Request quotation of goods

Find: 10:09 25/08/2026

Bid info

Project name/purchase estimate
Purchase of medical supplies – Reagents for laboratory testing to support the healthcare operations of the 4th General Hospital in Lao Cai province (2026-2027)
Bid name
Purchase of medical supplies – Reagents for laboratory testing to support the healthcare operations of the 4th General Hospital in Lao Cai province (2026-2027)

Basic information of the request for quotation

Request for quotation code
RQ2600035166-00
Status
Posted
Name of request for quotation
Request quotation of goods
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
Group 1, Phường Sa Pa, Province Lào Cai
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Lê ThịThanh Thảo
Position
Deputy Head of Department of TCHC-TCKT
Phone number
Address
General Hospital No. 4 of Lao Cai province, Sa Pa Ward, Lao Cai province.

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 25/08/2026 10:08 To date 10/09/2026 16:30
Validity period of quotation
90 Day kể từ ngày 10/09/2026 16:30
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
Solution for cleaning and maintaining biochemical testing machines
30
Can
Used for cleaning and transporting reaction particles, supporting illumination. Ingredients: Sodium Hydroxide, Surfactant. Product origin is from G7 countries. Quality standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
1.8L
2
Pumps for testing machines
2
Pieces
Pump lines for biochemical machines Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
3
Light bulb for biochemical testing machine
4
Pieces
Technical Specifications: Rated Voltage: 12.0 V, Rated Power: 20.00 W, Diameter: 9.5 mm, Length: 30.0 mm, Light Head Length (LCL): 19.5 mm, Filament Length: 1.90 mm, Illumination Area: 1.9*2.0 mm², Filament Diameter: 2.0 mm, Lifespan: 3000 hours, Minimum Lamp Housing Diameter: 9 mm, ISO 13485:2016 Quality Standard
General Hospital No. 4 Lao Cai Province
Pieces
4
Water filter core number 1
30
Female
Water filter core number 1
General Hospital No. 4 Lao Cai Province
Female
5
Water filter cartridge #2
6
Female
Water filter core number 2
General Hospital No. 4 Lao Cai Province
Female
6
Water filter core number 3
4
Female
Water filter core number 3
General Hospital No. 4 Lao Cai Province
Female
7
RO filter column
6
Female
RO filter column
General Hospital No. 4 Lao Cai Province
Female
8
Glucose quantitative test reagent
15
Box
Method: GOD-PAP (Glucose oxidase/ peroxidase) Measurement range: 0.36 – 963 mg/dl Detection limit: 2 mg/dl Main ingredients: Phosphate buffer, pH 7.5: 0.1 mol/l Phenol: 7.5 mmol/l GOD: 12000 U/l POD: 660 U/l 4-Amino-antipyrine: 0.40 mmol/l Standard substance: Glucose: 100 mg/dl Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
6x66ml
9
Urea quantitative testing reagent
15
Box
Method: UV kinetic Measuring range/Reporting range: 4.8 - 400 mg/dl Main ingredients: R1: TRIS buffer pH 7.8: 50 mmol/l GLDH ≥ 0.80 U/l Urease ≥ 12 U/ml R2: TRIS* buffer pH 9.6: 100 mmol/l 2-oxoglutarate 8.3 mmol/l NADH ≥ 0.23 mmol/l Standard: Urea Standard (cat. no.: 823S): 50 mg/dl Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 4x66ml R2: 4x16ml
10
Creatinine quantitative testing reagent
15
Box
Method: Jaffe Measurement range: Serum/plasma: 1.0 - 2500 µmol/I Detection limit: 0.1mg/dl (8.8 µmol/l) Main ingredients: R1: Sodium hydroxide 0.2 mol/L R2: Picric acid 25 mmol/L Creatinine Standard: 2 mg/dL Product originating from G7 countries ISO quality standards 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 4x66ml R2: 4x16ml
11
GOT test reagent (AST)
12
Box
Method: IFCC Measuring range: 3 - 1000 U/L Detection limit: 1.5 U/l Main ingredients: R1: Tris buffer pH 7.8: 100 mmol/l L-Aspartate: 200 mmol/l MDH ≥ 1 KU/l LDH ≥ 2 KU/l R2: NADH ≥ 1.5 mmol/l 2-Oxoglutarate: 12 mmol/l Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 6x66ml R2: 6x16ml
12
GPT test reagent (ALT)
12
Box
Method: IFCC Measurement range: 1.7 - 900 U/L Detection limit: 4 U/l or 0.07 µkat/l Main ingredients: R1: Tris buffer pH 7.4: 100 mmol/l L-Alanine 500 mmol/l LDH 1200 U/l R2: NADH2: 0.18 mmol/l 2-Oxoglutarate: 15 mmol/l Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 6x66ml R2: 6x16ml
13
Albumin quantitative testing reagent
6
Box
Measurement method: BCG- Bromocresol green Measurement range: 10g/l–80g/l Analytical sensitivity (lower detection limit): 0.2 g/dl Main ingredients: Succinate buffer, pH 4.1: 75 mmol/l Bromcresol green 0.15 mmol/l Brij 35: 7 ml/l Detergents and stabilizers >0.1 % Standard substance (cat. no.: 963S): Bovine albumin concentration corresponding to CRM 470 (IFCC) 4.0 g/dl RPPHS 91/0619 4.0 g/dl SRM 927a (NIST) 4.5 g/dl Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
6x65ml
14
Total Protein testing reagent
6
Box
Method: Biuret Measuring range: 0 - 15 g/dl Detection limit: 0.2 g/dl or 2.0 g/l Main ingredients: Potassium iodide 30 mmol/l Potassium sodium tartrate 32 mmol/l Copper sulphate 18 mmol/l Sodium hydroxide 200 mmol/l Standard substance: Protein Total Standard (cat. no.: 950S) 100 mg/dl Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
5x66ml
15
Triglyceride quantitative testing reagent
6
Box
Method: GPO-PAP (Glycerol phosphate oxidase/peroxidase) Measuring range: 0 - 1400 mg/dL Detection limit: 0.5 mg/dl (0.05 mmol/l) Main ingredients: Pipes buffer pH 7.0: 50 mmol/l p-Chlorophenol: 2 mmol/l Lipoprotein lipase: 150000 U/l Glycerolkinase: 800 U/l Glycerol - 3 - P- oxidase: 4000 U/l Peroxidase: 440 U/l 4-Aminoantipyrine: 0.7mmol/l ATP: 0.3mmol/l Mg2+: 40 mmol/l Na-cholate: 0.20 mmol/l Potassium-Hexacyanoferrate(II): 1µmol/l Standard: Triglycerides Standard (cat. No.: 208S): 200 mg/dl Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
6x65ml
16
Cholesterol test reagent
6
Box
Method: ChOD-PAP (Cholesterol oxidase/peoxidase) Range: 1.8 – 750mg/dL Detection limit: 3 mg/dl (0.08 mmol/l) Main ingredients: Pipes buffer, pH 6.9: 90 mmol/l Phenol: 26 mmol/l Cholesterol oxidase: 200 U/l Cholesterol esterase: 300 U/l Peroxidase 1250 U/l 4-Aminoantipyrine 0.4 mmol/l Standard substance: Cholesterol Standard 200 mg/dl (5.17mmol/l) Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
6x65ml
17
HDL cholesterol quantitative testing reagent
4
Box
Method: Direct method R1: Ascorbate Oxidase ≥1.0U/mL Complex <2% TODB ≥0.5mmol/L R2: Cholesterol esterase ≥1.0 U/mL Cholesterol oxidase ≥1.0 U/mL Peroxidase ≥1.0U/mL 4-aminoantipyrine ≥1.0mmol/L Product originated in Vietnam G7 countries ISO 13485:2016 quality standard
General Hospital No. 4 Lao Cai Province
R1: 3x50ml R2: 2x25ml
18
HDL cholesterol quantitative testing standard
2
Jar
HDL Cholesterol quantitative test calibrator Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
1ml
19
HDL quantitative assay control material
6
Jar
Quality control materials for quantitative HDL Cholesterol testing Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
1ml
20
LDL Cholesterol LDL test
8
Box
Method: Direct (Direct Method) Measuring range: 0.4 - 697mg/dL Sensitivity: 1.0 mmol/L Main ingredients: R1: Cholesterol esterase ≥0.5 KU/L Cholesterol oxidase ≥0.5 KU/L Peroxidase ≥0.5 KU/L Surfactant ≥0.05% 4-aminoantipyrine ≥0.5 mmol/L R2: Chromogenic element ≥0.5 mmol/L Surfactant ≥0.05% Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 3x50ml R2: 2x25ml
21
Materials for quality control of LDL Cholesterol quantitative testing
6
Jar
Quality control materials for quantitative LDL Cholesterol testing Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
1ml
22
LDL Cholesterol LDL quantitative testing
2
Jar
Test standard for quantitative LDL Cholesterol Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
1ml
23
Test reagent diagnosed with uric acid
6
Box
Method: Uricase-PAP Measurement range: 0-30 mg/dl Detection limit: 0.2 mg/dl (11.9 µmol/l) Main ingredients: Phosphate buffer pH 8.0: 50 mmol/l DHBSA: 4 mmol/l Uricase: 60 U/l POD: 660 U/l 4-Aminoantipyrine: 1 mmol/l Preservative Uric acid Standard (cat. no.: 499S): 6 mg/dl (356.9 μmol/l) Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
4x65ml
24
Α-amylase testing reagent
6
Box
Method: CNP-G3 Principle of testing: Testing color using 2-chloro-4-nitrophenyl-αD-maltotrioside (CNP-G3) as the direct substrate. Measurement range: 0-2300 U/L Detection limit: 7 U/L or 0.12 µkat/L Main components: MES buffer, pH 6.2: 100 mmol/l NaCl: 350 mmol/l Calcium acetate: 6 mmol/l Potassium thiocyanate: 900 mmol/l CNP-G3: 2.27 mmol/l Stabilizers and detergents > 0.1 % Product origin: G7 countries ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
3x60ml
25
Gamma-GT test reagent
5
Box
Method: enzymatic color test Measurement range: Serum/plasma 0.3 - 1300 U/l Detection limit: 5 mg/dl (0.83 mmol/l) Main ingredients: R1: Tris Glycylglycin buffer pH 8.1: 100 mmol/l, Stabilizer and Detergent R2: L-γ-Glutamyl-3-carboxy-4-nitroanilide 2.9 mmol/l, Stabilizer and Detergent Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 2x66ml R2: 2x16ml
26
Creatine kinase quantitative test in serum.
6
Box
Method: IFCC Measuring range: 1.5 - 2100 U/l Analytical sensitivity: 2 U/l (0.03 µkat/l) Main ingredients: R1: Imidazole pH 6.6: 60 mmol/L Glucose: 27 mmol/L N-Acetylcysteine (NAC): 27 mmol/L Magnesium acetate: 14 mmol/L EDTA: 2 mmol/L NADP: 2.7 mmol/L G6P-DH: 1500 U/I Hexokinase (HK) ≥ 5 kU/L R2: Imidazole pH 9.3: 160 mmol/L ADP: 11 mmol/L AMP: 28 mmol/L G6P-DH: ≥ 14 kU/L Diadenosine pentaphosphate: 55 μmol/L EDTA-Na2: 2 mmol/L Creatine phosphate: 160mmol/L Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 2x60ml R2: 2x15ml
27
Creatine Kinase-MB (CK-MB) testing reagent
6
Box
Method: Immunoinhibition Measuring range: 0.2-2400 U/l Main ingredients: R1: Imidazole buffer pH 6.0: 100 mmol/l Creatine phosphate: 30 mmol/l Glucose: 20 mmol/l N-Acetylcysteine (NAC): 20 mmol/l MgAC: 10 mmol/l EDTA: 2 mmol/l ADP: 2 mmol/l AMP: 5 mmol/l Diadenosine pentaphosphate: 10 μmol/L G6PDH: ≥1.5 KU/L HK: ≥2.5 KU/L R2: NADP: 2 mmol/l Anti-M subunit polyclonal antibody: ≥ 2KU/L Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 2x67ml R2: 2x17ml
28
Creatine Kinase-MB Quantitative Assay Control Material
4
Box
Creatine Kinase-MB quantitative test control material Main ingredients: Human serum. Standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
2x2ml
29
Creatine Kinase-MB quantitative assay calibrator
2
Jar
Creatine Kinase-MB quantitative test calibrator Main ingredient: human serum Standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
2ml
30
Biochemical testing materials for biochemical testing level 1
15
Jar
Lyophilized control material based on human plasma, defibrin for measuring the following indicators: Albumin, Alkaline Phosphatase, ALT (GPT), Pancreatic Amylase, Amylase Total, AST (GOT), Bicarbonate, Bile Acids, Bilirubin Direct, Bilirubin Total, Calcium, Ionised Calcium, Chloride, Cholesterol, Cholinesterase, CK Total, Copper, Creatinine, gamma-GT, GLDH, Glucose, Iron, Lactate, LD (LDH), Lipase, Lithium, Magnesium, Inorganic Phosphate, Potassium, Protein Total, Sodium, TIBC, Triglycerides, Urea, Uric Acid (Urate), Zinc. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
5ml
31
Biochemical testing materials level 2
15
Jar
Lyophilized control material based on human plasma, defibrin for measuring the following indicators: Albumin, Alkaline Phosphatase, ALT (GPT), Pancreatic Amylase, Amylase Total, AST (GOT), Bicarbonate, Bile Acids, Bilirubin Direct, Bilirubin Total, Calcium, Ionised Calcium, Chloride, Cholesterol, Cholinesterase, CK Total, Copper, Creatinine, gamma-GT, GLDH, Glucose, Iron, Lactate, LD (LDH), Lipase, Lithium, Magnesium, Inorganic Phosphate, Potassium, Protein Total, Sodium, TIBC, Triglycerides, Urea, Uric Acid (Urate), Zinc. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
5ml
32
Calibration quality testing for biochemical testing
10
Jar
Lyophilized serum calibrators are derived from human serum. Multicalibrator can be used to calibrate biochemical analyzers: Albumin, Alkaline Phosphatase, ALT (GPT), Amylase Pancreatic, Amylase Total, AST (GOT), Bilirubin Direct, Bilirubin Total, Calcium, Chloride, Cholesterol, Cholinesterase, CK Total, Copper, Creatinine, Gamma GT, Glucose, Iron, Lactate, LD (LDH), Lipase, Magnesium, Inorganic Phosphate, Potassium, Protein Total, Sodium, Triglycerides, Urea, Uric Acid (Urate), Zinc. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
5ml
33
Bilirubin Total test reagent
6
Box
Method: DCA Measurement range: maximum 30 mg/dl Lower detection limit is 0.07 mg/dL. Main ingredients: R1: Phosphate buffer 50 mmol/L NaCl 150 mmol/L R2: 2.4-Dichlorophenyl-diazonium salt 5 mmol/L HCl 130 mmol/L Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 3x65ml R2: 3x14ml
34
Bilirubin Direct test reagent
6
Box
DCA method Wavelength 546 nm (540 – 560 nm) Light path 1 cm Measurement range from 0.05-23mg/dl Detection limit below 0.1 mg/dL. Main ingredients: R1: EDTA-Na2 0.1 mmol/L NaCl 150 mmol/L Sulfamic acid 100 mmol/L R2: 2.4-Dichlorophenyl-diazonium salt 0.5 mmol/L HCl 900 mmol/L EDTA-Na2 0.13 mmol/L Product originated in G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 3x50ml R2: 3x10ml
35
Iron test reagent
5
Box
Method: Ferene Measuring range: 5-1000 μg/dL (0.9 - 179 μmol/L). The lowest detection limit is 5 μg/dL (0.9 μmol/L). Main ingredients: R1: Acetate buffer pH 4.5: 1 mol/L Thiourea: 120 mmol/L R2: Ascorbic acid: 240 mmol/L Ferene: 3 mmol/L Thiourea: 120 mmol/L Standard: Iron Standard (cat. no.: 705S): 167 μg/dL Product originating from G7 countries ISO quality standards 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 3x67ml R2: 3x16ml
36
Reactive protein quantitative test (CRP)
40
Box
Measuring range: 0-50mg/dl Main ingredients: R1: Latex Glycine buffer (pH 8.42) Rabbit anti-human CRP sensitized latex (0.20%). Sodium azide (0.95 g/L) R2: Buffer Sodium chloride (9 g/L) Detergent (0.1 %) Sodium azide (0.95 g/L) Product originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 2x25ml R2: 2x5ml
37
Calibration of quantitative test C - Reactive Protein (CRP)
5
Box
C-reactive protein (CRP) quantitative test calibrator Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
5x1ml
38
Quality control materials for quantitative test C - Reactive Protein (CRP) Low
10
Box
Quality control materials for testing low levels of C - reactive protein (CRP). Main ingredients: Diluent of human plasma and CRP-containing pleural fluid with phosphate-buffered saline. Preservative 0.095% sodium azide. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
1ml
39
Quality control materials for quantitative test C - Reactive Protein (CRP) high level
10
Box
Quality control materials for high-level C - reactive protein (CRP) testing. Main ingredients: Diluent of human plasma and CRP-containing pleural fluid with phosphate-buffered saline. Preservative 0.095% sodium azide. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
1ml
40
Rheumatoid Factor (RF) Quantitative Test Reagent
5
Box
Method: Immunoturbidimetric This method exhibits linearity up to 120 IU/mL. Range of measurement: 10 - 120 IU/mL. Main components: Reagent 1: Tris buffer ≤25 mmol/l, Sodium azide pH 8.2 ≤ 0.999g/l, Reagent 2: Latex particles coated with human gamma-globulin, sodium azide <0.99 g/L. Wavelength: 600 nm. Sample: Human serum. Product origin from G7 countries. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 1 x 25 ml bottle R2: 1 x 5 ml bottle
41
Rheumatoid Factor quantitative test standard (RF)
2
Box
Reference standard for quantifying Rheumatoid Factor (RF). The product originates from G7 countries and meets the quality standards of ISO 13485:2016.
General Hospital No. 4 Lao Cai Province
5x1ml
42
Quality control materials Rheumatoid Factor (RF)
3
Box
Materials for quality control of quantitative rheumatoid factor (RF) testing. Products originate from G7 countries. Standards: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
2x3ml
43
Alcohol Ethanol quantitative testing reagent
20
Box
Measurement range: 0-5g/L; Main wavelength: 340nm; Secondary wavelength: 410nm. Main components: R1: Buffer, pH 8.3, 300 mmol/L NAD+, 10 mmol/L R2: Alcohol dehydrogenase (ADH)³ 200 kU/L. Product origin: G7 countries. Quality standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
R1: 1x60ml R2: 1x20ml
44
ALCOHOL Ethanol Quantitative Testing
5
Box
Reference standard for quantitative alcohol/ethanol testing; Products originating from G7 countries; Quality standard ISO 13485:2016.
General Hospital No. 4 Lao Cai Province
1ml
45
Quality control material for quantitative test of alcohol ethanol
10
Box
Materials for quality control of quantitative alcohol/ethanol testing; Products originating from G7 countries; ISO 13485:2016 quality standards.
General Hospital No. 4 Lao Cai Province
2x1ml
46
Reaction for biochemical testing machines
10
Bag
Specimen container Material: PS plastic Size: 16*38mm Capacity: 2-4ml Color: Transparent Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
500 pieces/ bag
47
Centrifugal tube
5
Bag
Centrifuge tube, small capacity 1.5ml, graduated, conical bottom. Acceleration force (RCF): 30000 x grams Autoclavable Material polypropolyne USP VI Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
500 pieces/ bag
48
Unfiltered gold tip 200µl
15
Bag
Gold -headed
General Hospital No. 4 Lao Cai Province
1000 pieces/bag
49
Green conical tip without filter 1000µl
15
Bag
Blue taper head sucks sample
General Hospital No. 4 Lao Cai Province
500 pcs/ bag
50
The quantitative test of electrolytes (k, na, cl, ca, pH)
25
Box
- Main ingredients: KCl, NaCl, NaAc, CaCl2, pH buffer, surfactant, preservative. - Calibration values: Calibration A: K+ 4 mmol/L, Na+ 140 mmol/L, Cl- 100 mmol/L, Ca2+ 1.25 mmol/L, pH 7.4 Calibration B: K+ 8 mmol/L, Na+ 110 mmol/L, Cl- 70 mmol/L, Ca2+ 2.5 mmol/L, pH 7 - Concentration: Ammonium molybdate 0.4 mmol/l Sulfuric acid 100 mmol/l Hydrochloric acid 100 mmol/l - Sample: Human serum - Linear correlation coefficient r: K+ ≥0.99, Na+≥0.99, Cl- ≥0.99, Ca2+ ≥0.99 - Linear deviation D: K+ ≤3%, Na ≤1%, Cl- ≤2%, Ca2+ ≤5% - Sensitivity of analysis K+ ≤0.2mmol/L, Na+≤6.7mmol/L, Cl- ≤6.2mmol/L, Ca2+ ≤0.1mmol/L - Accuracy bias: K+ ≤2%, Na+ ≤1.5%, Cl- ≤2%, Ca2+ ≤5%, pH ≤ 1% Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Cal A: 650ml Cal B: 200ml
51
Quantitative testing quality control materials (K, Na, Cl, Ca, pH)
2
Box
- Main ingredients: KCl, NaCl, NaAc, CaCl2, LiCl, pH buffer, surfactant, preservative. - Performance characteristics: + Within CV range: K+ ≤1.5%, Na+ ≤1.5%, Cl- ≤1.5%, Ca++ ≤1.5%, pH ≤1.0% + Between CV range: K+ ≤3.0%, Na+ ≤3.0%, Cl- ≤3.0%, Ca++ ≤5.0%, pH ≤1.0% + Accuracy bias: K+ ≤2.0%, Na+ ≤1.5%, Cl- ≤3.0%, Ca++ ≤5.0%, pH ≤1.0% Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
10x1ml
52
IVD is a cleaning solution used for electrolyte testing machines
4
Box
Main ingredients: Sodium Hypochlorite (NaClo) 0.4% - 0.5% Products originating from countries G7 quality standard ISO 13485: 2016
General Hospital No. 4 Lao Cai Province
10x5ml
53
IVD is a cleaning solution used for electrolyte testing machines
4
Box
Main ingredients: enzyme: pepsin. Dilutor: KCl, NaCl, Hydrochloride Acid. Products originating from countries G7 quality standard ISO 13485: 2016
General Hospital No. 4 Lao Cai Province
3x2ml
54
K+ quantitative testing electrode (potassium)
1
Pieces
K electrode Compatible with Auto ISE500 model electrolyte analyzer Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
55
Na+ quantitative testing electrode (sodium)
1
Pieces
Na electrode Compatible with Auto ISE500 model electrolyte analyzer Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
56
Cl- (Chlorine) quantitative testing electrode
1
Pieces
Cl electrode Compatible with Auto ISE500 model electrolyte analyzer Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
57
Electrode for quantitative testing of Ca++ (Calci)
1
Pieces
Ca electrode Compatible with Auto ISE500 model electrolyte analyzer Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
58
PH quantitative testing electrode
1
Pieces
pH electrode Compatible with Auto ISE500 model electrolyte analyzer Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
59
Reference quantitative testing
1
Pieces
Ref electrode Compatible with Auto ISE500 model electrolyte analyzer Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
60
Pumps for testing machines
2
Pieces
Tubing pump pump line Compatible with Auto ISE500 model electrolyte analyzer Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
Pieces
61
IVD is Na/K/Cl/Ca/pH electrode charging solution
1
Box
Main ingredients: KCl, NaCl, NaAC, CaCl2, LiCl, pH cushion, surfactants, preservatives. Partial concentrations: K+ 5mmol/l, Na+ 125mmol/l, Cl-145mmol/l, Ca2+ 10mmol/l, pH 7.6 Products originating in countries G7 quality standard ISO 13485: 2016
General Hospital No. 4 Lao Cai Province
5x0.8ml
62
IVD is the reference electrode loading solution
1
Jar
Main ingredients: KCl concentration: K+ 4mol/l, Cl-4mol/l products originating from countries G7 quality standard ISO 13485: 2016
General Hospital No. 4 Lao Cai Province
20ml
63
Reagents for quantitative testing of pH, pCO2, pO2, Hct
6
Box
Chemicals used for blood gas analysis, measuring the following parameters: pH, pO2, pCO2, Hct. The cartridge contains: 3 pouches of control solutions, 1 pouch of reference solution and a waste container, sensor card, distributor valve, pump tube, and sample collection device, all packaged in one unit. It also includes an intelligent Quality Management Program (IQM). Compatible with the GEM 3500 blood gas analyzer. Chemicals do not require refrigeration. Packaged: 150 tests/box
General Hospital No. 4 Lao Cai Province
64
Reagents for quantitative testing of 9 electrolyte parameters, blood gases and metabolism
12
Box
Blood gas analysis, including the measurement of: pH, pCO2, pO2, Na+, K+, Ca++, Glucose, Lactate, and Hct. The cartridge contains: 3 pouches of control solutions, 1 pouch of reference solution, and a waste container, sensor card, distributor valve, pump tube, and sample collection device, all packaged in one unit. It also includes an intelligent Quality Management System (IQM) – a continuous, automated, real-time quality assurance system. Compatible with the GEM 3500 blood gas analyzer. Reagents do not require refrigeration. 75 samples per box.
General Hospital No. 4 Lao Cai Province
65
Materials for controlling electrolyte and blood gas tests
1
Box
Contril 9 Multipack: 1 pack containing 10 vials of 2 ml each, with three different concentrations: 1 x 2 ml, 2 x 2 ml, and 3 x 2 ml.
General Hospital No. 4 Lao Cai Province
66
Materials used for testing machines
10.000
Pieces
Specimen containers Size: 6mm x 25mm Capacity: 500µl Color: Transparent Material: PS (Polystyrene) Origin: Countries within the G7 Quality standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
2000 pcs/bag
67
PT quantitative test reagent
8
Box
Prothrombin time (PTR) = clotting time of test plasma / clotting time of control plasma. Expected values: PTR: 1.0 ± 0.15; INR: 0.8-1.24 Main ingredients: 1.4% calcium chloride, 0.1% Sodium benzoate, 2.5% aminoacetic acid, 0.15% sodium chloride, 2.5% rabbit brain powder Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
10x5ml
68
APTT quantitative test reagent
8
Box
Performance: Repeatability: The coefficient of variation (CV) of repeat test results with control plasma samples should not exceed 5% Main ingredients: R1: 0.05% Ellagic acid, 0.2% cephalin, 0.2% sodium chloride, 0.1% Sodium benzoate R2: 0.3% calcium chloride, 0.1% Sodium benzoate Product originated in G7 countries ISO quality standards 13485:2016
General Hospital No. 4 Lao Cai Province
5x5ml + CaCl2: 5x5ml
69
TT quantitative test reagent
8
Box
Reference range for normal index: 8-14 seconds Main ingredients: 1% thrombin, 0.1% Sodium benzoate, 0.1% Tris, 1% aminoacetic acid, 1.3% sodium chloride Product originated in G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
10x5ml
70
Fibrinogen quantitative testing reagent
8
Box
Fibrinogen reference value: 2.0-4.0 g/L Expected value: Clauss method Fibrinogen (mg/dL) 150 - 400 Main ingredients: R1: 1% thrombin, 0.1% Sodium benzoate, 1% aminoacetic acid, 1.3% sodium chloride, 0.05% Tris R2: 0.68% imidazole, 0.5% sodium chloride, 0.3% hydrochloric acid Products originating from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
5x5ml + Buffer: 3x30ml
71
Quality control materials for quantitative tests, APTT, TT, FIB average
5
Box
Main components: Bovine plasma, sodium citrate anticoagulant (<0.4%) The product originates from countries within the G7. Quality standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
10x1ml
72
Quality control materials for quantitative, APTT, TT, FIB high level
5
Box
Main components: Bovine plasma, sodium citrate anticoagulant (<0.4%) The product originates from countries within the G7. Quality standards: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
10x1ml
73
IVD cleans and maintains hematology analyzers
5
Jar
Main ingredients: Sodium hypochlorite < 8.0% Sodium hydrate < 2.0% Limits: Reagents must be used within the environmental temperature range of 15-35 degrees Celsius. Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
50ml
74
Chemicals for hematological analysts
15
Bin
Main ingredients: Sodium chloride < 0.9% Potassium chloride < 0.06% Buffer < 0.3% Preservative < 0.1% Has a built-in chemical management QR Code. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
20L
75
Red blood cell solution
10
Bottle
Main ingredients: Detergent < 1.5% Buffer < 2.0% Preservative < 1.5% Dye < 1.0% Has a built-in chemical management QR Code. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
1L
76
Red blood cell solution
5
Bottle
Main ingredients: Detergent < 0.5% Buffer < 0.6% Preservative < 0.7% Has a built-in chemical management QR Code. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
500ml
77
Red blood cell solution
5
Bottle
Main ingredients: Detergent < 4.0% Buffer < 1.0% Has built-in chemical management QR Code. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
500ml
78
Materials for quantitative testing of 29 hematological parameters
5
Jar
Main ingredients: Healthy mammalian blood (pig), preservative and cell stabilizer. Products originating from G7 countries with ISO 13485:2016 quality standards
General Hospital No. 4 Lao Cai Province
3ml
79
IVD cleans and maintains hematology analyzers
5
Jar
Main ingredients: Sodium hypochlorite < 8.0% Sodium hydrate < 2.0% Limits: Reagents must be used within the environmental temperature range of 15-35 degrees Celsius. Product originates from G7 countries Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
50ml
80
Thermal paper
100
Roll
Size: 57mm x 30m x 12mm
General Hospital No. 4 Lao Cai Province
10 rolls/ box
81
Urine test strip 11 parameters
15.000
kiểm TRA
Suitable for use with the Reactif Touch Plus urine testing device – Meets ISO 13485 quality standards.
General Hospital No. 4 Lao Cai Province
100 Test/ Box
82
Test tray for qualitative IgM antibody testing against hepatitis A virus (HAV)
300
kiểm TRA
Test tray for qualitative IgM antibody testing against hepatitis A virus (HAV) Sample: Serum, plasma, whole blood Relative sensitivity: 95.7% Relative specificity: 99.1% Accuracy: 98.6% Standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
25 Test/ Box
83
AMP/MOP/COD/Heroin qualitative test strip
5.000
kiểm TRA
- Lateral flow chromatography immunoassay to qualitatively detect a variety of drugs, drug metabolites and alcohol at the following threshold concentrations in urine: MOP 300ng/ml; AMP 500ng/ml; THC 50ng/ml; COD 300ng/ml; HER 10ng/ml. - Ingredients: Contains mouse monoclonal antibody binding particles and corresponding protein-drug conjugates. A goat antibody was used in each control line. - Sensitivity: 100% - Specificity: 100% - Accuracy: AMP: 99.925%; COD: 99.9%; THC: 99.92%; MOP: 99.93%; 6-MAM (Heroin): 99.9% - Cross-reactivity: Does not cross-react with compounds at a concentration of 100µg/ml: Acetophenetidine, N-Acetylprocainamide, Acetylsalicylic acid.... Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
25 Test/Box
84
Sterilized cotton swabs, wooden sticks
20
Bag
- The tube and lid are made of plastic, the rod is made of wood, and the cotton swab has a length of approximately 175mm. Each item is individually packaged and sterilized using EO gas or equivalent. - Used for collecting, storing, and transporting samples. Widely used in dentistry, dermatology, gynecology, urology, and other medical laboratories.
General Hospital No. 4 Lao Cai Province
100 pieces/bag
85
Microscopy, transparent
10
Box
- Dimensions: 25.4 x 76.2 mm, thickness: 1.0-1.2 mm, transparent, flat surface, free of defects.
General Hospital No. 4 Lao Cai Province
72 pieces per box
86
T has a lid for urine analyzing
1.500
Female
Urine test tube Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
87
Javen solution
1
Can
NaCLO (sodium chloroisocyanurate) – Javen is used as a bleaching agent for textile products and can be used for disinfecting water in household use, cleaning, and sanitation purposes in homes, hospitals, and restrooms.
General Hospital No. 4 Lao Cai Province
Can 30 liters
88
Dyeing solution
3
Set
The Gram staining kit is used for performing the Gram stain procedure. It includes a minimum of four solutions: 250 ml bottles of Crystal Violet, Lugol's iodine, Decolor (alcohol-acetone), and Safranin.
General Hospital No. 4 Lao Cai Province
Set 4 bottles 250ml
89
Dyeing solution
3
Set
The Ziehl-Neelsen staining kit is used for staining and microscopic examination. It includes a minimum of three components: 250 ml bottles of Carbolfuchsin, concentrated acid alcohol (hydrochloric acid in ethanol), and methylene blue, each 250 ml.
General Hospital No. 4 Lao Cai Province
Set of 3 bottles 250ml
90
Mucus
500
Pieces
The bottle body dimensions are 36x60mm (maximum capacity of 60ml), and the body and lid fit together perfectly.
General Hospital No. 4 Lao Cai Province
100 pieces/bag
91
Antigen assessment test A
20
Jar
Reagent for qualitative A antigen testing, clone: ​​(9113D10) Hemagglutination principle Main ingredients: 0.001% Anti-A monoclonal, 0.02% Na2HPO4, 0.5%BSA, 0.03% NaCl, 0.2% EDTA, Blue color Stain (≤ 0.1 ml/L) ISO standard 13485:2016
General Hospital No. 4 Lao Cai Province
10ml
92
Reagents for qualitative testing of antigen A and antigen B
20
Jar
Reagents for qualitative testing of antigen A, antigen B, clone: ​​(152D12 + 9113D10) Principle of hemagglutination Main ingredients: 0.001% Anti-AB monoclonal, 0.02% Na2HPO4, 0.5%BSA, 0.03% NaCl, 0.2% EDTA Standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
10ml
93
Antigen -intimidating testing reagent b
20
Jar
Reagent for qualitative B antigen testing, clone: ​​(9621A8) Hemagglutination principle Main ingredients: 0.001% Anti-B monoclonal, 0.02% Na2HPO4, 0.5%BSA, 0.03% NaCl, 0.2% EDTA, Yellow color Stain (≤ 0.09 ml/L) ISO standard 13485:2016
General Hospital No. 4 Lao Cai Province
10ml
94
Antigen assessment test D
20
Jar
Qualitative D antigen test reagent, clone: (P3X61 + P3X21223B10 + P3X290 + P3X35) Hemagglutination principle Main ingredients: 0.001% Anti-D IgG/IgM Blend, 0.02% Na2HPO4, 0.5%BSA, 0.03% NaCl, 0.2% EDTA ISO standards 13485:2016
General Hospital No. 4 Lao Cai Province
10ml
95
PS plastic test tube without lid
2.000
Female
Plastic test tubes, without lids
General Hospital No. 4 Lao Cai Province
500 pieces/bag
96
Thyroglobulin anti -antibody testing reagent
5
Box
Main components: Conjugated enzyme: Peroxidase-labeled human IgG antibody, in a Tris-NaCl buffer containing bovine serum albumin. Contains various preservatives. Quality standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
97
Troponin I (CTNI) card quantitative test test (CTNI)
10
Box
Main ingredient: Enzyme conjugate. Horseradish-peroxidase labeled anti-cTnI mouse monoclonal antibody in Tris buffer containing BSA. Contains a selection of preservatives. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
98
Ferritin quantitative testing reagent
10
Box
Main ingredient: Conjugated enzyme. HRP (horseradish peroxidase) labeled antiferritin mouse monoclonal antibody in Tris-NaCl buffer containing BSA (bovine serum albumin) and casein. Contains some preservatives. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
99
Free triiodyronine quantitative testing reagent
10
Box
Main ingredient: Conjugated enzyme. Anti-T3 was labeled with horseradish peroxidase in BIS-Tris-Propane-NaCl buffer containing BSA (bovine serum albumin). Contains preservatives ProClin® 300 and Bronidox. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
100
Free quantitative test reagent thyroxine
10
Box
Main ingredient: Conjugated enzyme. Anti-T4-labeled horseradish-peroxidase in Tris-NaCl buffer containing BSA (bovine serum albumin). Contains some preservatives. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
101
Insulin quantitative testing reagent
10
Box
Main components: Conjugated enzyme. Mouse monoclonal IgG antibody, labeled with horse radish peroxidase (HRP), in a Tris-HCl buffer containing bovine serum albumin. Contains preservatives. Quality standard: ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
102
PCT (Procalcitonin)
5
Box
Main ingredient: Conjugated enzyme. Mouse HRP (horseradish peroxidase)-labeled PCT monoclonal antibody in Tris-NaCl buffer containing BSA. Contains a selection of preservatives. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
103
Testing test quantitative hormone stimulates thyroid gland
10
Box
Key components: + Conjugated enzyme: Horseradish peroxidase (HRP) labeled with anti-TSH antibody, in a Tris-NaCl buffer containing bovine serum albumin. Contains preservatives. Meets ISO 13485:2016 quality standards and CE marking.
General Hospital No. 4 Lao Cai Province
100 test
104
Quantitative test kit β-HCG
10
Box
Key components: Enzyme Conjugate: Horseradish peroxidase-labeled, single-chain antibody derived from human IgG, suspended in a Tris buffer containing BSA with 0.006% ProClin® 300 and 0.1% Bronidox preservative. Quality standards ISO 13485:2016
General Hospital No. 4 Lao Cai Province
50 Tests * 2
105
Cortisol quantitative testing reagent
5
Box
Main ingredient: Conjugated enzyme. Contains horseradish peroxidase-labeled Cortisol antigen in MES buffer containing casein. Contains some preservatives. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
106
N-Termin Pro B-Type Sodium Peptide reagent
5
Box
Main ingredient: Conjugated enzyme. Mouse monoclonal NT-proBNP antibody was labeled with HRP (horseradish peroxidase) in Tris-NaCl buffer containing BSA (bovine serum albumin). Contains some preservatives. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
100 test
107
Chemicals used for immunoassays
5
Box
Luminescent agent Used in combination with appropriate reagent kits based on chemiluminescent microparticle immunoassay technology (CLIA Microparticles) to detect in vitro diagnostic measurements. Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
110ml×2sets
108
Chemicals used for immunoassays
10
Box
Buffer solution Main ingredient: Phosphate buffer Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
4 x 500ml bottles
109
Chemicals used for immunoassays
2
Box
Diluent solution Main ingredient: NaCl buffer Quality standard ISO 13485:2016
General Hospital No. 4 Lao Cai Province
250ml * 4 vials
110
Chemicals used for immunoassays
15
Box
Cleaning Solution - Purpose of Use: Concentrated solution used to clean test tubes and pipettes during analytical procedures for diagnostic testing. Main Ingredients: Standardized Sodium Hydroxide, Quality certified according to ISO 13485:2016.
General Hospital No. 4 Lao Cai Province
25ml*12 vials
111
CuVet used for immune testing machines
15
Bag
Reaction cell ISO 13485:2016 quality standard
General Hospital No. 4 Lao Cai Province
1000 PCS
112
Pumps for immune machine
1
Pieces
Tubing for medical devices – ISO 13485:2016 quality standard
General Hospital No. 4 Lao Cai Province
Pieces
113
EDTA K2 2ml of blue rubber lid, low mous
50.000
Tube
Plastic test tubes, size 13 x 75mm, with a blue-colored plastic-coated rubber cap. The contents are EDTA K2 anticoagulant for 2 ml of blood. Meets the standards of ISO 13485:2016.
General Hospital No. 4 Lao Cai Province
100 tubes/tray
114
Heparin lithium tube 2ml black, low mous
50.000
Tube
Plastic test tubes, size 13 x 75 mm, with black plastic caps. The contents are 2 ml of lithium heparin anticoagulant blood collection solution. Complies with the ISO 13485:2016 standard.
General Hospital No. 4 Lao Cai Province
100 tubes/tray
115
Large red seed serum tube
2.000
Tube
PP plastic test tubes, size Ø13 x 75 (mm) or Ø12 x 75 (mm), with red plastic caps. The inside contains PS (polystyrene) granules, and volume markings are printed on the tube label. Complies with ISO 13485: 2016 standard.
General Hospital No. 4 Lao Cai Province
500 tubes/bags
116
Citrate test tube 3.8% 2ml of green lid, low mous
8.000
Tube
PP plastic test tubes, size Ø13 x 75 (mm) or Ø12 x 75 (mm), with a green plastic cap. The inside contains 3.8% Trisodium Citrate Dihydrate anticoagulant, with volume markings on the tube label. Meets ISO 13485:2016 standards.
General Hospital No. 4 Lao Cai Province
100 tubes/tray
117
Chimigly tube 2ml of gray lid, low mous
2.000
Tube
PP plastic test tubes, size Ø13 x 75 (mm) or Ø12 x 75 (mm), with gray plastic caps. The inside contains sodium fluoride (NaF) and EDTA K2, with volume markings on the tube label. Meets ISO 13485: 2016 standards.
General Hospital No. 4 Lao Cai Province
100 tubes/tray
118
Plastic jar of PS 50ml HTM red lid, labeled
100
Female
Transparent PS plastic bottle, capacity 50ml, red plastic lid, label. Meets ISO 13485:2016 standard
General Hospital No. 4 Lao Cai Province
100 vials/ bag
119
Demated chemicals for hematological analysts
15
Can
Used as a diluent for hematology analyzers Physical state: liquid Color: none Odor: none pH: 7.35 to 7.55 Solubility: soluble in water Ingredients: Sodium chloride 0.44%, Sodium sulphate anhydrous 0.97% Storage temperature: 1 to 30°C Stability after opening: 60 days
General Hospital No. 4 Lao Cai Province
120
Chemicals for red blood cells for hematological analysts
5
Can
Used as a lysing agent for hematology analyzers Physical state: liquid Color: no Odor: light pH: 4 to 7 Solubility: soluble in water Ingredients: Quaternary ammonium salt 3.7% Storage temperature: 1 to 30°C Stability after opening: 90 days
General Hospital No. 4 Lao Cai Province
121
Wash chemicals for hematological analysts
5
Can
Used as a cleaning agent for hematology analyzers Physical state: liquid Color: green Odor: mild pH: 7.7 to 8.3 Solubility: soluble in water Ingredients: Polyoxyethylene tridecylether: 0.049% Storage temperature: 1 to 30°C Stability after opening: 180 days
General Hospital No. 4 Lao Cai Province
122
Wash chemicals for concentrated hematological analysts
5
Can
Used as a cleaning agent for hematology analyzers Physical state: liquid Color: yellow or yellow-green Odor: unpleasant (chlorine) pH: 10 to 13 Solubility: soluble in water Ingredients: Sodium hypochlorite Storage temperature: 1 to 30°C Stability after opening: 90 days
General Hospital No. 4 Lao Cai Province
123
Chemicals used for hematological analysts for normal control
3
Jar
Used for calibrating hematology analyzers: Physical state: liquid Color: dark red pH: 7.0 to 9.0 Solubility: soluble in water Composition: human red blood cells, simulated white blood cells, and animal (mamalian) platelets Storage temperature: 2 to 8°C Stability after opening: 14 days
General Hospital No. 4 Lao Cai Province
124
Chemicals used for hematological analysts for low domestic control
3
Jar
Used for calibrating hematology analyzers: Physical state: liquid Color: dark red pH: 7.0 to 9.0 Solubility: soluble in water Composition: human red blood cells, simulated white blood cells, and animal (mamalian) platelets Storage temperature: 2 to 8°C Stability after opening: 14 days
General Hospital No. 4 Lao Cai Province
125
Chemicals for hematological analysts for high levels
3
Jar
Used for calibrating hematology analyzers: Physical state: liquid Color: dark red pH: 7.0 to 9.0 Solubility: soluble in water Composition: human red blood cells, simulated white blood cells, and animal (mamalian) platelets Storage temperature: 2 to 8°C Stability after opening: 14 days
General Hospital No. 4 Lao Cai Province
126
Chemicals for hematological analysts for calibration
2
Jar
Used for calibrating hematology analyzers. Stability after opening: 7 days. Components: Human red blood cells, stimulated white blood cells, and mammalian thrombocytes. Storage temperature: 2 to 8°C. Stability after opening: 7 days.
General Hospital No. 4 Lao Cai Province
127
Filter for hematemia
2
Pieces
Density: 0.9 g/cm3 Tensile elasticity: 1400 MPa Tensile strength: 33 MPa Flexural coefficient: 1400 MPa Flexural strength: 40 MPa Deformation temperature: 85˚C
General Hospital No. 4 Lao Cai Province
128
Pump for hematemia
2
Pieces
Material type: TPE Hardness: 64 Shore A Autoclave: Yes Gamma ray sterilization: Yes Minimum temperature: -40˚C Maximum temperature: 135˚C
General Hospital No. 4 Lao Cai Province
129
Demated chemicals for hematological analysts
150
Can
Used as a diluent for hematology analyzers Physical state: liquid Color: none Odor: none pH: 7.35 to 7.55 Solubility: soluble in water Ingredients: Sodium chloride 0.44%, Sodium sulphate anhydrous 0.97% Storage temperature: 1 to 30°C Stability after opening: 60 days
General Hospital No. 4 Lao Cai Province
130
Red blood cell chemicals for hematological analysts to measure hemoglobin
30
Can
Used as a diluent for hematology analyzers Physical Properties: Liquid Color: Clear Odor: Mild pH: 7.0 to 7.6 Solubility: Soluble in water Composition: Dodecyltrimethylammonium chloride: < 3.0%, Cetrimonium chloride: < 0.1%, Citric acid monohydrate: < 2.0% Storage Temperature: 1 to 30°C Stability after opening: 90 days
General Hospital No. 4 Lao Cai Province
131
Red blood cell chemicals for hematological analysts for leukocytes
30
Can
Used as a diluent for hematology analyzers Physical properties: Liquid Color: Clear Odor: None pH: 8.0 to 8.6 Solubility: Soluble in water Composition: Sodium alkyl ether sulphate: 0.11% Storage temperature: 1 to 30°C Stability after opening: 90 days
General Hospital No. 4 Lao Cai Province
132
Wash chemicals for hematological analysts
15
Can
Used as a cleaning agent for hematology analyzers Physical properties: liquid Color: blue Odor: mild pH: 8.0 to 8.6 Solubility: soluble in water Composition: Sodium alkyl ether sulphate: 0.069% Storage temperature: 1 to 30°C Stability after opening: 90 days
General Hospital No. 4 Lao Cai Province
133
Wash chemicals for concentrated hematological analysts
4
Set
Used as a cleaning agent for hematology analyzers Physical properties: liquid Color: yellow or yellow-green Odor: unpleasant (chlorine) pH: 10 to 13 Solubility: soluble in water Composition: Sodium hypochlorite: 6.1%, Sodium hydroxide <0.5% Storage temperature: 2 to 8°C Stability after opening: Use once only
General Hospital No. 4 Lao Cai Province
134
Chemicals used for hematological analysts used for internal control
10
Jar
Used to calibrate hematology analyzers Physical state: liquid Color: dark red pH: neutral Solubility: soluble in water Ingredients: Human red blood cells, simulated white blood cells and mammalian platelets Storage temperature: 2 to 8°C Stability after opening: 14 days
General Hospital No. 4 Lao Cai Province
135
Chemicals used for hematological analysts for low domestic control
10
Jar
Used to calibrate hematology analyzers Physical state: liquid Color: dark red pH: neutral Solubility: soluble in water Ingredients: Human red blood cells, simulated white blood cells and mammalian platelets Storage temperature: 2 to 8°C Stability after opening: 14 days
General Hospital No. 4 Lao Cai Province
136
Chemicals for hematological analysts for high levels
10
Jar
Used to calibrate hematology analyzers Physical state: liquid Color: dark red pH: neutral Solubility: soluble in water Ingredients: Human red blood cells, simulated white blood cells and mammalian platelets Storage temperature: 2 to 8°C Stability after opening: 14 days
General Hospital No. 4 Lao Cai Province
137
Chemicals for hematological analysts for calibration
2
Jar
Used for calibrating hematology analyzers. Stability after opening: 7 days. Components: Human red blood cells, stimulated white blood cells, and mammalian thrombocytes. Storage temperature: 2 to 8°C. Stability after opening: 7 days.
General Hospital No. 4 Lao Cai Province
138
Filter for hematemia
2
Pieces
Density: 0.9 g/cm3 Tensile elasticity: 1400 MPa Tensile strength: 33 MPa Flexural coefficient: 1400 MPa Flexural strength: 40 MPa Deformation temperature: 85˚C
General Hospital No. 4 Lao Cai Province
139
Mushroom identification card
50
Bar
- Used for quick identification of most types of yeast and yeast-like microorganisms. - Panel includes 45 biochemical substrate wells and 2 fluorescent wells. - Used with BD Phoenix Automated Microbiology System equipment - Store at 15 - 25oC.
General Hospital No. 4 Lao Cai Province
25 bars/1 box
140
Gram -negative bacterial identification card
250
Bar
- Used for rapid identification of aerobic and facultative anaerobic Gram-negative bacteria. - Panel includes 45 biochemical substrate wells and 2 fluorescent wells. - Used with BD Phoenix Automated Microbiology System equipment - Store at 15 - 25ºC.
General Hospital No. 4 Lao Cai Province
25 bars/1 box
141
Testing tests for antibiotic sensitivity of Gram -negative bacteria
250
Bar
- Used to test the sensitivity of most aerobic and facultative anaerobic Gram-negative bacteria. -Contains antibiotics and 1 growth control well. Antibiotics belong to the following groups: Beta-lactam, Aminoglycoside, Quinolone, Cyclic peptide, Fosfomycin, Nitrofuran, Glycylcycline, Folate Antagonist. - There are antibiotics: Ceftazidime-Avibactam, Ceftolozane-Tazobactam, Imipenem-Relebactam, Meropenem-Vaborbactam. -Has CPO confirmed detection test wells for Enterobacterales, Pseudomonas aeruginosa and Acinetobacter baumannii. - Group CPO into Amblers (A, B, D) for Enterobacterales. - Store at 15 - 25ºC."
General Hospital No. 4 Lao Cai Province
25 bars/1 box
142
Gram -positive bacterial identification card
250
Bar
- Used for rapid identification of aerobic and facultatively anaerobic Gram-positive bacteria. - Panel includes 45 biochemical substrate wells and 2 fluorescent wells. - Store at 15 - 25ºC.
General Hospital No. 4 Lao Cai Province
25 bars/1 box
143
Gram -positive antibiotic antibiotic card
250
Bar
- Used for testing the sensitivity of most Gram-positive aerobic and anaerobic bacteria. - Includes 28 antibiotics, belonging to the following groups: Aminoglycosides, Beta-lactams, Cyclic lipopeptides, Folate antagonists, Fosfomycin, Fusidine, Glycopeptides, Macrolide Lincosamides, Nitrofurans, Oxazolidinones, Pseudomonic acid, Quinolones, Rifamycins, Tetracyclines. - Includes Ceftaroline (a new antibiotic for treating multi-drug resistant bacteria). - Store at 15 - 25ºC.
General Hospital No. 4 Lao Cai Province
25 bars/1 box
144
Pneumococcal/streptococcal identification card and antibiogram
50
Bar
- Used for rapid identification and sensitivity testing of Streptococcus species of human origin. - Contains antibiotics and 1 growth control well. Antibiotics belonging to the following groups: Beta-lactam, Phenicol, Macrolides Lincosamides, Quinolone, Oxazolidinone, Glycopeptide, Tetracycline, Folate Antagonist, - Store at 15 - 25ºC.
General Hospital No. 4 Lao Cai Province
25 bars/1 box
145
Streptococcus/pneumococcus antibiotic indicator, minimum 6ml/vial
1
Jar
- Ingredients: (formula per 1 Liter of pure water): Redox index, less than 1.5 g; Redox stabilizer, less than 20 g - Store at 2 - 8ºC.
General Hospital No. 4 Lao Cai Province
6ml/bottle
146
General antibiotic indicator, minimum 6ml/vial
10
Jar
- Ingredients: (formula per 1 Liter of purified water): Redox indicator <3g, Redox stabilizers <20g - Store at 2 - 8ºC.
General Hospital No. 4 Lao Cai Province
6ml/bottle
147
Broth used for antibiogram, minimum 8ml/tube
500
Tube
- Ingredients: (formula per 1 Liter of purified water): 22g Mueller Hinton Broth, Polysorbate 80 0.01%. - Store at 2 - 25ºC.
General Hospital No. 4 Lao Cai Province
8 mL/tube
148
Broth used for streptococcal/pneumococcal antibiogram, minimum 8ml/tube
50
Tube
- Ingredients: (formula per 1 Liter of purified water) Pancreatic Digest of Casein, Peptones, and Supplements, 29.2 g; Thymidine Phosphorylase, 100 IU; Polysorbate 80, 0.1 g . - Store at 2 - 25ºC.
General Hospital No. 4 Lao Cai Province
8 mL/tube
149
Broth used for identification, minimum 4.5 ml/tube
500
Tube
- Ingredients (formula per 1 Liter of purified water): 7.5g Potassium chloride, 0.5g Calcium chloride, 0.895g Tricine glycine, Polysorbate 80 0.025%,. - Store at 2 - 25ºC.
General Hospital No. 4 Lao Cai Province
4.5mL/tube
150
Adult aerobic blood culture bottle
150
Bottle
- Used in the cultivation and resuscitation of aerobic microorganisms from blood samples. - Composition of the bottle: 30 mL of pre-treated water, Soybean-Casein Digest 3.0%, Yeast extract 0.25%, Amino acids 0.05%, Sugar 0.2%, Sodium Polyanetholsulfonate (SPS) 0.05%, Vitamins 0.006%, Oxidizing/Reducing agent 0.005%, Nonionic Adsorbing Resin 13.4%, Cationic Exchange Resin 0.9%, with added CO2. - Store at 2 - 25ºC. - The bottle contains a chemical sensor that is monitored by the blood culture machine every 10 minutes to detect an increase in fluorescence.
General Hospital No. 4 Lao Cai Province
50 bottles/Box
151
Adult anaerobic implant bottle
100
Bottle
- Used in the cultivation and recovery of anaerobic microorganisms from blood samples. - Composition of the medium in the bottle: 40 mL of pre-treated water, Soybean-Casein Digest at 2.75%, Yeast extract at 0.2%, Animal protein at 0.05%, Dextrose at 0.2%, Hemin at 0.0005%, Menadione at 0.00005%, Sodium Citrate at 0.02%, Thiols at 0.1%, Sodium Pyruvate at 0.1%, Saponin at 0.26%, Anti-foaming agent at 0.01%, Sodium Polyanetholsulfonate (SPS) at 0.035%, with added CO2 and N2. - Store at 2 - 25ºC. - The bottle contains a chemical sensor that is monitored by the blood culture machine every 10 minutes to detect an increase in fluorescence.
General Hospital No. 4 Lao Cai Province
50 bottles/Box
152
Blood culture bottles detect mycobacteria and fungi
50
Bottle
- Can be used in the cultivation and recovery of tuberculosis, yeast, and fungi from blood, as well as for inoculating sterile body fluids. - The bottle contains a non-selective culture medium consisting of: 40 mL of pre-treated water, 7H9 Middlebrook broth without phosphate salts (0.07%), Brain Heart Infusion (0.5%), Hydrolyzed Casein (0.10%), Supplement H (0.10%), Inositol (0.005%), Glycerol (0.10%), Dextrose (0.1%), Sodium Polyanetholsulfonate (0.025%), Polysorbate 80 (0.0025%), Pyridoxal HCl (0.0001%), Ferric Ammonium Citrate (0.01%), Potassium Phosphate (0.024%), Saponin (0.24%), Anti-foam agent (0.01%), with added CO2 and O2. - Store at 2 - 25°C. - The bottle contains a chemical sensor that is monitored by the blood culture machine every 10 minutes to detect increases in fluorescence.
General Hospital No. 4 Lao Cai Province
50 bottles/Box
153
Children's blood culture bottle
100
Bottle
- Used in the cultivation and recovery of aerobic microorganisms from blood samples, as well as other samples with a volume of up to 3 mL. - Composition of the medium in the bottle: 40 mL of pre-treated water, Soybean-Casein Digest powder at 2.75%, Yeast extract at 0.25%, Animal derived component at 0.10%, Sodium Pyruvate at 0.10%, Dextrose at 0.06%, Sucrose at 0.08%, Hemin at 0.0005%, Menadione at 0.00005%, Sodium Polyanetholsulfonate (SPS) at 0.020%, Pyridoxal HCl (Vitamin B6) at 0.001%, Nonionic Adsorbing Resin at 10.0%, Cationic Exchange Resin at 0.6%, with added CO2. - Store at 2 - 25ºC. - The bottle contains a chemical sensor that is monitored by the blood culture machine every 10 minutes to detect an increase in fluorescence.
General Hospital No. 4 Lao Cai Province
50 bottles/Box
154
Blood jelly
250
Plate
The ready-to-use agar plates contain a suitable environment for cultivating and testing the properties of difficult and non-fastidious microorganisms. Plate size: 90mm. Packaging: Cellophane film. Composition: Special peptone, starch, sodium chloride, defibrinated sheep blood, agar. pH: 7.3 ± 0.2 at 25°C. Package: 10 plates/box
General Hospital No. 4 Lao Cai Province
155
Chocolate jelly
250
Plate
Ready-poured agar plates supplemented with growth stimulants are used to cultivate difficult-to-grow microorganisms, especially Neisseria spp. and Haemophilus, contain no additives or preservatives. Meets: "Manufacturer's minimum quality control requirements for pre-poured culture media", according to CLSI standards. 90mm disc. Packed with semi-permeable Cellophane membrane with moisture-proof properties to help ensure quality during storage, and easily decompose to protect the environment. Ingredients: Special peptone, Starch, Sodium chloride, Defibrinated sheep blood, Agar, Multivitox (including Vitamin B12, L-glutamine, Adenine, Guanine, p-Aminobenzoic acid, L-cystine, NAD (Coenzyme 1), Cocarboxylase, Ferric nitrate, Thiamine, Cysteine hydrochloride), pH: 7.3 ± 0.2 at 25°C Packaging: 10 Disc/Box
General Hospital No. 4 Lao Cai Province
156
Jelly uti
100
Plate
Opaque white pre-filled agar plates containing chromogenic medium are used for the preliminary identification and differentiation of all major microorganisms that cause urinary tract infections (UTIs). 90mm disc. Packed with semi-permeable Cellophane membrane with moisture-proof properties to help ensure quality during storage, and easily decompose to protect the environment. Ingredients: Peptone, Chromogenic mix, tryptophane, Agar, pH: 6.8 ±0.2 at 25°C; Packaging: 10 discs/Box
General Hospital No. 4 Lao Cai Province
157
Macconkey agar
100
Plate
Pre-filled agar plates contain isolation and differentiation media for the detection of Enterobacteriaceae bacteria in clinical samples. Meets: "Manufacturer's minimum quality control requirements for pre-poured culture media", according to CLSI standards. 90mm disc. Packed with semi-permeable Cellophane membrane with moisture-proof properties to help ensure quality during storage, and easily decompose to protect the environment. Ingredients: Peptone, lactose, Bile salts, Sodium chloride, Neutral red, Crystal Violet, Agar, pH: 7.1±0.2 at 25°C Packaging: 10 discs/Box
General Hospital No. 4 Lao Cai Province
158
Sabouraud Dexorose Agar
30
Plate
Pre-filled agar plates containing a low pH medium are often used to culture and differentiate different types of fungi, molds, and yeasts. 90mm disc. Packed with semi-permeable Cellophane membrane with moisture-proof properties to help ensure quality during storage, and easily decompose to protect the environment. Ingredients: Mycological peptone, Glucose (dextrose), Agar, pH: 5.6 ± 0.2 at 25°C Packaging: 10 discs/Box
General Hospital No. 4 Lao Cai Province
159
Nutrition -rich environment for culture of microorganisms including fastidious microorganisms
2
Box
Plastic tube contains 5ml of nutrient-rich medium used to culture microorganisms, including fastidious microorganisms. Meets: "Manufacturer's minimum quality control requirements for pre-poured culture media", according to CLSI standards. Ingredients: Brain infusion solids, Beef heart infusion solids, Proteose peptone, Sodium chloride, Glucose, Disodium phosphate, pH 7.4 ± 0.2 at 25° Packaging: box of 10 tubes
General Hospital No. 4 Lao Cai Province
160
Oxidase
1
Box
Chemicals detect cytochrom oxidation enzyme reaction. The box consists of 50 tubes per tube 0.75ml containing n, n, n, n-tetramethyl-1,4-phenylenediamine, acorbic acid
General Hospital No. 4 Lao Cai Province
161
Chemicals detect the presence of catalase enzymes
2
Box
The small-volume catalase test reagent is used in a qualitative assay to determine the activity of catalase in bacteria. Catalase is present in most aerobic and facultative anaerobic bacteria, with the main exceptions being streptococci and enterococci.
General Hospital No. 4 Lao Cai Province
162
Standard f hba1c
60
Box
HbA1c quantification: Quantification range: 4 ~ 15% [NGSP], 20 ~ 140 mmol/mol [IFCC]. This is a standard test performed with the Standard F device.
General Hospital No. 4 Lao Cai Province
163
Standard ™ Q Dengue Ns1 Ag Test
300
kiểm TRA
- Detects NS1 antigens of Dengue virus in human serum, plasma or whole blood samples - Relative sensitivity: 92.42 % (183/198) compared to RT-PCR - Relative specificity: 98.7% (222/225) compared to RT-PCR - 100% accuracy - Test kit is stable for at least 8 weeks when stored at a temperature of 55±1°C - Detection limit (For Den-1, 2, 3, 4) is: 3.9 ng/ml - No cross-reactivity with the following strains: Chikungunya virus, Zika virus, Streptococcus pneumoniae, Streptococcus pyogenes, Legionella pneumophila, Malaria Plasmodium falciparum, Malaria Plasmodium vivax, Influenza A (H1N1,H3N2), Influenza B, E.coli (k99), Salmonella (Typhi), Rotavirus type I, Rotavirus type II, Rotavirus type III, Rotavirus type IV, samples positive for HBV antigen, Samples positive for CMV Ab, samples from people vaccinated against yellow fever virus, Japanese encephalitis virus, HAV virus, Rubella virus - No interference reactions with EDTA, Heparin, Sodium citrate, Hemoglobin, Human Albumin, Bilirubin, Ribavirin, Doxycycline hydrate, Aspirin, Ciprofloxacin, Quinine, Ibuprofen, Acetaminophen. - Blood fat samples and samples containing rheumatoid factor do not affect the test results - Storage: 2-40oC - Main ingredients: Test line T: Anti-Dengue NS1 monoclonal antibody, Control line C: monoclonal anti-chicken IgY antibody, Gold buffer: Anti-Dengue NS1 monoclonal antibody-gold conjugate, Chicken IgY-gold conjugate
General Hospital No. 4 Lao Cai Province
164
STANDARD™ Q Dengue IgM/IgG Test
300
kiểm TRA
- Detection of IgM/IgG antibodies against dengue virus in serum, plasma, or whole blood samples - Comparable sensitivity: 97.4% (for Dengue IgM); 97.2% (for Dengue IgG) compared to ELISA - Comparable specificity: 96.6% (for Dengue IgM); 96.2% (for Dengue IgG) compared to ELISA - 100% accuracy - Storage: 2-40°C - Stable test strip for at least 5 weeks when stored at 55±1°C - Detection limit of 3.9ug/ml for Dengue IgM / IgG - Does not cross-react with HBV, Chikungunya IgG, Zika IgM, Syphilis Ab, HIV-1, HIV-2, HCV, CMV Ab, Yellow Fever virus, Japanese Encephalitis Ab, Tick borne encephalitis Ab, Epstein Barr IgM, Parvovirus B19 Ab, Varicella Zoster Ab. - No interference with EDTA, Heparin, Sodium citrate, Hemoglobin, Human Albumin, Bilirubin, Ribavirin, Doxycycline hydrate, Aspirin, Ciprofloxacin, Quinine, Ibuprofen, Acetaminophen. - Main components: Test strip G: Monoclonal human IgG antibody; Test strip M: Monoclonal human IgM antibody; Control strip C: Mouse anti-IgG goat antibody; Yellow buffer: Recombinant Dengue yellow surface antigen; inactivated Dengue virus - The test kit includes the test strips, buffer solution, and single-use collection tubes.
General Hospital No. 4 Lao Cai Province
165
STANDARD™ Q Syphilis Antibody Test
1.000
kiểm TRA
- Rapid chromatographic immunoassay for qualitative detection of anti-syphilis antibodies from human serum, plasma or whole blood. - Sensitivity: 100%, specificity 99.1% compared to TPHA - No cross-reactivity with the following common pathogens: Plasma positive for: Dengue IgG/IgM, HBV, Chikungunya IgG, Chikungunya IgM, Zika IgG, Zika IgM, HIV-1, HCV - No interaction with compounds: EDTA, Heparin, Sodium citrate, Hemoglobin, Albumin human, Bilirubin, Ribavirin, Doxycycline hydrate, Aspirin, Ciprofloxacin, Quinine, Ibuprofen, Acetaminophen. - Storage: 2-40oC - Main ingredients: Test line: recombinant Syphilis p17; Control line: monoclonal antibody against Syphilis p17; Yellow buffer: Syphilis recombinant p17-gold
General Hospital No. 4 Lao Cai Province
166
Standard ™ Q HIV 1/2 AB 3-Line Test
2.000
kiểm TRA
- Qualitative detection of all specific antibodies to HIV-1 including subgroup O and HIV-2 in human serum, plasma or capillary and venous whole blood samples. - Sensitivity: 99.78% for plasma samples, 99.84% for serum samples, 99.01% for venous whole blood samples, 100% for capillary whole blood samples - Specificity: 100% for plasma and whole blood samples, 99.92% for serum samples. - 100% sensitivity, 100% specificity for HIV-1 and HIV-2 - Test kit includes test tray (in individual bags), capillary tube, test solvent, needle, alcohol cotton - Main components: T1 test line: recombinant protein gp41 of HIV-1, gp41 of HIV-1 subtype O; Test line T2: gp36 of HIV-2; Control line: monoclonal antibody against chicken IgY; Conjugation buffer: HIV-1 colloidal gold gp41/HIV-1 subtype O colloidal gold gp41 conjugate; gp36 of HIV-2 colloidal gold, - Storage: 2-40oC - On the WHO PQ list. - Detection limit: Antibody against HIV-1: 11.88 (S/CO) at dilution 2^-12, antibody against HIV-2: 102.6 S/CO at dilution 2^-10, antibody against HIV-1 subgroup O: 154.5S/CO at dilution 2^-7
General Hospital No. 4 Lao Cai Province
167
Standard ™ QT HCV AB Test
1.000
kiểm TRA
- Detecting qualitative antibodies for gold in serum, plasma or whole blood. - Sensitivity: 100% - specificity: 97.67% - The specificity on the sample sample 100% (200/200), the specificity on the 100% pregnant woman (204/204), the specificity on the 100% potential cross -reaction sample - not affected by the compounds that are often present in the sample: ribavirin, caffeine, ethanol, total blood of the hepatitis, no diagonal reaction with micro -micro -races: B, Influenza A/B, Dengue, Rotavirus, Syphillis, Rubella, Salmonella, ... - Storage: 2-40 ° C - In the list of WHO PQ - Kit stabilized 13 tu at a temperature of 55 ± 1 ° C - Main component: Test line: Human antibody antibodies; Demonstration: Single antibodies of chicken resistance, combined cushion: Antigen of HCV NS3/NS4/NS4/NS5/Recombinant core - Gold glue; Gold chicken igy - Detection limit: 1. Genotype 1A: 7.54 (S/CO) 2. Genotype 2B: 1.38 (S/CO) 3. Genotype 3A: 1.53 (S/CO)
General Hospital No. 4 Lao Cai Province
168
STANDARD™ Q IgM Test
500
kiểm TRA
- Detection of IgM anti-HAV antibodies in serum, plasma, or whole blood - Sensitivity: 100%; Specificity: 98.04% - Storage: 2-40°C - Kit is stable for 3 months at 60±1°C - Expiry date: 24 months from the date of manufacture - Main components: Test line: Monoclonal anti-human IgM antibody; Control line: Monoclonal anti-HAV antibody; Conjugate buffer: Monoclonal anti-HAV-yellow antibody; purified natural anti-HAV antibody
General Hospital No. 4 Lao Cai Province
169
STANDARD™ Q HBsAg Test
3.000
kiểm TRA
Qualitative detection of hepatitis B virus surface antigen (HBsAg) present in serum, plasma or whole blood. No buffer solution (Buffer vial) is needed. Sensitivity: 100%, specificity: 100% compared to CLIA. Stable for 8 weeks at 55 +/-1oC. 100% accuracy. Storage: 2-40oC No cross-reactivity with: Chikungunya, Zika, S.pneumoniae, S.pyogenese, Legionella pneumoniae, Malaria Plasmodium falciparum, Malaria Plasmodium vivax, Influenza A (H1N1, H3N2), Influenza B, E.coli (k99), Salmonella typhi, Rotavirus types I, II, III, IV No interference reactions with: blood lipid samples (Triglycerides/Cholesterol), anticoagulants, human anti-mouse antibodies, whole blood of pregnant women, blood with elevated hemoglobin concentration, serum with rheumatoid factors (RF factor), samples with elevated C-reactive protein concentrations. -Main ingredients: Test line: monoclonal anti-HBs antibody; Control line: monoclonal anti-IgY antibody-chicken Content: - Monoclonal anti-HBs antibody: 0.75 ± 0.15µg - Monoclonal anti-chicken IgY antibody: 0.6 ± 0.12µg - Monoclonal anti-HBs antibody - gold colloidal: 0.08± 0.16µg - Chicken IgY - gold colloidal: 0.015 ± 0.003µg - Detection limit: can detect HBsAg strain ADR and strain AYW from a concentration of 0.01562 µg/ml, and strain ADW from a concentration of 0.03125 µg/ml - Test trays are packed in individual aluminum bags, with desiccant bags; The supplied kit includes a test tray and disposable plastic pipettes.
General Hospital No. 4 Lao Cai Province
170
STANDARD™ Q Malaria P.f/P.v Antigen Test
200
kiểm TRA
Qualitative detection and differentiation of P.falclparum specifically HRP-2 and Plasmodium vivax specifically pLDH in capillary/venous whole blood samples - Sensitivity: for Malaria P.f is 99.59% (487/489 95%CI: 98.53-99.95%), for Malaria P.v is 100% (123/123 95%CI: 97.05-100%); Specificity: 100% (1006/1006 95%CI: 99.63-100%) - Malaria P.f detection limit is 183 parasites/µl; Malaria P.v is 228 parasites/µl - Storage: 2-40oC - Main ingredients: Test line: P.f test line: monoclonal antibody against P.falciparum HRP-2, P.v test line: monoclonal antibody against Malaria P.vivax; Control line: monoclonal antibody against chicken IgY - Test trays are individually packaged in aluminum bags, with desiccant packs. The kit includes a plastic sampler, buffer solution, blood lancet, and alcohol swab. Can be used with antifreezes such as Heparin, EDTA, Sodium Citrare. - Does not cross-react with hepatitis A virus, hepatitis B, hepatitis C, respiratory tract infections (Influenza A, B), vector-borne diseases (Chikungunya, Dengue, Yellow fever virus), intestinal infections (Rotavirus, Ecoli k99, Salmonella Typhi), Streptococcus pneumonia, Streptococcus pyogenes, Legionella pneumophila, Treponema pallidum, does not cross-react with seroconversion panel HIV, HCV-positive plasma/HCV core antigen, HBsAg-positive plasma, HAV IgM, Dengue IgM, Chikungunya, Zika, Salmonella typhi IgM, Leishmania, Japanese encephalitis, West Nile virus, Brucella IgM-positive plasma, tick-borne encephalitis IgM - No interaction with: Artemether-lumefantrine (antimalarial drug), doxycyline hyclate (treatment drug) malaria), Lamivudine (virus inhibitor), Acetaminophen, Erythromycin, Ibuprofen, Acetylsalicylic acid, Bilirubin (unconjugated), Caffeine, ethanol, human anti-mouse antibodies, whole blood of pregnant women and young children, whole blood with high Hb concentration, samples with high C-reactive protein (high CRP) concentration, fatty blood samples.
General Hospital No. 4 Lao Cai Province
171
STANDARD™ Q Tsutsugamushi IgM/IgG Test
200
kiểm TRA
Detection of Orientia tsutsugamushi-specific IgM/IgG antibodies in serum, plasma, and whole blood – Key components: human IgG monoclonal antibody, human IgM monoclonal antibody; GST monoclonal antibody; TTG Boryeong/TTG Karp/TTG Gilliam/TTG Kato recombinant antigens linked to gold conjugates - Storage: 2-40°C. - Detection limit: IgM at a dilution of 1:128 and IgG at a dilution of 1:4096 - Sensitivity: 100% - Specificity: 95.85% - The test kit is packaged in individual aluminum pouches with desiccant packs. The kit includes a test tray, plastic sample pipettes, and buffer solution. – Does not cross-react with: other hepatitis viruses, respiratory tract infection viruses, vector-borne disease viruses, intestinal infection bacteria, HIV seroconversion; positive for: Japanese encephalitis IgG/IgM, CMV IgG/IgM, Tick-borne encephalitis IgM, West Nile virus, Treponema pallidum, HAV IgM, HAV IgG, Leishmania, Brucella IgM
General Hospital No. 4 Lao Cai Province
172
STANDARD™ Q Rotavirus Antigen Test
500
kiểm TRA
- Detection of group A Rotavirus antigen in human stool samples. - Sensitivity: 100%; Specificity: 100% compared to PCR and ELISA - 100% accuracy, 100% reproducibility - Test kit is stable for at least 9 months at a temperature of 55±1°C - Storage temperature: 2-30 degrees Celsius - Detection limit of Rotavirus group A is approximately 2 x 10^6 ~ 1.15 x 10^6 PFU/ml - Does not cross-react with agents that commonly cause respiratory diseases: Influenza A (H1N1, H3N2), Influenza B; Vector-borne diseases: S.pneumoniae, Chikungunya, Zika; Gastrointestinal diseases: E.coli (k99), Salmonella group B/C/D/typhi, Clostidium cifficile, Aeromonsa hydrophila, Bacillis cereus, Citrobacter freundii, Enterobacter aerogenes, Proteus mirabilis, Serratia liquefaciens, Staphylococcus aureus, Enterococcus faecalis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Enterobacter cloacea, Vibrio parahaemolyticus, Candida albicans, Shigella flexneri, Shigella boydii, Shigella sonnei, Norovirus - Does not interact with: Bilirubin, Hemoglobin, Triglyceride, Cholesterol, BSA, Mucin, whole blood, DMSO, PBS, metronidzole, levofloxacin, Ibuprofen, Cerfixime, DMF, - Main ingredients: Anti-mouse monoclonal antibody Rotavirus; Control line: mouse monoclonal antibody against rabbit IgG; Yellow buffer: Rabbit polyclonal antibody against Rotavirus
General Hospital No. 4 Lao Cai Province
173
STANDARD™ QR Rota/Adeno Antigen Detection Kit
200
kiểm TRA
- Rapid immunochemical test for the qualitative detection of Rotavirus and Adenovirus antigens in human stool samples. – For Rotavirus: Sensitivity 100% (95% CI: 96.34 - 100.00%); Specificity 96.75% (95% CI: 92.59-98.94%) compared to PCR and ELISA; Detection Limit Approximately 2.3 x 10^6 ~ 1.15 x 10^6 PFU/ml – For Adenovirus: Sensitivity 97.89% (95% CI: 92.60-99.74%); Specificity 99.25% (95% CI: 95.91-99.98%) compared to PCR and ELISA; Detection Limit Approximately 2.34 x 10^4 ~ 1.17 x 10^4 PFU/ml – Accuracy 100%, Repeatability 100% – Kit stability for at least 9 months at 55±1°C – Storage temperature: 2-30°C – No cross-reactivity with common respiratory pathogens: Influenza A (H1N1, H3N2), Influenza B; Vector-borne diseases: S.pneumoniae, Chikungunya, Zika; Gastrointestinal infections: E.coli (K99), Salmonella group B/C/D/typhi, Clostridium difficile, Aeromonas hydrophila, Bacillus cereus, Citrobacter freundii, Enterobacter aerogenes, Proteus mirabilis, Serratia liquefaciens, Staphylococcus aureus, Enterococcus faecalis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Enterobacter cloacea, Vibrio parahaemolyticus, Candida albicans, Shigella flexneri, Shigella boydii, Shigella sonnei, Norovirus – No reaction with interfering substances: Bilirubin, Hemoglobin, Triglycerides, Cholesterol, BSA, Mucin, Whole blood, DMSO, PBS, metronidazole, levofloxacin, Ibuprofen, Cerfixime, DMF – Main components: Test line T1: Single-specificity mouse antibody against Adenovirus; Test line T2: Single-specificity mouse antibody against Rotavirus; Control line C: Single-specificity rabbit IgG antibody against Adenovirus; Yellow buffer: Single-specificity mouse antibody against Adenovirus-yellow; Multi-specificity rabbit antibody against Rotavirus-yellow
General Hospital No. 4 Lao Cai Province
174
SERODIA-TP.PA
220
kiểm TRA
Gelatin precipitation assay to detect antibodies against *Treponema pallidum* in human serum or plasma. Sensitivity: 100%; Specificity: 100%
General Hospital No. 4 Lao Cai Province
175
SARS-CoV-2/FLU A/FLU B/RSV/ADV antigen qualitative test tray
500
kiểm TRA
Kit Components: * 20 Test Cassettes * 20 Sterile Swabs with Collection Buffer Solution * 20 Throat Swab Sticks * 20 Nasopharyngeal Swab Sticks * 1 Instruction Manual SARS-CoV-2 Detection Performance: * Sensitivity: 97.88% * Specificity: 99.41% Influenza A Detection Performance: * Sensitivity: 98.15% * Specificity: 99.65% Influenza B Detection Performance: * Sensitivity: 97.62% * Specificity: 99.32% Adenovirus (ADV) Detection Performance: * Sensitivity: 97.80% * Specificity: 99.91% Respiratory Syncytial Virus (RSV) Detection Performance: * Sensitivity: 97.37% * Specificity: 96.28% Results should be observed after 15 minutes and are considered invalid if read after 20 minutes.
General Hospital No. 4 Lao Cai Province
Other attachments

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Approval decision information
Approval decision file

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Request quotation of goods". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Request quotation of goods" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 1

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second