| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
CT Scanner < 64 slices/revolution |
1 |
Machine |
"I. General Requirements: - 100% new goods, manufactured in 2025 or later - Power supply compatible with Vietnamese voltage - Operating environment conditions in the scanning room: + Maximum temperature: ≥ 25°C + Maximum humidity: ≥ 75% - Meets minimum standards ISO 13485, CE or equivalent - Origin of main system: from G7 countries II. Configuration: 32-slice/rotation CT Scanner system, including: Gantry: 1 set Detector: 1 set High-voltage generator: 1 set X-ray tube: 1 unit Patient table: 1 unit Control station: 1 set Software: Basic scanning software/functions + Scanning modes: Spiral, sequential, survey + Survey scanning program, real-time display Iterative reconstruction software: 1 set Separate scanning program for children" The package includes: 1 set of 3D dose modulation software, 1 set of 3D radiation dose reporting software, 1 set of DICOM connection software, 1 set of contrast agent imaging support software, 1 set of metal artifact reduction software, 1 set of virtual endoscopy software, film printing software, error message display and remote support software/functions, and advanced image processing software (at least: 2D image display software, 3D image display software, vascular imaging and display software, vascular background removal software, multi-plane oblique and curved reconstruction software, lung imaging, reconstruction and display software, spinal image reconstruction and observation software, CD/DVD recording software, bone removal software, reconstruction priority software, pre- and post-contrast tube trajectory synchronization software, automatic MPR reconstruction software, automatic contrast agent penetration threshold imaging software, and chart creation software. Accessories for a CT scanner, including at least: Patient-to-operator communication system: 1 set Patient positioning accessories: 1 set Phantom and mounting bracket: 1 set Other equipment and accessories, including at least: Single-lumen contrast agent syringe: 1 set Online uninterruptible power supply (UPS) for the computer system, power ≥ 3kVA: 1 set Online UPS ≥ 30 kVA: 1 set Lead apron: 1 set Table and chairs for the control room: 1 set Camera and patient monitoring screen: 1 set X-ray warning light: 1 unit TECHNICAL SPECIFICATIONS: Machine compartment Maximum rotation speed ≤ 0.8 seconds/360-degree rotation Machine compartment diameter: ≥ 70 cm Maximum scanning field: ≥ 43 cm Control panel in the machine compartment Equipped with a positioning system Laser System Detector Number of reconstructed slices per rotation: ≥ 32 slices Number of detector arrays: ≥ 32 arrays Total number of detector elements: ≥ 24,000 Thinnest slice thickness: ≤ 0.625 mm Beam lamp Type 1 focal point with focal size: ≥ (0.8 x 0.8) mm Or type 2 focal point with smallest focal size: (0.8 - 1.0) x (0.8 - 1.0) mm Maximum current through lamp: ≥ 225 mA Anode heat storage: ≥ 2 MHU Maximum anode heat dissipation capacity: ≥ 335 kHU/min High voltage generator Maximum power: ≥ 24 kW Voltage: from ≤ 80 kV to ≥ 130 kV; divided into ≥ 4 levels Table Patient Scanning Range: ≥ 120 cm Adjustable Table Height: ≤ 50 cm to ≥ 88 cm Table Load Capacity: ≥ 180 kg Maximum Movement Speed: ≥ 100 mm/second Control Station Screen Size: ≥ 23 inches Screen Resolution: ≥ (1920×1080) Reconstruction Matrix: ≥ (512 x 512) Maximum Image Reconstruction Speed: ≥ 15 frames/second Software Basic imaging software/functions + Scanning Modes: Spiral, Sequential, Survey + Survey imaging program, real-time display Iterative reconstruction software: 1 set Pediatric imaging program: 1 set 3D Dose Modulation software: 1 set Dose reporting software: 1 set DICOM connection software: 1 set Support program Contrast-assisted imaging software: 1 set; Metal artifact reduction software: 1 set; Virtual endoscopy software: 1 set; Film printing program; Error message display and remote support software/functions; Advanced image processing software/functions, minimum: 2D image display software; 3D image display software; Blood vessel imaging and display software; Blood vessel background removal software; Multi-plane oblique and curved reconstruction software; Lung imaging, reconstruction, and display software: available; Spinal reconstruction and observation software; CD/DVD recording software; Bone removal software; Reconstruction priority software; Software to synchronize the rotation trajectory of the image tube before and after contrast-assisted imaging; Automatic MPR reconstruction software; Automatic imaging based on contrast agent penetration threshold; Chart creation and volume calculation software. |
Health Center in Kim Boi area |
|||
2 |
CT Scanner < 64 slices/revolution |
1 |
Machine |
I. General Requirements - 100% new goods, manufactured in 2025 or later - Power supply compatible with Vietnamese voltage - Operating environment conditions for the imaging room: + Maximum temperature: ≥ 25°C + Maximum humidity: ≥ 75% - Meets minimum standards ISO 13485, CE or equivalent - Origin of main system: from G7 countries II. Configuration of a 32-slice/rotational CT Scanner System, including: Gantry: 1 unit; Detector: 1 unit; High-voltage generator: 1 unit; Radiation tube: 1 unit; Patient table: 1 unit; Control station: 1 unit; Software: Basic imaging software/functions + Scanning modes: Spiral, sequential, survey + Survey imaging program, real-time display; Reconstruction software: 1 unit; Pediatric imaging program: 1 unit; 3D dose modulation software: 1 unit; Dose reporting software: 1 unit; DICOM connection software: 1 unit; Contrast agent support software: 1 unit; Metal artifact reduction software: 1 unit; Virtual endoscopy software: 1 unit; Film printing program; Error message display and remote support software/function; Advanced image processing software/function, minimum: Software 2D image display software; 3D image display software; Blood vessel imaging and display software; Blood vessel background removal software/function; Multi-plane inclined and curved reconstruction software; Lung imaging, reconstruction, and display software: available; Spinal reconstruction and observation software; CD/DVD recording software/function; Bone removal software; Reconstruction priority software; Software to synchronize the rotation trajectory of the image tube before and after imaging with contrast agent; Automatic MPR reconstruction software; Automatic imaging based on contrast agent infiltration threshold; Charting and volume calculation software. Accessories for the CT scanner, minimum including: Intercom system between the scanner operator and the patient: 1 set; Patient positioning accessories: 1 set; Phantom and mounting bracket for machine calibration: 1 set; Other equipment and accessories, minimum including: Single-lumen contrast agent syringe: 1 set; Online uninterruptible power supply for the computer system, power ≥ 3kVA: 1 set; UPS Online ≥ 30 kVA: 1 set Lead apron: 1 set Table and chairs for control room: 1 set Camera and patient monitoring screen: 1 set Warning light for X-ray emission: 1 unit TECHNICAL SPECIFICATIONS Machine compartment Fastest rotation speed ≤ 0.8 seconds/360-degree rotation Machine compartment diameter: ≥ 70 cm Maximum scanning field: ≥ 43 cm Control panel in the machine compartment Laser positioning system Detector system Number of reconstructed slices per rotation: ≥ 32 slices Number of detector arrays: ≥ 32 arrays Total number of detector elements: ≥ 24,000 Thinnest slice thickness: ≤ 0.625 mm X-ray tube Type 1 focal point with focal size: ≥ (0.8 x 0.8) mm Or type 2 focal points with focal size Smallest: (0.8 - 1.0) x (0.8 - 1.0) mm Maximum current through bulb: ≥ 225 mA Anode heat storage: ≥ 2 MHU Maximum anode heat dissipation capacity: ≥ 335 kHU/min High voltage generator Maximum power: ≥ 24 kW Voltage: from ≤ 80 kV to ≥ 130 kV; Divided into ≥ 4 levels Patient Table Scanning range: ≥ 120 cm Adjustable table height: ≤ 50 cm to ≥ 88 cm Table load capacity: ≥ 180 kg Maximum movement speed: ≥ 100 mm/second Control Station Screen size: ≥ 23 inches Screen resolution: ≥ (1920×1080) Reconstruction matrix: ≥ (512 x 512) Maximum image reconstruction speed: ≥ 15 images/second Software Basic imaging software/functions + Scanning modes: Spiral, sequential, survey + Survey imaging program, real-time display Iterative reconstruction software: 1 set Separate imaging program for children: 1 set 3D dose modulation software: 1 set Dose reporting software: 1 set Connection software DICOM: 1 set Contrast-assisted imaging support program: 1 set Metal artifact reduction software: 1 set Virtual endoscopy software: 1 set Film printing program Error message display and remote support software/functions Advanced image processing software/functions, minimum: 2D image display software 3D image display software Vascular imaging and display software Vascular background removal software Multi-plane oblique and curved reconstruction software Lung imaging, reconstruction and display software: available Spinal reconstruction and observation software CD/DVD recording software Bone removal software Reconstruction priority software Synchronization software for the rotation trajectory of the image tube before and after contrast-assisted imaging Automatic MPR reconstruction software Automatic contrast agent penetration threshold imaging software Chart generation and volume calculation software |
Health Center in Kim Boi area |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor TRUNG TÂM Y TẾ KHU VỰC KIM BÔI:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding TRUNG TÂM Y TẾ KHU VỰC KIM BÔI:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.