1 |
(Kit) Blood straws |
450 |
Female |
Twisted and braided coil design, covered with hydrophilic.
- Far away and can be shaped by steam. The inner diameter 0.070 ", the outer diameter of the head is nearly 0.0825", the outer diameter of the head is 0.0815 ".
- Operating length is about 125cm-131cm. The head length is 19cm far, the head length is nearly 106cm-1112cm.
* Standard: CE belongs to the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
2 |
(Kit) Blood straws |
50 |
Female |
- Size: Outside diameter near: 6F. Inner diameter: .062in; .068in; .072in. Length: ≥ 132cm
- Material: nitinol. Cover water.
- Characteristics: Redglide technology helps increase smoothness, reduces friction when moving in the blood vessels.
* Standard: ISO 13485, CE/MDR of the European Union and FDA (US Food and Drug Administration).
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
3 |
(Kit) Blood straws |
15 |
Female |
- Size: Outside diameter near/far: 6f/6f; The length is about 135cm.
- Characteristics: Blood suction tube.
* Standard: ISO 13485, CE/MDR (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
4 |
(Kit) Blood straws |
15 |
Female |
- Size: Outside diameter near / far: 8f / 8f; Length: 85cm, 115cm.
- Characteristics: Blood suction tube.
* Standard: ISO 13485, CE/MDR (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
5 |
(Kit) Blood straws |
70 |
Female |
The thrombosis stent designed closed and opened eyes, nitinol nitrogen, the marker made of platinum - Tungsten.
- Stent size 4mm, compatible with the microplasia with a diameter of internal .017 ", length 19 mm - 29 mm. There are 3 markers in the distance and 1 close segment.
- Stent size 5mm: compatible with the micro -pipe with a diameter of .021 ", length of 33 mm - 48 mm. There are 3 - 8 markers on the stent body to increase contrast.
- Stent size 6mm: compatible with the micro -pipe with a diameter of .021 ", length of 45 mm - 67 mm. There are 9 - 15 marker on the stent body to increase contrast.
- The working length of the stent is about: 10mm - 50mm.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
6 |
RF types of arrhythmia treatment for all kinds, sizes |
10 |
Female |
- Catheter cutting with PT/IR head can bend 270 degrees. Length ≥ 110 cm, 4 mm burner, curvature of about 48mm.
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
7 |
RF types of arrhythmia treatment for all kinds, sizes |
10 |
Female |
- Catheter cutting with PT/IR head can bend 270 degrees. Length ≥ 110 cm, burner 4 mm. The curvature is about 57mm.
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
8 |
RF types of arrhythmia treatment for all kinds, sizes |
100 |
Female |
2-way physiological cutting catheter, 4mm, 7F electrode head, 2-5-2 electrode distance, about 115cm long, automatic control handle that reduces the movement of the catheter, drives two-way changes, monitors the temperature with the Thermocouple and Thermistor sensor, the comfacegrip handle.
* Product origin: G7
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
/ 1 piece |
||
9 |
RF types of arrhythmia treatment for all kinds, sizes |
10 |
Female |
The physiological cutting cutting Catheter with 2-way curvature control 8F, sophisticated laser groove tip, cooler than 5 degrees compared to 12-hole type, 1-4-1 mm electrode distance, new braided design optimize torque resistance, curved angle from 180 to 230 degrees, 115 cm long.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
/ 1 piece |
||
10 |
The kit includes the catheter of the carnelian catheter to intervene |
24 |
Female |
Carnelian catheter for super selective blood vessels:
- Tungsten anti -twisting; Ptfe material, tip marker platinum, coating Hydrophilic
- The shape inside the pipe: Tapered and straight
- Large flow flow
- Cover long layer of water: from 60cm - 110cm.
- Outside diameter: 2.7F - 2.9F
- Diameter outside the far end: 1.7f - 2.7F
- Compatible with micro wire: from 0.016 " - 0.025"
- Length: from 70cm - 150cm.
- Withstand pressure up to 1,000 psi.
- Attached with M-Read conductor (0.016 inch) with a 5cm contrast.
- Tip nipple shape: Straight; 45 degrees; COBRA; W Angle.
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
11 |
The 3 -chamber movement has a fibrillation, compatible with MRI body |
2 |
Set |
- Compatible with 1,5 Tesla 1.5 Tesla. MRI scan can be implanted immediately after transplanting.
- MultiPoint Pacing - Multipoint Pacing on each heart cycle to improve hemodynamics and clinical response.
- 4 -pole left ventricular electrode wire with 10 directions of rhythmic vector to avoid high pacing threshold and diaphragm.
- Parylene coating against scratches.
- VECTSELECT Quartet function helps to check the vector chain easily.
- Quickopt feature helps optimize cycle range
- The Cold Can function provides an additional shock vector RV-SVC in case of a shocking electrode wire
- Shockguard function helps to reduce shock
- Suseability function helps to relieve the wrong wave t
- Compatible with standard shock power cord DF4
- Corvue function tracking chest resistance helps detect pulmonary edema
- Feature features Farfield MD and Chamber Chamber onset occur to distinguish VT and SVT
- ATP tachycardia cutting function before charging and during charging in the VF region
- SYNCAV CRT technology automatically adjusts the atrial space changes based on the internal transmission of the patient to tweak the synchronous rhythm of the two ventricles.
- Alarm the patient by vibration
- Shocking energy 40J
- Use QHR battery
- Weight 80g, volume 38 cc
- Standard connection IS4-LLLL left ventricular wire
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
12 |
One -chamber vibrating machine (ICD) compatible with MRI |
1 |
Set |
• Low energy Bluetooth® (LE) communication connected to a smartphone.
• Deft Response ™ technology optimizes electric shocking for each patient.
• VF Therapy Assurance feature reduces the time to treat patients with hemodynamic disorders.
• The feature of the rhythm cutting (ATP) before and while charging in the VF region ends the tachycardia without high voltage.
• Shockguard ™ technology with DecisionTX ™ programming reduces inappropriate treatments and minimize the needs of programming adjustments when placing the device.
- Securesense ™ RV feature detects electrode wire noise.
- Feature distinguishing tachycardia on ventricular wave shape Far FIELD MD ™ Morphology Advanced SVT and VT Distinguish to reduce inappropriate treatments.
• The sensitive ™ sensory algorithm allows flexibility to overtake over excessive tense t wave without reducing sensitivity.
• The Dynamictx ™ series detection feature automatically changes the electric shock configuration to ensure electric shocking treatment when detecting high current.
• MRI Ready standard device when used with MRI compatible electrodisions for MR 1.5T and 3T (TESLA) captures. MRI scan can be implanted immediately after transplanting.
• Standard DF4 electrode connection reduces the number of screws
• Cold Can programming provides additional RV-SVC electric shock configuration, shell from shock direction.
• Dual warning to patients: by sound from the device and image alert from using Mymerlinpulse phone.
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
13 |
01 chamber pacemaker has a pacemaker |
3 |
Set |
- Allow 3 Tesla 3 Tesla to have no limited areas.
- 10 -year warranty and 100% battery warranty in the first 6 years and 50% gradually decreased in the next 4 years.
- It is possible to activate and turn off the MRI mode with a handheld device (SJM MRI activator). MRI scan can be implanted immediately after transplanting.
-AutoCapture pacemaker system allows maximum response to the pacing threshold with the ability to confirm the rhythm of each beat-by-teat pulse. The AutoCapture span system automatically generates 5V backup pulse when detected loss, can program both single or bipolar.
- Save the center of the heart inside the heart chamber up to 14 minutes
- Weight 19g, volume 9.7 cc
The company participating in the bid must have a commitment to provide a programming machine for checking during and after placing a permanent pacemaker for the patient.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
14 |
01 chamber pacemaker has a pacemaker |
2 |
Set |
- Allow 3 Tesla 3 Tesla to have no limited areas.
- 10 -year warranty and 100% battery warranty in the first 6 years and 50% gradually decreased in the next 4 years.
- It is possible to activate and turn off the MRI mode with a handheld device (SJM MRI activator). MRI scan can be implanted immediately after transplanting.
- Invisilink wireless communication, combined with Merlin@home and Merlin.net patient tending device to allow daily tracking of the machine.
-AutoCapture pacemaker system allows maximum response to the pacing threshold with the ability to confirm the rhythm of each beat-by-teat pulse. The AutoCapture span system automatically generates 5V backup pulse when detected loss, can program both single or bipolar.
- Corvue feature monitoring pulmonary edema by monitoring the resistance penetration of the chest and allowing patients and doctors to choose a warning.
- Weight 20g, volume 10.4 cc
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
15 |
02 -chamber pacemaker has a pacemaker |
13 |
Set |
- Allow 3 Tesla 3 Tesla to have no limited areas.
- 8 -year warranty and 100% battery warranty in the first 5 years and 50% decrease in the next 3 years.
- It is possible to activate and turn off the MRI mode with a handheld device (SJM MRI activator). MRI scan can be implanted immediately after transplanting.
-AutoCapture pacemaker system allows maximum response to the pacing threshold with the ability to confirm the rhythm of each beat-by-teat pulse. The AutoCapture span system automatically generates 5V backup pulse when detected loss, can program both single or bipolar.
- Seneability feature - Automatically accepts sensory
- There are warnings to be programmed tachycardia.
- Ventricular Intrinsic Preference - Priority is given to interior transmission.
- The feature of AF Suppression fibrillation
- Save the center of the heart inside the heart chamber up to 14 minutes
- Weight 20g, volume 10.4 cc
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
16 |
02 -chamber pacemaker has a pacemaker |
3 |
Set |
- Allow 3 Tesla 3 Tesla to have no limited areas.
- 8 -year warranty and 100% battery warranty in the first 5 years and 50% decrease in the next 3 years.
- It is possible to activate and turn off the MRI mode with a handheld device (SJM MRI activator). MRI scan can be implanted immediately after transplanting.
- Invisilink wireless communication, combined with Merlin@home and Merlin.net patient tending device to allow daily tracking of the machine.
-AutoCapture pacemaker system allows maximum response to the pacing threshold with the ability to confirm the rhythm of each beat-by-teat pulse. The AutoCapture span system automatically generates a 5V backup pulse when the phase is lost, can program the single or bipolar.
- Seneability feature - Automatically accepts sensory
- The feature of AF Suppression fibrillation
- Corvue feature monitoring pulmonary edema by monitoring the resistance penetration of the chest and allowing patients and doctors to choose a warning.
- Weight 20g, volume 10.4 cc
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
17 |
The 1 -chamber pacemaker has a pacemaker to meet the movement, allowing the whole body |
2 |
Set |
- Allow 3 Tesla 3 Tesla to have no limited areas.
- 10 -year warranty and 100% battery warranty in the first 6 years and 50% gradually decreased in the next 4 years.
- It is possible to activate and turn off the MRI mode with a handheld device (SJM MRI activator). MRI scan can be implanted immediately after transplanting.
-AutoCapture pacemaker system allows maximum response to the pacing threshold with the ability to confirm the rhythm of each beat-by-teat pulse. The AutoCapture span system automatically generates 5V backup pulse when detected loss, can program both single or bipolar.
- Save the center of the heart inside the heart chamber up to 14 minutes
- Weight 19g, volume 9.7 cc
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
18 |
The 1 -chamber pacemaker has a fibrillation that allows the body to take a whole body |
3 |
Set |
- 10 -year warranty and 100% battery warranty in the first 6 years and 50% gradually decreased in the next 4 years.
- The device is ready for MRI scan with a magnetic strength of 1.5 Tesla. MRI scan can be implanted immediately after transplanting.
- Parylene coating against scratches of electric wires.
- The algorithm detects the dynamictx that automatically changes the shocking configuration to ensure that the high voltage treatment is still provided when the current is detected.
- Cold Can Programming provides additional shock vector RV-SVC in case of a shocking electrode wire
- Shockguard function helps to reduce shock
- Suseability function helps to relieve the wrong wave t
- Compatible with standard shock power cord DF4
- Corvue function tracking chest resistance helps detect pulmonary edema
- Farfield MD feature helps to distinguish VT and SVT
- Function of pacing cutting ATP tachycoon before charging and while charging in the VF region
- Ability to monitor the ST difference allows continuously understanding the events of the difference of ST segment, related to ventricular arrhythmia.
- Shocking energy 36J
- Deft Response technology offers non -invasive optimal options to treat high DFT shock threshold.
- Use QHR battery
- Weight 67g, volume 30 cc
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: G7
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
19 |
2 -chamber pacemaker has a response, compatible with MRI, enduring |
15 |
Set |
- Compatible with MRI body scan
- IS-1 connection standard
- 8 -year warranty and 100% battery warranty in the first 5 years and 50% decrease in the next 3 years.
- It is possible to activate and turn off the MRI mode with a handheld device (SJM MRI activator). MRI scan can be implanted immediately after transplanting.
-AutoCapture pacemaker system allows maximum response to the pacing threshold with the ability to confirm the rhythm of each beat-by-teat pulse. The AutoCapture span system automatically generates 5V backup pulse when detected loss, can program both single or bipolar.
- Automatic feature set: Venttricular Intrinsic Preference - Priority is given to interior transmission, AF SupPression - Create atrial and sub -compression rhythms - Senseability - Automatically receive feelings
- There are warnings to be programmed tachycardia.
- Save the center of the heart inside the heart chamber up to 14 minutes
- Weight 19g, volume 10.4 cc
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
20 |
The 2 -chamber pacemaker has a pacemaker to meet the movement, allowing the whole body of the whole body |
2 |
Set |
- Allow 3 Tesla 3 Tesla to have no limited areas.
- 8 -year warranty and 100% battery warranty in the first 5 years and 50% decrease in the next 3 years.
- It is possible to activate and turn off the MRI mode with a handheld device (SJM MRI activator). MRI scan can be implanted immediately after transplanting.
-AutoCapture pacemaker system allows maximum response to the pacing threshold with the ability to confirm the rhythm of each beat-by-teat pulse. The AutoCapture span system automatically generates 5V backup pulse when detected loss, can program both single or bipolar.
- Seneability feature - Automatically accepts sensory
- There are warnings to be programmed tachycardia.
- Ventricular Intrinsic Preference - Priority is given to interior transmission.
- The feature of AF Suppression fibrillation
- Save the center of the heart inside the heart chamber up to 14 minutes
- Weight 20g, volume 10.4 cc
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
21 |
The 2 -chamber pacemaker has a shake that allows the whole body to shoot |
2 |
Set |
- 8 -year warranty and 100% battery warranty in the first 5 years and 50% decrease in the next 3 years.
- The device is ready for MRI scan with a magnetic strength of 1.5 Tesla. MRI scan can be implanted immediately after transplanting.
- Parylene coating against scratches.
- The algorithm detects the dynamictx that automatically changes the shocking configuration to ensure that the high voltage treatment is still provided when the current is detected.
- Cold Can Programming provides additional shock vector RV-SVC in case of a shocking electrode wire
- Shockguard function helps to reduce shock
- Suseability function helps to relieve the wrong wave t
- Compatible with standard shock power cord DF4
- Corvue function tracking chest resistance helps detect pulmonary edema
- Farfield MD feature helps to distinguish VT and SVT
- Function of pacing cutting ATP tachycoon before charging and while charging in the VF region
- Ability to monitor the ST difference allows continuously understanding the events of the difference of ST segment, related to ventricular arrhythmia.
- Shocking energy 36J
- Deft Response technology offers non -invasive optimal options to treat high DFT shock threshold.
- Use QHR battery
- Weight 68g, volume 31 cc
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: G7
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
22 |
3 -chamber pacemaker has the function of cardiac re -function, MRI compatibility |
1 |
Set |
• 3 chamber rhythms.
• MRI compatible with 3T body 3t does not limit the time of shooting and height of the patient.
• 4-pole left ventricular electrode, IS-4 standard, with LV2-LL3 electrodes apart ≤ 1.3mm to help reduce diaphragm shock.
• The 4 -pole left ventricular electrode is active in the form of the circuit.
• Create a frequency pace for the atrial chamber to destroy AF/ AF.
• Physiological design - Reducing the overall pressure on the patient's chest.
• Automatically evaluate the threshold of all the vectors of the left ventricular.
• Allow the collection of EGM signals from the machine like the surface ECG.
• Monitoring feature in the lungs to help diagnose heart failure early.
• The feature allows wireless data transfer via Bluetooth connection to smartphones or tablets.
• Provide data on heart activity ≥ 14 months.
• Having the function of suggesting parameters to help programming suitable for patients.
• Machine life ≥ 10.6 years.
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
23 |
3 -chamber pacemaker 3 chamber compatible MRI compatible |
2 |
Set |
- MultiPoint Pacing - Multipoint pulse on the left ventricular heart cycle to improve hemodynamics and clinical response.
- Compatible with resonance shooting from 1.5 tesla, whole body. MRI scan can be implanted immediately after transplanting.
- Compatible with left ventricular wire 4 electrodes, forming 14 rhythmic directions
- SYNCAV CRT technology automatically adjusts the atrial space changes based on the internal transmission of the patient to tweak the synchronous rhythm of the two ventricles.
- 5 -year warranty.
-The Corvue function tracks the chest resistance to help detect pulmonary edema
- The feature of the AF Suppression atrial fibrillation can reduce atrial fibrillation and atrial fibrillation for a long time.
- Save the heart in the heart up to 14 minutes
- The machine has a water drop shape that makes the electrode more easier
- Weight 27g, volume 15 cc
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
24 |
Permanent pacemaker 1 chamber, MRI compatible |
3 |
Set |
• 1 chamber heart rate, responding to movement.
• Machine volume ≤ 9.7 cc.
• Allow 3T MRI 3T to take the time limit for shooting and height of the patient.
• Managing ventricular pacemaker, allowing the amplitude programming to create a safe span of up to 4 times the pace threshold.
• Having the function of suggesting machine programming parameters suitable for each patient.
• Frequency response to magnet when the battery is ≤ 85 cycles/ minute.
• Twisted electrode wire (twisted, collected), bipolar
- Twisted head material: Platinum.
- Silicon material insulated inside and outside: Silicone/polyurethan
- MRI extremely compatible power cord with 3T body.
- Covered steroids
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
25 |
Permanent pacemaker 1 chamber, MRI compatible |
5 |
Set |
• 1 chamber heart rate, responding to movement.
• Machine volume ≤ 9.7 cc.
• Allow 3T-body MRI 3T-unlimited shooting time and height of the patient.
• Managing ventricular pacemaker, allowing the amplitude programming to create a safe span of up to 4 times the pace threshold.
• There is a feature of stabilizing ventricular stabilization when there is a fibrillation/ atrial.
• Having the function of suggesting machine programming parameters suitable for patients.
• Frequency response to magnet when the battery is ≤ 85 cycles/ minute.
• Twisted electrode wire (twisted, collected), bipolar
- Twisted head material: Platinum.
- Silicon material insulated inside and outside: Silicone/polyurethan
- MRI extremely compatible power cord with 3T body.
- Covered steroids
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
26 |
Permanent pacemaker 1 chamber, MRI compatible |
3 |
Set |
• 1 chamber heart rate, responding to movement.
• Machine volume ≤ 9.7 cc.
• Allow 3T MRI 3T to take the time limit for shooting and height of the patient.
• Managing ventricular pacemaker, allowing the amplitude programming to create a safe span of up to 4 times the pace threshold.
• Having the function of suggesting machine programming parameters suitable for each patient.
• Frequency response to magnet when the battery is ≤ 85 cycles/ minute.
• Has HIS/ Left bundle wire with small diameter ≤ 4.1F
- Fixed twisted head increases stability, reduces the risk of broken broken compared
- Designing core wires, the body of the most diameter, the cable between the body minimizes mechanical pressure compared to the wire using Stylet (heterogeneous wire).
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
27 |
Permanent pacemaker 2 chamber, compatible with MRI |
7 |
Set |
• 2 -chamber heartbeat creating, mobility response.
• Allow 3T body MRI scan - Unlimited time for shooting and height of the patient.
• Manage the atrial and ventricular rhythm, allowing the amplitude to create a safe rhythm up to 4 times the pace threshold.
• Having the function of suggesting parameters to help programming suitable for each patient.
• Frequency response to magnet when the battery is ≤ 85 cycles/ minute.
• Battery life ≥ 14.9 years.
• Twisted electrode wire (twisted, collected), bipolar
- Twisted head material: Platinum.
- Silicon material insulated inside and outside: Silicone/polyurethan
- MRI extremely compatible power cord with 3T body.
- Covered steroids
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
28 |
Permanent pacemaker 2 chamber, compatible with MRI |
5 |
Set |
• 2 -chamber heart rate, responding to movement.
• Allow 3T body MRI scan - Unlimited time for shooting and height of the patient.
• Automatically switches the rhythm to AAI/ AAIR when the patient has normal atrial transmission.
• Manage the atrial and ventricular rhythm, allowing the amplitude to create a safe rhythm up to 4 times the pace threshold.
• The automatic feature creates rhythm with high frequency after atrial arrhythmia to reduce rapid recurrence/ atrial fibrillation.
• The fainting prevention of neurological reflexes is based on two methods of detecting a sudden decrease in the heart frequency.
• The function of suggesting machine programming parameters suitable for each patient.
• Frequency response to magnet when the battery is ≤ 85 cycles/ minute.
• Average battery life ≥ 14.9 years
• Twisted electrode wire (twisted, collected), bipolar
- Twisted head material: Platinum.
- Silicon material insulated inside and outside: Silicone/polyurethan
- MRI extremely compatible power cord with 3T body.
- Covered steroids
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
29 |
Permanent pacemaker 2 chamber, compatible with MRI |
8 |
Female |
• 2 -chamber heartbeat creating, mobility response.
• Allow 3T body MRI scan - Unlimited time for shooting and height of the patient.
• Manage the atrial and ventricular rhythm, allowing the amplitude to create a safe rhythm up to 4 times the pace threshold.
• Having the function of suggesting parameters to help programming suitable for each patient.
• Battery life ≥ 14.9 years.
• Has HIS/ Left bundle wire with small diameter ≤ 4.1F
- Fixed twisted head increases stability, reduces the risk of broken broken compared
- Designing core wires, the body of the most diameter, the cable between the body minimizes mechanical pressure compared to the wire using Stylet (heterogeneous wire).
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
30 |
Permanent pacemaker 2 chamber, compatible with MRI |
3 |
Female |
• 2 -chamber heart rate, responding to movement.
• Allow 3T body MRI scan - Unlimited time for shooting and height of the patient.
• Automatically switches the rhythm to AAI/ AAIR when the patient has normal atrial transmission.
• The automatic feature creates rhythm with high frequency after atrial arrhythmia to reduce rapid recurrence/ atrial fibrillation.
• The fainting prevention of neurological reflexes is based on two methods of detecting a sudden decrease in the heart frequency.
• The function of suggesting machine programming parameters suitable for each patient.
• Average battery life ≥ 14.9 years
• Has HIS/ Left bundle wire with small diameter ≤ 4.1F
- Fixed twisted head increases stability, reduces the risk of broken broken compared
- Designing core wire, body with the most diameter, the cable between the body reduces mechanical pressure compared to the wire using Stylet (wire)
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
31 |
Permanent pacemaker 3 chamber has the function of fibrillation and cardioma, MRI compatibility |
1 |
Set |
• Create rhythm, re -sync 3 heart chamber and dehumidify heart, standard electrodes DF1 or DF4.
• Allow MRI 1,5T and 3T MRI scan with unlimited shooting area.
• Smart shock algorithm allows the wrong shock reduction ≥ 98.5%
• Feature monitoring of epidemic status.
• Allow synchronous shock when ATP is not effective
• Bluesync technology uses Bluetooth to communicate with equipment management application, patient, remote connection.
• Physiological designs minimize the pressure on the skin
• Feature stabilization of ventricular rhythms/atrial fibrillation
• Allow the installation area to distinguish the tachycardia on ventricular ≤ 240ms in the vibration detection area.
• Set the QRS sampling to distinguish SVT from VT from ≥ 6 different sources
• Allow 2 optical options to receive sensuality & right ventricular rhythms.
• Automatically pace after VT/VF shock up to ≥ 8v
• Multi-point pacing provides 2 LV pulses for each span, with a programmable V-V, up to 2 rhythmic vectors.
• Allow 16 left ventricular vector programming
• Automatically provides information from all left ventricular rhythms to help choose the best therapy for patients.
• Left ventricular electrode 2 polar, IS-1 or 4 polar standard, IS-4 standard,
• The four -pole left ventricular electrode is active in the form of the circuit, there are 2 poles apart ≤ 1.3mm to help reduce nervous stimulation.
• Average machine life ≥ 9.5 years
• Maximum shock energy ≥ 40J
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: Europe
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
32 |
Permanent pacemaker 3 chamber has the function of cardiac and fibrillation, MRI compatibility |
1 |
Set |
• 3 chamber rhythms, sterilized.
• MRI compatible with 3T body 3t does not limit the time of shooting and height of the patient.
• Physiological design - Reducing pressure on the patient's skin.
• Smart shock feature helps prevent shock.
• 4-pole left ventricular electrode, IS-4 standard, with LV2-LL3 electrodes apart ≤ 1.3mm to help reduce diaphragm shock.
• Four -pole left ventricular electrodes active in the form of twist into the wall.
• DF4 sterilization wire, Silicone insulating, PTFE, etFe, dexamethasone acetate and dexamethasone sodium phosphate.
• Automatic feature to measure the threshold of all vectors that create left ventricular rhythms.
• The feature suggesting the optimal setting parameters of the heart re -reducing the programming of AV and VV is not suitable.
• Automatically evaluate the threshold of all the vectors of the left ventricular.
• Monitoring lung fluid helps assess heart failure in patients.
• Providing patient clinical data ≥ 14 months.
• Having the function of suggesting parameters to help programming suitable for patients.
• Maximum stimulation amplitude ≥ 8V.
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
33 |
Permanent pacemaker has a fibrillation, compatible with MRI |
2 |
Set |
• Create 1 chamber beat, have drilling, standard DF4.
• Compatible with 3T body full body shot - unlimited area of shooting area, shooting time, height of the patient.
• Physiological design - Minimize pressure on the patient's chest.
• Right -sealed vector ≥ 2 types - Provide non -invasive options to handle cases of T wave takes and R wave amplitude decreases.
• Automatically convert the rhythm exceeding the frequency before and while charging.
• The wire warning feature has problems - Helps reduce shock by extending VF detection time.
• The patient's clinical data provision feature ≥ 14 months.
• SVT detection prevention feature like VT by comparing the shape of each QRS of the tachycard with the sample, allowing the doctor to evaluate the sample and take a new sampling at the present time.
• The function of suggesting parameters helps to program the machine suitable for each patient.
• Machine life up to ≥ 11 years.
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: Europe
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
34 |
Permanent pacemaker has a fibrillation, compatible with MRI |
1 |
Set |
• Create rhythm and deformity, 1 chamber, standard DF4/DF1
• Allow MRI 1,5T and 3T MRI scan with unlimited shooting zone
• Smart shock algorithm allows the wrong shock reduction ≥ 97.5%
• Bluesync technology uses Bluetooth to communicate with equipment management application, patient, remote connection
• Physiological designs minimize the pressure on the skin
• Feature stabilization of ventricular rhythms/atrial fibrillation
• Allow the installation area to distinguish the tachycardia on ventricular ≤ 240ms in the vibration detection area.
• Set the QRS sampling to distinguish SVT from VT from ≥ 6 different sources
• Allow ≥ 2 options to program the right to receive and create right ventricular rhythms
• Automatically pace after VT/VF shock up to ≥ 8v
• Maximum shock energy ≥ 40J
• Machine life ≥ 13.6 years
* The bid company must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: Europe
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
35 |
Permanent pacemaker has a fibrillation, compatible with MRI |
1 |
Set |
• Create rhythm and deformity, 2 chambers, standard DF4/DF1.
• Allow MRI 1,5T and 3T MRI scan with unlimited shooting zone
• Smart shock algorithm allows the wrong shock reduction ≥ 98.5%
• Allow synchronous shock when ATP is not effective
• Bluesync technology uses Bluetooth to communicate with equipment management application, patient, remote connection
• Physiological designs minimize the pressure on the skin
• Feature stabilization of ventricular rhythms/atrial fibrillation
• Allow the installation area to distinguish the tachycardia on ventricular ≤ 240ms in the vibration detection area.
• Set the QRS sampling to distinguish SVT from VT from ≥ 6 different sources
• Allow ≥ 2 options to program sensitivity & right ventricular rhythms.
• Automatically pace after VT/VF shock up to ≥ 8v
• Average machine life ≥ 11.9 years
• Maximum shock energy ≥ 40J
* The company participating in the bid must have a commitment to provide programming machines for checking during and after placing a permanent pacemaker for patients.
* Product origin: Europe
* Standard: ISO 13485, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1/Box |
||
36 |
The ball is high pressure on the high pressure of peripheral vessels |
24 |
Female |
The ball is high in pressure.
System design: Over the wire.
Balling technique: 3 sides (diameter 3mm-9mm), 5 sides (10mm-12mm).
Glossy material: Nylon/Pebax.
Ball diameter: 3mm, 4mm, 5mm, 6mm, 7mm, 8mm, 9mm, 10mm, 12mm
Shade length: 20mm, 40mm, 60mm, 80mm, 100mm.
System length: 40cm, 75cm.
Marker: 2 markers blocking radiation, ensuring the exact position of the ball.
Maximum pressure: 27ATM.
Conductor system: 0.035 ".
* Product origin: Europe
* Standard: ISO 13485, CFS, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
37 |
The ball is hot, the technique is arranged in 3 edges |
24 |
Female |
System design: Over the wire.
Gloss: Controlled Compliance (3 -sided technique).
Glossy material: SCP (Semi-Crystallline Polymer).
Cover: Hydrophilic.
Ball diameter: 1.5mm, 2mm, 2.5mm, 3mm, 3.5mm, 4mm.
Shiny length: 20mm, 40mm, 70mm, 100mm, 140mm, 180mm, 220mm.
System length: 90cm, 120cm, 150cm.
Marker: 2 stereotyped marker.
Wire system: 0.014 ".
* Product origin: Europe
* Standard: ISO 13485, CFS, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
38 |
Peripheral artery ball |
54 |
Female |
The peripheral vasodilation is used to spend a narrow position in the renal artery, thighs, and under the pillow, nylon/ pebax material, semi -elastic ball, covered with Hydrax Plus water. Including 5 points for contrast:
Ø ≤ 2.0mm, length≤ 20mm: 1 point marking tungsten contrast.
Ø ≤ 2.0mm, Length> 20mm: 2 points for contrast tungsten.
Ø ≥ 2.5mm: 2 points for contrast PT/IR Catheter OTW.
- Compatible conductor: 0.014 ", 0.018", 0.035 "
- The corresponding input section: 0.017 ", 0.019", 0.036 "
- The cross section through the minimum lesions corresponding: 0.021 ", 0.029", 0.057 "
- Common pressure: 6/7 ATM
- Maximum stress of tension: 16 atm
- Average ball pressure: 20/22/23 atm
Size:
- Length of catheter (cm): 80, 100, 140, 150, 200
- Diameter (mm): 1.25, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8, 9, 9, 10, 12.
- Length (mm): 10, 15, 20, 40, 60, 80, 120, 150, 200.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
39 |
Paclitaxel peripheral pills |
54 |
Female |
Paclitaxel and Shellac covered with 50%: 50% Nano Transfertech. Palitaxel concentration is 3µg/mm².
Includes 2 points that signs platium/ Iridium contrast.
- Nylon/ Pebax glossy material for sale.
- Compatible conductor: 0.014 ", 0.018", 0.035 "
- Catheter OTW
- Common pressure: 6/7 ATM
- Maximum tension pressure: 14/16 ATM
- Average ball pressure: 20/22/23 atm
Size:
- Length catheter (cm): 80, 100, 140, 150
- Diameter (mm): 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0, 6.0, 7.0, 8.0
- Length (mm): 20, 40, 60, 80, 120, 150, 200
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
40 |
Vein shadow |
30 |
Female |
- The ball is designed for pelvic veins and is widely used with large diameter. Use a wire 0.035 ".
- Two spots for contrast to determine the working length of the ball and support the right place to place the lesion.
- Diameter 14-18mm, length 2cm, 4cm, 6cm. Diameter 20-26mm, length 2cm, 4cm.
- Catheter length: 80 /120 cm.
- Use road opening tools: 7f/8f/9f/10f/12f
- The ball has a normal working pressure of 4 - 6atm, the ball has a small diameter of the maximum pressure up to 18atm
* Product origin: G7
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
01 pc/box |
||
41 |
Peripheral blood vessel shadow |
24 |
Female |
- Peripheral blood vessel ball has 2 μg / mm2 paclitaxel and polysorbate / sorbitol using 0.035 "wire.
- Normal working pressure 6 - 7 atm; The ball has a small diameter of up to 12 atm.
- The ball diameter is about 4 - 10 mm and 12mm
- The length of the ball is about 20 - 150 mm depending on the size of the ball diameter.
- Length catheter 75 /100 /130 cm.
- Markers is designed on the axis of a catheter of 1cm, increasing efficiency during surgery.
* Product origin: G7
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
42 |
Peripheral blood vessel shadow |
24 |
Female |
The peripheral blood vessel ball has 2 μg/mm2 paclitaxel and polysorbate/sorbitol, using a 0.014 "conductor.
- Ball diameter: 2 - 4 mm.
- Shiny length: 40,80,100,120,150 mm.
- Catheter length: 100/130/150 cm.
- Markers (Markers) increases efficiency during surgery.
- ISO or FDA standard (US Food and Drug Administration) or CE standard (Europe)
* Product origin: G7
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
43 |
Peripheral blood vessel shadow |
24 |
Female |
Pebax material - Transpax technology coating helps to release the drug effectively into the tissue, 2µg/mm² density. (1+2)
- The diameter of about 2-8mm (1)
- The length of about 30 - 200mm (1)
- Conductive conductor: 0.014 "/0.018" (1)
- There are two strips of contrast (one nearby, one far away) (2)
- System length: 80cm, 90cm, 135cm and 150cm. The catheter has a 90 cm operating length with a highlight range at 50 cm and two markers at 60 cm. The catheter has a 150 cm operating length with a strip at 90 cm and two markers at 100 cm. (2)
- Maximum pressure ≤ 14 atm.
* Product origin: Europe
* Meeting standards: CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
44 |
Peripheral blood vessel shadow |
24 |
Female |
Paclitaxcel (anti-proliferation) and Butyryl-Tri-Hexyl Citrate (BTHC) with LUX coating technology to increase the effectiveness of drug release into blood vessels, with the density of drug coverage is 3µg/mm².
The ball diameter is about 2mm-7mm.
The length of the ball is about 40mm-120 mm.
System length: 90cm, 130cm, 150cm.
Marker: 2 stereotyped marker.
Broken pressure: 15ATM (Ø 2.0mm-5.0mm), 12ATM (Ø 6.0mm-7.0mm).
Conductor system: 0.018 ".
* Product origin: Europe
* Standard: ISO 13485, CFS, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
45 |
Peripheral blood vessel ball |
54 |
Female |
- Peripheral blood vessel ball, using wire 0.014 ".
- Normal working pressure 6 ATM, maximum explosive norm of 15ATM/16ATM depending on the size of the ball.
- The ball diameter is about 1.5mm - 5mm
- The length of the ball is about 2 - 30 cm depending on the diameter of the ball.
- Use Sheath 4F/5F.
- Catheter length is about 150 cm.
- Ultra-Cross ™ dual-dual-hydrophilic coating (hydrophilic) is designed to reduce friction.
- Designing checker ™ Flex helps the ball easily bend gently in the shape of the lesions.
* Product origin: Europe
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
46 |
Peripheral blood vessel ball |
72 |
Female |
- Peripheral blood vessels use 0.035 "wire.
-Normal working pressure 8 ATM for diameter from 3mm-7mm and 6 ATM for diameter from 8mm-12mm. The pressure of broken ball can be up to 21 atm for small diameter balls.
- Diameter 3 - 10mm and 12mm
- Length 20 - 300 mm depending on the size of the gloss.
- Catheter length: 75 /130 cm.
- Use the road opening tools 5f / 6F / 7F.
- Markers is designed on the axis of a catheter of 1 cm, increasing efficiency during surgery.
* Product origin: Europe
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
47 |
High -pressure peripheral blood vessel ball |
24 |
Female |
- High pressure peripheral blood vessels, using 0.035 "wire.
- Normal working pressure 8 atm. The maximum breakage pressure is up to 40 atm for 4-7mm diameter.
- Ball diameter: 4 - 10 mm and 12 mm
- Length catheter 50 /75 cm.
- Shiny length: 2 - 10 cm depending on the diameter of the ball.
- Use the open road (sheath) with a length of 6F/7F/8F depending on the length and diameter of the glossy.
- The ball is made of composite material with a more durable fiber design.
- Ultra Non-Compliant technology (non-elastic) to create optimal tension (8- 40 atm) to treat damage positions that are difficult to treat but do not break the ball.
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
01 pc/box |
||
48 |
Peripheral hot ball |
54 |
Female |
Consciousness and kidney artery
Rapid-Exchange design. Material glossy: duralyn ™
Ball diameter: 4, 4.5, 5, 5.5, 6, 7 mm
Shading length: 15, 20, 30, 40 mm
Common pressure: 10 ATM
The pressure causes the ball up to 14 atm
Average time pump 3s, discharge ball 5s
Diameter of the pipe body: 3.3 f
Few length of the catheter: 142 cm
Compatible sheath: 4-5 f
Compatible conductor: 0.014 ”
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
49 |
High pressure a coronary pressure on the technology of 2 -layer Hydrophilic and Hypotube Design |
300 |
Female |
- 2 -layer Hydrophilic technology with outer Glide ™ ultrasound and internal Fast ™. Nylon material 3 folds, hypotube design body.
- Tip profile 0.016 '', Crossing profile 0.023 ".
- Two markers with PT/IR material, the ball expands 0.55%.
- Diameter of about 2.0mm - 5.0 mm. The length is from 6mm - 30 mm.
- NP: 12ATM; RBP: 22ATM (2.0-4.0mm), 20ATM (4.5-5.0mm)
Product origin: Europe
* Meet the CE MDR standard by the Netherlands BSI (approved by the European Health Agency (EMA)).
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
50 |
Normal pressure a coronary pressure |
300 |
Female |
Glossy material: nylon/ pebax
Ball diameter (crossing profile): 0.0216 inch (Ø1 mm), 0.0306 inch (Ø3 mm)
The tip is 1.5-2.5mm long.
TIP (TIP Entry Profile): 0.0164 inch (Ø1 mm)
P-P-tuner design increases thrust & twisted
The ball diameter is about 1 - 4 mm.
The length of the ball is about 5 - 30 mm.
Normal pressure: 6 ATM.
Pressure causing ball broken: 14 - 16 atm
Number of glossy folds: 2-3
Hydro-X water coat (tip far away to Exit Marker of the conductor), Invio water resistance (in the tube)
Few length of the catheter: 140 cm.
* Meet the standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
51 |
Liquid clogged substance |
100 |
Female |
- Evoh liquid clogging agent (Ethelene vinyl alcohol) dissolved in DMSO (Dimethylsulfoxide), tantalum powder increases contrast.
- Indications for embolism of peripheral and cerebral vascular lesions including intravenous and blood tumors.
- 12CP viscosity (4% Evoh) and 18CP (5.3% Evoh) corresponding to the concentration of the clogged substance.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
52 |
Roll the cerebral circuit and peripheral circuit |
300 |
Female |
- Catch 3D and 2D (helical)
- Catch Platinum, Size: 0.010 inch, 0.012 inch, 0.014 inches
-The diameter of about 1-20 mm, about 1-50 cm long
- SR wavy wire technology inside filled the empty space and the minimum possibility
- Diverse softness of coil: silkoft, extraSoft, Soft, Mediumsoft, Standard
- Wire length 187cm
* Product origin: G7
* Meet the standard: ISO 13485 and FDA 510K (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
53 |
Despite the hole of the Titanium coating, with the drop cable despite creating an angle of 50 degrees |
5 |
Female |
- The connection point between the drop cable, though the marbles help to lock the safety, suitable for anatomy. Drop even easily and quickly.
- Biological compatibility pieces show that closing the hole is effective instantaneous
- Nitinol alloy is covered with Titanium, showing maximum biological compatibility and minimizing Nikel release.
- The knitting technology does not knob and minimize the material of the left atrial disk and gives better endometrization.
- Size about: 18, 25, 30, 35.
* Product origin: G7
* Standard: ISO 13485, CFS and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
54 |
Despite closing the Titanium covered tuse |
70 |
Female |
- Technology of knitting and optimizing and minimizing the material of the left atrial disk, a single knob.
- Nitinol alloy is covered with Titanium, showing biological compatibility and minimizing Nikel release.
- Pet pieces allows fast endometrization.
- The connection point between the drop cable, though the marbles help to lock the safety, suitable for anatomy. Drop even easily and quickly.
- Size: about 4 - 40 mm (especially sizes 7.5, 10.5, 13.5, 16.5, 19.5)
* Product origin: G7
* Standard: ISO 13485, CFS and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
55 |
Despite closing the loss of Titanium 1 knob |
5 |
Female |
- Whether the ventricular septal is designed with a plate and one body.
- The knitting technology creates softness and does not cause tissue damage.
- Wide body for safe sticking.
- Technology of knitting without a knob, minimizing materials, less protruding.
- Delivery Systems system is small.
- Easy to locate and collect parachute.
- Size about: 4,6,8,10,12.
* Meet the standard: ISO 13485 and CFS
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
56 |
Even if closed arterioscleros, Titanium coverage, with parachute drop cable |
5 |
Female |
- Despite being popular in two types of stems: standard body and long body.
- Despite the small aortic profile, no far -headed knob.
- Design body, although avoiding the risk of thrombosis.
- Create the force of clinging to the pulmonary artery at the end of the ductus arteriosus.
- With a special knitting structure, flexible and adaptable.
- Size:
+ Standard body has sizes: 5,6,7,8,10,12,15,18. Length of about: 4.25-16mm
+ Long body has sizes: 5,6,7,8,10. The length of about: 7-10.50mm
* Standard: ISO 13485, CFS and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
57 |
Treatment for neurological vascular intervention |
30 |
Female |
- Nitinol structure and self -extracted stent frame help treat stenosis of intracranial atherosclerosis.
- Minimum blood vessel diameter: 2.5 mm, 3.5 mm
- Maximum blood vessel diameter: 3.5 mm, 4.5 mm
- Stent diameter: 4 mm, 5 mm
- Stent length: 15 mm, 20 mm, 25 mm, 30 mm
- Compatible catheter: 0.0165 inch/ 0.017 inches
- HPC coating technology simulates glycocalix (lining on the inner surface of the blood vessel cells) to bind covalent with the surface of the stent, reducing the formation of thrombosis.
* Product origin: G7
* Standard: ISO 13485 and CE in the European Union
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
58 |
Carotid artery holder |
150 |
Female |
- Stent Circuit Nitinol material, RX system
- About 5 - 10 mm in diameter
- The length is about 20 - 40 mm
-Crossing profile: 0.065 ”(5 mm-8 mm), 0.078” (9 mm-10 mm)
- Compatible conductor 0.014 "and blood vessels from 3-9 mm
- Few length of the catheter: 135 cm
-Peak-to-Valley design with 18 segments "V" 2mm, every 3 "v" will have 1 north bridge connection.
- Stent self -approaching the wall thanks
- Clinical trial with more than 22,667 patients (NC Sapphire 167; Cases-PMS 1492; Sapphire WW 21,008)
* Standard: ISO 13485, CE (Europe) and FDA 510K (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
59 |
Artery holder with EPTFE bag |
24 |
Female |
- The artery holder has an Eptfe layer, covered with a glossy stent, made of new stainless steel material and is covered by two EPTFE layers with a thickness of 10 - 40 µm;
- Improved micro -form Eptfe layer helps limit the proliferation of the endothelial layer of strong blood;
- Designing short polish hats to minimize the risk of the tangled pipe in Kissing Stent technique;
- Stent cover length: 16 - 58mm, vary depending on the diameter of Stent Cover
- Cover stent diameter: 5 - 10 mm and 12 mm
- Length catheter: 80 /135 cm;
- The ball has a normal working pressure of 8 atm and a 12 atm ball breakage pressure;
- Use the road opening tool 6f / 7f / 8f;
- Use wire 0.035
* Product origin: Europe
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
60 |
Peripheral blood vessels |
24 |
Female |
Stent intervention of peripheral blood vessel intervention, hot with balls.
- COBA MATERIALS - CHRIM (L605), Marker on the ball: Platinum/Iridium
- The thickness of the bar against 0.145mm, width of 0.135mm, 0.145mm, 0.165mm
- Diameter: 5-10mm, Length: 18,23,27/28,38,57/58mm
- System length: 75 and 120 cm
- Sheath 6Fr compatible with all sizes
- Indication for the case of de Novo or narrow lesions due to atherosclerosis
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
61 |
Peripheral blood vessels with wrap |
24 |
Female |
- Material: COCR (L605) is wrapped by a layer of Graft Micro-Porous Eptfe 203 ± 25µm thick.
- The diameter is about 5 - 10 mm, the length is about 18 - 58 mm.
- The thickness of the bar against 0.145mm; The width of the bar against 0.135, 0.145 and 0.165 mm.
- Sheath 6F compatibility with up to 8x57mm size.
- Length of catheter: 75 and 120cm
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
62 |
Renal artery heater |
24 |
Female |
Blood vascular bracket on balls used in kidney artery intervention
- Material of stainless steel support frame 316L. Maximum pump pressure 14ATM
- TANDEM design with macro bar system and add close connectors.
- Diameter of about: 4,5,6,7mm
- A length of about: 14.15,18.19mm
- Catheter length (catheter): 90cm, 150cm
- Compatible conductor: 0.018 ''
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
63 |
Peripheral blood vessel racks sprung with balls |
72 |
Female |
Stent design: Double Helix ensures high flexibility, homogeneous circuit coverage and excellent compatibility.
System design: Rapid Exchange (RX).
Material: Cobalt Chromium (L605).
Stent body thickness: 120µm (diameter 4.5mm-5mm), 140µm (6mm-7mm diameter).
Cover: Probio (Amorphous Silicone Carbide).
Diameter of about: 4.5mm, 5mm, 6mm, 7mm.
The length is about: 12mm, 15mm, 19mm.
System length: 140cm.
Marker: 2 stereotypical marker (ball), gold at the top (rack).
Wire system: 0.014 ".
* Product origin: Europe
* Standard: ISO 13485, CFS, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
64 |
The circuit button is made from PVA plastic seeds |
24 |
Jar |
Microscopic seeds do not load drugs, used to embowish blood vessels. Polyvinyl alcohol material. Partial sizes of about 45-1180 microns.
* Product origin: Europe
* Standard: ISO, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
2 vials/box
5 vials/box |
||
65 |
Bracket bracket (Stent) blocking cerebral vascular bulge flow |
10 |
Female |
Stent works with the mechanism of self -deployment inside the bulge bag to prevent blood from flowing into the brain vascular pocket.
-There are two shapes: cylindrical shape with a diameter of about 3mm -11mm, a height of about 2mm -9mm; Spherical with a diameter of about 4mm-11mm, the height is about 2.6mm-9.6mm. The metal cover of the stent is about 60%, because the stent center is about 100%. Both shapes have 1 tap of close heads and 1 hollow head, the hollows have a RO indicator.
* Standard: CE belongs to the European Union and FDA (US Food and Drug Administration).
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
66 |
Stent frame (stent) peripheral artery |
24 |
Female |
Blood vessel holder on the ball used in peripheral vascular intervention.
- The material of the bracket (Stent) is made of 316L stainless steel, which is broken by the ball with explosive pressure ≤ 12atm.
- TANDEM Architecture with two alternating stent microphones and macro bars
- Diameter of about: 5,6,7,8,9,10mm
- A length of about: 17-57mm
- Catheter 36cm far -headed with hydrophilic technology with hydropass technology.
- The length of the catheter (catheter) 75cm, 135cm.
- Compatible conductor: 0.035 "
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
67 |
Stent frame (stent) peripheral artery |
24 |
Female |
Paclitaxel peripheral vascular bracket (SFA, Girl)
- Nitinol material (nickel-titan alloy), density of drug cover 0.167 μg/mm².
- Near head and far head are signed by contrast by tantali
- Sutta: 6.7mm
- Length: 40,60,80,100,120,150mm
- Catheter length: 75cm, 130cm,
- SHE such compatible: 6F. Compatible conductor: 0.035 ''
* Product origin: Europe
* Meeting standards: CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
68 |
Bracket frame (stent) small inland circuit, changing the direction of the flow |
15 |
Female |
The stream is braided by 48 fibers. Close the walls of the circuit better thanks to the wide, short flared head at the stent head. Better contrast thanks to the DFT wire along the stent body.
- The normal diameter of the stent is from 2.25 to 3.25.
- The normal length of the stent from 10.5mm to 26mm.
- Especially small structure is compatible with micro catheter. 017 ".
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
69 |
Self -extracted stent frame (stent) changes the direction of the flow |
100 |
Female |
- Stent transfer nitinol and platinum material, braided by 48 strands close to the wall.
- Normal diameter of stent: 3.5mm, 3.75mm. 4.0 mm, 4.25 mm, 4.50mm and 4.75mm.
- Normal length of stent: 15mm - 30mm.
- Diameter after stent: 3.75mm. 4.0 mm, 4.25 mm, 4.50mm and 4.75mm and 5.00mm.
- Length after spray stent: 11.5mm - 21.0mm.
- All compatible with the microplasia with a diameter .021 ".
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
70 |
Bracket frame (stent) is used to get thrombosis in the treatment of brain vessels |
20 |
Female |
-Size: Stent diameter 3mm, 4mm, 6mm, stent length 20mm, 24mm, 40mm for 1.5-3mm diameter circuit, 1.5-4mm, 2-5.5mm.
- Material: nitinol
- Characteristics: Stent takes brain thrombosis with open structure, folding parametric design, self -extract can be completely recovered. There is 1 close -headed marker, 3 or 4 of the first marks, and there are evenly distributed marks along the stent body with a distance of 5 - 10mm.
- Compatible with microchip with a diameter of 0.021 "-0.027".
- Push wire with a diameter of 0.018 "and 200cm long.
* Product origin: G7
* Standard: ISO and CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
71 |
Bracket frame (Stent) changes the flow |
30 |
Female |
- Constructed from nitinol -wrapped DFT platinum wires provides complete visibility
- Compatible microchip ID 0.021 inch.
-In the maximum diameter circuit of 2-3mm, the length of stent is 9-18mm.
-In the minimum diameter circuit 1.75-2mm, the length of stent is 10-25mm.
- Movable wire can move independently to bring safety and accurate positioning
- HPC coating technology simulates after glycocalix (lining on the inner surface of the endothelial blood tissue cells) bonding covalent with the surface of the stent, reducing the formation of thrombosis
* Product origin: G7
* Standard: ISO 13485 and CE in the European Union
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
72 |
Bracket (stent) of self -extracted veins |
24 |
Female |
Venous stent is designed to treat thigh vein without thrombosis and post -thrombosis.
- Unique 3mm flared head is designed to reduce the stent movement and maximize the position of the circuit wall.
- Designed for use in pelvic veins.
- Open structure, flexible design to match the curvature of the circuit while maintaining diameter.
- Stent diameter from 10 - 20 mm
- Stent length ranges from 40 - 160 mm
- Length of catheter: 80 /120 cm;
- Use 8F / 9F / 10F road opening tools
* Product origin: G7
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
73 |
Carotid intervention bracket |
100 |
Female |
The self -hatching artery intervention with Closed Cell design helps increase the ability to cover the vascular wall and prevent atherosclerosis. It is possible to collect stent back after 50%.
- System design: Monorail. The body length is about 135cm.
-Material: made from cobalt-chromium-range-nickel-molypden (often known as elgiloy or conichchrome), containing tantalum core with contrast.
- diameter from 6mm to 10mm.
- The length is from 21mm to 37mm, the maximum length after broadcasting 62mm.
- Compatible conductor 0.014 ".
- Sheath is compatible 5F-8F.
* Product origin: Europe
* Standard: ISO, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
74 |
The artery bracket has a self -wrapped plastic that |
24 |
Female |
- The artery holder has an Eptfe bag, self -extracted
- Made of nitinol alloy (Nickel, Titanium)
- Designing multiple points (Marker) metal (tantalum) at the distance and near the stent.
- Biological carbon layer is designed to reduce platelets in the early stages.
- Cover stent diameter ranges from 6 - 10 mm
- Stent cover length ranges from 30 - 100 mm
- Length of catheter: 80 /120 cm;
- Compatible conductor 0.035 ''
- Use the road opening tool 8f / 9f
* Product origin: G7
* Standard: ISO 13485: 2016, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
75 |
Peripheral artery bracket with wrap |
24 |
Female |
The peripheral stent has a glossy wrap, open eye design and alternate link.
Material COCR L605 frame.
The 2 -layer Eptfe film material has high flexibility, which helps increase the ability to expand compared to nominal diameter. The ability to expand widely: diameter from 5-8mm can bloom to 10mm, diameter from 9-10mm to 12mm. Each Stent end has 3 points that are contrast. Definent pressure of the ball: 9 ATM. Broken pressure: from 13-15 atm. Compatible conductor: 0.035 ". There are two working length options: 80cm and 140cm. Stent diameter: 5, 6, 7, 8, 9, 10mm. Length 17, 27, 37, 57mm.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
76 |
Peripheral artery bracket covered with syrolimus |
24 |
Female |
The peripheral stent under the pillow covered with Sirolimus treatments for serious anemia.
- Material COCR L605 frame. Stent wall thickness: 75 µm - 85 µ. Patriotic concentration: 1.4 µg/mm syrolimus
- Polymer: flourinated acrylate
- Compatible with wire 0.014 ". Compatible with Guiding 5F
- Crossing profle from 0.043 ”to 0.051". 2 Marker contrast (PT-IR)
- Material glossy: nylon and pebax. Semi-compliant elastic ball. Time to discharge ball: 3s
- Common pressure: 9-12 ATM | Broken pressure = 16 atm | Explosion pressure = 22 atm
- The level of jerks of stent <5%. Short contract level after opening Stent <3%
- Stent (mm) diameter: 2.00, 2.25, 2.5, 2.75, 3.00, 3.50, 4.00, 4.50.
- Stent (mm) length: 9, 14, 16, 19, 24, 29, 34, 39.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
77 |
Self -extracted peripheral artery bracket |
24 |
Female |
Use nitinol material. Thickness 180-190 µm.
- Has a handle design with a roll bar to control the release of stent
- Compatible with wire 0.035 "
- Compatible with Introducer 6F
- Compatible pipes 8F
- There are 4 points for contrast at each stent head and 3 points for contrasting on the catheter
Size:
- Length of catheter (cm): 80
- Diameter (mm): 5, 6, 7, 8, 9, 10.
- Length (mm): 40, 60, 80, 100, 150, 200
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
78 |
Self -extracted peripheral artery bracket (long type) |
216 |
Female |
Use nitinol material. Thickness 180-190 µm.
- Has a handle design with a roll bar to control the release of stent
- Compatible with wire 0.035 "
- Compatible with Introducer 6F
- Compatible pipes 8F
- There are 4 points for contrast at each stent head and 3 points for contrasting on the catheter
Size:
- Length catheter (cm): 130
- Diameter (mm): 5, 6, 7, 8, 9, 10.
- Length (mm): 40, 60, 80, 100, 150, 200
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
79 |
Coronary artery bracket with Everolimus coverage |
200 |
Female |
1. Material:
-Stent frame material made of cobalt chromium alloy (cobalt chromt l-605), thickness of 0.0032 ", open form, bending three levels of multi-link (3-3-3), non-linear bonds, Everolimus coverage (1µg /mm2) (works to prevent proliferation without killing cells).
- Polymer structure: fluorinated copolymer
- Stent shadow: Pebax 72D material
2. Size:
- Diameter: 2.0, 2.25, 2.5, 2.75, 3.0, 3.25, 3.5, 4.0mm.
- Length: 8, 12, 15, 18, 23, 28, 33, 38mm.
- Maximum expansion diameter: From size 2.0 -> 3.25mm up to 3.75 mm; From size 3.5 -> 4mm up to 5.5mm
- Crossing section (crossing profile): 0.039 inch (3.0 x 18mm). Tip cross section 0.017 ”(3.0x18mm), working length of catheter 145cm
- Defining pressure 9ATM-12ATM, maximum breakage pressure of 16ATM.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
80 |
Cocr cores covered with syrolimus covered with ABluminal |
100 |
Female |
-Coronary artery stent is made of cobalt-chromium alloy L-605 for sale, open-selling stent, covered with Sirolimus dosage of 1.02µg/mm2
- There is a trapezoidal rod crossbar stent ≤ 75µm, width ≤90µm. Shortening ratio <2% and shrink (recoil) <3%
- Self -eliminating polymer (PLA/PGLA), ABLUMINAL Covered technology (partial coating) thickness <4µm
- Rated pressure ≤ 10atm. Shadow breakage: 16ATM (diameter from 2.25 to 3.5mm).
- Release more than 60% of the drug in 30 days
- Few length: ≥145cm
- Glasses input 0.017 ", cross section: 0.039 ''.
- Diameter: ≤ 2.25mm to ≥ 5.00mm (minimum of 3.25mm, 3.75mm sizes), length: ≤ 8 to ≥ 38mm.
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
01 pc/ box |
||
81 |
Biolimus A9 cylinder bracket frame |
100 |
Female |
Cobalt Chromium coronary stent, covered with Biolimus A9 directly on the surface of the stent is sandy, non -coated with polymer. Drug content: 15.6µg/mm length stent.
- Length from 9mm to 36mm, diameter sizes from 2.25mm to 4.0mm. Stent diameter can reach a maximum of 5.95mm.
- Stent shadow identification pressure ≤ 8atm. Rupture pressure rated ≤ 16atm. The thickness of the bracket bar ≤ 88µm (9 -rim design), ≤ 84µm (6 -rim design). Shortening: ≤ 2.29%. Elastic shrinkage: ≤ 3.87%. The segment s and segment is straight. Eye diameter ≥ 1.58mm.
- Compatible conductor 0.014 "and 5F catheter. Calculate piercing force> 0.67bar or 500mmHg.
* Meet the standard: ISO, CE and FSC in Europe.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
82 |
Everolimus, self -paved coronary bracket, self -consuming polymer |
200 |
Female |
- Everolimus (Everolimus covered with thick Everolimus ~ 1μg/mm2) Platinum chromium frame
- There is a polymer layer covering the surface of the stent.
- The thick stent thickness of 74μm, 79μm, 81 μm.
- The glossy material in Pebax Stent has 2 layers
- There is a Bi-Segment structure
- Bioslide Hydrophilic. There are marked markers of 1mm 1mm.
- Tip profile: 0.017 "
- Diameter: from 2.25mm - 5.0mm; Length: from 8mm - 48mm
* Product origin: Europe
* Meet the standard: ISO 13485, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
01 pc/ box |
||
83 |
Sirolimus coronary cylinder holder frame |
150 |
Female |
- Material: Cobalt Chromium with double biolute and probio coating
- Mills: Sirolimus. Density: 1.4µg/mm²
- Polymer type: self -consumption
- Stent frame thickness: 60 µm (0.0024 inches) with a diameter of 2.25mm -3.0mm, diameter 3.5mm - 4.0mm with a stent bar size 80 µm (0.0031 inch)
- Length ranges from: 9mm to: 40mm
- Diameter ranges from: 2.25mm to: 4.0mm
- Sirolimus cylinder bracket with biolute and probio coating
* Product origin: Europe
* Standard: ISO 13485, FSC, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 pc/ box |
||
84 |
Sirolimus coronary cylinder holder frame |
250 |
Female |
Sirolimus stent on self-digest polymer polymer combined with Anti CD-34 antibody layer actively heals vessels.
Drug content: 5.0 µg/mm. Material: 316L stainless steel
Stent width: 90 µm. Stent thickness: 86 µm
The maximum size of the fox on stent: 4.5 mm
Crossing (stent profile): 0.0361 inch/ 0.91 mm
Capital: Hydro-X
The diameter of about 2.5 - 4.0 mm.
The length of about: 9 - 38 mm.
Radial Strength (compressive resistance)> 25 psi
Foreshortening (ratio of stent length) <1%
Recoil (stent shrinking ratio) <5%
The diameter 2.5-2.75mm is maximum 3.25 mm
The diameter of 3.0-4.0mm is maximum 4.5 mm
* Meet the standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
85 |
Sirolimus coronary cylinder holder frame |
125 |
Female |
Coronus brackets covered with syrolimus and fluorinated acrylate polymers, COCR L605 frame
Stent walls have a thickness: 75 µm - 85µm
Sirolimus concentration: 1.4µg/mm2.
Short shrinkage rate after opening stent: <3%. Ratio ratio: <5%
Stent diameter: 2.00; 2.25; 2.50; 2.75; 3.00; 3.50; 4.00; 4.50mm.
Length: 9; 14; 16; 19; 24; 29; 34; 39; 44; 49mm.
The ability to expand stent: 2.0, 2.25, 2.5 to 4mm; 2.75, 3.0, 3.5 bloom to 5.25mm; 4.0, 4.5 bloom to 6mm.
There are 2 points marking PT / IR radiation on the stent catheter. - TransferWise technology
Glossy material: nylon and pebax, semi -elastic type
Nominal pressure: 9 - 12 atm.
Catheter operates under the RX mechanism, the working length is 142cm, the profile crosses the damage from 0.043 "to 0.051".
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
86 |
Sirolimus crystal bracket frame, LDZ-Link design, self-consumption polymers |
1.000 |
Female |
- Cocr material stent cocr material, 60µm thin stent frame all diameter, coating syrolimus 1.4µg/mm2 has long z -link, 3 -layer polymer coating: PLA, PLCL and PVP self -digesting.
- The shrinking rate <4% & shorten 0%.
- Stent 4 Crown - 6 Crown - 8 Crown depends on the diameter to ensure the stent structure integrity.
- Diameter of about: 2.0-4.5mm, length: 8-48mm.
-NP: 8 ATM (2.00-2.25mm), 10 ATM (2.50-3.00mm), 11 ATM (3.50-4.50mm) and RBP: 16 ATM.
-Maximum expansion: From size 2.0-2.25mm up to 3.25mm, size 2.5-3.5mm up to 4.25mm, size 4.0-4.5mm up to 5.5mm.
- Double platelet anti -platelet drugs may be discontinued after 1 month, proven by random research (RCT).
Product origin: Europe
* Meeting CE standards issued by the agency approved by the European health agency (EMA).
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
87 |
Zotarolimus pills covered |
400 |
Female |
- Zotarolimus coronary supplies bracket (equivalent to 1.6µm/mm²)
- Siner -shaped stent structure
- Stent thickness 81µm with diameter: 2.0- 4.0mm, 91µm with diameter: 4.5-5.0mm.
- Material of the outer shell: COBALT, the inner core is made of platium Irridium. Marker with platinum Irridium. Polimer biolinx coating.
- Diameter ranges from 2.0mm to 5.0mm
* Product origin: Europe
* Standard: ISO 13485, CFS, FDA (US Food and Drug Administration) and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
88 |
Circuit bracket frame |
400 |
Female |
Self -extracted artery artery, Marker Tantalum, the length of the catheter has a 135cm stent, is compatible with a 0.014 "conductor.
- The bracket consists of 02 types: straight and cone (Tapering) suitable for the carotid artery.
+ Straight frame: The diameter is about 6-10mm, length 20,30,40.60mm.
+ The cone frame has 2 types: 2 -headed two -headed diameter of 8mm - 6mm and 10mm - 7mm type corresponding to the length of the stent is 30mm and 40 mm.
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
89 |
Blood vascular bracket frame |
20 |
Female |
- Stent treatment of wide neck bulge combined with metal spiral, nickel titanium material, woven with 16 strands.
- The diameter ranges from 3.5mm to 5.5mm, the length is from 12mm to 75mm.
- Packaging with catheter with diameter .024 ' - .032' '' '
- Good identification thanks to 2 twisted markers on the stent body.
- It is possible to recover the stent when it has been 90%.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
90 |
Small diameter blood vessel bracket |
10 |
Female |
Stent treatment of wide neck bulge combined with metal spiral, nickel titanium material, is woven with 16 strands. Contrast with 2 markers along the body.
- The diameter ranges from 2.0mm to 3.0mm, the length is from 12mm to 35mm.
- It is possible to recover the stent when it has been 90%. Support in the treatment of small blood vessels with a diameter of 1.5mm.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
91 |
Brain blood vessel bracket frame |
400 |
Female |
- Size: diameter from: 3.0mm - 5.0mm. The length is from: 15mm - 30mm.
- Material: nitinol with fibrin-heparin coating.
- Characteristics: Laser self-expanded nitinol bracket frame with fibrin-heparin coating used in intervention to treat narrow intracranial narrow circuit. Stent eye design, good compatibility with blood vessels. The bracket has 3 platinum/Iridium contrast at each and far and far ends. Compatible with a catheter with a shadow of 1.5mm-4.0mm diameter, 8-15mm ball length. Can be recovered after dropping 90% of the length.
* Product origin: Europe
* Meet the standard: ISO 13485 and CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
92 |
Brain vascular bracket with fibrin-heparin coating |
20 |
Female |
- Size: Diameter of about: 3.5 - 6.5mm. The length is about: 15mm - 35mm.
- Material: nitinol with fibrin-heparin coating
- Characteristics: Laser self-expanded nitinol bracket is covered with fibrin-heparin used in the medical intervention of brain enlargement bags. Stent eye design. The bracket has 3 contrast. Compatible with pipe with diameter: 0.0165 " - 0.017 '', 0.021 ''. It can be recovered after 90% of the length.
* Product origin: Europe
* Meet the standard: ISO 13485 and CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
93 |
Blood vessel flow frame |
80 |
Female |
- Size: Stent diameter 2.5mm - 8.0mm; The length is about 10mm - 50mm.
- Material: nitinol material with fibrin-heparin coating.
- Characteristics: The bracket frame shifts the flow used in the treatment intervention for cerebral aneurysm, completely contrast. Nitinol braided wire with Bluexide® technology helps increase biological compatibility and fibrin-heparin anti-thrombotic coating. Compatible with catheter 0.0165 '- 0.017 ", 0.027" and 0.039 ".
* Product origin: Europe
* Meet the standard: ISO 13485 and CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
94 |
The bracket frame changes the flow direction |
10 |
Female |
- Constructed from nitinol -wrapped DFT platinum wires provides complete visibility
- Compatible microchip ID 0.021 inch.
-In the maximum diameter circuit of 3-5mm, the length of stent is 9-30mm.
-In the minimum diameter circuit 2.5-4.5mm, the length of stent is 11-41mm.
- Movable wire can move independently to bring safety and accurate positioning
- HPC coating technology simulates after glycocalix (lining on the inner surface of the endothelial blood tissue cells) bonding covalent with the surface of the stent, reducing the formation of thrombosis
* Product origin: G7
* Standard: ISO 13485 and CE in the European Union
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
95 |
Venous bracket frame |
24 |
Female |
Peripheral vascular brackets for veins are indicated for cases of clogging, obstruction, pelvic thrombosis, thighs.
- Nitinol alloy material, open eye stent design, self-extracted pull-back mechanism (backward)
- Diameter 10, 12, 14, 16, 18 mm long, 60, 80, 100, 120, 150mm.
- Compatible Sheath 10Fr with all sizes
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
96 |
The circuit button material has the function of loading liver cancer treatment |
24 |
Jar |
- Ingredients are many biological compatibility, biological, non -reabsorbing, customized size and can be loaded and washed and washed Doxorubicin or Irinotecan. The circuit beads are produced from Polyvinyl Alcohol (PVA), not absorbed by the body and calibrated correctly.
- 10 ml glass jars containing 2ml of node seeds are stored in 5ml of transport solution
- The process of loading and washing of the drug load is achieved through the reversible sulfonic ion exchange mechanism.
- Chemical loading microscopic beads are dyed green to support visual support during the preparation and loading process, there are 3 types of particle sizes from 70-150µm; 100-300µm; 300-500µm.
- Being indicated for local treatment of malignant liver tumors with many primary and secondary HVT blood vessels, including liver cell carcinoma (HCC) when loaded doxorubicin and liver colon cancer (MCRC) when loaded irinotecan.
- The duration of drug load is about 30-90 minutes depending on the size of the particle when loading with doxorubicin 25mg/ml guarantee ≥ 98% of the corresponding amount of drugs. Control the release of drugs during treatment.
- Beads after loading doxorubicin, Irrinotecan preserved at a temperature of 2-8 degrees Celsius can hold up to 14 days or 7 days if mixed with contrast
- The ability to suck doxorubicin up to 37.5mg/ml of seeds.
- The ability to close Irrinotecan up to 50mg/ml of seeds.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 bottle |
||
97 |
Materials of spherical circuit |
50 |
Jar |
- Material: Acrylic polymer impregnated gelatin.
- Being indicated for use in blood vessels, for the purpose of treatment or surgery in the following procedures:
+ Button of blood vessel hyperlipation tumors, including: uterine fibroids, meninges tumors
+ Prostate artery button
+ Node of venous dynamic malformations
+ Hemostatic button
- Spherical seeds, diverse in size. Dry grain diameter: 40-120µm, 50-100µm, 100-300µm, 300-500µm, 500-700µm, 700-900µm, 900-1200µm.
- The seeds can temporarily compress up to 33% to pass through the smooth catheter.
* Product origin: G7
* Standard: ISO, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box of 1 bottle/ box 1 piece |
||
98 |
Materials for non -loading circuit buttons |
144 |
Jar |
- Hydrogel micro-bridge seeds, inorganic Perfluoro polymer (polyzene ™ -F), insoluble in solvent.
- Particle size is about: 40 µm - 1,300 µm, coded in size.
* Product origin: G7
* Meet the standard: ISO13485, CE/CFS (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 bottle/box |
||
99 |
Materials for liver cancer treatment |
24 |
Jar |
- As a hydrogel micro-bridge, coated with inorganic Perfluoro (polyzene ™ -F), insoluble in the solvent.
- Bring doxorubicin and irinotecan medicine up to 50mg/ 1ml of seeds.
- Fast absorption time, up to 60 minutes.
- Particle size: 40,75,100 µm.
* Product origin: G7
* Meet the standard: ISO13485, CE/CFS (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
01 bottle/box |
||
100 |
Temporary circuit button material |
54 |
Jar |
The temporary circuit material is derived from gelatin, designed tube -shaped tube design with a convenient standard size for immediately use.
- The particle size is about 50-4000 µm, is coded in each size and is correctly calibrated.
- Has good elasticity, biological compatibility, water and absorption in blood vessels.
- In treatment, it will promote the formation of thrombosis in the artery or vein by artificial mechanism to prevent or slow blood flow.
- Volume: 20ml syringe. Each tube contains about 100mg of circuit button material in aseptic condition.
* Meet the standard: ISO, CFS
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/10 vials |
||
101 |
Water intervention conductor |
20 |
Female |
Micro -conductor of water intervention has a diameter of 0.010 ", 0.012". The length of the conductor is about 310cm. The close head is made of stainless steel, the far head is made of nitinol to help shape well against folding. Easily shaped the head from the first version D.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
102 |
Micro -conductor intervention |
120 |
Female |
- Exclusive Actone technology with double spiral structure
- Diameter 0.016inch, Slip coat® water coating on polymer platform length 130, 160, 175cm from the end of the wire corresponding to the length of the conductor 135, 165, 180cm respectively.
- Conductor with stainless steel core.
- Tip nipples have the form: 45 ° curve, double curved and rounded curves.
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
103 |
Micro -conductor intervention super small water |
900 |
Female |
+ Near head made of stainless steel, far away with nitinol.
+ Easily shaped the head from the first version.
The size has at least 04 types:
+ Diameter: 0.007 '', 0.008 '', the length of the micro wire 200cm.
+ Diameter: 0.012 '', 0.014 '', the length of the conductor 220cm.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
104 |
The intervention intervention has a separate head with a conductor |
90 |
Female |
- Micro catheter with the leading micro wire can be separated.
- Outside diameter of 1.2F far, with separate segments: 1.5cm, 2.5cm and 3.5cm. Packed with micro wire .007 ''.
- The outer diameter of 1.5F far, has a separate segment: 1.5cm, 2.5cm, 3.5cm and 4.5cm. Packed with micro wire .008 ''.
- The total length of the pipe is about 167cm.
- Compatible with DMSO.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
105 |
Vascular intervention tube |
150 |
Female |
- Size: Inner diameter: 0.0165 ", 0.021", 0.027 ", 0.039". External diameter (far/ near): 1.9f/ 2.1f, 1.9f/ 2.3F, 2.2F/ 2.6F, 2.4F/ 2.5F, 3.0F/ 3.1F, 4.0F/ 4.1F. Few length: 125cm, 135cm, 145cm, 155cm, 160cm, 167cm
- Material: 2 -layer water coating and braided/twisted rolls, PTFE coating in the pipe.
- Characteristics: micro -catheterization of brain vascular intervention. The straight tip of the tube can be shaped. Number of contrast bumper: 1 sign with a tube 0.027 ", 0.039"; 2 seals with tubes 0.0165 ", 0.021".
* Product origin: Europe
* Meet the standard: ISO 13485 and CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
106 |
Vascular intervention tube |
120 |
Female |
The catheter is used in peripheral circuit intervention and organs:
- Material: nylon braided fiber, far -headed tip covered with 80cm long water. Chemical compatibility with dsmo, lipiodol, chemotherapy, glue and ethanol.
- Length: 110cm, 130cm, 150cm, 165cm.
- Outside diameter: 2.1F, 2.4F, 2.8F. 2.9F.
- Outside diameter near: 2.8F, 2.9F.
- Far away shape: There are straight head forms, 45 degrees curved and swan neck.
- Compatible with clogged materials of up to 900µm in size
- withstand 800psi pressure
- There is a contrast bump at the top of the tip
* Product origin: G7
* Standard: ISO, CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
107 |
Vascular intervention tube |
24 |
Female |
The peripheral vascular intervention with the outer surface of the catheter is covered with hydrophilic hydrogen pass (1), the material is braided with stainless steel wire, suitable for a conductor with a diameter of ≤ 0.018 inches.
- The outer diameter along the length of the tube from 3.0F the stubborn area is nearly 2.4F the soft head.
- The inner diameter of the smallest catheter is in the far and close head area of 0.021 inches.
- Length: 105cm, 130cm, 150cm
- Design 01 contrast point at the distance, compatible with 700 micron spherical particle or 500 micron spherical beads.
- The product also includes a shaped shaft with steam and a rotating hemostatic valve (RHV).
- Transmission pressure ≤ 6895 kpa (1000 psi), static pressure ≤2070 kpa (300 psi).
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
108 |
Catheterization of cerebrovascular intervention |
500 |
Female |
Micro catheter is compatible with DMSO. The head can be bent with steam. The 156cm long type (near/far/far -end diameter is 2.1F/1.6F, with 2 contrast barrier markers), 167cm long (near -far/far diameter is 2.1F/1.3F, with 1 contrast bumper marker).
- Use to drop coil or pump biological clogging.
* Standard: CE belongs to the European Union and FDA (US Food and Drug Administration).
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 1 piece |
||
109 |
Peripheral blood vessel intervention |
120 |
Female |
- Micro -tip 1.7Fr softly sticks to the wire (compatible with 0.016inch wire).
- The catheter is braided by 2 wires (different thickness) to help prevent twisting, anti -stretching pipe and high display.
- Diameter of far/near: 1.7/2.8FR.
- Inside/close diameter: 0.017/0.023Inch.
- The elastic pipe design allows good tactile feedback and ensures evenly.
- Pump pressure up to 1000 psi.
- Water -loving coat: 65cm, 100cm.
- Few length 105cm - 150cm.
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
110 |
Peripheral blood vessel intervention |
120 |
Female |
- The tip of 1.9FR or 2.6FR tube.
- Increased tungsten braided fiber increases the ability to display and maintain the shape of the heart in the tube.
- Pump pressure up to 1000psi.
- Water coating: 65, 100cm.
- Diameter of far/near: 1.98/2.8 Fr (Soft), 2.6/2.8FR (HF).
- Diameter of: 0.022inch (Soft), 0.027inch (HF).
- Maximum wire: 0.018inch (Soft), 0.021inch (HF).
- Few length 105cm - 150cm.
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
111 |
Micro catheter intervention micro brain circuit 2 Markers drop coils |
50 |
Female |
- The catheter is covered with hydrophillic water in the distance and covered PTFE in the pipe, increasing the ability to navigate.
- The size of the segment is nearly 2.2F-4.0F, the distance is from 1.9F-3.8F.
- Compatible with wires with diameter. 014 '' - .035 ''.
- The length of the catheter is about 135cm, 155cm.
- Format with straight tip (D) and curved head (MP).
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
112 |
The catheter supports peripheral vascular intervention |
96 |
Female |
Supporting peripheral vascular intervention with multi -layer body with optimal stability helps increase durability, ability to push and piercing.
- Tungsten coating and tip marker platinum provides absolute visibility
- Diverse design suitable for all cases of peripheral intervention.
- Covering long hydrophilic water layer: 40cm; 60cm; 100cm and 120cm.
- Approximate diameter: 2.6f
- Diameter outside the far end: 1.6f - 1.8f
- Compatible with micro wire: 0.014 "and 0.018"
- Length: 60cm; 70cm; 90cm; 135cm; 150cm.
- Withstand pressure up to 1,000 psi.
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 box |
||
113 |
Micro catheter |
24 |
Female |
The shinka tube design allows both directions through difficult lesions, sustainable metal tip tips penetrate 0.020 inch (0.5 mm), 100 mm tubular segment from high support tip.
External diameter (tip/ distal): 1.5f/ 2.3f
0.014 inch compatible conductor
Patriotic coating 23, 30, 70, 115cm
Few length: 60, 90, 135, 150 cm
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/ box |
||
114 |
Micro catheter is used in neural vascular intervention |
100 |
Female |
Small catheterization interves neurological vascular, compatible with DMSO. The outer diameter of the near and far segment is 2.5F (0.85mm) - 2.2F (0.74mm). The inner diameter is. 017 ", there are 4 transition areas. Constructed by 8 nitinol wires, 1 stainless steel wire, 2 markers at the beginning to increase the ability to contrast. The total length of the pipe is about 160cm, easily shaped the tip of the catheter from the straight first version.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
115 |
Micro catheter drifts along the flow of blood vessels |
300 |
Female |
- Micro catheter is used in cerebral vascular intervention.
- Microchip material is a combination of polyurethan alloy (PUR) and Torver.
- Size outside the distance from 1.2F - 1.8F, compatible with micro wire with diameter .007 " - .1010".
- The length is about 155cm, 165cm.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
116 |
Metal spiral (coil) causes blood vessels of sizes |
300 |
Female |
- The coil system is separated by cable connected to the coil cutter. The point separated by short electricity is in .002 " - .003" "
+ Catch 10: Catch diameter: 1mm - 10mm. Catch length: 1cm - 34cm.
+ Catch 18: Catch diameter: 06 mm- 15mm, coil length: 16 cm - 50 cm.
- 0.12 "push shaft design helps to move softly in the microscope.
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
117 |
The peripheral metal torque |
100 |
Female |
- Platinum / Tungstène -type spring -shaped metal torque, covered with synthetic fibers, with a diameter of 0.015 ".
- Catch is designed to treat clogging in diseases: venous dynamic deformities, venous venous venous venament ..... of the brain and peripheral system. The coil diameter is about 2mm -7mm, the coil length is about 25mm - 60mm.
- Compatible with wire 0.021 ".
- Compatible with microplasia with a diameter of 0.6mm to 0.7mm.
* Product origin: Europe
* Meet the standard: CE/MDR of the European Union.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/5 pieces |
||
118 |
The new generation of metal coils (coils) |
900 |
Female |
- Metal spiral (coil) used in peripheral and nervous vascular intervention.
- Platium-tungsten alloy material, marked as Platinum-Iridium
- Fiber diameter:.
+ Catch. 010 '', .111 '', .112 '' '' Watch diameter: 1mm - 10mm. Catch length: 1cm - 34cm.
+ Catch fibers .013 'and .014' ': Watch diameter: 05 mm- 24 mm, coil length: 10 cm - 65cm.
- Quickly split under 01 second when connected to the coil cutting tool.
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
119 |
Cerebring drainage set has a pressure scale according to the flow |
150 |
Set |
- The system includes: 700 ml fluid bags, main blocking systems, flow monitoring columns, trocar 15cm. 35cm long ventricular catheter is covered with barium, in diameter of 1.5mm, an external diameter of 2.8mm, a hole size 1.1mm, 3 points marking a length of 5.10.15cm, 4 rows of 4 holes of 2.4cm long drain.
- Two injection sites without rubber latex allows CSF sampling and inner medicine.
- The cone shape of the 50 cc compartment chamber helps to accurately measure the liquid.
- Hydrophobic filter on a drip chamber works as microorganism barriers and ventilation air even after exposure to fluid.
- The bag contains fluid with a measurement of the amount of melting, removable.
- Packaging, no fire.
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 set/ box |
||
120 |
The set of needles and pumping cement into the vertebra body |
10 |
Set |
Including:
- 3 needles contain and push cement:
+ Cement push needle: 2.9mm diameter, 230.3mm long, working length 215.0mm
+ Kim contains cement: 3.5mm diameter, 213.3mm long, working length 188.0mm
- 1 needle creating empty bone cavity: 3.5mm diameter, 232mm long, working length 201.2mm
- 1 needle and expansion:
+ Metallic spine needle: 4.3mm diameter, 166.3mm long, working length 135.0mm
+ Expanded needle: 3.8mm diameter, 175.6mm long, working length 159.8mm
- 1 needle:
+ Diameter 3.0mm, 144.8mm long, working length 109.5mm
+ Diameter 1.85mm, 152.7mm long, working length 136.0mm
- 2 wires: 1.8mm diameter, 270.0mm long
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
121 |
Set of ventricular artificial drainage valve - peritoneal |
50 |
Set |
- Size 36 x 13 x 6mm, with pressure 1, 1.5, 2. Elastomer silicone and polypropylene material.
- Catheter covered the Barium layer with tip marked with tantalum, helping to see clearly under X-ray. Markers The length marks the piercing depth during the process of stabbing. At the right corner clamp, it helps prevent brain drainage conductor at the drainage hole. The inner catheter is 1.3mm and the outer diameter is 2.5mm.
- 23cm long cerebral catheter with 4 rows of 8 holes of epidemic, 90cm long abdominal catheter with 4 exhaust ditches 90 degrees apart.
- Non -metallic materials should not be affected when CT scan, MRI
- There is a Siphon phenomenon control device (too much fluid due to the impact of gravity on the water column in the abdominal catheter) allows patients to maintain intracranial pressure without being affected by the flow rate of the cerebrospinal fluid or the patient's posture.
* Meeting standards: CE (Europe) and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 set/ box |
||
122 |
Cervical spinal disc |
12 |
Female |
- Material: Peek
- There are 2 points marked in titanium
- The distance from the front to the marker point: 0.95mm- 1.2mm
- The distance from the back to the marker: 1.3mm- 1.75mm
- There is a fixed nail
- There is a gap to divide the load force
- Sawing decay: ≥0.5mm
- There is a large bone compartment
- Bone volume: ≥0.43cc and ≤1.00cc
- Size:
+ Height: in the range of 5-8mm
+ Depth: In the range of 12-14mm
+ Width: ≥15mm and ≤17mm
- Genuine sterilization packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
123 |
The cervical spine disc has screw |
12 |
Set |
Including: 1 disc + 2 screws
Disc:
- Material: titanium
- There is a large empty compartment to stuff the bones
- There are 2 screw holes with anti -screw design system design
- Equipment is equal to 0
- Raise: 7 degrees
- Size:
+ Height: in the range of 5-10mm
+ Depth: ≥12mm and ≤14mm
+ Width: ≥15mm and ≤17mm
+ There are at least 24 sizes
- Bone volume: ≥0.25cc and ≤0.80cc
Screw:
- Material: titanium
- Screw head:
+ There is a small thread
+ Cone
- The angle of the screw compared to the disc: ≥35 degrees (inclined 7.5 degrees compared to the middle line)
- Size:
+ Diameter: 3.0-3.5mm
+ Length: 12-18mm Step 2mm
Genuine sterilized packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
set/box |
||
124 |
The cervical spine disc first |
5 |
Female |
-Material: Peek (ASTM F2026) and Titanium Alloy Ti-6al-4V ELI (ASTM F136).
- Fair design.
- The upper and lower surface is serrated (the teeth from 0.5mm - 0.8mm) help the disc firmly stick on the surface of the vertebrae.
- The angle of inclination between the upper and underside the disc is from 0 degrees to 8 degrees.
- In the middle of the large bone stuffed compartment design, it can accommodate a lot of transplant bones.
-The disc has 3 markers made of titanium that can be easily observed on X-ray or C-Arm film.
- Diameter/ height: 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14mm.
- Width: 15 mm
- Depth: 12 mm
- Tilt angle: 0 degrees to 8 degrees.
- Standard: ISO 13485: 2016
- Has sterilized, separate packaging in boxes, long term (5 years)
- Use corresponding to the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
125 |
The spinal disc spinal disc with screws |
5 |
Female |
-Material: Peek (ASTM F2026) and Titanium Alloy Ti-6al-4V ELI (ASTM F136).
- Semi -circular image is suitable for the neck disc structure. The disc body has 2 screw holes into the vertebrae body, the angle is suitable by two screw center lines from 20 degrees to 45 degrees, with a screw lock screw.
- The upper surface and the underside are sawtic (tooth height from 0.5mm - 0.8mm), helping the disc to stick to the bone surface.
- The angle of inclination between the upper and underside the disc is from 0 degrees to 8 degrees. The level is from 0 degrees to 10 degrees.
- Large bone stuffed cavity helps to store many graft bones.
-The disc has 3 markers made of titanium that can be easily observed on X-ray or C-Arm film.
- Dimensions:
+ Diameter/ height: 5, 6, 7, 8, 9, 10, 11, 12, 13mm.
+ Width: 17 mm;
+ Depth: 15 mm;
+ Thickness: rear sides 3.5mm; next to 3 mm; 3.5 mm front edge.
- Attach 2 specialized screws, there are 2 types of taro and self -drilling:
+ For Taro self -screws, the outer edge of the cylindrical screw body and the angle in the screw nose is 90 degrees.
+ For self -drilling type, the outer boundary of the conical screw body and the angle in the screw nose is 30 degrees.
- ISO 13485: 2016 standard
- Has sterilized, separate packaging in boxes, long term (5 years)
- Use corresponding to the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
126 |
Curved back cylinder disc spinal disc |
24 |
Female |
-Material: Peek (ASTM F2026) and Titanium Alloy Ti-6al-4V ELI (ASTM F136).
- Curved design (banana/ bean shape ...)
- The upper and lower surface has serrated (tooth height from 0.5mm - 0.8mm) to help the disc firmly stick to the bone surface.
- The angle of inclination between the upper and underside the disc is from 0 degrees to 8 degrees, the level is from 0 degrees to 10 degrees, helping the disc are compatible with the spine physiological structure when placed in the patient's body.
- The two discs are beveled with 30 degrees to make it easy to place the disc between the back vertebra.
- The disc can rotate at an angle from 10 degrees to 90 degrees when placed. This technique helps reduce shock on the body of life and make sure the disc is placed in the right position.
- Large bone stuffed cavity helps to store many graft bones.
- The disc body has transparent holes that help speed up bone healing.
-The disc has 3 markers made of titanium that can be easily observed on X-ray or C-Arm film.
- Length: 25mm to 30mm.
- Diameter/ height: 7, 8, 9, 10, 11, 12, 13mm.
- Curved radius from 28mm to 34mm.
- Standard: ISO 13485: 2016
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
127 |
The disc in lumbar spine surgery |
24 |
Female |
- Material: Peek
- At least 2 points marked by tantalum
- The distance from the front to the marker: ≥2mm
- The distance from the back wall to the marker: ≥5mm
- Sawing decay: ≥0.9mm
- Bone volume: in the range of 0.58cc - 1.04cc
- Size:
+ Length: ≥28mm
+ Width: ≥11mm
+ Height: in the range of 8-14mm
+ Raise: in 3 degrees - 5 degrees
- Genuine sterilization packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ pieces |
||
128 |
The disc in lumbar lumbar surgery |
24 |
Box |
Including: 2 disc
- Material: Peek
- There are 2 points marked by tantalum
- The distance from the front wall to the marker: ≥2.5mm
- The distance from the back wall to the marker point: ≥2.5mm
- Sawing decay: ≥0.9mm
- There is bone compartment inside
- Bone volume: in the range of 0.6cc - 1.1cc
- Size:
+ Width: ≥10.5mm
+ Length: ≥22mm
+ Height: in the range of 8-14mm
+ Raise: 0 degrees, 5 degrees
- Genuine sterilization packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/2 pieces |
||
129 |
Titanium cage artificial vertebra |
4 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 standards.
- The two ends of the artificial vertebra have a splint with 4 holes to screw into the upper - lower vertebra body.
- The cylindrical body has an empty bone cavity and adjusts the length depending on the size of the vertebrae that needs to be replaced.
- On the body, there are 2 to 3 lock screws to fix when adjusting the necessary length.
- Diameter: 14mm.
- Length: from 20mm to 42.5 mm.
- Angle from -10 degrees to 10 degrees. The amplitude increases the height of each size from 0 to 20mm.
- Attached to 4.0mm diameter screws, helping to fix the artificial vertebra into the spine.
- Standard: ISO 13485: 2016.
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
130 |
Artificial vertebra, titanium cage |
4 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 standards.
- Mesh -shaped cylindrical design helps increase the grip and restoration of the bone.
- The length may vary depending on the size of the vertebrae body need to be replaced.
- The empty center creates a space to contain the grafted bone easily.
-The external intervals have gaps, creating contact surface for bone to adhere to the surrounding bones.
- Diameter: 12 mm, 14mm
- Length: from 20mm to 50 mm.
- Quality standard: ISO 13485: 2016
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
131 |
Bleeding glue |
5 |
Set |
Hemostatic glue is a mixture of gelatin particles from cows and thrombin from the connected person, these two components play an important role, providing independent hemostasis effect, regardless of the body's hemostatic mechanism.
* Product origin: G7
* Meeting standards: ISO and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set |
||
132 |
Clamp of blood vessel aneurysms of all kinds, sizes |
200 |
Female |
- Clip clips of cerebral vascular aneurysms. Titanium material.
- Titanium mini clip type: blade length 5.0mm and 7.0mm, maximum openness 3.5mm; 4.0mm and 4.6mm, with force of 1.08N/110g.
- Titanium mini clamp with 3.5mm window hole: tongue length 3.0/6.9mm and 3.0/5.1mm, maximum openness 3.2mm, window hole diameter 3.5mm with force closed 110g.
- Titanium standard clamp: 6.4mm blade length; 7.0mm; 8.0mm; 8.3mm; 9.0mm; 11.0mm; and 12.0mm, maximum opening of 6.1mm; 6.5mm; 6.8mm; 7.0mm; 7.8mm; 8.8mm; 7.9mm and 10.2mm, with force of 1.77N/180g and 1.96N/200g.
- Titanium standard clamp with window hole 5.0mm: blade length 6/12.7mm; 9/15.7 and 5/6.7mm, maximum openness 5.5mm; 7.9mm and 9.1mm, with force of 1.47N/150g.
- Super short bulge bag type: tongue length 3.0/6.3mm and 3.0/6.7mm, maximum openness 5.5mm and 5.8mm, with force closed from 1.47N, window hole diameter 3.5 and 5.0mm.
- Fixed clamp type: tongue length 9.0mm and 13.0mm, with an angle of 90 and 60, maximum openness 5.5mm, with force of 1.47N/150g and 1.77N/180g.
Passive packaging.
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
133 |
Kim poked the cement pump into the vertebra body |
60 |
Female |
- Material: stainless steel
- Size: There are 2 types 11g and 13g, long ≥125mm
- Genuine sterilization packaging
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag |
||
134 |
Titan |
50 |
Female |
- Materials Titanium ASTM standard F -67 (CP1 - Commercially Pure 1)
- Dimensions: 50 mm long, 56 mm wide, mesh diameter compatible with screws 1.5/1.6mm. Screw hole sinking. Mesh thickness 0.6 mm.
- Deviation compared to the entrance of the GE Signa 3T MR system is smaller than 1 °. The system under MR Conditional conditions according to ASTM F2503-13 standards.
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 pc/ box |
||
135 |
Titanium skull mesh |
2 |
Female |
Materials Titanium Pure Pure Type 1, 3.
- 3D structure, size: 148mm long, 148mm wide, mesh diameter suitable for screws 1.5/1.6mm. Mesh thickness 0.6 mm. Screwdriver hole
- Deviation compared to the entrance of the GE Signa 3T MR system is smaller than 1 °. System under Mr Conditional conditions according to ASTM F2503-13 standards
- Use synchronously with Titanium screw screws (Taro) with a diameter of 1.5/ 1.6mm, 4mm long.
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 pc/ box |
||
136 |
Self -destructive biological brain graft |
24 |
Female |
The patch of the brain defects self -consuming the space and regenerating the skull cut after the skull surgery. Polycaprolacton, porous. Loss size 250-1600µm. Size 100x2x3.5mm. Self -digesting pieces after the bone is reproduced.
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 pc/box |
||
137 |
Self -adhesive epidural regeneration patch |
130 |
Pieces |
-Poly-Lactic Acid and Porcine Gelatin. Products decomposed into H2O and CO2 can be completely absorbed for 12 months.
- Inside the multi -micro structure form, no tissue, reducing surgical complications, high mechanical ability, self -adhesive, self -sufficient.
- Can be placed, stitched
- Size 7.5x7.5cm
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 piece/ box |
||
138 |
Self -adhesive epidural regeneration patch |
24 |
Pieces |
-Poly-Lactic Acid and Porcine Gelatin. Products decomposed into H2O and CO2 can be completely absorbed for 12 months.
- Inside the multi -micro structure form, no tissue, reducing surgical complications, high mechanical ability, self -adhesive, self -sufficient.
- Can be placed, stitched
- Size 8x12cm
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 piece/ box |
||
139 |
The neck splint first |
5 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 standards.
- Length: from 25 mm to 34 mm.
- Split thickness: from 1.7mm to 2.2 mm
- Width: from 16mm to 20mm.
- The brace body has holes to screw the neck spine first, on the holes with a lock design with a screwdriver lock mechanism.
- The cervical spine screws front catch with a splint at an angle ranging from 0 degrees to 20 degrees.
- The front spine brace is bent in the physiological curvature of the spine, and can be adjusted according to each patient.
- There are windows that make it easy to observe the correlation position between braces and disc.
- Quality standard: ISO 13485: 2016.
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
140 |
The cervical spine splint in front of 1 floor |
6 |
Female |
- Material: Titanium alloy
- Bent splint
- Cams lock mechanism
- Size:
+ The thickness of the splint is about 2.0-2.25mm
+ The length of about 19-43mm increased ≤1.5mm
* Meeting standards: ISO 13485 and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag/1 piece |
||
141 |
The spine brace in front of 2 floors |
4 |
Female |
- Material: Titanium alloy
- Bent splint
- Cams lock mechanism
- Size:
+ The thickness of the splint is about 2.0-2.25mm
+ The length of about 32-54mm increases ≤1.5mm
* Meeting standards: ISO 13485 and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag/1 piece |
||
142 |
Vertical splint |
24 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 Standard
- Design of a solid round bar, 2 ends: one round, one end of a hexagon.
- Rod connection bar is engraved with laser lines to help orient when bending.
- ROD connection bar is compatible with single -axis leg screws - multi -axis of all kinds.
- Diameter: 5.5mm
- Length from: 80mm to 95mm, increasing 5mm
- Quality standard: ISO 13485: 2016
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
143 |
The brace of the lumbar spine is 50-90mm long, genuine sterilized packaging |
10 |
Box |
Including: 2 splints
- Material: Titanium alloy
- The vertical brace is bent
- Compatible with multi -axis screws with the same manufacturer
- Size:
+ Diameter: 5.4mm
+ Length: 50-90mm
- Genuine sterilization packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/2 pieces |
||
144 |
The lumbar spine brace is used in screw -proof surgery |
12 |
Female |
- Material: Titanium alloy
- Bending vertical splint
- A pointed tip, a flat head and round hole
- Compatible with screws with long tails in about 110-120mm
- Size: 5.5mm diameter, 40-90mm long
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag |
||
145 |
The brace is attached to the cervical spinal disc |
12 |
Set |
Including: 1 disc and 1 splint
Disc:
- Material: Peek
- There are 2 points marked in titanium
- The distance from the front wall to the marker: ≥0.95mm
- The distance from the back to the marker: ≥1.3mm
- Sawing decay: ≤0.5mm
- Size:
+ Depth: In the range of 12, 14mm
+ Width: ≥15mm and ≤17mm
+ Height: in the range of 5-7mm
Brace:
- Can adjust and disassemble
- There are 2 holes to screw
- Size:
+ Thickness: ≤1mm
+ Length: in the range of 20-25mm
+ Width: ≤7.5mm
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
set/box |
||
146 |
Genuine sterilized lumbar spine brace |
2 |
Set |
Including: 2 hook + 1 splint
- Material: Titanium alloy
- Including:
+ Display horizontal brace hook
+ Screws locked hexagonal brace
+ The brace is 20-80mm long and 10mm.
- Compatible with multi -axis screws with the same manufacturer
- Genuine sterilization packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
set/box |
||
147 |
The brace is horizontal the lumbar spine |
4 |
Female |
- Material: Titanium alloy
- Long size: 35, 38, 42, 50mm
- Compatible with screws with 2 types of thread
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag |
||
148 |
Titanium brain splint |
144 |
Female |
Material: Titanium pure commercial type 1, 3. The brace is compatible with 1.6mm screw drill, 0.4mm sinking screw hole. The splint has a diameter of 14mm or 18mm, 0.67mm thick, including 6 opposite screw holes. Has the handle about 19mm long. Mr Conditional meets the ASTM F2503-13 standard.
- Use synchronously with Titanium screw screws with a diameter of 1.5/ 1.6mm in diameter, 4mm long.
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 pc/ box |
||
149 |
20 -hole straight splint |
144 |
Female |
- Material: Titanium CP (ASTM F-67) Type 1.3.
- The diameter of the splint is compatible with the 1.6mm screwdriver, the screwdriver is 0.4mm. The thickness of the splint is about 0.67mm.
- Straight brace consists of 20 screw holes, about 95mm long brace
- The distance between 2 screw holes is about 5mm
- Having a guideline, the distance from the splint to the handle is about 10.2mm.
- Deviation compared to the entrance of the GE Signa 3T MR system is smaller than 1 °.
- System under Mr Conditional conditions according to ASTM F2503-13 standards
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
1 pc/ box |
||
150 |
Lock snail |
120 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 standards.
- Diameter from 7mm to 11mm.
- Designing prison snails, compatible with company assistants.
- Leading lock in the new generation, the design of the reverse thread, self -locking when twisting enough to help prevent screw removal, anti -climbing, holding the ROD connection bar to create a solid transplant system.
- Quality standard: ISO 13485: 2016.
- Has sterilized, packed individually in boxes, long term (5 years).
- Use compatible with screws and braces vertical types, sizes of the same company.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
151 |
Screws (multi -axis) |
96 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 standards.
- Tulip flower screw head.
- Shooted screws and 2 grooves to help self -screws, easily catch into the bone.
- The screw body has 2 types of threads: 2/3 of the front threads are sharp thread, catching on the porous bone (vertebrae); One third of thread later is threaded, catching the bone shell (bow leg).
- Multi -axis screws change the angle between the body and the screw hat. The rotating angle changes from 0 degrees to 60 degrees.
- Screw diameter: from 4.0mm to 8.5mm, increasing 0.5 mm
- Screw body length: From 20mm to 60mm each increased 5 mm.
- Multi -color, easy to distinguish size.
- Quality standard: ISO 13485: 2016.
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
152 |
Screws (multi -axis) |
24 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 standards.
- Tulip flower screw head.
- Shooted screws and 2 grooves to help self -screws, easily catch into the bone.
- Screws have double threaded threads with different thread steps, gradually expanding from the screw hat to the screw tail. The sub -compressed thread mechanism helps increase the grip of the screw into the bone.
- The screw body has 2 types of threads: 2/3 of the front thread is sharp thread, catching on the porous bone (the vertebrae body), the two adjacent thread wings are 4mm; One third of thread later is threaded, catching into the bone shell (bow leg), the distance of two adjacent threads is 2mm.
- Multi -axis screws change the angle between the body and the screw hat. The rotating angle changes from 0 degrees to 60 degrees.
- Screw body diameter from 4.0mm to 8.5mm, increasing 0.5 mm
- The length of the screw body from 20mm to 60mm each increases 5mm.
- Multi -color, easy to distinguish size.
- Quality standard: ISO 13485: 2016.
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
153 |
Cervical spine screw |
48 |
Box |
- Material: Titanium alloy
- Compatible with the brace attached to the cervical spine
- Size:
+ Diameter: in the range of 4.0-4.5mm
+ Length: about 12-18mm steps increased 2mm
- Genuine sterilization packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ 2 pieces |
||
154 |
Cervical spine screw |
40 |
Female |
- Material: Titanium alloy
- Self -drilling screws
- The screw type has a fixed angle
- The color of the screw varies depending on the length
- Compatible with the front spine splint
- Size:
+ Diameter: in the range of 4.2-4.6mm
+ About 12-26mm long steps increased 2mm
* Meeting standards: ISO 13485 and FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag/1 piece |
||
155 |
Cervical spine screws first |
10 |
Female |
-Material: Titanium Alloy Ti-6al-4V ELI according to ASTM F136 standards.
- Comes with the front spine splint to help fix the cervical spine splint into the vertebrae.
- Thin screw hat helps to stick to the body of the brace.
- The screw body has pointed thread, the screw nose has 2 grooves to help the screws self.
- Screw with a splint at an angle from 0 degrees to 20 degrees.
- Diameter 3.5mm; 4.0mm; 4.5mm.
- The length from 13mm to 18mm each increased by 1mm.
- Quality standard: ISO 13485: 2016
- Has sterilized, packed individually in boxes, long term (5 years).
- Used compatible with the company aid.
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Pieces/package |
||
156 |
Multi -axis screw screws |
40 |
Female |
- Material: Titanium alloy
- Rotation angle: in about 40 degrees -50 degrees
- There is a double locking system
- Ren screw screws
- Size:
+ Diameter: in the range of 3.5-4.5mm
+ About 8-52mm long
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag |
||
157 |
Lumbar multi -shaft screw |
96 |
Female |
- Material: Titanium alloy
- Screw body:
+ There are at least 2 lace types
+ Cylindrical screw thread
- Rotation angle in the range of 40-50 degrees
- Size:
+ Diameter: 4.5-7.5mm Step 1mm
+ 20-60mm long step by 5mm
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag |
||
158 |
The super -long multi -tail screw is the minimum intervention through the skin |
24 |
Female |
- Material: Titanium alloy
- Use in minimum skin intervention (MIS)
- There is a double locking system
- Size:
+ The tail is about 110-120mm long
+ Diameter 5.0-7.5mm steps increased 0.5mm, length 25-100mm increasing 5mm
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag/1 piece |
||
159 |
Multi -axis screws with lumbar spine and screws in sterilization |
50 |
Set |
Including: 2 multi -axis screws + 2 inner lock screws:
Screw:
- Material: Titanium alloy
- Screw body:
+ There are ≥9 holes
+ Empty screw body, with a diameter of 1.8mm
+ The tip of the screw nose has a diameter of 1.35mm
+ Diameter: in about 5-7mm
+ Length: in the range of 35-60mm
Cannula pump cement: with a volume of 2cc, each line 0.5cc
Lock screw in:
- Material: Titanium alloy
- Hexagonal
Genuine sterilized packaging
* Product origin: Europe
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
set/box |
||
160 |
Lock screw in cervical spine |
40 |
Female |
- Material: Titanium alloy
- Compatible with multi -axis screws with double locking system
- Size: The diameter is about 3.0-4.0mm
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag/1 piece |
||
161 |
Lock screw in the lumbar spine |
96 |
Female |
- Material: Titanium alloy
- Size:
+ Height: ≥5.3mm
+ External diameter: ≥10mm
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag |
||
162 |
Lock screw in the lumbar spine is compatible with the minimum multi -tailed multi -axis screw. |
24 |
Female |
- Material: Titanium alloy
- Star picture
- Compatible with screws with long tails in about 110-120mm
- Size:
+ Outside diameter ≥10.6mm, height ≥4.7mm
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Bag/1 piece |
||
163 |
Titanium screw screws self -drilling |
720 |
Female |
- Material: Titanium pure trade type 1, 3 or ASTM F-136.
- Diameter: 1.6 mm, long: 4mm. Self -drilling screws, cross -shaped screw heads, 2.7mm screw head diameter, screw height ≤0.94mm, sinking screw angle.
- Compatible with 1.5mm screwdriver and mesh diameter. Single thread with thread step ≤0.97mm. Mr Conditional meets the ASTM F2503-13 standard
* Meeting standards: FDA (US Food and Drug Administration)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
6 pieces/ box |
||
164 |
Cement shaped the vertebrae |
30 |
Jar |
- Ingredient:
+ PMMA polymer (powder): ≥27.2g
+ In which there are zirconium dioxide ≥45% and hydroxyapatite 5%
+ MMA monomers (solution): 8-10g
- contrast substance: ≥50%
- Low viscosity
- Genuine sterilization packaging
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/ vial |
||
165 |
Full knee joint |
50 |
Set |
The knee joint is completely asymmetric, the main material of the convex and the tibial plateau made of cobalt-chrome molybdenum alloy (cocrmo) polish the surface, the outer is covered with chromium nitride alloy layers, chromium carbon nitride outermost coating the zirconium nitride to minimize cases J -shaped axis, the front -section design reduces bone loss and increases the exposure area of the convex to the surface of the bone, the knee folding up to 160 degrees.
- Convex bridge has sizes: F1, F2, F3, F4, F5, F6, F7, F8.
-The tibial buffer layer is made of high -quality materials Beta Polyethylent (UHMWPE -ISO 5834-2) size 10,12,14,16,18,20 mm, designed after 3 degrees reducing the risk of dislocations.
- Fish fins designed with sizes: T0, T1, T2, T3, T4, T5.
Mechanism of combining tibial plateau and convex bridge:
+ T0: F1, F2, F3, feasible F4
+ T1: F1, F2, F3, F4, feasible F5
+ T2: F2, F3, F4, F5, feasible F1 and F6
+ T3: F3, F4, F5, F6, feasible F2 and F7
+ T4: F4, F5, F6, F7, feasible F3
+ T5: F5, F6, F7, feasible F4
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
166 |
Full knee joint |
30 |
Set |
Surgical type: Saving bone for patients. Conservation of diagonal ligaments/ stabilization of the following way includes the following details:
1. Femoral Condyle with 9 sizes: Size 1, 2, 3, 4, 5, 6, 7, 8.9; Left/Right convex size
+ Corresponding to the convex size in the outside of ML (mm): 59, 61, 64, 66, 68, 71, 73, 75.79.
+ Corresponding size convex ahead of AP (mm): 53, 56, 58, 61, 63, 66, 68,70, 72.
+ Immortal protruding behind asymmetric bridge. Polished with cobalt chromium cocrmo alloy material
2. Tibial tray (Tibial Tray) with 9 sizes: Size 1, 2, 3, 4, 5, 6, 7, 8, 9. Design the sliding system of the baseball lock with the cushion.
+ Corresponding to the size of the tibial platform inside ml (mm): 59, 63, 67, 71, 75, 79, 83, 87, 91.
+ Corresponding to the size of the tibial platform before AP (mm): 38, 41, 43, 46, 48, 51, 53, 56, 58.
+ Corresponding height Height of Keel (mm): 33, 33.36, 36, 36, 36, 39, 39, 39.
+ Polished with Cobalt Chromium CocRMO alloy material, the back bank has a tibial platform with a back ligament protection.
3. Articular Insert) with 9 sizes: Size 1, 2, 3, 4, 5, 6, 7, 8, 9. Each size has the following thickness: 6, 8, 10, 12, 14, 16 mm; Polyethylene material Ve Highly Cross-Linked Uhmwpe, with vitamin E that helps reduce the abrasion of the cushion.
+ The cushion sise has the minimum thickness of 6mm to help preserve the bone maximum.
4. Patella (Patella) with diameter: 25, 28, 31, 34, 37mm; The thickness of 2 sizes 7.5mm and 10mm, regenerating the oval surface, regenerating the bridge surface, two protruding sides. Polyethylene Ve Highly Cross-Linked Uhmwpe material, vitamin E.
Mechanism of combining tibial plateau and convex bridge:
+ Size 1 tibial platforms are feasible to convex bridge size 1-2
+ Size 2 tibial platforms are feasible to convex bridge size 1,2,3,4
+ Size 3 tibial plateau is feasible to convex bridge size 1,2,3,4,5
+ Size 4 tibial plateau is feasible to convex bridge size 2,3,4,5,6
+ Size 5 tibial plateau is feasible to convex bridge size 3,4,5,6,7
+ Size 6 tibial plateau is feasible to convex bridge size 4,5,6,7,8
+ Size 7 tibial plateau is feasible to convex bridge size 5,6,7,8,9
+ Size 8 tibial plateau is feasible to convex bridge size 6,7,8,9
+ Size 9 tibial plateau is feasible
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
167 |
Full knee joint |
30 |
Set |
1. Convex thigh bridge:
Chrome cobalt material, 9mm thick edge, 15 -degree tilted front, maximum knee folding ≥145 degrees, patella grooves are designed to suit the natural knee joint. Bone cutting design at the convex bridge groove.
There are 9 sizes each left and right.
+ Corresponding to the convex size in the outside of ML (mm): 59, 61, 64, 66, 68, 71, 73, 75.79.
+ Corresponding size convex ahead of AP (mm): 53, 56, 58, 61, 63, 66, 68,70, 72.
+ Immortal protruding behind asymmetric bridge. Polished with cobalt chromium cocrmo alloy material
2. Lining: PE has vitamin E supplementation (highly cross-linked uhmwpe)
Polyethylene material super high molecules cross -linked with vitamin E supplements. Has a locked edge with a lock mechanism along with sliding grooves. There are 9 sizes (1-1) corresponding to the thickness of 6mm, 8mm, 10mm, 12mm, 14mm, 16mm.
+ The cushion sise has the minimum thickness of 6mm to help preserve the bone maximum.
3. Grate tibial plateau:
Tibial tray (Tibial Tray) with 9 sizes: Size 1, 2, 3, 4, 5, 6, 7, 8, 9. Design a sliding system to lock the baseball baseball with a cushion.
+ Corresponding to the size of the tibial platform inside ml (mm): 59, 63, 67, 71, 75, 79, 83, 87, 91.
+ Corresponding to the size of the tibial platform before AP (mm): 38, 41, 43, 46, 48, 51, 53, 56, 58.
+ Corresponding height Height of Keel (mm): 33, 33.36, 36, 36, 36, 39, 39, 39.
4. Park:
Park (Patella) with diameter: 25, 28, 31, 34, 37mm; The thickness of 2 sizes 7.5mm and 10mm, regenerating the oval surface, regenerating the bridge surface, two protruding sides. Polyethylene Ve Highly Cross-Linked Uhmwpe material, vitamin E.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
168 |
Full knee joint |
20 |
Set |
1. Convex thigh bridge:
Chrome cobalt material, 9mm thick edge, 15 -degree tilted front, maximum knee folding ≥145 degrees, patella grooves are designed to suit the natural knee joint. Bone cutting design at the convex bridge groove.
There are 9 sizes each left and right.
+ Corresponding to the convex size in the outside of ML (mm): 59, 61, 64, 66, 68, 71, 73, 75.79.
+ Corresponding size convex ahead of AP (mm): 53, 56, 58, 61, 63, 66, 68,70, 72.
+ Immortal protruding behind asymmetric bridge. Polished with cobalt chromium cocrmo alloy material
2. Lining:
Super -high polyethylene material cross -binding molecules. There is a locking edge by locking mechanism along with sliding grooves. There are 9 sizes (1-1) corresponding to the thickness of 6mm, 8mm, 10mm, 12mm, 14mm, 16mm.
+ The cushion sise has the minimum thickness of 6mm to help preserve the bone maximum.
3. Grate tibial plateau:
Tibial tray (Tibial Tray) with 9 sizes: Size 1, 2, 3, 4, 5, 6, 7, 8, 9. Design a sliding system to lock the tibial platform with the cushion.
+ Corresponding to the size of the tibial platform inside ml (mm): 59, 63, 67, 71, 75, 79, 83, 87, 91.
+ Corresponding to the size of the tibial platform before AP (mm): 38, 41, 43, 46, 48, 51, 53, 56, 58.
+ Corresponding height Height of Keel (mm): 33, 33.36, 36, 36, 36, 39, 39, 39.
4. Park:
Park (Patella) with diameter: 25, 28, 31, 34, 37mm; The thickness of 2 sizes 7.5mm and 10mm, regenerating the oval surface, regenerating the bridge surface, two protruding sides. Polyethylene highly cross-linked uhmwpe material.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
169 |
Full knee joint fixed to preserve the back ligament |
30 |
Set |
1. Femoral component:
- Material: Cobalt chromium molybdenum - ISO5832/4.
- Surface: Coverbn, roughness meets ISO 7207-2.
- Bone contact surface: Small holes to evenly distribute cement
- Size: 10 sizes from 4-13, distinguishing left and right.
- Inner size: L (57.5; 60; 62.5; 65; 67,5; 70; 72.5; 75; 77.5; 80)
2. Tibia Top composition (Tibia Top):
- Material: Titanium aluminum vanadium - ISO5832/3.
-Size: 10 sizes of tibial plateau combined with tibial cushion with color code (XS-A/Pink, B-C/Green, D-E/Red, F-G/Blue, H-I/Orange).
- Far away can attach an extension of the stem.
3. Liner (liner):
- CR CR Conservation of the back ligament
- Material: Uhmw Polyethylene does not have Calcium Stearate - ISO5834/1/2
- Thickness: 9 thickness (9mm, 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, 17mm, 20mm).
4. Patella (Patella):
- Material: Uhmw polyethylene without calcium stearate - ISO5834/1/2.
- Size: 6 sizes (28mm-38mm, each increase 2mm)
- The thickness of the tea cake 8mm, 8.5mm, 9mm, 9.5mm, 10mm, with 2 mm thick edges
The symmetrical patch distance 14.2 on the palace 120⁰
5. Cement
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
5cs/set |
||
170 |
All -knee knee joints have cement |
20 |
Set |
- The total knee joint with cement has a moving center at the back is single axis, allowing complete stretching up to 130 degrees.
- The contact surface of the thigh convex and lining ≥800mm2. The tibial pads are portable.
1. Convex thigh bridge:
+ Material: Chromium cobalt molybdenum
+ The left has 5 sizes and the right has 5 sizes
2. Grate tibial plateau:
+ Material: Chromium cobalt molybdenum
+ There are 5 sizes
3.
+ Material: Polyethylene
+ Motion amplitude ≥ 3 ° and ≤ 6 °
+ Height 9, 11, 13, 15mm; Each height has 5 sizes
4. Cake bone:
+ Material: High molecular polyethylene
+ Diameter: 31, 34, 37mm
5. Cement with the manufacturer
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/5 pieces |
||
171 |
Watch output knee joints stable when there is no rear ligament |
20 |
Set |
1. Femoral component:
- Material: Cobalt chromium molybdenum - ISO5832/4.
- Surface: Coverbn, roughness meets ISO 7207-2.
- Bone contact surface: Small holes to evenly distribute cement
- Size: 10 sizes from 4-13, distinguishing left and right.
2. Bioloy Tibia:
- Material: Titanium aluminum vanadium - ISO5832/3.
- Size: 10 sizes XS, A, B, C, D, E, F, G, H, I.
- Far away can attach an extension of the stem.
3. Mobile Insert):
- UC type brings high stability
- Material: Uhmw polyethylene without calcium stearate - ISO5834/1/2.
- Thickness: 10 thickness (9mm, 10mm, 11mm, 12mm, 13mm, 14mm, 15mm, 17mm, 18mm, 20mm)
4. Patella (Patella):
- Material: Uhmw polyethylene without calcium stearate - ISO5834/1/2.
- The thickness of the tea cake 8mm, 8.5mm, 9mm, 9.5mm, 10mm, with 2 mm thick edges
The symmetrical patch distance 14.2 on the palace 120⁰
- Size: 6 sizes (28mm-38mm, each increase 2mm)
5. Cement
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
5cs/set |
||
172 |
The hip joint sells non -cement |
10 |
Set |
* STEM: There are Taper 8/10 & 12/14, Rotation amplitude 135 °, 55 ° bone cutting line, wings & anti -rotary grooves. The surface of the main bearing area is close to the coating with Plasmamore technology µ-cap (calcium phosphate cap) accelerate the formation of the bone surface in contact with the hilt.
* The isotan F-Titanium Forged Alloy (Ti6al4V / ISO 5832-3). There are 11 standard sizes with the following size and length: 8: 112mm, 9: 116mm, 10: 120mm, 11: 124mm, 12: 127mm, 13: 131mm, 14: 135mm, 15: 138mm, 16: 142mm, 17: 146mm, 18: 150mm.
- Length of hilt (from the neck to the end of the hilt): 145-190mm
- The surface of the main bearing area at the top near the Titanium coating Plasmapore is 0.35mm thick
* Head: ISODUR F COBALT-CHROMIUM forged alloy material (cocrmo / ISO 5832-12). There is Taper 12/14. Rotated 135º, 22.2mm attached head for bipolar with a diameter of 39mm - 51mm, 28mm cap for bipolar for 43mm - 55mm diameter. There are many sizes S, M, L, XL, XXL.
* Cup Bipolar: Ultra High Molecular Weight Polyethylene UHMWPE material inside, (ISO 5834-2), outside the Stainless Steel ISO 5832-1 material has 39mm-55mm size, with anti-order locking loops.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/ 3 pieces |
||
173 |
The hip joint sells non -cement |
10 |
Set |
Combined with previous operating tools
Including 4 dishes: Varioloc Hop-free hip joint, small slender hilt suitable for small marrow, made of titanium alloy material (Ti-6al-4V) covered with whole body, neck corner of 131 degrees, small dual-headed tip from 39-> 59 mm.
1. Do not use Varioloc Ha Pressfit Titanium Alloy Ti-6al-4V. Horizontal groove against subsidence and vertical grooves against rotation with bone cutting line 41 degrees. The neck corner of the body is 131 °, the neck is 12/14mm, with 10 sizes 7.5: 114mm (offset c: 31mm; d: 36mm), 9: 117mm (offset c: 31mm; d: 37mm), 10: 119mm (offset c: 34mm; d: 40mm), 11: 121mm (Offset C: 34mm; D: 41mm), 12.5: 124mm (Offset (offset (offset (offset (offset (offset (offset (offset. C: 34mm; D: 41mm), 13.5: 126mm (Offset C: 37mm; D: 45mm), 15: 129mm (Offset C: 37mm; D: 45mm), 16: 132mm (Offset C: 37mm; D: 46mm), 17.5: 134mm (Offset C: 37mm; D: 47mm), 20: 139mm (Offset C: 37mm; D: 38mm).
2. The femur: cocrmo material, diameter 22 (-3mm, 0mm), 28mm (-3.5mm, 0mm, +3.5mm, +7mm, +10.5mm). Taper 12/14
3. Sell Vario part: Outside material with cocrmo alloy, external diameter from 39-59mm, step by 1mm.
4. The inner lining of polyethylene can be separated and the cap, including sizes 39-41mm, 42-44mm, 45-47mm, 48-50mm, 51-53mm, 54-56mm, 57-59mm.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
174 |
The hip joint sells non -cement |
5 |
Set |
1. The femoral hilt: the type of self -locking
- Material: Titanium aluminum vanadium alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm.
- The neck corner 135 °. Con 12/14 - 5 ° 40 '.
- The neck of the ellipse and the mirror is polished
- There are ≥ 9 sizes (step 1), length from 87-170mm
2. The thigh bone (core):
- Material: stainless steel
-Diameter 22.2mm (-2, 0,+3), 28mm diameter (-3.5, 0,+3.5)
3. Selling mortar parts:
- Material: Stainless steel outer surface, inside with polyethylene
- The outer surface is highly polished with roughness <0.5μm
- The mortar has a mechanism to lock the anti -dislocated joint
- Size: 38-60 (step 2)
* Gamma ray sterilization
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/3 pieces |
||
175 |
The hip joint sells non -cement |
20 |
Set |
Combined with previous operating tools
1. Do not use Varioloc TPS Pressfit cement Titanium Alloy Ti-6al-4V covered with titanium plasma. Vertical grooves help stimulate the foam bone to stick to the head near the hilt, with 41 -degree bone cutting line. The neck corner of the body is 131 °, the neck is 12/14mm, with 12 sizes: 5: 109mm (offset c: 31mm; d: 35mm), 6: 111mm (offset c: 31mm; d: 35mm), 7.5: 114mm (offset c: 31mm; d: 36mm), 9: 117mm (offset c: 31mm; d: 37mm) C: 34mm; D: 40mm), 11: 121mm (Offset C: 34mm; D: 41mm), 12.5: 124mm (Offset C: 34mm; D: 41mm), 13.5: 126mm (Offset C: 37mm; D: 45mm), 15: 129mm (Offset C: 37mm; D: 45mm), 162mm (offset C: 37mm; D: 46mm), 46mm) 17.5: 134mm (Offset C: 37mm; D: 47mm), 20: 139mm (Offset C: 37mm; D: 48mm).
2. The femur: cocrmo material, diameter 22 (-3mm, 0mm), 28mm (-3.5mm, 0mm, +3.5mm, +7mm, +10.5mm). Taper 12/14
3. Sell Vario part: Outside material with cocrmo alloy, external diameter from 39-59mm, step by 1mm.
4. The inner lining with polyethylene uhmwpe can be separated and the cap, including the size 39-41mm, 42-44mm, 45-47mm, 48-50mm, 51-53mm, 54-56mm, 57-59mm
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
176 |
Cocr non -cement parts cover with 2 layers of titanium + HA |
20 |
Set |
1. Stem (STEM):
- Material: Titanium Aluminum NiiBium (Ti6al7NB) - ISO5832/11.
- Capital coat: 2 layer 300µm Titanium pure foam + 50µm hydroxyapatite by plasma spray technology.
- Structure: There are many vertical and horizontal grooves around the body of the stem
- Hepers size: There are 12 sizes from 1/130.3mm; 2/140.3mm; 3/145.4mm; 4/150.4mm; 5/155.5mm; 6/160.5mm; 7/165.5mm; 8/170.4mm; 9/175.4mm; 10/179.9mm; 11/185.4mm; 12/190.4mm.
- Angle neck: 12/14, 5º43'30 ''
- Offset: There are 2 types of offset standard CCD: 135º (38.6mm; 39.3mm; 40mm; 40.8mm; 41.5mm; 42.2mm; 42.9mm; 43.6mm; 44.1mm; 45.6mm); Lateralized CCD: 127º (44.9mm; 45.5mm; 46.3mm; 47.0mm; 47.7mm; 48.4mm; 49.1mm; 49.8mm; 50.3mm; 51.8mm)
- The method of disinfecting radiation with 25 kgy, or VH2O2 method
2. Femoral head:
- Material: Cobalt Chromium Molibdenum - ISO5832/12.
- Diameter: 28mm (-3.5; +0; +3,5; +7)
3. Bipolar head (Bipolar head):
- Material: High nitrochemical stainless steel alloy PM734 - ISO5832/9
- Size: There are 22 sizes from 39-60mm with every step of 1mm increasing, using Head diameter 28mm.
4. Bipolar head liner (liner)
- Material: Made from high molecular polyethylene, no calcium stearate - ISO5834/1/2, with a femoral bone lock ring
-The bipolar and head liner is combined with color code (39-42/green; 43-45/yellow; 46-52/blue; 53-60/red))
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
4cd/set |
||
177 |
The hip joint sells non -cement, long grip |
20 |
Set |
1.
- Material: Titanium aluminum vanadium alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm.
- The corner of the neck is 130 degrees. Con 12/14 - 5 ° 40 '
-Locking screw with 5.5mm diameter, 28-55mm long, 5.5mm diameter adjustment screws, 30-35mm long
-Size: 12-16 (step 2), length 200-300mm
2. The thigh bone (core):
- Material: stainless steel
-Diameter 22.2mm (-2, 0, +3), diameter 28mm (-3.5, 0, +3.5)
3. Selling mortar parts:
- Material: Stainless steel outer surface, inside with polyethylene
- The outer surface is highly polished with roughness <0.5μm
- The mortar has a mechanism to lock the anti -dislocated joint
- Size: 38-60 (step 2)
* Gamma ray sterilization
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/3 pieces |
||
178 |
Full hip joints Ceramic on pe, Pure Titanium porous covered with plasma spray technology |
20 |
Set |
1. Stem Sl X-Pore):
- Titanium aluminum vanadium (Ti6al4V) -ISO5832/3. Cover: 500µm Titanium pure porous by plasma spray technology. The surface structure has many grooves running along the stem.
- Size: There are 10 sizes 6.25/137mm; 7.5/137mm; 8.75/139.5mm; 10/142mm; 11.25/146.5mm; 12.5/147mm; 13.75/151.5mm; 15/152mm; 17.5/162.5mm; 20/162.5mm
- An corner of the hilt: 135º, neck 12/14 (angle above 5º42'30 '').
- Offset: 2 types of standard (34.8mm; 36.1mm; 37.0mm; 37.4mm; 38.2mm; 38.7mm; 41.4mm); Lateralized (41.1mm; 42.4mm; 43.5mm; 43.7mm; 44.8mm; 45.7.7mm)
- The method of disinfecting radiation with 25 kgy, or VH2O2 method
2. Ceramic ball head:
- Material: Alluminum, zicronia and some other oxydes (Al2O3+Zro2), low abrasion, high corrosion resistance, biological compatibility materials.
-Diameter: 28mm (-3.5; +0; +3.5), 32mm (-4; +0; +4; +8), 36mm (-4; +0; +4; +8), 40mm (-4; +0; +4; +8)
3. The mortar (shell):
- Material: Titanium aluminum vanadium (Ti6al4V) - ISO5832/3.
Cover: 500µm Titanium pure with Plasma spray technology.
- Size: There are 15 sizes from 42–70mm with each step increasing 2mm.
- Suitable for all types of cushioning.
- Structure: There is a locking system that holds the cushion tightly, the screw button is removable, the outer rim has the edge to optimize the press-fit closing
4. Liner (liner):
-Material: High molecular polyethylene (Ultra-High-Molecular-Weight Polyethylene (UHMWPE) without calcium stearate-ISO5834/1/2, with anti-disordered edges: 0º; 10º; 20º.
- Size ∅: 22mm; 28mm; 32mm; 36mm, 40mm.
5. Screw of a mortar (Screw): Titanium aluminum vanadium (Ti6al4V), 6.5mm diameter, length: 20-50mm (each step increased by 5mm), 50-60mm (each step increased 10mm).
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
5cs/set |
||
179 |
Full hip joints double motion |
30 |
Set |
Combined with previous operating tools
The whole hip joints are double motion, not using cement, small slender hilt suitable for small marrow, made of titanium alloy alloy (Ti-6al-4V) covered with HA, the neck corner of the body of 131 degrees. Variocup Pressfit mortar has screwed.
1. Variocup Pressfit: Compressed with many compressed teeth, Titanium Ti-6al-4V alloy material with a bearing axle lock mechanism, with 3 screws, including diameter of 42mm-68mm, 2mm increase.
2.
3.
4. The femur: cocrmo material, diameter 22 (-3mm, 0mm), 28mm (-3.5mm, 0mm, +3.5mm, +7mm, +10.5mm). Taper 12/14
5. Do not use Pressfit cement: Titanium alloy ti-6al-4v cover. Vertical groove anti -rotation with bone cutting line 41 degrees. The neck corner of the body is 131 °, the neck is 12/14mm, with 10 sizes: 7.5: 114mm, 9: 117mm, 10: 119mm, 11: 121mm, 12.5: 124mm, 13.5: 126mm, 15: 129mm, 16: 132mm, 17.5: 134mm, 20: 139mm.
6. Screws capanium Taro mortar drive with a diameter of 6.5mm from 15-70mm length.
7. Screw button blocking the bottom of the mortar (ScreW Plug)
8. Dome Hole Plug screwdriver (Dome Hole Plug)
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/8 pieces |
||
180 |
Full hip joint |
20 |
Set |
1. The femoral hilt: the type of self -locking
- Material: Titanium aluminum vanadium alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm
- The neck corner 135 °. Con 12/14 - 5 ° 40 '
- The neck of the ellipse and the polished mirror, the neck has a border around
- There is ≥8 size (step 1), length from 130-170mm
- Gamma rays
2. The thigh bone (core):
- Material: Alumina Ceramic
- Diameter 28mm (-3.5, 0, +3.5)
- Gamma rays
3. The nest: The mortar does not screw
-Material: Cobalt-Chromium-Molybdenum alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm
- The outside: around the edge is ≥6 nails, on the top is ≥4 nails
- The inner side: is polished high with roughness <0.05μm
- There is an orderly rim of 5mm with ≥2 marking points
- Size: 48-60 (Step 2)
- Gamma rays
4.
- Material: Polyethylene
- Double movement cushion layer
- Size: 48-60 (Step 2)
- Ethylene oxide sterilization
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
181 |
Full hip joint without cement |
30 |
Set |
STEM: There are Taper 8/10 & 12/14, Rotation amplitude 135 °, Bone cutting line 55 °, Wing & specialized anti -rotating groove. The surface of the main bearing area is close to the coating with Plasmamore technology µ-cap (calcium phosphate cap) accelerate the formation of the bone surface in contact with the hilt.
* The isotan F-Titanium Forged Alloy (Ti6al4V / ISO 5832-3). There are 11 standard sizes with the following size and length: 8: 112mm, 9: 116mm, 10: 120mm, 11: 124mm, 12: 127mm, 13: 131mm, 14: 135mm, 15: 138mm, 16: 142mm, 17: 146mm, 18: 150mm.
- Length of hilt (from the neck to the end of the hilt) 145-190mm.
- The surface of the main bearing area at the top is close to the 0.35mm thick titanium coating.
* Liner: Material with Ultra High Molecular Weight Polyethylene (ISO 5834-2) Combining Vitamine E
- The thickness of the lining in the main bearing area, at least 5.5 mm thick.
* Head: with diameter 22.2mm, 28mm, 32mm, 36mm, 40mm. Isodur® f cobalt-chromium forged alloy material (cocrmo / ISO 5832-12)
* Fear: Plasmafit Covered Cat Exclusive Technology Plasmapore® Pure Titanium (Ti / ISO 5832-2), Plasmapore Cap helps to heal bones from 8-12 weeks, with sizes from 40mm-70mm, with 3 screw holes at 11h, 12h, 13h. Titanium Forged Alloy (Ti6al4V / ISO 5832-3
* Screw: There are sizes 16mm, 20mm, 24mm, 28mm, 32mm, 36mm, 40mm, 44mm isotan® f material isotanium forged alloy (Ti6al4V / ISO 5832-3), multi-directional rotation angle +/- 9 °.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/ 5 pieces |
||
182 |
Full hip joint without cement |
40 |
Set |
* STEM: There are Taper 8/10 & 12/14, Rotation amplitude 135 °, 55 ° bone cutting line, wings & anti -rotary grooves. The surface of the main bearing area is close to the coating with Plasmamore technology µ-cap (calcium phosphate cap) accelerate the formation of the bone surface in contact with the hilt.
* The isotan F-Titanium Forged Alloy (Ti6al4V / ISO 5832-3). There are 11 standard sizes with the following size and length: 8: 112mm, 9: 116mm, 10: 120mm, 11: 124mm, 12: 127mm, 13: 131mm, 14: 135mm, 15: 138mm, 16: 142mm, 17: 146mm, 18: 150mm.
- Length of hilt (from the neck to the end of the hilt): 145-190mm.
- The surface of the main bearing area at the top is close to the 0.35mm thick titanium coating.
* Considers: PLASMAPORE TECHNOLOGY TECHNOLOGY 40% Cap helps to quickly heal from 8-12 weeks, with sizes from 44mm - 62mm suitable for braided braids with small mortar, with 3 screw holes at 11 hours, 12h, 13h. Titanium Forged Alloy (Ti6al4V / ISO 5832-3).
* Liner: There is an anti -disordered shore. Material with Ultra High Molecular Weight Polyethylene (ISO 5834-2), combined with vitamin E.
- The thickness of the lining in the main bearing area, at least 5.5 mm thick.
* Head: Material with Biolox® Delta Alumina Matrix Composite Ceramic generation latest. There are sizes 28mm, 32mm, 36mm, 40mm.
* Screw: There are sizes 16mm, 20mm, 24mm, 28mm, 32mm, 36mm, 40mm, 44mm Titanium alloy material (Isotan F).
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/ 5 pieces |
||
183 |
Full hip joint without cement |
10 |
Set |
* STEM: There are Taper 8/10 & 12/14, 55 ° bone cutting line, with specialized rotary wings & grooves. The surface of the main bearing area is close to coating with Plasmamore technology µ-cap (calcium phosphate cap) that accelerates the formation of bone surface in contact with the hilt,
* The isotan F-Titanium Forged Alloy (Ti6al4V / ISO 5832-3). There are 11 standard sizes with the following size and length: 8: 112mm, 9: 116mm, 10: 120mm, 11: 124mm, 12: 127mm, 13: 131mm, 14: 135mm, 15: 138mm, 16: 142mm, 17: 146mm, 18: 150mm.
- Length of hilt (from the neck to the end of the hilt): 145-190mm.
* Considers: PLASMAPore Cap exclusive technology helps to quickly heal from 8-12 weeks, with sizes from 40mm - 70mm, with 3 screw holes at 11 hours, 12h, 13h. Titanium Forged Alloy (Ti6al4V / ISO 5832-3).
* Liner: Biolox® Delta Aluminum Oxide Matrix Ceramic Ceramic. Liner 40mm-46mm uses a 28mm diameter head, Liner 48mm-50mm uses a 32mm diameter, Liner 52mm-54mm in diameter 36mm-75mm -70mm diameter used for HEAD 40mm
* Head: Material with Biolox® Delta Aluminum Oxide Matrix Ceramic. There are sizes 28mm, 32mm, 36mm, 40mm.
* Screws: There are sizes 16mm, 20mm, 24mm, 28mm, 32mm, 36mm, 40mm, 44mm isotan® f material isotanium forged alloy (ti6al4v / ISO 5832-3), multi-directional rotation angle +/- 9 °
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/ 5 pieces |
||
184 |
Full hip joint without cement |
10 |
Set |
Combined with previous operating tools
1. Variocup Pressfit: Compressed with many compressed teeth, Titanium Ti-6al-4V alloy material with a bearing axle lock mechanism, with 3 screws, including the diameter of 42mm-68mm, 2mm increase.
2. Ceramic lining: Ceramic material (Alumina - Zirconia ISO6474-2), sized 28mm, 32mm, 36mm, 40 mm. Compatible with the mortar from 44mm to 64mm
3. The femur: Ceramic material (Alumina -Zirconia ISO 6474-2), 28mm (-3.5mm, 0mm, +3.5mm), 32mm (-4mm, 0mm, +4mm, +7mm), 36mm (-4mm, 0mm, +4mm, +8mm), 40mm (-4mm, 0mm, 0mm, +4mm, +8mm). Taper 12/14
4. Do not use the Varioloc Ha Pressfit Titanium Alloy Ti-6al-4V. Horizontal groove against subsidence and vertical grooves against rotation with bone cutting line 41 degrees. The neck corner of the body is 131 °, the neck is 12/14mm, there are 10 sizes: 7.5: 114mm (offset c: 31mm; d: 36mm), 9: 117mm (offset c: 31mm; d: 37mm), 10: 119mm (offset c: 34mm; d: 40mm), 11: 121mm (offset c: 34mm; d: 41mm) C: 34mm; D: 41mm), 13.5: 126mm (Offset C: 37mm; D: 45mm), 15: 129mm (Offset C: 37mm; D: 45mm), 16: 132mm (Offset C: 37mm; D: 46mm), 17.5: 134mm (Offset C: 37mm; D: 47mm), 20: 139mm (Offset C: 37mm; D: 38mm).
5. Screws Titanium Taro Considers have a diameter of 6.5mm from 15-70mm length.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/5 pieces |
||
185 |
Full hip joint without cement |
30 |
Set |
Combined with previous operating tools
1. Variocup Pressfit: Compressed with many compressed teeth, Titanium Ti-6al-4V alloy material with a bearing axle lock mechanism, with 3 screws, including diameter of 42mm-68mm, 2mm increase.
2. Poly liner (Highly Cross-Linked Uhmwpe) is durable to increase abrasion resistance, with an anti-disordered shore of 15 degrees. The lining is locked safely by the Ring-Lock fixed system.
3. The femur: Ceramic material (Alumina -Zirconia ISO 6474-2), 28mm (-3.5mm, 0mm, +3.5mm), 32mm (-4mm, 0mm, +4mm, +7mm), 36mm (-4mm, 0mm, +4mm, +8mm), 40mm (-4mm, 0mm, 0mm, +4mm, +8mm). Taper 12/14
4. Do not use the Varioloc Ha Pressfit Titanium Alloy Ti-6al-4V. Horizontal groove against subsidence and vertical grooves against rotation with bone cutting line 41 degrees. The neck corner of the body is 131 °, the neck is 12/14mm, with 10 sizes 7.5: 114mm (offset c: 31mm; d: 36mm), 9: 117mm (offset c: 31mm; d: 37mm), 10: 119mm (offset c: 34mm; d: 40mm), 11: 121mm (Offset C: 34mm; D: 41mm), 12.5: 124mm (Offset (offset (offset (offset (offset (offset (offset (offset. C: 34mm; D: 41mm), 13.5: 126mm (Offset C: 37mm; D: 45mm), 15: 129mm (Offset C: 37mm; D: 45mm), 16: 132mm (Offset C: 37mm; D: 46mm), 17.5: 134mm (Offset C: 37mm; D: 47mm), 20: 139mm (Offset C: 37mm; D: 38mm).
.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/5 pieces |
||
186 |
Full hip joint without cement |
20 |
Set |
Combined with previous operating tools
1. The Variocup TPS Coating Carpet: Titanium plasma, Titanium Ti-6al-4V alloy material with a bearing mechanism, with 3 screws, including the diameter of 42mm-68mm, 2mm increase.
2. Poly liner (Highly Cross-Linked Uhmwpe) is durable to increase abrasion resistance, with an anti-disordered shore of 15 degrees. The lining is locked safely by the Ring-Lock fixed system.
3. The femur: Cocrmo alloy material, 28mm (-3.5mm, 0mm, +3.5mm, +7mm, +10.5mm), 32mm (-4mm, 0mm, +4mm, +7mm, +10.5mm), 36mm (-4mm, 0mm, +4mm, +8mm, +10.5mm). Taper 12/14
4. The thigh bone does not use Varioloc TPS Pressfit cement Titanium Alloy Ti-6al-4V covered with titanium plasma. Vertical grooves help stimulate the foam bone quickly to cling to the end of the hilt, with a 41 -degree bone cutting line. The neck corner of the body is 131 °, the neck is 12/14mm, with 12 sizes: 5: 109mm (offset c: 31mm; d: 35mm), 6: 111mm (offset c: 31mm; d: 35mm), 7.5: 114mm (offset c: 31mm; d: 36mm), 9: 117mm (offset c: 31mm; d: 37mm) C: 34mm; D: 40mm), 11: 121mm (Offset C: 34mm; D: 41mm), 12.5: 124mm (Offset C: 34mm; D: 41mm), 13.5: 126mm (Offset C: 37mm; D: 45mm), 15: 129mm (Offset C: 37mm; D: 45mm), 162mm (offset C: 37mm; D: 46mm), 46mm) 17.5: 134mm (Offset C: 37mm; D: 47mm), 20: 139mm (Offset C: 37mm; D: 48mm).
.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/5 pieces |
||
187 |
Full hip joint without cement |
20 |
Set |
1. The femoral hilt: the type of self -locking
- Material: Titanium aluminum vanadium alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm.
- The neck corner 135 °. Con 12/14 - 5 ° 40 '.
- The neck of the ellipse and the polished mirror, the neck has a border around
- There is ≥8 size (step 1), length from 130-170mm
2.
- Material: Titanium aluminum vanadium alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm.
- Around the border there are ≥4 nails
- Size: 46-62 steps increased 2
3. Ceramic cushion:
- Material: Biolox Delta Alumina/Zirconia Composite Ceramic
- Con 18 ° 55 '
- Size:
+ Size ≤39 corresponding to the 46, 48 and 32mm diameter drive
+ Size ≤44 corresponding to the 50, 52 and 36mm diameter drive
+ Size ≤48 corresponding to the 54-62 mortar and a 36mm diameter
4. The femur (cap) of ceramic:
- Material: Biolox Delta Alumina Composite Ceramic
-Diameter 32mm (-4, 0, +4), 36mm (-4, 0, +4)
5.
- Material: Titanium aluminum vanadium alloy
- Diameter ≤5.5mm, length 20-45mm increased 5mm
* Gamma ray sterilization
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/5 pieces |
||
188 |
Full hip joint without cement |
20 |
Set |
Combined with previous operating tools
1. Variocup Pressfit: Compressed with many compressed teeth, Titanium Ti-6al-4V alloy material with a bearing axle lock mechanism, with 3 screws, including diameter of 42mm-68mm, 2mm increase.
2. Poly liner (Highly Cross-Linked Uhmwpe) is durable to increase abrasion resistance, with an anti-disordered shore of 15 degrees. The lining is locked safely by the Ring-Lock fixed system.
3. The femur: Cocrmo alloy material, 28mm (-3.5mm, 0mm, +3.5mm, +7mm, +10.5mm), 32mm (-4mm, 0mm, +4mm, +7mm, +10.5mm), 36mm (-4mm, 0mm, +4mm, +8mm, +10.5mm). Taper 12/14
4. Do not use the Varioloc Ha Pressfit Titanium Alloy Ti-6al-4V. Horizontal groove against subsidence and vertical grooves against rotation with bone cutting line 41 degrees. The neck corner of the body is 131 °, the neck is 12/14mm, with 10 sizes 7.5: 114mm (offset c: 31mm; d: 36mm), 9: 117mm (offset c: 31mm; d: 37mm), 10: 119mm (offset c: 34mm; d: 40mm), 11: 121mm (Offset C: 34mm; D: 41mm), 12.5: 124mm (Offset (offset (offset (offset (offset (offset (offset (offset. C: 34mm; D: 41mm), 13.5: 126mm (Offset C: 37mm; D: 45mm), 15: 129mm (Offset C: 37mm; D: 45mm), 16: 132mm (Offset C: 37mm; D: 46mm), 17.5: 134mm (Offset C: 37mm; D: 47mm), 20: 139mm (Offset C: 37mm; D: 38mm).
5. Screws Titanium Taro Considers have a diameter of 6.5mm from 15-70mm length.
* Product origin: Europe
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/5 pieces |
||
189 |
Full hip joints without cement covered with 2 layers of porous titanium + HA |
20 |
Set |
1. Stem (STEM):
- Material: Titanium Aluminum NiiBium (Ti6al7NB) - ISO5832/11.
- Capital coat: 2 layer 300µm Titanium pure foam + 50µm hydroxyapatite by plasma spray technology.
- Structure: There are many vertical and horizontal grooves around the body of the stem
- Hepers size: There are 12 sizes from 1/130.3mm; 2/140, 3mm; 3/145.4mm; 4/150.4mm; 5/155.5mm; 6/160.5mm; 7/165.5mm; 8/170.4mm; 9/175.4mm; 10/179.9mm; 11/185.4mm; 12/190.4mm.
- Angle neck: 12/14, 5º43'30 ''
- Offset: There are 2 types of offset standard CCD: 135º (38.6mm; 39.3mm; 40mm; 40.8mm; 41.5mm; 42.2mm; 42.9mm; 43.6mm; 44.1mm; 45.6mm); Lateralized CCD: 127º (44.9mm; 45.5mm; 46.3mm; 47.0mm; 47.7mm; 48.4mm; 49.1mm; 49.8mm; 50.3mm; 51.8mm)
- The method of disinfecting radiation with 25 kgy, or VH2O2 method
2. Femoral head:
- Material: Cobalt Chromium Molibdenum - ISO5832/12.
-Diameter: 22mm (-2; +0; +2), 28mm (-3.5; +0; +3.5; +7), 32mm (-4; +0; +4; +8), 36mm (-3.5; +0; +3.5; +7).
3. The mortar (shell):
- Material: Titanium aluminum vanadium (Ti6al4V) - ISO5832/3.
Cover: 500µm Titanium pure with Plasma spray technology.
- Size: There are 15 sizes from 42–70mm with each step increasing 2mm.
- Suitable for all types of cushioning.
- Structure: There is a locking system that holds the cushion tightly, the screw button is removable, the outer rim has the edge to optimize the press-fit closing
4. Liner (liner):
-Material: High molecular polyethylene (Ultra-High-Molecular-Weight Polyethylene (UHMWPE) without calcium stearate-ISO5834/1/2, with anti-disordered edges: 0º; 10º; 20º.
- Size ∅: 22mm; 28mm; 32mm; 36mm, 40mm.
5. Screw of a mortar (Screw): Titanium aluminum vanadium (Ti6al4V), 6.5mm diameter, length: 20-50mm (each step increased by 5mm), 50-60mm (each step increased 10mm).
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
5cs/set |
||
190 |
Full hip joint without cement cement, Titanium cover |
30 |
Set |
1. Stem (STEM):
- Titanium aluminum vanadium (Ti6al4V) -ISO5832/3. Cover: 500µm Titanium pure porous by plasma spray technology. The surface structure has many grooves running along the stem.
- Size: There are 10 sizes 6.25/137mm; 7.5/137mm; 8.75/139.5mm; 10/142mm; 11.25/146.5mm; 12.5/147mm; 13.75/151.5mm; 15/152mm; 17.5/162.5mm; 20/162.5mm
- An corner of the hilt: 135º, neck 12/14 (angle above 5º42'30 '').
- Offset: 2 types of standard (34.8mm; 36.1mm; 37.0mm; 37.4mm; 38.2mm; 38.7mm; 41.4mm); Lateralized (41.1mm; 42.4mm; 43.5mm; 43.7mm; 44.8mm; 45.7.7mm)
- The method of disinfecting radiation with 25 kgy, or VH2O2 method
2. Femoral head:
- Material: Cobalt Chromium Molibdenum - ISO5832/12.
-Diameter: 22mm (-2; +0; +2), 28mm (-3,5; +0; +3,5; +7).
3. The mortar (shell):
- Material: Titanium aluminum vanadium (Ti6al4V) - ISO5832/3.
Cover: 500µm Titanium pure with Plasma spray technology.
- Size: There are 15 sizes from 42–70mm with each step increasing 2mm.
- Suitable for all types of cushioning.
- Structure: There is a locking system that holds the cushion tightly, the screw button is removable, the outer rim has the edge to optimize the press-fit closing
4. Bioloy metal lining:
- Material: High nitrail stainless steel alloy PM734, covered with tinbn.
5. Cushion class:
-Material: High molecular polyethylene (Ultra-High-Molecular-Weight Polyethylene (UHMWPE) Calcium Stearate)-ISO5834/1/2/2
- Inner diameter: 22mm, 28mm.
- External diameter: There are 5 sizes 36mm-46mm.
6. Screws of the mortar (Screw): Titanium aluminum vanadium (Ti6al4V), 6.5mm diameter, length: 20-50mm (each step increased by 5mm), 50-60mm (each step increased 10mm).
* Product origin: G7
* Meet the standard: ISO and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
6 Conscans/set |
||
191 |
Full hip joints without cement, long grip, double -moving mortar with cement with a cross -shaped base |
20 |
Set |
1.
- Material: Titanium aluminum vanadium alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm
- The corner of the neck is 130 degrees. Con 12/14 - 5 ° 40 '
-Locking screw with 5.5mm diameter, 28-55mm long, 5.5mm diameter adjustment screws, 30-35mm long
-Size: 12-16 (step 2), length 200-300mm
- Gamma rays
2. The thigh bone (core):
- Material: stainless steel
-Diameter 22.2mm (-2, 0, +3), diameter 28mm (-3.5, 0, +3.5)
- Gamma rays
3. Fears + braces:
- Flares:
+ Material: Cobalt-Chromium-Molybdenum alloy
+ Size: 44-60
- Brace:
+ Material: stainless steel
+ Cross shape
+ There are 4 holes to screw, screw with a diameter of 5.0mm
+ Size: 4, 5, 6
- Gamma rays
4.
- Material: Polyethylene
- Double movement cushion layer
- Size: 44-60 (Step 2)
- Pure with ethylene oxide
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/4 pieces |
||
192 |
The full hip joints of the artificial motion without cement |
40 |
Set |
1. The femoral hilt: the type of self -locking
- Material: Titanium aluminum vanadium alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm
- The neck corner 135 °. Con 12/14 - 5 ° 40 '
- The neck of the ellipse and the mirror is polished
- There is ≥9 size (step 1), length from 87-170mm.
2. The thigh tip (tip) and the cushion:
- The femur (tip):
+ Material: Alumina Ceramic
+ Diameter 28mm (-3.5, 0, +3.5)
- Buffer layer:
+ Material: Polyethylene
+ Size: 48-60 (step 2)
- The buffer layer is installed with the tap at the company
3. The nest: The mortar does not screw
-Material: Cobalt-Chromium-Molybdenum alloy
- Cover 2 layers: Titanium ≥120µm and hydroxyapatite ≥80µm
- The outside: around the edge is ≥6 nails, on the top is ≥4 nails
- Inner surface: polished with roughness <0.05µm
- There is an orderly rim of 5mm with ≥2 marking points
- There are cups (plates) installed under vacuum pressure
- Kich size: 48-60 (step 2)
* Gamma ray sterilization
* Product origin: G7
* Standard: ISO 13485 and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Set/3 pieces |
||
193 |
Lock splint around the femur |
20 |
Female |
1. Brace:
- Material: stainless steel
- Size: Length equivalent to 200mm, 249mm
- The body of the splint: ≤16 lock holes
- Use a lock screw of 3.5mm in diameter, about 10-70mm long
- Can be used with Titanium lock eye and steel wire
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
194 |
Lock splint around the joint (knee), the lower end of the femur |
10 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent 139mm, 179mm, 254mm
- The splint head: ≤7 lock holes
- The body of the splint: ≤8 lock holes
- Use a 5.0mm diameter lock screw, about 12-110mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
195 |
The head locks under the tibia |
20 |
Female |
1. Brace:
- Material: stainless steel
- Size: Length equivalent to 130mm, 190mm
- The splint head: ≤7 lock holes
- The body of the splint: ≤8 holes
- Using a 3.5mm diameter lock screw, about 10-70mm long; Screw of 3.5mm diameter bone shell, about 12-70mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
196 |
The head locks under the bone |
30 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 80mm, 108mm, 150mm
- The splint head: ≤5 holes
- The body of the splint: ≤9 holes
- Using 2.5mm diameter lock screws, about 8-50mm long; Screw of 2.7mm diameter bone shell, about 10-40mm long; Screw of 3.5mm diameter bone shell, about 40-62mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
197 |
The head locks under the rotating bone |
30 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 48mm, 53mm
- The splint head: ≤7 lock holes
- The body of the splint: ≥3 holes
- Using 2.5mm diameter lock screws, about 8-50mm long; Bone screw with a diameter of 2.7mm, about 10-40mm long.
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Genuine sterilization packaging
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
198 |
The lower buckle brace, the elbow of the arm bone |
30 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 98mm, 143mm
- The splint head: ≤5 lock holes
- The body of the splint: ≤7 lock holes
-Use a 2.5mm diameter lock screw, about 8-50mm long, 3.5mm diameter lock screws, about 10-70mm long.
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
199 |
The head lock is on the outside of the tibia |
20 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 83mm, 143mm, 203mm
- The splint head: ≤4 lock holes
- The body of the splint: ≤8 lock holes
- Use a 5.0mm diameter lock screw, about 12-110mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
200 |
The head lock on the arm bone |
20 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 82mm, 125mm
- The splint head: ≤7 lock holes
- The body of the splint: ≤6 holes
- Using a 3.5mm diameter lock screw, about 10-70mm long; Screw of 3.5mm diameter bone shell, about 12-70mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
201 |
The brace of the elbow, the head on the L -shaped cylindrical bone |
30 |
Female |
1. Brace:
- Material: stainless steel
- Size: Length ≥105mm
- The splint head: ≤5 lock holes
- The body of the splint: ≤4 lock holes
- Using 2.5mm long-meter lock screws in the range of 8-50mm; Lock screw with a diameter of 3.5mm, about 10-70mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Genuine sterilization packaging
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
202 |
The thigh bone lock brace |
20 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 190mm, 240mm, 290mm
- The body of the splint: ≤12 holes
- Use a 5.0mm diameter lock screw, about 12-110mm long
- Can be used with Titanium lock eye and steel wire
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
203 |
Straight brace of forearm bone, cylindrical bone |
20 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 79mm, 111mm, 145mm
- The body of the splint: ≤8 holes
- Using a 3.5mm diameter lock screw, about 10-70mm long; Screw of 3.5mm diameter bone shell, about 12-70mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Genuine sterilization packaging
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
204 |
The brace locks the tibia and the arm bone |
40 |
Female |
1. Brace:
- Material: stainless steel
- Size: Length equivalent to 122mm, 169mm, 209mm, 249mm
- The body of the splint: ≤12 holes
- Use a 5.0mm diameter lock screw, about 12-110mm long
- Can be used with Titanium lock eye and steel wire
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
205 |
Lock bone brace |
30 |
Female |
1. Brace:
- Material: stainless steel
- Size: length equivalent to 70mm, 94mm, 95mm
- Separate body: ≤6 lock holes
- Use a lock screw of 3.5mm in diameter, about 10-70mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
206 |
The collarbone lock is hooked |
10 |
Female |
1. Brace:
- Material: stainless steel
- Size: Length ≤63mm
- The splint head: ≤3 lock holes
- The body of the splint: ≤3 lock holes
- Use a lock screw of 3.5mm in diameter, about 10-70mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
207 |
Heel bone bone brace |
20 |
Female |
1. Brace:
- Material: titanium
- Size: length equivalent to 56mm, 67mm
- The body of the splint: ≤11 lock holes
- Use a 2.5mm diameter lock screw, about 8-50mm long
2.
- Material: Titanium ti6al4v
- Be pre -installed on braces
- Design for cone screw head ≥2 degrees
- Be encoded by color
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
208 |
Lock |
200 |
Female |
- Material: Titanium ti6al4v
- Self -creation thread
- The cone screw head ≥2 degrees
- Size:
+ Diameter: 2.5mm
+ Length: in the range of 8-50mm
- Compatible with braces of the same company
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
209 |
Lock |
200 |
Female |
- Material: Titanium ti6al4v
- Self -creation thread
- The cone screw head ≥2 degrees
- Size:
+ Diameter: 3.5mm
+ Length: in the range of 10-70mm
- Compatible with braces of the same company
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
210 |
Lock |
300 |
Female |
- Material: Titanium ti6al4v
- Self -creation thread
- The cone screw head ≥2 degrees
- Size:
+ Diameter: 5.0mm
+ Length: in the range of 12-110mm
- Compatible with braces of the same company
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
211 |
Titanium screw |
200 |
Female |
- Material: Titanium ti6al4v
- Self -creation thread
- The cone screw head ≥2 degrees
- Size:
+ Diameter: 2.7mm
+ Length: in the range of 10-40mm
- Compatible with braces of the same company
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
212 |
Titanium bone screw |
200 |
Female |
- Material: stainless steel
- Self -creation thread
- The cone screw head ≥2 degrees
- Size:
+ Diameter: 3.5mm
+ Length: in the range of 12-70mm
- Compatible with braces of the same company
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box/1 piece |
||
213 |
Bone cement |
20 |
Box |
Cement used in artificial joint surgery.
1. Cement has average viscosity:
- Average viscosity
- Mixed by hand
- Ingredient:
+ 14.4g liquid form includes: methylethacrylate (85.3%), butylmethacrylate (13.2%), N, N-Dimethyl-P-Toluidine (1.5%Max), hydroquinone (20ppm).
+ 40g powder form: Polymethyl-methacrylate (87.6%), benzoyl peroxide (2.4%), barium sulfate (10%).
- Mixing time to put into joints: 7 ± 1 minute.
2. Cement has low viscosity:
- Low viscosity
- Use of cylinder
- Ingredient:
+ Liquid form 16.4g includes: methermethacrylate (85.3%), butylmethacrylate (13.2%), N, N-Dimethyl-P-Toluidine (1.5%Max), Hydroquinone (20ppm)
+ 40g powder form includes: polymethyl-methacrylate (87.3%), benzoyl peroxide (2.7%), barium sulfate (10%).
+ Mixing time to put into joints: 9 ± 1 minute.
* Product origin: G7
* Standard: ISO 13485, and CE (Europe)
(or equivalent) |
Department of Pharmacy S.I.S International General Hospital Can Tho. No. 397 Nguyen Van Cu Street, An Binh Ward, Can Tho City |
Box |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor BỆNH VIỆN ĐA KHOA QUỐC TẾ S.I.S CẦN THƠ - CHI NHÁNH CÔNG TY CỔ PHẦN ĐẦU TƯ Y TẾ VIỆT CƯỜNG:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding BỆNH VIỆN ĐA KHOA QUỐC TẾ S.I.S CẦN THƠ - CHI NHÁNH CÔNG TY CỔ PHẦN ĐẦU TƯ Y TẾ VIỆT CƯỜNG:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.