cm |
Tra Vinh General Hospital |
|||
78 |
Lubricating solution reduces friction for atheroma chipping drill bits |
3 |
Female |
Solution used in the atherosclerotic plaque scraping system in blood vessels. Ingredients: Olive oil, phospholipid, egg yolk, sodium deoxycholate, L-histidine, disodium EDTA, sodium hydroxide, water |
Tra Vinh General Hospital |
|||
79 |
Flush device 3ml/hour |
700 |
Female |
Male head rotates
Turn lock OFF, pressure 250 psi
Speed 3ml/h. |
Tra Vinh General Hospital |
|||
80 |
Neurological circuit holder |
20 |
Female |
Material: Nitinol, Size: Stent diameter 3mm - 6mm, stent length 20mm - 40mm for vessels with diameters of 1.5-3mm, 1.5-4mm, 2-5.5mm
The cerebral thrombosis removal stent has an open structure, parametric folding design, self-expanding and can be completely recovered. There is 1 proximal marker, 3 or 4 distal markers, and markers evenly distributed along the stent body with a distance of 5-10mm. Compatible with microcatheter diameter 0.021"-0.027". Push wire has diameter 0.018" and length 200cm. Standards: FDA and CE and ISO. Packaging: 1 piece/box |
Tra Vinh General Hospital |
|||
81 |
Self-expanding angioplasty memory holder (pelvis), diameter: 7mm-10mm, length: 30mm-180mm, material: Nitinol, system
System: 0.035". |
3 |
Female |
Design: "Peak-to-Valley" and "S-articulations" (stent) help create
compatibility and flexibility; Over The Wire (system).
Material: Nitinol.
Coating: proBIO (Amorphous Silicone Carbide).
Diameter: 7mm, 8mm, 9mm, 10mm.
Length: 30mm, 40mm, 60mm, 80mm.
System length: 70cm, 120cm.
Marker: 4 gold markers at each end of the holder, increase visibility.
Wiring system: 0.035".
Certified: CFS, ISO. |
Tra Vinh General Hospital |
|||
82 |
Picture memory holder
blood vessels (thigh self-expands
shallow, above the stilt), diameter: 5mm-
17mm, length: 30mm-170mm, material: Nitinol, system
System: 0.035". |
10 |
Female |
Design: "Peak-to-Valley" and "S-articulations" (stent) help create
compatibility and flexibility; Over The Wire (system).
Material: Nitinol.
Stent body thickness: 140µm.
Coating: proBIO (Amorphous Silicone Carbide).
Diameter: 5mm, 6mm, 7mm.
Length: 30mm, 40mm, 60mm, 80mm, 100mm, 120mm, 150mm, 170mm, 200mm.
System length: 90cm, 135cm.
Marker: 6 gold markers at each end of the stent, increasing visibility.
Wiring system: 0.035".
Certified: CFS, ISO. |
Tra Vinh General Hospital |
|||
83 |
Balloon angioplasty bracket (pot), diameter: 5mm-10mm, length: 15mm-56mm, material: Stainless Steel, system: 0.035". |
5 |
Female |
Design: "Peak-to-Valley" (stent) helps create compatibility and
flexible; Over The Wire (system).
Material: Stainless Steel.
Stent body thickness: 160µm (diameter 5mm-8mm), 180µm
(diameter 9mm-10mm).
Coating: proBIO (Amorphous Silicone Carbide).
Diameter: 5mm, 6mm, 7mm, 8mm, 9mm, 10mm.
Length: 15mm, 25mm, 38mm, 56mm.
System length: 80cm, 130cm.
Marker: 2 stereotypical markers (shadow).
Wiring system: 0.035".
Certified: CFS, ISO. |
Tra Vinh General Hospital |
|||
84 |
Fall lock |
1.400 |
Female |
Material: Polycarbonate. Withstands pressure 200psi - 1050psi, inner diameter 2.5mm or 0.12", has 3 corners FDA standards |
Tra Vinh General Hospital |
|||
85 |
Lock the breast lift bar
(Stabilizer) |
12 |
Female |
*Used to fix the breast lift bar during breast augmentation surgery
Production standard: stainless steel
*The product is engraved with code, manufacturer logo, and year of manufacture. |
Tra Vinh General Hospital |
|||
86 |
Novolimus-eluting coronary stent |
50 |
Female |
Novolimus-coated biocompatible coronary stent frame. Frame material: Cobalt Chromium, Ball material: Nylon Copolymer, Lattice thickness: 71 µm. Dosage: 5 μg/mm. Catheter length: 140 cm. Marker: Platinum Iridium, Normal pressure: 10-11 atm. Balloon burst pressure: 16 atm. Diameter: 2.25mm - 3.50 mm. Length: 14mm - 48 mm. Quality standards: ISO 13485, CE. |
Tra Vinh General Hospital |
|||
87 |
Cover stent is used in emergency cases |
1 |
Female |
Material: Cobalt Chromium with ProBio coating. Stent frame thickness: diameter 2.5mm, 3.0mm with size 60µm (0.0024 inch); diameter 3.5mm - 4.0mm with size 80µm (0.0031 inch); 4.5mm diameter, 5.0mm has a size of 120µm (0.0047 inch). Length from: 15mm to 26mm. Diameter from: 2.5mm to: 5.0mm. The stent is covered with an ultra-thin layer of Silicon Carbide (PROBIO) and has a single layer design to make the diameter small. Standards: ISO, CE, FDA. Origin: European countries |
Tra Vinh General Hospital |
|||
88 |
Needle puncture of femoral artery and radial vein 18G, 20G |
50 |
Female |
- Metal has no wings or doors. The needle tip is sharp due to being beveled twice. Catheter made of ETFE (Ethylene Tetrafluorethylene) material, smoothly tapered to fit the needle body, thin wall and wide cavity for high flow rate. The transparent blood chamber helps users easily detect when the needle is in the appropriate position. Retention time is 72 hours.
- Sterilization by electron beam. There is radiopaque.
Can be used in other procedures: paracentesis, arterial/venous catheter replacement.
Size: 18G x 2" (51mm); 20G x 1 1/4" (32mm) |
Tra Vinh General Hospital |
|||
89 |
Kim poked the pulse, thighs |
100 |
Female |
Needle puncture of radial and femoral veins. Stainless steel material designed with optimal handle and sharp needle tip for easy operation, Diameter: 18G, 20G, Length: 40mm, 70mm (Depending on product code), Meets FDA standards. |
Tra Vinh General Hospital |
|||
90 |
Radial puncture needle, femoral 18G |
2.000 |
Female |
Threading needles are bladeless and doorless. The Catheter's sharp needle tip is made of ETFE material, smoothly tapered to hug the needle body, thin wall and wide cavity for high flow rate. The transparent blood chamber helps users easily detect when the needle is in the appropriate position. Retention time is 72 hours. Size: 18G x 2" (51mm) |
Tra Vinh General Hospital |
|||
91 |
Peripheral vein needle, bladeless, doorless type No. 22G-24G |
50 |
Female |
- The needle has no wings or doors, there is a groove between the needle and the catheter - Flashback feature helps determine the position of the catheter quickly and intuitively. Sharp needle tip beveled twice. The catheter is made of Polyurethane material - the material will be hard at room temperature and softer at body temperature, resistant to twisting and durable. The transparent blood chamber helps users easily detect when the needle is in the appropriate position.
- Sterilized with EO gas. There is radiopaque.
- Size: 22G x 1" (25mm); 24G x 3/4" (19mm) |
Tra Vinh General Hospital |
|||
92 |
Y-shaped artificial blood vessels |
5 |
Female |
Y-shaped artificial blood vessels used in cardiovascular surgery (abdominal aorta, iliac artery, femoral artery), Polyester material woven using knitting technique increases rupture resistance and limits aneurysm.
Artificial blood vessels are coated with hydrolyzed dehydrogenated collagen to create durable cross-links to ensure fixed blood flow within the graft tube. Aldehyde and Isocyanate are not used during the impregnation process.
Size: diameter: 12x6mm, 14x7mm, 16x8mm, 18x9mm, 20x10mm, 22x11mm, 24x12mm, length: 45cm
Certification: CE |
Tra Vinh General Hospital |
|||
93 |
Artificial blood vessels |
2 |
Female |
Artificial blood vessels used in cardiovascular surgery (thoracic aorta, aortic arch), Polyester material woven using woven technique increases rupture resistance and limits aneurysms. The artificial blood vessels are impregnated with collagen and no Aldehyde and Isocyanate are used during the impregnation process.
The structure is different between the inner and outer sides of the graft to optimize blood flow
Size: diameter: 8-34mm, length: 15-30cm
Certification: CE |
Tra Vinh General Hospital |
|||
94 |
Straight rib brace |
6 |
Female |
Rib fixation brace
Titanium material
1.6 mm thick brace, countersunk screw holes, blue
Straight type, 8 holes
ISO 13485, FDA standards |
Tra Vinh General Hospital |
|||
95 |
Pre-formed rib brace |
6 |
Female |
Rib fixation brace
Titanium material
Brace 1.6mm thick, countersunk screw holes, blue
Type 12 pre-bent holes, radius of curvature in plane 30cm, radius of curvature out of plane 20cm
ISO 13485, FDA standards |
Tra Vinh General Hospital |
|||
96 |
Surgical drainage tube |
5 |
Set |
- Silicone material
- Flat type, size 10 mm, length 102 cm
- EC standards |
Tra Vinh General Hospital |
|||
97 |
Blood straws in the blood vessel |
10 |
Female |
Large inner diameter enhances suction and softness for better remote control, twisted and braided coil design. Inner diameter 0.070", proximal outer diameter 0.0825", distal outer diameter 0.0815". Working length 125cm and 131cm. Distal length 19cm, proximal length 106cm and 112cm, straight end |
Tra Vinh General Hospital |
|||
98 |
Catheter intervention |
30 |
Female |
Full-wall technology JL, JR, XBU, length 100cm, 5F-8F.
FDA standards. |
Tra Vinh General Hospital |
|||
99 |
Interventional catheters of all types and sizes |
20 |
Female |
Hydrophilic coating from 5cm/15cm long tip. Balanced tube body, increased stiffness helps stabilize the procedure, optimize thrust force. Catheter set with attached dilator instead of sheath helps reduce the size at the needle insertion site. Catheter size: 6F, 7F, 8F (Catheter set is 4F, 5F, 6F respectively). Inner / outer diameter of the catheter set: 1.8/ 2.09mm, 2.05/ 2.4mm, 2.28/ 2.7mm available length: 80cm- 110cm. Tip shape: angled, straight. Quality standards: ISO, CE |
Tra Vinh General Hospital |
|||
100 |
Peripheral vascular intervention catheters of all sizes |
10 |
Female |
Material: Arnitel with 3 layers (Polyether - Ester Polymer outer layer, double anti-break woven layer and PTFE inner layer). The double layer of woven fibers prevents breakage and provides clear images, and the smooth inner PTFE layer helps instruments slide easily within the catheter.
Diameter: 6F, 7F, 8F. Type 6F has a Lumen width of 0.070", 7F has a Lumen width of 0.081", 8F has a Lumen width of 0.091".
Length: 55cm, 90cm.
All types of curved heads: LIME, RDC, C1, C2, ST, MP, MP2, RE-S,
HS, Crossover, Bates,
Certified: ISO. |
Tra Vinh General Hospital |
|||
101 |
Coronary intervention tube |
400 |
Female |
Move flexibly and support intervention tools well. The Full Wall flat fiber tube mesh technique helps the tube tube to be wider and the tube to move flexibly. The inner surface is made of improved Pebax material to help the tool be inserted gently and without obstruction. The inner diameter of size 5F is 0.058", 6F is 0.071", 7F is 0.081", 8F is 0.09". There are a full range of interventional curvatures, especially EBU, RBU, IMA, SAL, SL, AL,... Marker is located right behind the soft tip of the catheter. CE standards. |
Tra Vinh General Hospital |
|||
102 |
Coronary intervention tube |
400 |
Female |
Coronary intervention catheter. Material: The inner layer is coated with PTFE, in the middle is a flat layer of high-strength braided stainless steel mesh, the soft outer layer has high optical resistance at the far end. The tube consists of 5 to 6 sections with different hardness on each section. The cage is 0.059" - 0.081" wide, size is 5F - 7F, length ≥100cm. Origin: G7 countries |
Tra Vinh General Hospital |
|||
103 |
coronary intervention catheter type 2x4. |
400 |
Female |
The catheter consists of 3 layers: Inner layer: Made of PTFE material, Middle layer: Core woven with 2x4 metal strip, twisted for special torque, preventing kinking of blood vessels, Outer layer: Made of polymer mixture. Type 6F has Lumen width of 0.070". Curved tip (equivalent to RUNWAY type), ISO, CE, FDA quality standards |
Tra Vinh General Hospital |
|||
104 |
Cardiovascular intervention tube |
10 |
Female |
The expanded catheter goes deep into the coronary artery with a length of 25cm - 40cm, length of shaft 125cm. Sizes 6F -, 8F and 6F long. Hydrophilic coating, spiral connector made of Platinum Iridium |
Tra Vinh General Hospital |
|||
105 |
Interventional catheter with mesh technology, helping the tube lumen to be wide and move flexibly. |
30 |
Female |
Size: Size 5,6,7,8 Fr. The inner diameter of size 5F is 0.058", 6F is 0.071", 7F is 0.081", 8F is 0.09". Length 90cm &100cm. More than 230 types of curved ends, including special types of curved ends: EBU, NOTO, CHAMP, 3DRIGHT... Tube mesh weaving technique uses double woven flat yarn between 2 layers of polymer to help the tube lumen become wider and the tube move flexibly. The outer layer is made of Vest-Tech Nylon material to help increase the ability to absorb light. The distal catheter can be calibrated to match the vascular morphology. |
Tra Vinh General Hospital |
|||
106 |
He cleared the diagnosis |
30 |
Female |
Steel material, double twisted mesh, anti-twist JR, JL, PIG, TIG | length 100cm, diameter 4F-6F. FDA standards. |
Tra Vinh General Hospital |
|||
107 |
Cardiac chamber diagnostic catheter equivalent to Radifocus Optitorque
(Angled Pigtail) |
30 |
Female |
Description: The cardiac diagnostic catheter has a 3-layer structure: the inner and outer layers are polyurethane-rich nylon, the middle layer is stainless steel.
Size: diameter 4Fr (heart width 1.03mm) -5Fr (heart width 1.20mm), length ≥110cm
The walls are extremely thin, creating a wide circumference. Compatible with 0.038'' guidewire. Pressure limit 4Fr: 750psi, 5Fr-6Fr: 1000psi. |
Tra Vinh General Hospital |
|||
108 |
radial pulse diagnostic catheter |
500 |
Female |
Spinning coronary angiography catheter Designed with double braid technology. Tube wall material: different types of Polyamide in 2-layer tube structure. Head shape for intervention through thin tube wall, wide tube tube for maximum flow rate of 23mL/s, Maximum pressure: 1200psi. Compatible with 0.038' guidewire, diameter 5Fr (1.20mm width), length 100 -120cm |
Tra Vinh General Hospital |
|||
109 |
right and left coronary artery diagnostic catheter |
700 |
Female |
- Made of Nylon Pebax material, the tool surface is smooth, slippery, durable at body temperature, thin tube walls, tip has good shape memory
- There are types JL, JR, AL, AR
- All sizes 4F, 5F, length 100cm/125cm
- Inner diameter 0.042"/1.07mm type 4F, 0.046"/1.17mm type 5F, 0.054"/1.37mm type 6F
- Can be used with guide wire 0.035", 0.038"
- Type with or without side holes. Meets FDA standards |
Tra Vinh General Hospital |
|||
110 |
Catheter |
50 |
Female |
Structure: 3 layers of nylon elastomer with stainless steel mesh (SUS). SUS layer for good pushing ability. Polyamide coated surface, rounded tip, coaxial structure. Size: 5Fr (inner diameter 0.043''). Length 100cm. Anti-glare surface, 0.038'' guidewire compatible. Pressure limit 1000psi (equivalent to RF*EA25010M ) |
Tra Vinh General Hospital |
|||
111 |
The cerebral angiography catheter is made of 3 layers of nylon elastomer |
50 |
Female |
Structure: 3 layers of nylon elastomer with stainless steel mesh (SUS). SUS layer for good pushing ability. Polyamide coated surface, rounded tip, coaxial structure. Size: 5Fr (inner diameter 0.043''). Length 100cm. Anti-glare surface, 0.038'' guidewire compatible. Pressure limit 1000psi (equivalent to RF*EH15010M ) |
Tra Vinh General Hospital |
|||
112 |
The shunt supports peripheral vascular intervention at a bent angle |
5 |
Female |
The catheter is sized 4Fr and 5Fr, sliding on a 0.035" (0.018") guide wire, helping to reach the damaged area in the safest and most effective way.
Easy to use, easy to push and pull, good light barrier, safe - Quality standards: ISO, FDA. |
Tra Vinh General Hospital |
|||
113 |
Cannula supporting peripheral intervention, operating length 65cm, 90cm, 135cm, 150cm |
2 |
Female |
These are 4Fr and 5Fr catheters traveling on 0.035", 0.018" and 0.014" guide wires to help reach the damaged area in the safest and most effective way. Marker ring length 15mm or 50mm, working length 65cm, 90cm, 135cm, 150cm.
Easy to use, easy to push and pull, good light blocking, safe
Distal 40cm hydrophilic coating increases the ability to pass through difficult lesions |
Tra Vinh General Hospital |
|||
114 |
Blood suction tube |
5 |
Female |
Nitinol material, wide inner diameter 0.068" and 0.071", maximum outer diameter 0.083" and 0.0855". Length 132cm. Woven coil design, soft beveled tube tip. Support/Compatibility of thrombectomy stents in intervention and treatment of cerebral stroke. Standards: FDA and CE and ISO. - Packaging: 1 piece/box
Origin: G7 countries |
Tra Vinh General Hospital |
|||
115 |
2F vascular catheter
(sonde Fogarty) |
5 |
Female |
*Catheter removes blood clots in arteries, soft tip, break-resistant balloon, packaged with syringe compatible with balloon included.
*Material 100% silicone, latex free, biocompatible. Anti-breakage balloon, flexible stylet inserted into blood vessels during manipulation.
*Size 2F |
Tra Vinh General Hospital |
|||
116 |
3F vascular catheter
(sonde Fogarty) |
10 |
Female |
*Catheter removes blood clots in arteries, soft tip, break-resistant balloon, packaged with syringe compatible with balloon included.
*Material 100% silicone, latex free, biocompatible. Anti-breakage balloon, flexible stylet inserted into blood vessels during manipulation.
*Size 3F |
Tra Vinh General Hospital |
|||
117 |
4F vascular catheter
(sonde Fogarty) |
5 |
Female |
*Catheter removes blood clots in arteries, soft tip, break-resistant balloon, packaged with syringe compatible with balloon included.
*Material 100% silicone, latex free, biocompatible. Anti-breakage balloon, flexible stylet inserted into blood vessels during manipulation.
*Size 4F |
Tra Vinh General Hospital |
|||
118 |
5F vascular catheter
(sonde Fogarty) |
5 |
Female |
*Catheter removes blood clots in arteries, soft tip, break-resistant balloon, packaged with syringe compatible with balloon included.
*Material 100% silicone, latex free, biocompatible. Anti-breakage balloon, flexible stylet inserted into blood vessels during manipulation.
*Size 5F |
Tra Vinh General Hospital |
|||
119 |
Soft tip interventional assist catheter, 100cm strip |
10 |
Female |
Structure: the inner layer is made of PTFE, in the middle is a layer of high-strength braided stainless steel mesh, the outer layer is soft and has high optical resistance at the distance.
Features: outstanding material structure consisting of 5 to 6 zones, each made from materials of different hardness (ZONE Technology).
- BL, JR, JL, MP, AL, Ikari shapes
- Size: size 5F has an inner diameter of 0.059", size 6F has an inner diameter of 0.071", size 7F has an inner diameter of 0.081". Length 100cm. |
Tra Vinh General Hospital |
|||
120 |
Self-expanding peripheral stent |
5 |
Female |
Self-expanding stent, made of shape memory nitinol, with three-axis design to increase the precision of the bracket, Open-cell, diameter 5,6,7,8 mm, length 20-40-60-80-100-120-150mm, catheter length with stent attached 80cm, 120cm and 150cm, using 0.035" guide wire, tantalum marker enhances visibility
Used to open narrow peripheral arteries (iliac, femoral, subclavian...), easy to push, good radiopaque, good tension against the vessel wall - Quality standards: ISO, FDA. |
Tra Vinh General Hospital |
|||
121 |
Self-expanding carotid stent made of shape memory nitinol, diameter 6-10mm |
2 |
Female |
Self-expanding stent made of shape memory nitinol, bracket includes 02 types: Straight and Tapered suitable for carotid artery.: straight type, diameter 6mm-10mm, length 20mm-60mm. Tapered type, length 30mm -40mm, catheter length with stent attached is 135cm, using 0.014" guide wire with 6Fr catheter. Using EX.P.R.T technology in the system The stent release system helps to release the stent exactly at the desired position to avoid phenomenon of stent jumping, premature stent release. Used to open extracranial carotid artery stenosis, easy to push, good radiopaque, there are straight and tapered types to choose from, good tension against the vessel wall. Tantalum marker..Certificates, ISO, CE. |
Tra Vinh General Hospital |
|||
122 |
Coronary stent containing the drug Amphilimus |
50 |
Female |
Bracket frame material: L605 Cobalt Chromium Alloy, Non-polymer, Drug release through osmotic drug reservoir, Bracket frame thickness 70µm - 80µm, 2 markers made of Platinum material on the first (end) part of the rack frame, Bracket frame does not shorten during the expansion process of Amphilimus drug formula: Sirolimus + Fatty Acid, Diameter: 2.5- 4.5 mm. Length: 9mm- 46 mm. 1. Origin: European countries |
Tra Vinh General Hospital |
|||
123 |
Biolimus A9 drug-eluting coronary stent |
100 |
Female |
Description: Biolimus A9 drug-coated coronary stent without polymer coating. Drug content ≥15.6µg/mm
Size: diameter from 2.25mm to 4.0mm, length from 9mm to 36mm.
Material: Cobalt Chronium.
Support bar thickness ≤ 88 µm. . Lattice diameter: ≥1.58mm, compatible with 0.014" guide wire and 5F catheter, Radial force resistance > 0.67bar or 500mmHg.. Standard: ISO,EC |
Tra Vinh General Hospital |
|||
124 |
Everolimus-eluting coronary stent 1.2 µg/mm2 |
100 |
Female |
Everolimus-eluting coronary stent, dosage 1.2 µg/mm2, PLLA/PLGA bioresorbable polymer, coating thickness: 3-5 µm, Cobalt Chromium L605 material,
Stent frame thickness: 65μm, stent frame width 85μm: at both ends and 70 μm: in the middle. Diameter: 2.00mm- 4.50mm, Length: 8mm- 48 mm. Catheter length: 140 cm, Guide tube lumen length: 25 cm, Balloon made of Polyamide/Nylon material 12. Body size approximately 1.9F, body far 2.5-2.9F, Number of ball folds: 3 wings. tip: 0.016", Border across the lesion ≤0.02"
Nominal pressure 7 bar, maximum critical pressure 16 bar. Meets standards: ISO 13485 |
Tra Vinh General Hospital |
|||
125 |
Sirolimus-eluting coronary stent |
100 |
Female |
Material: Cobalt Chromium alloy, Coating: Sirolimus with a concentration of 1.4μg/mm2, Proteqto Polymer is highly biocompatible. Stent bar thickness: 80µm, Catheter length 142cm, tip profile: 0.017", crossing profile: 0.90mm. Critical pressure: 16 bar; Balloon inflation pressure: 6 bar. Diameter: Ø2.25 - 4.5mm, Length Stent: 8.- 48mm, Two radiopaque markers positioned in the ampulla. FDA standards. Origin: G7 countries |
Tra Vinh General Hospital |
|||
126 |
Sirolimus-eluting coronary stent |
100 |
Female |
Co-Cr(L605) core stent, thin Stent wall ≤60µm for all diameters. Coated with Sirolimus dose of 1.4µg/mm2, 3-component Polymer: PLLA, PLCL, self-absorbable PVP. Shortening rate 0%, shrinkage < 4%, Two Pt/Ir markers on the balloon increase visibility. Stent waves of 4 crowns - 8 crowns depending on diameter ensure the integrity of the stent structure. Diameter: 2.0-4.5 mm, length: 8-48mm, NP: 8 atm, RBP: 16 atm, |
Tra Vinh General Hospital |
|||
127 |
Everolimus-eluting coronary stent with CoCr frame material |
20 |
Female |
Stent frame Cobalt Chromium material, coated with Everolimus100µg/cm2. Balloon in stent: material: Pebax. Diameter: 2.0mm- 4.0mm. Length: 8 - 38mm, Crossing profile: 0.039 inch (3.0 x 18mm). Tip cross section 0.017" (3.0x18mm), working length of catheter 145cm. Nominal pressure 9atm-12atm, maximum balloon rupture pressure 16atm. Technical standards: ISO, CE |
Tra Vinh General Hospital |
|||
128 |
Sirolimus coronary powder stent |
100 |
Female |
Cobalt Chromium coronary stent coated with Sirolimus 1.4μg/mm2, Diameter 2.0mm - 4.5mm, length 9mm - 49mm, 3-layer self-absorbable polymer helps optimize drug release, small Strut stent 75μm - 85µm. The shiny material of the stent is Nylon and Pebax, with HYDRAX hydrophilic coating. Positioned with 2 Platinium Iridium markers |
Tra Vinh General Hospital |
|||
129 |
Sirolimus coronary powder stent |
100 |
Female |
1. Drug: Sirolimus, dosage 1.33µg/mm2, coating thickness 3-5µm
2. Stent frame: Cobalt Chromium L605, zigzag stent frame design, 6 vertices - 3 connections between rings of 2.00-2.75 mm diameter stents, 8 vertices design - 4 connections between rings of 3.00-4.50 mm diameter stents
3. Frame thickness: Strut thickness 65 µm
4. Hook (open, closed): combination of open and closed
5. Other features:
- Biodegradable polymer: PLLA/PLGA 50:50.
- Diameter: 2.00, 2.25, 2.50, 2.75, 3.00, 3.25, 3.50, 4.00, 4.50 (mm).
- Length: 08, 09, 13, 15, 18, 23, 28, 33, 38, 40, 44, 48 (mm).
- Stent frame width: At both ends: 85 μm; Middle segment: 70 μm
- Connection width: straight connection at both ends: 85 µm and "U" connection in the middle: 50 µm
- Nominal pressure: 7 bar
- Quality standards: ISO 9001:2015, ISO 13485:2016, ISO 14001:2015 |
Tra Vinh General Hospital |
|||
130 |
Sirolimus-eluting coronary stent 1.4µg/mm2 |
50 |
Female |
Sirolimus 1.4µg/mm2 coated coronary stent with Biolute and ProBio dual coating, stent bar size 60µm - 80µm. Diameter: 2.25 - 4mm, length 9-40mm. Nominal pressure 10 atm, maximum pressure 16 atm Technical standards: FDA, CE. Origin: European countries |
Tra Vinh General Hospital |
|||
131 |
SIROLIMUS 3.9µg/mm drug-eluting coronary stent |
100 |
Female |
Cobalt Chromium L605 material, Poly self-absorbing polymer, coated with Sirolimus dose of 3.9µg/mm Polymer absorption and drug release time is 3-4 months. Lattice eyes arranged like snake scales, thickness 80µm, branch opening 14.5mm² depending on diameter
Stent propulsion system parameters: Propulsion system body is reinforced with stainless steel core, Entry profile: 0.018''. Polyamide elastomer material input. Crossing profile: 0.044'' Balloon material: Nylon 12.- Reference pressure: 9atm. Maximum pressure: 14 atn - 16atm depending on size. Distal shaft diameter: 2.7Fr with hydrophilic coating, proximal part 1.9Fr, Shaft length: 144 cm
Stent size: Diameter 2.25mm - 4.0mm. Length: 9mm- 38mm. Origin: countries in the G7 bloc |
Tra Vinh General Hospital |
|||
132 |
Sirolimus-eluting coronary stent 5.0 µm/mm, |
50 |
Female |
The outside of the stent is coated with sirolimus drug on a biodegradable polymer base combined with an anti-CD-34 antibody layer that actively heals the vessel lumen, drug content 5.0 µg/mm, stent width 90µm. Stent thickness: 100µm stent profile: 0.0361 inch Hydrophilic layer coated with Hydro-X
Stent diameter: 2.5 - 4.0 mm. Stent length: 9 – 38 mm. Quality certification: ISO, CE. Origin: European countries |
Tra Vinh General Hospital |
|||
133 |
Peripheral nitinol shape memory stent, self-expanding, diameter: 5mm - 8mm. Length: 20mm -200mm, compatible with 0.035" wire |
5 |
Female |
Peripheral arterial stents (superficial femoral (SFA), popliteal, ...) self-expanding with shape made of sheath, Nitinol material, close and open cell design (designed with a closed stent cell system at both ends and an open stent cell system in the middle) increase the support and fracture resistance of the stent. The stent is marked with a tantalum marker and a radiation-blocking tip.
Diameter: 5mm - 8mm. Length: 20mm - 200mm. Body shaft length: 75cm and 130cm. Sheath compatibility: 5-7F. Compatible conductor: 0.035". |
Tra Vinh General Hospital |
|||
134 |
Rapamycin-eluting stent |
30 |
Female |
Rapamycin-coated stent is made of Cobalt Chromium material, coated with DL-PLA polymer and Rapamycin drug in a ratio of 4:5. The wall surface is cut with additional grooves, helping the drug to be released accurately into the damaged location, the thickness of the stent frame is 86μm -96.5μm. The two markers on the proximal axis are located 95cm and 105cm from the tip. The stent balloon is made of Pebax material, hydrophilic coating, Rapid Exchange type. Nominal pressure: 10atm, maximum pressure: 14-16atm. Stent diameter: 2.25-4.0mm, stent length: 13-38mm. |
Tra Vinh General Hospital |
|||
135 |
Open-jaw welding knife handle with non-stick nano coating, curved tip, knife body length 23cm |
10 |
Female |
- The knife mount is coated with nano-coated non-stick layer
- Circuit welding / cutting
- Diameter 5 mm; Length 23 cm (9 in.)
- Knife strap comes with knife handle
- Knife head rotation axis: 350 degrees
- Maryland jaw with contour design
- Activate arms or legs
- Knife jaw shape: Curved
- Length of soldering area: 20.3mm
- Length of F149 cutting area: 18.5mm
- Tissue Effect Tissue Induction Frequency 434,000 times
- Compatible with Valleylab LS10, FT10 machines
- Quality standards: ISO 13485, CE, CFG |
Tra Vinh General Hospital |
|||
136 |
Endoscopic surgical welding knife handle with non-stick nano coating, curved tip, blade length 37cm |
15 |
Female |
- The knife mount is coated with nano-coated non-stick layer
- Welding/cutting
- Diameter 5 mm; Length 37 cm (14.6 in.)
- Knife head rotation axis: 350 degrees
- Knife strap comes with knife handle
- Maryland jaw with contour design
- Activate arms or legs
- Curved blade shape
- Length of soldering area 20.3mm
- Cutting area length 18.5mm
- Tissue Effect tissue induction frequency 434,000 times
- Compatible with Valleylab LS10, FT10 machines
- Quality standards: ISO, CE, CFG |
Tra Vinh General Hospital |
|||
137 |
Breast lift bar |
6 |
Female |
The length is engraved right on the bar. The top of the bar is rounded, has a hole in the middle and two serrated edges. In the middle of the bar there is a marker.
Steel material ASTM F 138.
Many sizes from 7 inches to 17 inches.
ISO 13485 standard |
Tra Vinh General Hospital |
|||
138 |
Trocar 10.5 mm for thoracoscopic surgery |
12 |
Female |
Chest wall penetration instrument used specifically for thoracic surgery, consisting of a blunt tip and a twisted threaded non-conducting pipe with a rounded distal end to protect the chest cavity from foreign bodies and stabilize the instruments during surgery.
Length 60mm, diameter 10.5mm, suitable for 11mm diameter tools.
Standards: ISO, CE, FDA |
Tra Vinh General Hospital |
|||
139 |
Trocar 12 mm for internal surgery
Thoracoscopy |
12 |
Female |
The soft thoracic surgical trocar has a soft rubber pad at the tip of the Trocar to avoid tissue damage, including a blunt tip and a twisted threaded non-conducting tube with a rounded distal end to protect the chest cavity from foreign bodies and stabilize the instruments during surgery. Length 60mm, Diameter for tools with a diameter of 12mm Standard: ISO, CE, FDA |
Tra Vinh General Hospital |
|||
140 |
Trocar 5.5 mm for internal surgery
Thoracoscopy |
12 |
Female |
Chest wall penetration instrument used specifically for thoracic surgery, consisting of a blunt tip and a twisted threaded non-conducting pipe with a rounded distal end to protect the chest cavity from foreign bodies and stabilize the instruments during surgery.
Length 60mm, diameter 5.5mm, suitable for tools with diameter 6mm.
Standards: ISO, CE, FDA |
Tra Vinh General Hospital |
|||
141 |
Pressure bag |
24 |
Female |
Allows users to switch from standard pressure to overpressure mode when necessary, Has a pressure release valve to prevent the bag from exploding, many types ≥ 500ml, FDA standards |
Tra Vinh General Hospital |
|||
142 |
Chest drainage valve
(Van Heimlich) |
10 |
Female |
Includes a piece of rubber tubing placed in a plastic tube, integrating a fixed collar with a multi-level drainage catheter adapter and an air filter valve.
ISO 13485, EC standard |
Tra Vinh General Hospital |
|||
143 |
Cardiovascular intervention conductor |
20 |
Female |
Multi-core conductor with ACT ONE technology (double helix design) increases tip durability, torque response and shock resistance. Tip load from 0.3 - 20 gf provides very good support for CTO intervention cases. Coating: silicon, SLIP-COAT or SLIP-COAT on polymer base. Tip: straight, J, pre-shape. Length: 180, 190, 300 cm , 330cm. Quality certification: ISO, CE. |
Tra Vinh General Hospital |
|||
144 |
Neurolic intervention tube |
22 |
Female |
Dimensions: Near-far outer diameter is 2.7Fr-2.4Fr, inner diameter is 0.021", length is 153cm. Material: Stainless steel, hydrophilic, PTFE, Pebax plastic. The microcatheter has a structure including stainless steel fibers wrapped around the body to avoid folding and maintain the shape of the lumen, the peripheral tip of the catheter is soft and straight, the hydrophilic coat covers the outer surface, the PTFE layer lines the lumen. in Finally, Pebax plastic layer. DMSO compatible, compatible with largest conductors 0.018". Standards: FDA and CE and ISO. Packaging: 1 piece/box |
Tra Vinh General Hospital |
|||
145 |
Hydrophilic-coated neurovascular intervention microcatheters of all kinds |
10 |
Female |
PTFE microcatheter, Hydrophilic coated outer layer design helps reduce friction for better navigation in winding blood vessels, increasing durability for long-term use. Various tip shapes are available: Straight tip, 45 degree, 90 degree and J-shaped tip. Inner diameter from: 0.017", 0.021" and 0.027", proximal outer diameter from 2.4F, 2.5F, 3.1F, distal outer diameter from 1.7F, 2.0F and 2.6F . Usable length is 150 cm and 156cm. There are two radiopaque markers. Origin: European countries |
Tra Vinh General Hospital |
|||
146 |
Rib screws |
12 |
Female |
Locking self-drilling screw design for rib splint, blue
Titanium material
Size 2.4mm, length from 7mm to 16mm
ISO 13485, FDA standards |
Tra Vinh General Hospital |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Bệnh viện Đa khoa Trà Vinh:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Bệnh viện Đa khoa Trà Vinh:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.