Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Chemicals to determine quantitative alat (GPT) |
5 |
Box |
- Chemicals for testing for quantitative alat (GPT) in serum or plasma
- Measuring method: UV test is optimized according to IFCC
- Ingredient:
R1:
Tris pH 7.15: 140 mmol/l
L-alanine: 700 mmol/l
LDH (lactate dehydrogenase) ≥ 2300 u/l
R2:
2-Oxoglutarate: 85 mmol/l
NADH: 1 mmol/l
Pyridoxal-5-phosphate fs
Good’s buffer pH 9.6: 100 mmol/l
Pyridox-5-phosphate: 13 mmol/l
- Measurement range: up to 1000 U/L. |
Minh Hoa District General Hospital |
8x60ml/8x15ml |
Au automatic biochemical machine 480 |
|
2 |
ASAT quantitative testing chemicals (GOT) |
5 |
Box |
- ASAT quantitative testing chemicals in test tubes (GOT) in human serum or plasma
- Measuring method: UV test is optimized according to IFCC
- Ingredient:
+ R1: Tris pH 7.65 110 mmol/l
L-Espartate 320 mmol/l
MDH (Malate dehydrogenase) ≥ 800 U/L
LDH (lactate dehydrogenase) ≥ 1200 u/l
+ R2: 2-oxoglutarate 85 mmol/l
NADH 1 mmol/l
Pyridoxal-5-phosphate fs
Good’s Buffer PH 9.6 100 mmol/l
Pyridox-5-phosphate 13 mmol/l
- Measurement range: up to 600 U/l. |
Minh Hoa District General Hospital |
8x60ml/8x15ml |
Au automatic biochemical machine 480 |
|
3 |
Chemicals to determine quantitative albumin |
2 |
Box |
- Chemicals for testing to determine the quantitative albumin in serum or plasma
- Measuring method: Optical measurement test uses bromocresol green
- Ingredient:
Citrate buffer pH 4.2: 30 mmol/l
Bromocresol Green: 0.26 mmol/l
- The measuring range is up to 6 g/dl |
Minh Hoa District General Hospital |
10x60mL |
Au automatic biochemical machine 480 |
|
4 |
Chemical tests to quantify bilirubin directly |
3 |
Box |
- Chemicals tested to quantify bilirubin directly in serum or plasma.
- Measuring method: Optical measurement test uses 2.4-dichloroaniline (DCA).
- Ingredient:
R1: EDTA-NA2: 0.1 mmol/l
NaCl: 150 mmol/l
Sulfamic Acid: 100 mmol/l
R2: 2,4-dichloroaniline: 0.5 mmol/l
HCl: 900 mmol/l
EDTA-NA2: 0.13 mmol/l
- Measurement range: up to 10 mg/dl |
Minh Hoa District General Hospital |
4x20ml/2x10ml |
Au automatic biochemical machine 480 |
|
5 |
Chemicals for quantitative bilirubin quantitative |
1 |
Box |
- Chemical tests to quantify the total bilirubin in human serum or plasma
- Measuring method: Optical tests use 2.4-dichloroaniline (DCA).
- Ingredient :
R1: Phosphate buffer: 50 mmol/l
NaCl: 150 mmol/l
R2: 2,4-dichloroaniline: 5 mmol/l
HCl: 130 mmol/l
- Measurement range up to 30 mg/dl |
Minh Hoa District General Hospital |
8x60ml/8x15ml |
Au automatic biochemical machine 480 |
|
6 |
CK-MB quantitative testing chemicals |
2 |
Box |
- Chemicals for testing to determine the quantitative CK-MB in human serum or plasma
- Ingredient:
+ R1: Imidazole/Good’s Buffer 120 mmol/l
Glucose 25 mmol/l
N-acetylcysteine (NAC) 25 mmol/l
Magnesium acetate 12.5 mmol/l
Edta-na2 2 mmol/l
NADP 2.5 mmol/l
Hexokinase (HK) ≥ 5 ku/l
CK-M antibodies (mice); The ability to inhibit ≥ 2500 u/l
+ R2: Imidazole/Good’s Buffer 90 mmol/l
ADP 10 mmol/l
AMP 28 mmol/l
Glucose-6-phosphate dehydrogenase (G6P-DH) ≥ 15 ku/l
Diadenosine pentaphosphate 50 µmol/l
Creatine phosphate 150 mmol/l
- Measurement range: 9 to 1900 U/L |
Minh Hoa District General Hospital |
4x20ml/2x10ml |
Au automatic biochemical machine 480 |
|
7 |
Chemicals Determining quantitative cholesterol |
3 |
Box |
- Chemicals for testing to determine quantitative cholesterol in serum or human plasma
- Method: ChoD-PAP ": Enzyme spectrum test.
- Ingredient:
Good's buffer pH 6.7: 50 mmol/l
Phenol: 5 mmol/l
4-Aminoantipipipipine: 0.3 mmol/l
Cholesterol esterase (cover): ≥ 200 u/l
Cholesterol oxidase (for): ≥ 50 U/L
Peroxidase (POD): ≥ 3 ku/l
- Measurement range: up to 750 mg / dl |
Minh Hoa District General Hospital |
6x100ml |
Au automatic biochemical machine 480 |
|
8 |
Chemical tests to determine quantitative creatinine (jaffé) |
6 |
Box |
- Chemicals for testing to determine the quantity of creatinine in human serum, plasma or urine
- Method: Jaffé
- Ingredient:
+ R1: Sodium hydroxide 0.2 mol/l
+ R2: Picric acid 20 mmol/l
- Measurement range: up to 14 mg/dl |
Minh Hoa District General Hospital |
8x60ml/8x15ml |
Au automatic biochemical machine 480 |
|
9 |
Chemical tests to determine quantitative glucose |
6 |
Box |
- Chemicals for testing to determine quantitative glucose in human serum or plasma
- Method: God-Pap
- Ingredient:
Phosphate buffer pH 750 mmol/l
Phenol 5 mmol/l
4-Aminoantipipipipipipine 0.5 mmol/l
Glucose Oxidase (God) ≥ 10 ku/l
Peroxidase (POD) ≥ 1 Ku/L
- Measurement range: from 0.43 mg/dL to 500 mg/dl |
Minh Hoa District General Hospital |
6x100ml |
Au automatic biochemical machine 480 |
|
10 |
Chemical tests to determine quantitative LDL-C (low-density lipoprotein cholesterol) |
10 |
Box |
- Chemicals for testing LDL-C quantitative (low-density lipoprotein) in human serum or plasma serum
- Ingredient:
+ R1: Buffer pH 6.65 20 mmol/l
Peroxidase (POD) ≥ 2000 U/L
N- (2-Hydroxy-3-Sulfopropyl)-3.5-Dimethoxyaniline sodium Salt (H-DAOS) ≥ 0.7 mmol/l
+ R2: Buffer pH 8.15 20 mmol/l
Cholesterol esterase (cover) ≥ 2000 U/l
Cholesterol oxidase (for) ≥ 2000 U/l
Peroxidase (POD) ≥ 15000 U/L
4-Aminoantipipipipine (4-AA) ≥ 1.5 mmol/l
- Measurement range: up to 500 mg/dl |
Minh Hoa District General Hospital |
4x20ml/2x10ml |
Au automatic biochemical machine 480 |
|
11 |
Chemicals for testing to determine the quantification of the total protein |
2 |
Box |
- Chemicals for testing to determine the quantification of total protein in human serum or plasma
- Ingredient:
+ R1: Sodium hydroxide 100 mmol/l
Potassium sodium tartrate 17 mmol/l
+ R2: Sodium hydroxide 500 mmol/l
Potassium sodium tartrate 80 mmol/l
Potassium iodide 75 mmol/l
Sulphate 30 mmol/l
- Measurement range: up to 14 g/dl |
Minh Hoa District General Hospital |
8x60ml/8x15ml |
Au automatic biochemical machine 480 |
|
12 |
Chemicals for testing triglycerides quantitative |
3 |
Box |
- Chemicals for testing to determine triglycerides in human serum or plasma
-Method: Testing for color comparison using glycerol-3-phosphate-oxidase (GPO)
- Ingredient:
Good's buffer pH 7.2 50 mmol/l
4-Chlorophenol 4 mmol/l
ATP 2 mmol/l
Mg2+ 15 mmol/l
Glycerokinase (GK) ≥ 0.4 ku/l
Peroxidase (POD) ≥ 2 ku/l
Lipoprotein lipase (LPL) ≥ 2 ku/l
4-Aminoantipipipipipipine 0.5 mmol/l
Glycerol-3-phosphate-oxidase (GPO) ≥ 0.5 ku/l
- Measuring range: up to 1000 mg/dl |
Minh Hoa District General Hospital |
6x100ml |
Au automatic biochemical machine 480 |
|
13 |
Chemicals for testing to determine quantitative urea |
6 |
Box |
- Chemicals for testing to determine quantitative urea in human serum, plasma or urine
- Ingredient:
+ R1: Tris pH 70 mmol/l
2-Oxoglutarate 9 mmol/l
ADP 0.75 mmol/l
Urease ≥ 7 ku/l
GLDH (cow) ≥ 1 ku/l
+ R2: NADH 1.3 mmol/l
- Measuring range: up to 300 mg/dl |
Minh Hoa District General Hospital |
8x60ml/8x15ml |
Au automatic biochemical machine 480 |
|
14 |
Chemicals tested to determine quantitative uric acid |
1 |
Box |
- Chemicals for testing to determine quantitative uric acid in human serum, plasma or urine
- Ingredient:
+ R1: Phosphate buffer PH 7.0 100 mmol/l
1.25 mmol/l
Ascorbate oxidase ≥ 1.2 ku/l
+ R2: Phosphate buffer PH 7.0 100 mmol/l
4-Aminoantipipipipipine 1.5 mmol/l
K4 [Fe (CN) 6] 50 µmol/l
Peroxidase (POD) ≥ 5 ku/l
Uricase ≥ 250 U/l
- Measuring range: up to 20 mg/dl |
Minh Hoa District General Hospital |
8x60ml/8x15ml |
Au automatic biochemical machine 480 |
|
15 |
Chemical tests to determine quantitative α-amylase |
3 |
Box |
'- Chemicals tested to determine quantitative α-amylase in human serum, plasma or urine
- Ingredient:
+ R1: Good's buffer pH 7.15 0.1 mol/l
NaCl 62.5 mmol/l
MgCl2 12.5 mmol/l
α-glucosidase ≥ 2 ku/l
+ R2: Good's buffer pH 7.15 0.1 mol/l
EPS-G7 8.5 mmol/l
- Measurement range: up to 2000 U/L |
Minh Hoa District General Hospital |
4x20ml/2x10ml |
Au automatic biochemical machine 480 |
|
16 |
Chemical tests to determine quantitative C-Reactive Protein (CRP) |
4 |
Box |
- Chemicals for testing to determine the quantitative C-Reactive Protein (CRP) in serum or plasma
- Method: Measuring the turbidity
- Ingredient:
+ R1: Tris pH 7.5 100 mmol/l
+ R2: Tris pH 8.0 100 mmol/l
Anti-Human CRP Antibodies (Goat) <1 %
- Measurement range: 2 mg/l - 250 mg/l. |
Minh Hoa District General Hospital |
8x50ml/8x10ml |
Au automatic biochemical machine 480 |
|
17 |
Calibrated chemicals used in lipid and lp-pla2 quantitative tests |
2 |
Box |
Calibrated chemicals used in lipid and lp-pla2 quantitative tests
Trucal Lipid is a calibration that is dried based on human blood (plasma) materials with additives made from pure materials originating from humans. |
Minh Hoa District General Hospital |
3x2ml |
Au automatic biochemical machine 480 |
|
18 |
Calibrated chemicals used in testing tests |
2 |
Box |
Calibrated chemicals used in testing tests in in vitro different analytical substances on optical measurement system
Trucal u is a calibrating (calibrator) in the form of freezing based on human blood (serum) and contains chemical additives and biological materials of specific origin. |
Minh Hoa District General Hospital |
20x3ml |
Au automatic biochemical machine 480 |
|
19 |
Calibrated chemicals used in ck-mb activity quantitative tests |
2 |
Box |
Calibrated chemicals used in ck-mb activity quantitative tests
Trucal CK-MB is a free-dried calibration based on albumin serum with chemical additives and pure materials of specific origin |
Minh Hoa District General Hospital |
6x1mL |
Au automatic biochemical machine 480 |
|
20 |
Calibrated chemicals used in quantitative tests C Reactive Protein (CRP) |
2 |
Box |
Calibrated chemicals used in quantitative tests C Reactive Protein (CRP)
Liquid |
Minh Hoa District General Hospital |
5x2mL |
Au automatic biochemical machine 480 |
|
21 |
Standard chemicals used in biochemical tests |
4 |
Box |
Standard chemicals used in testing in determining quantitative of many different analysis in in vitro
Trulab N is a standard chemical (Control) based on materials derived from human blood (serum) and contains drugs, organic and inorganic chemicals and biological materials of specific origin. |
Minh Hoa District General Hospital |
6x5ml |
Au automatic biochemical machine 480 |
|
22 |
Standard chemicals used in biochemical tests |
4 |
Box |
Standard chemicals used in testing in determining quantitative of many different analysis in in vitro
Trulab P is a standard dried control. |
Minh Hoa District General Hospital |
6x5ml |
Au automatic biochemical machine 480 |
|
23 |
Standard chemicals used for quantitative testing C-Reactive Protein (CRP), level 1 |
4 |
Box |
Standard chemicals used for quantitative testing C-Reactive Protein (CRP), level 1
Trulab CRP is a standard liquid -based stabilizer. |
Minh Hoa District General Hospital |
3x2ml |
Au automatic biochemical machine 480 |
|
24 |
Standard chemicals used for quantitative testing C-Reactive Protein (CRP), level 2 |
1 |
Box |
Standard chemicals used for quantitative testing C-Reactive Protein (CRP), level 2
Trulab CRP is a standard liquid -based stabilizer. |
Minh Hoa District General Hospital |
3x2ml |
Au automatic biochemical machine 480 |
|
25 |
Biochemical machine washing chemicals |
5 |
Box |
The solution used to wash the biochemical testing machine
Ingredients: Sodium hydroxide 0.5 - 2 % |
Minh Hoa District General Hospital |
6x200ml |
Au automatic biochemical machine 480 |
|
26 |
ALT quantitative test reagents |
12 |
Box |
Chemicals quantitative ALT/GPT on biochemical machine; Specification: R1: 2x50ml + R2: 1x26ml; Measuring range: 10-450 U/L
Ingredients include:
Chemical 1: R1
-Tris buffer, pH 7.50
-L-alanine: 680 mmol/l
-LDH: ≥2000 U/L
-Sodium azide: <0.1% mass/mass
Chemical 2: R2
-Alpha-ketoglutarate: 97 mmol/l
-NADH: 1.1 mmol/l
-Sodium azide: <0.1% mass/mass "
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
R1: 2x50ml + R2: 1x26ml |
Prom biochemical machine |
|
27 |
AST quantitative test reagent |
12 |
Box |
AST/GOT quantitative chemicals on biochemical machines;
* Ingredients include:
Chemical 1: R1
- Tris buffer, pH 7.8
- L-Aspartate: 330 mmol/l
- LDH: ≥ 2000 U/L
- MDH: ≥ 1000 U/L
- Sodium Azide: <0.1% mass/mass
Chemical 2: R2
-Alpha-ketoglutarate: 78 mmol/l
-NADH: 1.1 mmol/l
-Sodium azide: <0.1% mass/mass
- Measurement range: 10-450 U/L
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R1: 2x50ml + R2: 1x26ml |
Prom biochemical machine |
|
28 |
Amylase quantitative test reagent |
10 |
Box |
Amylase quantitative chemicals on biochemical machines;
* Ingredients include:
- Good's buffer, pH 6.15
- CNP-G₃: 2.27 mmol/l
- Sodium Azide: <0.1% mass/mass
- Also contains calcium and chloride salt, as well as potassium thiocyanate for optimal performance
- Measurement range: 20-1500 U/l. |
Minh Hoa District General Hospital |
1 x 50 mL |
Prom biochemical machine |
|
29 |
Cholesterol testing reagents |
2 |
Box |
Chemicals of cholesterol quantitative testing on biochemical machines;
* Chemicals: R
- Good's buffer, pH 6.7
- Phenol: 24 mmol/l
- Cholesterol esterase: ≥ 180 U/l
- Cholesterol oxidase: ≥ 200 u/l
- Peroxidase: ≥ 1000 U/L
- 4-aminoantipipyrin (4-aap): 0.5 mmol/l- sodium azide: <0.1% mass/mass
Also contains Surfactants (surfactants) and Magnesium Salts (magnesium salt) for optimal performance.
Standard substance: STD
- Cholesterol: 200mg/dl
Measuring range: 20 - 600 mg/dl (0.52-15.52 mmol/l)
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R: 6 x 100 ml + STD: 1 x 5 ml |
Prom biochemical machine |
|
30 |
Set of reagents and standards for quantitative Creatinine testing |
7 |
Box |
Creatinine quantitative testing chemicals
Measuring method: Enzymatic/pap- kinetic
Measuring range: Serum/plasma sample 0.1-30 mg/dl, urine 5-450 mg/dl
(0.4-39.8 mmol/l) Ingredients:
Chemical R1:
- Good's buffer, pH 7.5
- EHSPT: 0.4 mmol/l
- Creatinase: ≥ 10000 u/l
- Sarcosine oxidase: ≥ 3500 U/l chemical R2:
- Good's buffer, pH 7.5
- Amino- 4- Antyrine: 2.95 mmol/l
- Creatinase: ≥ 150000 u/l
- Peroxidase: ≥ 4000 U/L
- Sodium Azide: <0.1% mass/mass
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R1: 2x100ml + R2: 1x70ml |
Prom biochemical machine |
|
31 |
Reagent set, standard for quantitative testing of Glucose |
3 |
Box |
Chemicals of glucose quantitative testing on biochemical machines;
* Ingredients include:
Chemicals: R
- Phosphate buffer, pH 7.4
- Phenol: 10 mmol/l
- 4-aminoantipipipin: 0.3 mmol/l
- Peroxidase: ≥ 700 U/L
- Glucose Oxidase: ≥ 10000 U/L
- Sodium Azide: <0.1% mass/mass
Standing substance STD
- D-glucose: 100 mg/dl (5.55 mmol/l)
- Measurement range: 20-400 mg/dL (1.11 - 22.20
mmol/l)
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R: 6 x 100 ml + STD: 1 x 5 ml |
Prom biochemical machine |
|
32 |
Set of reagents and standards for quantitative testing of total protein |
1 |
Box |
Chemicals quantitative protein quantitative plasma/ serum on biochemical machines;
*Ingredients include:
Chemicals: R
- Copper Sulfate: 6 mmol/l
- Sodium hydroxide: 490 mmol/l also contains iodide and tartrate salt for optimal performance
Standard substance: STD
- Albumin 6 g/DL
- Sodium Azide: <0.1% (mass/mass)
-Measurement range: 0.2-12 g/dl (2-120 g/l)
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R: 2x125ml + Std: 1x5ml |
Prom biochemical machine |
|
33 |
Set of reagents and standards for quantitative testing of Triglycerides |
4 |
Box |
Triglycerides quantitative chemicals in plasma/serum people on biochemical testing machines
*Ingredients include:
Chemical R
- Good's buffer, pH 7.0
- P- Chlorophenol: 2.7 mmol/l
- ATP: 3.15 mmol/l
- Amino- 4- Antyrine: 0.31 mmol/l
- Lipoprotein lipase: ≥ 2000 U/l
- Glycerol Kinase: ≥ 500 U/L
- Glycerol- 3- Phosphate oxidase: ≥ 4000 U/L
- Peroxidase: ≥ 500 U/L
- Sodium Azide: <0.1% (mass/mass)
Also contains magnesium, fad and surfactants salt for optimal performance
Standard substance: STD
- Glycerol (similar to triglycerides) 200 mg/dl
- Sodium Azide: <0.1% (mass/mass)
-measuring range 30-1000 mg/dL (0.34-11.30
mmol/l)
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R: 6x50ml + STD: 1x5ml |
Prom biochemical machine |
|
34 |
Set of reagents and standards for quantitative Urea testing |
6 |
Box |
Urea quantitative chemicals in plasma/ serum and urine on biochemical machines;
* Ingredients include:
Chemical 1: R1
- Tris buffer, pH 7.60 (37 ° C)
- Anpha-ketoglutarate: 9 mmol/l
- Urease: ≥ 8100 U/l
- GIDH: ≥ 1350 U/L
- Sodium Azide: <0.1% (mass/ mass)
Chemical 2: R2
- NADH: 1.3 mmol/l
- Sodium Azide: <0.1% (mass/ mass)
Standard substance:
- Urea: 50 mg/dl (8.33 mmol/l)
-Measuring range: Serum/plasma 10-300 mg/dl (1.67-49.95 mmol/l), urine 200-6000 mg/dl (33-999 mmol/l)
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R1: 4x50ml + R2: 2x26ml + STD: 1x5ml |
Prom biochemical machine |
|
35 |
Set of reagents and standards for quantitative uric acid testing |
1 |
Box |
Chemicals quantify uric acid in plasma/ serum and urine on the biochemical testing machine.
*Ingredient:
Chemical R:
- Buffer, pH 7.0 (20-25 ° C)
- EHSPT: 0.72 mmol/l
- Amino- 4- Antyrine: 0.37 mmol/l
- Uricase: ≥ 150 U/L
- Peroxidase: ≥12000 U/L
- Sodium Azide: <0.1% (mass/mass)
Standing substance STD:
- Uric acid: 6 mg/dl (357 µmol/l)
- Sodium Azide: <0.5% (mass/mass)
- Measuring range: Serum/plasma: 1.5-25 mg/dl; Urine: 5-250 mg/dl
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
R: 6x50ml + STD: 1x5ml |
Prom biochemical machine |
|
36 |
Materials control level 1 quantitative tests of biochemical numbers |
8 |
Jar |
Standard chemicals for normal test results for biochemical tests listed in the accompanying value table;
* Ingredients include:
- Freezing serum uses chemical/biological additives.
- The concentration of each analyte for specific inspection in each batch.
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
10 x 5 ml |
Prom biochemical machine |
|
37 |
Test standards for quantitative biochemical parameters |
6 |
Jar |
Calibrated chemicals for biochemical tests listed in the attached value table;
* Ingredient:
- Freezing serum uses chemical/biological additives.
- Sodium Azide <0.1% (mass/mass)
- The concentration of the characteristic analytical substance in each batch.
Quality standard ISO 13485: 2016 or equivalent. |
Minh Hoa District General Hospital |
4 x 3 mL |
Prom biochemical machine |
|
38 |
Washed IVD used for biochemical testing machines |
3 |
Bottle |
Automatic biochemistry washing machine
*Ingredients: Acid Solution (pH 1) Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
1 liter bottle |
Prom biochemical machine |
|
39 |
Washed IVD used for biochemical testing machines |
2 |
Bottle |
Automatic biochemical system washing solution
*Ingredients: Alkaline sodium hypoclorite solution
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
1 liter bottle |
Prom biochemical machine |
|
40 |
Washed IVD used for biochemical testing machines |
2 |
Bottle |
The solution is used to wash the needle and cuvette of the biochemical testing machine.
* Ingredients include:
- Sodium Azide <0.1 % (mass/ mass)
- Also contains surfactants.
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
1 liter bottle |
Prom biochemical machine |
|
41 |
TSH quantitative test reagents |
9 |
Box |
Immunosurtion chemicals (FIA) to determine the quantification of thyroid stimulating hormones (TSH) in the whole blood/serum/plasma plasma.
*Ingredients include cartridge, pipette tip (zip bag), backup cartridge bag, C-TIP (as required), instructions for use and ID chip. Each cartridge is packed in an aluminum bag with two components, partially detected and part of the cartridge.
- Cartridge part contains a test range, a person resistant to TSH in the test line, while the chicken's igy is in the control line.
- The detection (detector) contains people with fluorescent fluorescence, fluorescent fluorescent fluores, bull serum albumin (BSA) as stabilizers and sodium azide in phosphate cushion saline (PBS) as preservatives.
- C - Tip (capillary tip) is a useful tool in the fast test area that requires a small amount of capillary blood from the tip of the finger, the heel position (in newborns) or the ear.
*Working range: Serum/ plasma sample: 0.09-80.0 μiu/ ml
* Total blood samples: 0.4-80.0 μi/ml Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
24 tests/box |
Chemical materials used for AFIAS immunity machines |
|
42 |
T4 quantitative test reagent |
9 |
Box |
Immunicatical testing chemicals (FIA) to determine quantitative thyroxine total number (total t4) in serum/plasma
*Ingredients including cartridge, pipette tip (zip bag), Zip bag containing backup cartridge, instructions for use and ID chip.
Each closed aluminum bag contains two cartridge. Each cartridge is packed in an aluminum bag with three components including a part of cartridge, part of detection (detector) and a part of diluted solution.
- The cartridge containing the membrane is called the interlocking test range
T4-BSA in testing and streptavvidin in the test line
Control.
- The discovery part has a grain containing fluorescent agents
T4 resistance, Biotin-BSA fluorescent complex, albumin of cow serum (BSA) as a stable agent and Sodium Azide as preservatives in Phosphate cushion saline (PBS).
- The diluted solution contains AnS, Tween 20, albumin of beef serum (BSA) as a stable agent and Sodium Azide as preservatives in phosphate cushion saline (PBS).
*Working range: 10.23 - 300.0 nmol/l
Quality standard: ISO 13485 or similar |
Minh Hoa District General Hospital |
24 tests/box |
Chemical materials used for AFIAS immunity machines |
|
43 |
T3 quantitative test reagent |
9 |
Box |
Immunicatical testing chemicals (FIA) to determine the quantitative triiodothyronine (total T3) in human serum/plasma.
*Ingredients including cartridge, pipette tip (zip bag), Zip bag containing backup cartridge, instructions for use and ID chip.
Each closed aluminum bag contains two cartridge. Each cartridge is packed in an aluminum bag with three components including a part of cartridge, part of the finding and a part of the solution
dilute.
- The cartridge part containing the membrane is called the test range
T3-BSA complex in testing and chicken igy in the line
control.
- The discovery part has a fluorescent complex particle
Resistance to T3 people, fluorescent fluorescence, albumin of beef serum (BSA) as a stable agent and Sodium Azide as preservatives in the sodium phosphate buffer solution.
- The diluted solution containing Ans, tween 20, albumin
Cow serum (BSA) makes stabilizers and sodium azide
Preservatives in sodium hydroxide solution (NaOH).
*Working range: 0.77-7.7 nmol/l quality standard: ISO 13485 or
equivalent |
Minh Hoa District General Hospital |
24 tests/box |
Chemical materials used for AFIAS immunity machines |
|
44 |
Hormone group quantitative test control materials |
2 |
Box |
Hormone quantitative testing materials are used in Vitro diagnosis in the quality control of hormone test kit "Hormone Assay Kit". Freezing form.
*Ingredient:
- Control contains standard PRL solution solution, standard TSH stock solution, FSH standard stock solution, gonadotropin chewing, Human (HCG), LH standard stock solution, hydrocortisone, levothyroxine, progesterone, Testosterone standard stock solution, 3.3ʹ, 5-triiodoodo
-L-thyronine and horse serum.
Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
2 levels x 1 mL |
Chemical materials used for AFIAS immunity machines |
|
45 |
Prothrombin Time test reagent |
16 |
Box |
Prothrobin Time test reagent is used to determine prothrombin time (PT) by manual or automatic method. Can be used to test the coagulation factors in external blood clots and common paths.
* Ingredients include:
- Thromboplastin chemicals (freezing) contain rabbit brain extract> 10%, sodium azide <0.01%
- CaCl2 cushion contains sodium azide <0.01%
Stability: 12 days at 2-8 ° C, 1 day at 20-25 ° C.
Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
6x2ml |
Chemistry for Human Clot blood clotting machine |
|
46 |
APTT test reagents |
4 |
Box |
The APTT test set uses ellagic acid activation, which is used to determine the time of thromboplastin part of an active part (APTT) by manual and automatic methods.
Ingredients include:
- Chemicals 1 (6x4ml): APTT-El: rabbit cephalin <1.0%, ellagic acid, sodium azide <0.01%;
- Chemicals 2 (6x4ml): CaCl2 solution 0.02 mol/l, sodium azide <0.01%, salt and stabilizer.
Stable 14 days at 2-8 ° C, 7 days at 20-25 ° C.
Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
6x4mL |
Chemistry for Human Clot blood clotting machine |
|
47 |
Fibrinogen quantitative test reagent |
10 |
Box |
Fibrinogen tests are used to identify plasma fibrinogen by manual and automatic methods.
*Ingredients include:
- Fibrinogen chemicals of freezy 5x2ml, ingredients: Thrombin 80 - 100 IU/ml, sodium azide <0.01%.
- Imidazole buffered saline 1x100ml solution, pH 7.4 ± 0.2, Ingredients: Imidazole 0.05mol/l, cushion and stable substance.
- Standard substance: Plasma fibrinogen reference (freezing) 2x1ml, Ingredients: Human serum, sodium azide <01%.
When stored at 2-8 ° C, the unused vial will be stable until the expiry date. After a 7-day stabilization of chemicals at 2-8 ° C.
Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
5x2mL |
Chemistry for Human Clot blood clotting machine |
|
48 |
The material controlled coagulation tests to normal levels |
2 |
Box |
Standard chemicals, used to monitor the performance of normal blood clotting tests.
The 6x1ml box includes: Eastern dry plasma, Sodium Azide <0.01%. Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
6x1mL |
Chemistry for Human Clot blood clotting machine |
|
49 |
Washed IVD used for coagulation testing machine |
14 |
Box |
The solution is used to clean the needle to prevent cross -contamination on the Humaclot Pro machine.
*Ingredient :
- Buffered Salt Solution
- Imidazole 0.1mol/l
- HCl 0.1mol/l
- Detergent 0.02%
Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
5 x 15 ml |
Chemistry for Human Clot blood clotting machine |
|
50 |
Washed IVD used for coagulation testing machine |
11 |
Box |
The solution is used to regularly clean the washing station, waste pipe, suction needle and pump waste of the Humaclot Pro blood clotting machine, reducing the risk of biological material infection.
Ingredients: Aqueous Solution. Specification: 5 x 15 ml. Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
5 x 15 ml |
Chemistry for Human Clot blood clotting machine |
|
51 |
Coagulation test calibrator |
2 |
Box |
Calibrated chemicals, used for calibration tests for prothrombin time analysis (PT) and antithrombin. Calibrator contains: Samples of plasma, sodium azide <0.01%
Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
4x1ml |
Chemistry for Human Clot blood clotting machine |
|
52 |
Cuvette for blood thunderstorms |
2 |
Box |
CuVette used for Huma Clot Pro automatic blood clotting machine |
Minh Hoa District General Hospital |
6x10x32/box |
Chemistry for Human Clot blood clotting machine |
|
53 |
Multi-parameter electrolyte quantitative test reagents (K, Na, Cl, Ca, pH) |
7 |
Box |
Concentration:
Calibration A: K+ 4 mmol/l, Na+ 140 mmol/l, Cl- 100 mmol/l, Ca2+ 1.25 mmol/l, pH 7.4
Calibration B: K+ 8 mmol/l, Na+ 110 mmol/l, Cl-70 mmol/l, Ca2+ 2.5 mmol/l, pH 7
Main ingredients:
Ammonium molybdate 0.4 mmol/l
100 mmol/l sulfuric acid
Hydrochloric acid 100 mmol/l
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
Cal A: 650ml
Cal B: 200ml |
Chemicals for auto ISE500 automatic electrolytes |
|
54 |
Quantitative testing quality control materials (Na, K, Cl, Ca, pH) |
1 |
Box |
Main ingredients:
KCl, NaCl, NaAC, CaCl2, LiCl, Buffer pH, Surfactive substance, preservatives.
Performance characteristics:
In the cv: k+ ≤1.5%, Na+ ≤1.5%, Cl- ≤1.5%, Ca ++ ≤1.5%, pH ≤1.0%
Between CV: K+ ≤3.0%, Na+ ≤3.0%, Cl- ≤3.0%, Ca ++ ≤5.0%, pH ≤1.0%
Accuracy: K+ ≤2.0%, Na+ ≤1.5%, Cl- ≤3.0%, Ca ++ ≤5.0%, pH ≤1.0%
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
10x1ml |
Chemicals for auto ISE500 automatic electrolytes |
|
55 |
Washing solution for electrolyte analyzers |
1 |
Box |
Main ingredients:
Sodium Hypochlorite (NaClo) 0.4% - 0.5%
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
10x5ml |
Chemicals for auto ISE500 automatic electrolytes |
|
56 |
Washing solution for electrolyting analysts or reagents maintain electrodes on electrolytes |
2 |
Box |
Main ingredients: enzyme: pepsin.
Dilutor: KCl, NaCl, Hydrochloride Acid. Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
3x2ml |
Chemicals for auto ISE500 automatic electrolytes |
|
57 |
Electrode solution for electrolyte analyzers |
1 |
Box |
Main ingredients:
KCl, NaCl, NaAC, CaCl2, LiCl, pH cushion, surfactants, preservatives.
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
5x0.8ml |
Chemicals for auto ISE500 automatic electrolytes |
|
58 |
Electrode solution for electrolyte analyzers |
1 |
Jar |
Main ingredients:
KCl, NaCl, NaAC, CaCl2, pH buffer solution and preservatives
Quality standard ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
20ml |
Chemicals for auto ISE500 automatic electrolytes |
|
59 |
K+ quantitative test electrode |
1 |
The |
Electrode electrode
Compatible with electric analysts model Auto ISE500
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
The |
Chemicals for auto ISE500 automatic electrolytes |
|
60 |
Na+ quantitative test electrode |
1 |
The |
Na Electrode electrode
Compatible with electric analysts model Auto ISE500
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
The |
Chemicals for auto ISE500 automatic electrolytes |
|
61 |
Cl- quantitative test electrode |
1 |
The |
CL Electrode electrode
Compatible with electric analysts model Auto ISE500
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
The |
Chemicals for auto ISE500 automatic electrolytes |
|
62 |
Ca+ quantitative test electrode |
1 |
The |
Electrode electrode
Compatible with electric analysts model Auto ISE500
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
The |
Chemicals for auto ISE500 automatic electrolytes |
|
63 |
pH quantitative test electrode |
1 |
The |
Electrode electrode
Compatible with electric analysts model Auto ISE500
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
The |
Chemicals for auto ISE500 automatic electrolytes |
|
64 |
Reference quantitative test electrode |
2 |
The |
Ref electrode electrode
Compatible with electric analysts model Auto ISE500
Quality standard ISO 13485: 2016 |
Minh Hoa District General Hospital |
The |
Chemicals for auto ISE500 automatic electrolytes |
|
65 |
Solution used to dilute for use in hematology machines |
40 |
bin |
Uses: The solution is used for dilution used for hematurian machine. Storage: At 5 - 30 degrees C.
After opening the lid stable within 60 days.
Ingredients: Sodium chloride 6.38 g/l, boric acid 1 g/l, sodium. Tetraborate 0.2 g/l, EDTA-2K 0.2 g/l.
Quality standard ISO 13485: 2016 or equivalent. |
Minh Hoa District General Hospital |
1x20 liters |
Hematology machine XP100 |
|
66 |
Red blood cell lysate solution |
50 |
Bottle |
Uses: The solution of red blood cells, helps to accurately count the number of white blood cells. Storage: 2 - 35 degrees Celsius
After opening the lid stable within 90 days.
Ingredients: Organic Quatnary Ammonium Salt 8.5g/L and Sodium Chloride 0.6g/L.
Quality standard ISO 13485: 2016 or equivalent. |
Minh Hoa District General Hospital |
3x500ml box (500ml bottle) |
Hematology machine XP100 |
|
67 |
Hematology machine cleaning solution |
4 |
Jar |
Uses: Strong alkaline solution is used to wash the hematological system.
Bao Bao is at 1 - 30 degrees Celsius, in the dark, avoid direct sunlight
After opening the lid stable within 60 days.
Ingredients: Sodium hypochlorite 5%. Quality standard ISO 13485: 2016 or equivalent. |
Minh Hoa District General Hospital |
1x50ml |
Hematology machine XP100 |
|
68 |
Low control materials for quantitative tests of 22 hematological parameters |
6 |
Box |
Uses: Standard substance of hematological testing machine
Storage: From 2 - 8 degrees Celsius
After opening the lid stable within 7 days
Ingredients: containing red blood cells, white blood cells, platelets and stabilizers
Quality standard ISO 13485: 2016 or equivalent. |
Minh Hoa District General Hospital |
1x 1.5ml |
Hematology machine XP100 |
|
69 |
Materials control normal levels of quantitative tests of 22 hematology parameters |
6 |
Box |
Uses: Standard substance of hematological testing machine
Storage: From 2 - 8 degrees Celsius
After opening the lid stable within 7 days
Ingredients: containing red blood cells, white blood cells, platelets and stabilizers
Quality standard ISO 13485: 2016 or equivalent. |
Minh Hoa District General Hospital |
1x 1.5ml |
Hematology machine XP100 |
|
70 |
High levels of control materials quantitative test of 22 hematology parameters |
6 |
Box |
Uses: Standard substance of hematological testing machine
Storage: From 2 - 8 degrees Celsius
After opening the lid stable within 7 days
Ingredients: containing red blood cells, white blood cells, platelets and stabilizers
Quality standard ISO 13485: 2016 or equivalent. |
Minh Hoa District General Hospital |
1x 1.5ml |
Hematology machine XP100 |
|
71 |
Demated chemicals for hematological testing machines |
30 |
bin |
Ingredients: - Sodium Chloride <0.9 % - Sodium Sulphate <1.2 % - Buffer <1.1
% - Stabiliser <0.01% - Aqua
Quality standard ISO 13485: 2016 or equivalent.
Origin: Europe or G7 |
Minh Hoa District General Hospital |
20 liter barrel |
Celltac alpha hematology test machine |
|
72 |
Lysing chemicals used in hematology tests |
40 |
Jar |
Ingredient:
- Potassium cyanide <0.05 %
- Detergent <5.3 %
- Quatnary Ammonium Salt <5.0 % of ISO 13485: 2016 or equivalent standard
Origin: Europe or G7 |
Minh Hoa District General Hospital |
1 liter jar |
Celltac alpha hematology test machine |
|
73 |
Washing chemicals used in hematology tests |
5 |
can. can |
Ingredients: - Sodium chloride <0.9 % - Detergent <1.1 % - Buffer <0.3 % - Stabiliser <0.3 % - Dye <0.0001 %, (5 liter barrel)
Quality standard ISO 13485: 2016 or equivalent
Origin: Europe or G7 |
Minh Hoa District General Hospital |
5 liter bucket |
Celltac alpha hematology test machine |
|
74 |
Washing chemicals used in hematology tests |
3 |
Bottle |
Ingredient:
Sodium Chloride <1.5%. Potassium chloride <0.03%. Proteolytic enzymes <0.3%. Detergent <0.4%.
Stabiliser <0.3%.
Quality standard ISO 13485: 2016 or equivalent.
Origin: Europe or G7 |
Minh Hoa District General Hospital |
1 liter jar |
Celltac alpha hematology test machine |
|
75 |
Chemicals for blood type A |
20 |
Jar |
Reagents detect blood type A in human blood samples |
Minh Hoa District General Hospital |
10ml |
Chemicals to determine blood type |
|
76 |
Blood type b -identifying chemicals |
20 |
Jar |
Reagents detect blood type B in human blood samples |
Minh Hoa District General Hospital |
10ml |
Chemicals to determine blood type |
|
77 |
Chemicals for blood type AB |
5 |
Jar |
Reagents detect blood type AB in human blood samples |
Minh Hoa District General Hospital |
10ml |
Chemicals to determine blood type |
|
78 |
Chemicals for identification of blood type d system RH |
20 |
Jar |
The reagent detects Rho (D) in human blood samples. |
Minh Hoa District General Hospital |
10ml |
Chemicals to determine blood type |
|
79 |
Quick diagnosis test of streptococcal infection |
5 |
Box |
Quick Latex Settlement Test to determine qualitative and semi-quantitative antistreptolysin-O in human serums of streptococcal diseases
Quality standard: ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
100 tests |
Diagnostic biology |
|
80 |
Quick test to find Dengue NS1 antigen early diagnosis of dengue fever |
8.000 |
kiểm TRA |
Dengue Virus NS1 antigen in serum, plasma and total blood of the person. Tray
Sensitivity above99.04%
The specificity above 999.32%
The accuracy is over 99.21%
Quality standard ISO 13485: 2016 " |
Minh Hoa District General Hospital |
25 tests/box |
Diagnostic biology |
|
81 |
Onsite dengue IgG/IGM Combo Rapid Test |
6.000 |
kiểm TRA |
Test testing tray for igm/IgG antiviral antiviral Dengue
IgG clinical performance
Sensitivity above97.68%
The specificity is over 99.32%
Accuracy above 98.49%
IGM clinical performance
Sensitivity above 96.88%
The specificity is above 999.07%
Accuracy of 98.09%
Quality standard ISO 13485: 2016 " |
Minh Hoa District General Hospital |
25 tests/Box |
Diagnostic biology |
|
82 |
Test test tray Distinguish anti-virus antibodies HIV-1 and HIV-2 |
2.000 |
kiểm TRA |
"The test of the immune chromatography is fast to detect the antibodies of HIV 1 and/or HIV 2 in the whole blood, serum or plasma.
Specification: box/40 test, cassette "
Quality standard: ISO 13485: 2016 |
Minh Hoa District General Hospital |
Box of 40 tests |
Diagnostic biology |
|
83 |
HBS antigen -resistant test tray |
2.000 |
kiểm TRA |
"Quick testing detects the antigen of the hepatitis B virus in the serum or plasma of the person.
- Specification: box/40 test, cassette format "
Quality standard: ISO 13485: 2016 |
Minh Hoa District General Hospital |
Box of 40 tests |
Diagnostic biology |
|
84 |
Quantify HBeAg antigen in the blood |
500 |
kiểm TRA |
"Detect qualitative the presence of HBeAg antigen in serum or plasma samples.
Model: Plasma / serum
Sensitivity above 99.8%. The specificity is 999.9%
Quality standard: ISO 13485: 2016 |
Minh Hoa District General Hospital |
Box of 25 tests |
Diagnostic biology |
|
85 |
Test tray for qualitative anti-HCV antibody testing |
200 |
kiểm TRA |
"The tray tests for antibodies of antibodies in serum or human plasma.
There is no cross -reaction: positive for HAV, positive for HBsAg, positive for HEV, positive for HIV, positive for rheumatism (RF), positive with HP antibodies, positive for HCG, positive with IgG toxo, positive for CMA IGM, positive for Carcinoembryonic antigen, positive with ALT, positive with IGM, positive with syphila and positive for syphila.
Specification: box/40 test, cassette "
Quality standard: ISO 13485: 2016 |
Minh Hoa District General Hospital |
Box of 40 tests |
Diagnostic biology |
|
86 |
Test qualitative groups of addictive substances in urine |
700 |
kiểm TRA |
Detecting qualitative groups of addictive substances in urine
The limit:
-Marijuana (THC): 11-nor-Δ9-thc-9- COOH: 50 ng/ml
- Methamphetamine (Met): D-Methamphetamine: 500 ng/ml
- Methylenedioxynethphe tamine amine- Ecstasy (MDMA): 3,4- methylenedioxymethamp hetamine HCl (MDMA): 500 ng/ml
- Morphine (MOP300): Morphine: 300 ng/ml
Quality standard: ISO 13485 |
Minh Hoa District General Hospital |
25 tests/Box |
Diagnostic biology |
|
87 |
Blood sugar test strips |
1.500 |
kiểm TRA |
Comes with blood glucose meters, closed silver separate from sticks, used with Caresens N blood glucose meter
Quality standard: ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
Box of 50 sticks |
Diagnostic biology |
|
88 |
Urine analysis test 10 parameters (URS 10) |
30 |
Box |
The test analysis biography to detect qualitative and quantify the following substances in the urine: Leukocytes, nitrite, urobilinogen, protein, pH, blood, specific gravity, ketone, bilirubin, glucose.
Quality standard: ISO 13485: 2016 |
Minh Hoa District General Hospital |
Box / bottle of 100 sticks |
Diagnostic biology |
|
89 |
Analysis of urine analysis 11 parameters (URS 11) |
100 |
Box |
Test analysis of biographical analysis to detect qualitative and quantify the following substances in urine: leukocytes, nitrite, urobilinogen, protein, pH, blood, specific gravity, ketone, bilirubin, glucose, Ascorbic acid. The test strip used once.
Quality standard: ISO 13485: 2016 |
Minh Hoa District General Hospital |
Box/ bottle of 100 sticks |
Diagnostic biology |
|
90 |
Dental filling material occludes root canals |
2 |
Jar |
Calcium hydroxide powder disinfects in the treatment of pipes.
Quality standard: ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
Jar/10g |
Medical supplies, chemicals for teeth |
|
91 |
The needle inserts dental filling into the root canal |
5 |
Box |
This is a dental tool to bring tooth welding into the marrow with stainless steel hilt
Number 25 is 25mm long |
Minh Hoa District General Hospital |
Box of 4 pieces |
Medical supplies, chemicals for teeth |
|
92 |
The needle inserts dental filling into the root canal |
3 |
Box |
This is a dental tool to bring tooth welding into the marrow with stainless steel hilt
Number 30 is 25mm long
Quality standard: ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
Box of 4 pieces |
Medical supplies, chemicals for teeth |
|
93 |
The needle inserts dental filling into the root canal |
3 |
Box |
This is a dental tool to bring tooth welding into the marrow with stainless steel hilt
Number 30 is 21mm long |
Minh Hoa District General Hospital |
Box of 4 pieces |
Medical supplies, chemicals for teeth |
|
94 |
The needle inserts dental filling into the root canal |
3 |
Box |
This is a dental tool to bring tooth welding into the marrow with stainless steel hilt
Number 35 long 21mm
Quality standard: ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
Box of 4 pieces |
Medical supplies, chemicals for teeth |
|
95 |
Dental cement |
3 |
Tube |
A coincidental hybrid composite used in tooth fillings.
Using directly restoring the sinuses of Type I II II II IV V The teeth of the molars.
Materials can be polished to high gloss
Quality standard: ISO 13485: 2016 |
Minh Hoa District General Hospital |
1 4g bag |
Medical supplies, chemicals for teeth |
|
96 |
Dental cement |
10 |
Tube |
Coincidental liquid composite, high radiation (210%A1) with high viscosity quality: ISO 13485: 2016 or equivalent |
Minh Hoa District General Hospital |
1 2g bag |
Medical supplies, chemicals for teeth |
|
97 |
Dental clutch |
480 |
Female |
Materials sealed with the bone marrow. Used for cleaning, shaping, size 30, 35 |
Minh Hoa District General Hospital |
Box of 120 pieces |
Medical supplies, chemicals for teeth |
|
98 |
The enzyme activity soaked solution |
20 |
Bottle |
The solution soaked in the enzyme activity, quickly effective after 1 minute.
- Neutral pH does not cause corrosion of tools.
- Meet ISO: 13485 or equivalent
Origin: Europe or G7 |
Minh Hoa District General Hospital |
1 liter bottle |
Disinfectant and other chemicals |
|
99 |
High level disinfectant solution |
60 |
can. can |
High level disinfectant solution, composition of ortho -phthaladehyde 0.55%, pH 7.2 - 7.8
- The time for high -level disinfection for tools is 5 minutes, reusable within 14 days. The storage time of solution in Can is 75 days from the time of opening. Close the Can 3.78 liters.
Meet the standards: ISO 13485 or equivalent
Origin: Europe or G7 |
Minh Hoa District General Hospital |
Can 3.78 liters. (4 can) |
Disinfectant and other chemicals |
|
100 |
Ultrasonic Gel |
100 |
Liter |
Gel suitable for ultrasound frequency in use, suitable for electrolyte electrodes, brain electrical. Can 5 liters
Quality standard ISO 13485 or equivalent |
Minh Hoa District General Hospital |
5 liter can |
Disinfectant and other chemicals |
|
101 |
CLORAMIN BENEFITS |
250 |
kg |
The content of chlorine operates: 25-27%.
Quality standard ISO 13485 or equivalent |
Minh Hoa District General Hospital |
25kg box |
Disinfectant and other chemicals |
|
102 |
Soda lime used in operating room |
40 |
Box |
High performance, maximum safety. Do not produce oxide carbon or compound A, making litholyme a safe CO2 absorption agent for use according to the standard or low-flow anesthesia.
Quality standard: ISO 13485 or equivalent |
Minh Hoa District General Hospital |
1Kg box |
Disinfectant and other chemicals |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
[VIDEO] Guide for Bid Solicitors to Extend the Prequalification Document Submission Date for PPP Projects
Similar goods purchased by Investor Bệnh viện đa khoa huyện Minh Hóa:
No similar goods purchased by the %s were found.
Similar goods purchased by other Investor excluding Bệnh viện đa khoa huyện Minh Hóa:
No similar goods have been found that other %s have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.