| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Internal quality control substance CK-MB |
12 |
Jar |
Used to check the quality of CKMB parameters. Extracted from human serum with a defined range of CKMB values. Capacity: R: 1x5ml On the chemical bottle, there is a chemical identification barcode attached. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
1x5ml |
||
2 |
Chemicals for quantifying total protein in blood |
7 |
Box |
TOTAL PROTEIN is used to indicate: - To diagnose liver disease.. Capacity: R: 6x50ml Active ingredient: Sodium hydroxide 0.5 M Potassium iodide 7.50 mM Copper sulphate 15.9 mM K-Na tartrate 46.8 mM Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
6x50ml |
||
3 |
CK-MB quantitative chemicals in the blood |
7 |
Box |
CK MB is used to indicate: - Diagnosis of myocardial infarction Capacity: - R1: 2x41.5ml - R2: 2x10.5ml Concentration: Reagent 1 imidazole buffer pH 6.1 125 mmol/L, D-glucose 25 mmol/L, NADP 2.5 mmol/L, Hexokinase ≥ 6800 U/L, EDTA-Na2 2 mmol/L, sodium azide < 0.1% Reagent 2: Imidazole buffer pH 8.9 125 mmol/L, creatine phosphate 250 mmol/L, ADP 15.2 mmol/L, G6PDH ≥ 8800 U/L, sodium azide < 0.1% The chemical bottle has a chemical identification barcode attached. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
2x41.5ml + 2x10.5ml |
||
4 |
CRP quantitative test control materials (2 levels) |
12 |
Box |
CRP quantitative test control materials Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
2x1ml |
||
5 |
Chemicals to quantify HBA1C in blood |
80 |
Box |
HBA1C is used to indicate: - To test for diabetes. Capacity: - R1: 1 x 18.3 ml - R2: 1 x 3.3 ml - LYS: 2x16 ml Reagent concentration: R1: Latex: 4.00%, Sodium Azide: 0.95 g/L R2: Anti-humanEmoglobin A1c Mouse Mon, Stabilizers. R3: Stabilizer, lyse Conversion formula: NGSP method units: %HbA1c = 0.0915 * (Res in mmol/mol) + 2.15% IFCC method units: mmol/mol = 10.93 * (Res in %) - 23.5mmol/mol Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
1x18.3 ml +1x3.3 mL+2x16 ml |
||
6 |
High quality internal control substance HBA1C |
6 |
Jar |
HBA1C Control High Used to check Hba1C quality at high values. Extracted from whole human blood with determined high-value pathologies. Capacity: R: 1x0.5 mL The chemical bottle has a chemical identification barcode attached. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
1x0.5 ml |
||
7 |
Low level internal quality control substance HBA1C |
6 |
Jar |
HBA1C Control Low Used to check Hba1C quality at low values. Extracted from whole human blood with determined high pathological values. Capacity: R: 1x0.5 ml Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
1x0.5 ml |
||
8 |
HBA1C calibration |
12 |
Box |
HbA1c Calibrator Used to calibrate the Hba1C parameter. Extracted from whole human blood with determined value. Capacity: R: 1x2ml +4x0.5 mL On the chemical bottle, there is a chemical identification barcode. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
1x2ml +4x0.5 mL |
||
9 |
Concentrated detergent for biochemical testing machines |
12 |
Box |
The active cleaning ingredient is used to mix with distilled water, creating a cleaning solution for the ISE testing equipment system. Capacity: 1 x 100ml. On the chemical bottle, there is a chemical identification barcode attached. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
1 x 100ml |
||
10 |
ZINC quantitative chemicals |
10 |
Box |
Reagent form: Prepackaged liquid. Application: To quantitatively determine Zinc in serum to support the diagnosis and treatment of malabsorption syndrome, chronic liver disease, chronic kidney disease, sickle cell disease, diabetes, malignancy and other chronic diseases. Active concentration: Reagent: R Bicarbonate Buffer, pH 9.8 185 mmol/L 5-Br-PAPS 0.05 mmol/L Sodium citrate 125 mmol/L Dimethylglyoxime 5 mmol/L Surfactants 1 % Preservatives and stabilizers Standard: Std Zinc 200 µg/dL 30.6 µmol/L Storage: 15 – 25°C. Compatible: Use with all open system biochemical testing machines. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
1 x 50 mL + 1 x 3 mL |
||
11 |
Chemical to quantify blood clotting time PT |
6 |
Box |
Prothrombin Time, Calcium thromboplastin to determine a Prothrombin Time stage. Product code: 41001 Active ingredient: Lyophilized rabbit brain Thromboplastin with a final concentration of 10 mM calcium chloride stable calcium chloride solution 0.025 mol/l.. Capacity: 10x2 mL Reagent form: Liquid, pre-packaged. Storage: 2-10° C Performance: Normal Control Plasma 12.5 sec: SD ± 0.4 sec, CV 2.9% Pathological Control Plasma 31.7 sec: SD ± 1.0 sec, CV 3.2% Pool of normal plasmas 11.2 sec SD: ± 0.3 sec, CV 3.0% Pool of pathological plasmas 15.4 sec: SD ± 0.4 sec, CV 2.4% Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
10x2ml |
||
12 |
Fibrinogen blood clotting chemical |
12 |
Box |
Fibrinogen is a reagent for determining the concentration of fibrinogen in plasma. Active ingredient: Thrombin: vial containing lyophilized trombin. After reconstitution, the concentration is approximately 100 NIH units of trombin/ml. Imidazole buffer solution: 0.05 M imidazole solution, pH7.3. Reference plasma: vial containing lyophilized plasma. See the Fibrinogen value indicated on the label Capacity: Thrombin: 10 x 1 ml + Reference plasma: 1 x 1 ml + Imidazole buffer: 2 x 60 ml Reagent form: Liquid, pre-filled. Storage: 2-10° C Efficiency: 12.1 sec: SD ± 0.3 sec, CV: 2.7 % 20.4 sec: SD ± 0.6 sec, CV: 3.2 % Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
10 x 1 ml + 2x60 + STD: 1x1mL |
||
13 |
Control material for quantitative blood coagulation test at normal level |
12 |
Box |
Normal reference plasma is designed for use in controlling the determination of prothrombin time, thrombin time, activated partial thromplastin time and fibrinogen. Active ingredient: lyophilized normal human plasma pool obtained with citrate as anticoagulant Storage: 2-10° C Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
6 x1ml |
||
14 |
Control material for quantitative blood coagulation testing at pathological levels |
12 |
Box |
Pathological reference plasma is designed for use in controlling the determination of prothrombin time, thrombin time, activated partial thromplastin time and fibrinogen. Active ingredient: lyophilized normal plasma aggregates obtained with citrate as anticoagulant, processed to obtain abnormally prolonged prothrombin, thrombin and activated partial thromboplastin times and low fibrinogen concentrations. Storage: 2-10° C Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
6 x1ml |
||
15 |
Cuvette used for blood coagulation testing machine |
1 |
Box |
Cuvette used for automatic coagulation machine Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
6x10x32 |
||
16 |
Ovarian Cancer Test |
600 |
kiểm TRA |
Cancer Antigen 125 is an immunoassay reagent for the in vitro quantitative determination of Cancer Antigen 125 (CA125) in human serum and plasma using a fully automated immunoassay analyzer to aid in the diagnosis of ovarian cancer and other diseases. Active ingredients: Magnetic Beads (MB): Streptavidin coated magnetic particles, 0.45 mg/mL; 0.1 M PBS; 0.05%, ProClin300. Reagent B (RB): Biotinylated CA125, antibody, 0.8 mg/L, 0.05 M PBS; 0.05% ProClin300. Reagent A (RA): Ru complex-labeled CA125 antibody, 1.0 mg/L; 0.05 M PBS; 0.05% ProClin300. CA125 Calibrator: CA125 antigen, 0.05M HEPES, 0.05% ProClin 300. CA125 Control: Material CA125 antigen, 0.05 M HEPES, 0.05% ProClin 300 Compatible devices: Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2 ~ 8 ℃ for 18 months, 56 days in the machine. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
50 test |
||
17 |
Pancreatic and biliary tract cancer testing |
600 |
kiểm TRA |
Carbohydrate Antigen 19-9 is an immunoassay reagent for the in vitro quantitative determination of Carbohydrate Antigen 19-9 (CA19-9) in human serum or plasma using a fully automated immunoassay analyzer to monitor the treatment effects of pancreatic and biliary tract malignancies. Active ingredients: MB: Streptavidin coated magnetic particles, 0.45 mg/mL; 0.1 M phosphate-buffered saline (PBS); ProClin300. RB: Biotinylated CA19-9 antibody, 3.0 mg/L; 50 mM HEPES; ProClin300. RA: Ru complex-labeled CA19-9 antibody, 1.5 mg/L; 50 mM HEPES; ProClin300. Calibrator: CA19-9 antigen, 100 mM PBS pH7.4, ProClin 300. Control Material (Optional): CA19-9 antigen, 100 mM PBS pH7.4, ProClin 300. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 18 months. 56 days in the machine. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
50 test |
||
18 |
Lung Cancer Test |
1.000 |
kiểm TRA |
Cytokeratin Fragment 19 is an immunoassay reagent for the in vitro quantitative determination of Cytokeratin Fragment 19 (CYFRA21-1) in human serum and plasma using an automated immunoassay to aid in the diagnosis of lung cancer. Active ingredients: MB: Streptavidin coated magnetic particles, 0.45 mg/mL; 0.1M phosphate-buffered saline (PBS); ProClin300. RB: Biotinylated CYFRA21-1 antibody, 0.8 mg/L; 0.1M phosphate-buffered saline (PBS); ProClin300. Standard: ISO 13485 or equivalent. RA: Ru complex-labeled CYFRA21-1 antibody, 1.0 phosphate-buffered saline (PBS); ProClin300 Calibrator: AFP antigen, 0.1 M PBS, ProClin 300. Control Material (Optional): AFP antigen, 0.1 M PBS, ProClin 300. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 18 months. 56 days in the machine. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
50 test |
||
19 |
Prostate Cancer Test |
600 |
kiểm TRA |
Total Prostate Specific Antigen is an in vitro immunoassay reagent for the quantitative determination of total prostate specific antigen (tPSA) in human serum or plasma, and is used primarily clinically for supportive and differential diagnosis of prostate diseases. Active ingredients: MB: Streptavidin coated magnetic particles, 0.45 mg/mL; 0.1 M PBS; ProClin300. RB: Biotinylated PSA antibody, 0.2 mg/L; 0.1 M PBS; ProClin300. RA: Ru complex-labeled PSA antibody, 0.1 mg/L; 0.1 M PBS; ProClin300. Calibrator: PSA antigen, 0.1 M HEPES buffer, ProClin 300. Control Material (Optional): PSA antigen, 0.1 M HEPES buffer, ProClin 300. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 18 months. 56 days in the machine. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
50 test |
||
20 |
Prostate Cancer Test |
600 |
kiểm TRA |
Free Prostate Specific Antigen An in vitro immunoassay reagent for the quantitative determination of free prostate specific antigen (fPSA) in human serum or plasma. The fPSA/tPSA ratio can be used for the differential diagnosis of prostate cancer and benign prostatic hypertrophy. Active ingredients: MB: Streptavidin coated magnetic particles, 0.45 mg/mL; 0.1 M phosphate-buffered saline (PBS); ProClin300. RB: Biotinylated fPSA antibody, 0.2 mg/L; 0.1 M PBS; ProClin300. RA: Ru complex-labeled PSA antibody, 0.1 mg/L; 0.1 M PBS; ProClin300. Calibrator: PSA antigen, 0.1 M HEPES buffer, ProClin 300. Control Material (Optional): PSA antigen, 0.1 M HEPES buffer, ProClin 300 Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 18 months. 56 days in the machine. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
50 test |
||
21 |
Thyroid Cancer Test |
600 |
kiểm TRA |
Thyroglobulin Antibody is an immunoassay for the quantitative determination of antibodies to thyroglobulin in human serum and plasma. Anti-TG determination is used as an aid in the detection of autoimmune thyroid diseases. used as an aid in postthyroidectomy monitoring. Active ingredients: (MB): Streptavidin coated with microparticles; preservatives. (RB): Tg~Biotin, 0.05 M MES, preservative. (RA): Anti-Tg~Ru(bpy)32+, 0.05 M MES; preservatives. Calibration (High): Anti-Tg serum, preservative. Calibration (Low): Anti-Tg serum, preservative. Control (High): Anti-Tg serum, preservative. Control (low): Anti-Tg serum, preservative. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in machine (temperature 4 ~ 15 ℃) Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
50 test |
||
22 |
Cardiovascular disease testing |
2.400 |
kiểm TRA |
Troponin I is an in vitro immunoassay reagent for the quantitative determination of cardiac troponin I in human serum and plasma. This test is intended to aid in the diagnosis of myocardial infarction. Active ingredients: MB: Streptavidin-coated micro magnetic beads 0.75mg/mL: 0.1 M PBS; 0.05% ProClin™ 300. RB: Anti-cTnI-Ab~biotin 0.8 mg/L: 0.05 M MES buffer; 0.05% ProClin™ 300. RA: Anti-cTnI-Ab~Ru(bpy) 3 2+ 0.63 mg/L: 0.05 M MES buffer; 0.05% ProClin™ 300. Calibration (High): Equine serum, 0.05% ProClin™ 300. Calibration (Low): Equine serum, 0.05% ProClin™ 300. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in the machine. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
100 test |
||
23 |
Test folic acid concentration in blood |
500 |
kiểm TRA |
Folate is an immunoassay reagent for the in vitro quantitative determination of folate in human serum, aiding in the diagnosis of disorders associated with folate deficiency. Active ingredient: PT2: Sodium 2-mercaptoethanesulfonate (MESNA). PT3: Sodium Hydroxide. MB: Streptavidin-coated microparticles, 0.75 mg/mL; PBS; ProClin300. RB: Biotinylated folate coupled BSA, 0.6 mg/L; HEPES; preservative. RA: Ru complex-labeled folate binding protein, 0.3 mg/L; HEPES; preservative. Folate Calibrator: folate antigen; horse serum; Folate preservative. Control Material: folate antigen; horse serum; Folate preservative. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in the machine. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
100 test |
||
24 |
Insulin testing |
500 |
kiểm TRA |
Insulin is an in vitro immunoassay reagent for the quantitative determination of insulin in human serum and plasma. Active ingredients: MB: Magnetic particle Streptavidin coated bacteria; preservatives. RB: Anti-Insulin-Ab~biotin: 50 MES; preservatives. RA: Anti-Insulin-Ab~Ru(bpy) 3 2+ : MES 50 mM; preservatives. Calibrator (High): bovine serum, preservative; freeze dried. Calibrator (Low): bovine serum, preservative; freeze dried. Control (High): bovine serum, preservative; freeze dried. Control (Low): bovine serum, preservative; freeze dried. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in the machine. Standard: ISO 13485 or equivalent. |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
100 test |
||
25 |
Vitamin D test |
1.200 |
kiểm TRA |
25-OH Vitamin D Total is an immunoassay reagent for the in vitro quantification of total 25-hydroxy Vitamin D in human serum and plasma. Results can be used to aid in the diagnosis of Vitamin D adequacy. Active ingredients: PT2 1.4% Dithiothreitol PT3 0.25M Sodium Hydroxide MB: Streptavidin-coated microparticles, 0.75 mg/mL: 0.1M PBS; 0.05% ProClin™ 300 RB: 25-OH vitamin D~ Biotin: 0.05M MES; 0.05% ProClin™ 300 RA: Anti-vitamin D ~Ru(bpy) 2+ 3: 0.05M BIS-Tris; 0.05% ProClin™ 300 Calibrator(High): Horse serum, 0.05% ProClin™ 300; lyophilized Calibrator(Low): Horse serum, 0.05% ProClin™ 300; lyophilized Control Material (High): Horse serum, 0.05% ProClin™ 300; lyophilized. Control Material (Low): Horse serum, 0.05% ProClin™ 300; lyophilized Compatible devices: Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2 ~ 8 ℃ for 18 months, 8 weeks in the machine. Standard: ISO 13485 or equivalent |
Tran Lam General Hospital. Address: No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province. |
100 test |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor BỆNH VIỆN ĐA KHOA TRẦN LÃM:
No similar goods purchased by the Investor were found.