Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Negative pressure suction machine |
2 |
Female |
Electrical power: AC, 50-60 Hz
Consumption current: 0.015A (at 220V)
Suction suction range: -3 --20 cmH2O
Maximum suction capacity: 1.2 liters/minute and better
Capacity of containers: 1,400 ml, made of polycarbonate
Size: 332 (height) x 375 (long) x 150 (deep) mm |
Yen Lap Medical Center |
|||
2 |
Suspension price of antiseptic solution |
50 |
Female |
Stainless steel material, 1000ml round bottle |
Yen Lap Medical Center |
|||
3 |
The fork lock |
1.000 |
Female |
The fork lock is not connected
- Rotate male locking connector
- 3 -wing valve, made of polyethylene (PE), rotates 360 degrees, with arrows indicating the flow, the flow shut down every 90 degrees.
- Polycarbonate plastic lock body (PC)
- residual volume: 0.1 - 0.3 ml |
Yen Lap Medical Center |
1 blister, |
||
4 |
T has a lithium heparin anticoagulant |
24.000 |
Tube |
Test tube size 12x75mm; The body of the tube produced from polypropylene plastic material (PP), non -toxic primeval, is allowed to be used in health
- Volume: 2ml
- Inner chemicals are heparine lithium anticoagulant.
- Used to separate plasma to test the electrolyte (Na₊, K₊, Cl₊ ... except Li₊), blood gas. Also used for biochemical tests, especially NH3 and quantify alcool in the blood.
- Test tube lid: Attach black plastic lid.
- Meeting ISO 13485: 2016, ISO 9001: 2015 |
Yen Lap Medical Center |
100 tubes/ tray |
||
5 |
EDTA anticoagulant tube |
24.000 |
Tube |
PP plastic tube. Size 12-13x75mm
Used to separate plasma to test hematology (blood formula and Hbalc ...)
The chemical inside is EthyliatiaMinetetra acid dipotasium (EDTA K2)
Test tube lids: Blue plastic lids/ lids. Color of lid may vary depending on the need
Test tubes are closed on high mous base or low mous base. |
Yen Lap Medical Center |
100 tubes/ tray |
||
6 |
Gloves |
10.000 |
Pair |
Gloves are manufactured from natural rubber, unprocessed, only used once and both hands, covered with powder, length ≥ 220mm |
Yen Lap Medical Center |
100 pcs/ box |
||
7 |
Chemicals for troponin tests I |
3 |
Box |
The reaction well is used for troponin I AIA series, testing method: Immunosuppression of fluorescent emission, measuring range 0.02 - 50 ng/ml, ISO 13485 standard |
Yen Lap Medical Center |
100test |
||
8 |
Chemicals for TSH tests |
3 |
Box |
Reaction well for TSH tests, used for AIA models, testing methods: Immunosuppression of fluorescent emission, measuring range 0.01 - 100 μiu/ml, ISO 13485 standard |
Yen Lap Medical Center |
100test |
||
9 |
Sample tip (sample tip) |
3 |
Box |
The taper taper sucks the sample for the AIA series |
Yen Lap Medical Center |
1000 PCS/BAG |
||
10 |
Machine cup |
1 |
Box |
Standard well used for AIA models, testing methods: Immunosuppression of fluorescent, ISO 13485 standard |
Yen Lap Medical Center |
200test |
||
11 |
Sample dilution cup |
1 |
Box |
The well dilute the sample for the AIA series, the test method: Immunosuppression of fluorescent emission, ISO 13485 standard |
Yen Lap Medical Center |
200test |
||
12 |
10-liter CO2 (gas-does not include jar shell) |
5 |
Jar |
- purity ≥99.9%
- Close in 10 liters
- Balancing pressure ≥ 57.29 bar at 20 degrees Celsius |
Yen Lap Medical Center |
10 -liter bottle |
||
13 |
Oxygen of 40L bottle |
600 |
Jar |
- purity
≥ 99.5%
- Load pressure 145 bar
- Pressure used
130 bar
- Close in the bottle
40 liters |
Yen Lap Medical Center |
40 liter bottle |
||
14 |
HBA1C testing set on high -pressure liquid chromatography |
800 |
kiểm TRA |
Used to determine % HBA1C by high -pressure liquid chromatography (HPLC) on MQ2000PT, MQ3000PT testing machine
Code: hc207t05
The kit includes:
01 liquid chromatography HBA1C (HPLC)
01 HBA1C cushion (A); (2x1800ml)
01 HBA1C cushion (B); (1x1400ml)
01 Haemolyser solution; (4x1800ml)
01 sample dilution tube; 100 vials /bag
02 filters
06 printing paper for thermal printers
Active ingredients:
HBA1C A: (pH5 ~ 6) Sodium xitrate dihydrate, cylinder acid monohydrate, isothiazolinone, sodium azit, water.
HBA1C B: (PH6 ~ 7): Sodium xitrat dihydrate, Xitric Monohydrate acid, isothiazolinone, sodium azit, water.
HBA1C HAEMOLYSER: (PH6 ~ 8): Disodium hydrogen orthophosphate, sodium dihydrogen orthophosphate, surfactants, sodium azit, water. |
Yen Lap Medical Center |
800 Test / set |
||
15 |
Electrolyte chemicals ion |
5.500 |
ML |
Used for Hylyt300, AS 930 electrolytes.
To measure the free ionic concentration parameters in the blood of Na/K/Cl/Li according to the electrode method selected the ion.
Code: ASR5035-00
Capacity: STD A 390 ml+ STD B 160 ml
Ingredients: STD A: K+: 1.1%, Na+: 57.0%, Cl-: 40.5%, Ca2+: 0.5%, Li+: 0.4%, Mg2+: 0.5%.
STD B: K+: 4.0%, Na+: 57.5%, Cl-: 36.5%, Ca2+: 1.3%, Li+: 0.3%, Mg2+: 0.4%.
On the chemical box there is 01 card to identify chemicals. |
Yen Lap Medical Center |
390 ml+ 160 ml |
||
16 |
Chemicals Measure CK-NAC activity |
640 |
ML |
Chemicals to determine the quantitative activity of creatine kinase in human serum.
Ingredients: R1- Creatine phosphate: 30 mmol/l, d-glucose: 20 mmol/l, n-acetyl-l-cystein: 20 mmol/l, AMP: 5mmol/l, ADP: 2 mmol/l, NADP: 2 mmol/l, AP5A: 10 µmol/l, G-6-PDH> 2500 IU IU/l); R2- IMidazole acetate pH 6.7: 100 mmol/l, EDTA Na2: 2 mmol/l, magnesium acetate: 10 mmol/l, surfactants, stabilizers).
Linear range: from 12 to 800 IU/L
Discovery limit: about 4 IU/l
Analysis sensitivity: about 0.0035 ABS/min for 10 IU/L.
C.V% repeat level ≤ 1.1.
C.V% repeat ≤ 3.3.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 8 x 20 ml
R2: 8 x 20 ml |
||
17 |
Total bilirubin quantitative chemical |
2.200 |
ML |
Chemicals to determine the quantification of total bilirubin (DMSO as a catalyst) in serum and plasma.
Ingredients: R1- Total Bilirubin (Sulfanilic Acid: 30 mmol/l, dmso: 7 mol/l, hydrochloric acid: 130 mmol/l); R3- Total and Direct Bilirubin (sodium nitrite: 0.74 mmol/l).
Linear range: TB from 0.45 to 20 mg/dl
Detection limit: TB is about 0.28 mg/dl
Calculation sensitivity for 1 mg/dL: TB is about 0.0853 ABS
C.V % repeat level (TB) ≤ 2.5 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 2 x 200 ml
R3: 1 x 40 ml |
||
18 |
Direct bilirubin quantitative chemicals |
2.200 |
ML |
Chemicals to determine the quantification of bilirubin directly in serum and plasma.
Ingredients: R2- Direct Bilirubin (Sulfanilic Acid: 30 mmol/l, hydrochloric acid: 130 mmol/l); R3- Total and Direct Bilirubin (sodium nitrite: 0.74 mmol/l).
Linear range: dB from 0.60 to 8.0 mg/dl.
Detection limit: DB is about 0.01 mg/ dl.
Calculation sensitivity for 1 mg/dL: DB is about 0.0819 ABS.
C.V % repeat level (db) ≤ 2.8 %
C.V % repeat level (db) ≤ 3.5 %
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R2: 2 x 200 ml
R3: 1 x 40 ml |
||
19 |
Chemicals measuring GOT/AST activity |
3.000 |
ML |
Chemicals to determine the activity quantitative of Aspartate Amino Transferase (AST) in serum and plasma.
Ingredients: R1- AST enzyme cushioning (L-Aspartate: 275 mmol/l, MDH ≥ 1000 UI/L, LDH ≥ 500 UI/L, EDTA 6 mmol/l, cushioning 105 mmol/l, pH at 30 degrees C: 7.80 ± 0.1, stable substance); R2- AST Coenzym (buffer: 20 mmol/l, nadh ≤ 1.4 mmol/l, 2-oxoglutarate: 80 mmol/l, stable substance).
Linear band: from 9 to 500 IU/L
Discovery limit: about 5 IU/l.
Analysis sensitivity: about 0.0063 ABS/min for 10 IU/L.
C.V % repeat level ≤ 4.2 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 4 x 100 ml
R2: 1 x 100 ml |
||
20 |
Chemicals measuring GPT/ALT activity |
3.000 |
ML |
Chemicals to determine the activity quantitative of Alanine Amino Transferase (ALT) in serum and human plasma.
Ingredients: R1- Alt enzyme cushioning (L-alanine: 700 mmol/l, LDH ≥ 2500 UI/L, EDTA: 6 mmol/l, cushioning 135 mmol/l, pH at 30 degrees C 7.5 ± 0.1, stable substance); R2- Alt Coenzym (20 mmol/l, nadh buffer ≤ 1.4 mmol/l, 2-oxoglutarate 80 mmol/l, stabilizer).
Linear range: from 10 to 390 IU/l.
Discovery limit: about 9 IU/l.
Analysis sensitivity: about 0.0066 ABS/min for 10 IU/L.
C.V % repeat level ≤ 4.3 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 4 x 100 ml
R2: 1 x 100 ml |
||
21 |
Triglyceride quantitative chemicals |
800 |
ML |
Chemicals to determine the quantitative activity of triglycerides (tri) in serum and plasma.
Ingredients: R1- reagent tri (pipes: 100 mmol/l, magnesium chloride: 9.8 mmol/l, chloro-4-phenol: 3.5 mmol/l, lipase ≥ 1000 IU/l, peroxidedase ≥ 1700 IU/l, glycerol 3 phosphate oxidase ≥ 2000 IU/l, glycerol kinase 4-Amino-Antyrine: 0.5 mmol/l, adenosine triphosphate Na: 1.3 mmol/l, clearing agent: 1.5 mmol/l); R2- Etalon standard substance (Triglycerides 2G/L).
Linear range: from 10 to 1000mg/dl.
Detection limit: about 6 mg/dL.
Analysis sensitivity: about 0.00018 ABS for 1 mg/dl.
C.v % repeat level ≤ 1.6 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 4 x 100 ml
R2: 1x 5 ml |
||
22 |
Glucose quantitative chemicals |
4.000 |
ML |
Chemicals to determine the quantitative glucose in serum and human plasma, urine or cerebrospinal fluid (CSF).
Ingredients: R1- Glucose God Pap reagent (150 mmol cushion phosphate, glucose oxidase (God): ≥ 2000 UI/L, Peroxidase (POD): ≥ 1000 UI/L, 4-Amino-Antyrine (PAP): 0.8 mmol/l, Chloro-4 -phenol: 2 mmol/l); R2- Glucose God Pap standard (Glucose 100 mg/dl (5.55 mmol/l)).
Linear range: from 8 to 500 mg/dl
Detection limit: about 2 mg/dL.
Analysis sensitivity: about 0.060 ABS/minute for 10 mg/dL.
C.V % repeat ≤ 1.9 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 2 x 200 ml
R2: 1 x 5 ml |
||
23 |
Chemicals measuring amylase activity |
480 |
ML |
Chemicals to determine quantitative α -amylase in serum and plasma or urine.
Ingredients: R1- Amylase CNPG3 Buffer (Calcium Acetate: 6.0 mmol/l, Mes buffer pH 6.0 at 25 degrees C: 100 mmol/l, preservatives); R2- Amylase CNPG3 substrate (CNPG3: 2.25 mmol/l, potassium thiocyanate: 900 mmol/l, NaCl: 350 mmol/l).
Linear range: from 6 to 2000 IU/L.
Discovery limit: about 3 IU/l.
Analysis sensitivity: about 0.003 ABS/min for 10 IU/l at 405Nm wavelength.
C.V% repeat ≤ 2.5.
C.V% repeat ≤ 2.2.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 8 x 30 ml
R2: 8 x 30 ml |
||
24 |
Creatinin quantitative chemicals |
2.500 |
ML |
Chemicals to determine quantitative creatinine in serum and plasma or urine.
Ingredients: R1- Creatinine reagent 1 (Disodium phosphate: 6.4 mmol/l, sodium hydroxide: 150 mmol/l); R2- Creatinine reagent 2 (sodium dodecyl sulfate: 0.75 mmol/l, picric acid: 4.0 mmol/l, pH 4.0); R3- Creatinine standard.
Linear range: from 22 to 1328 µmol/l (15 mg/dl).
Detection limit: 4.4 µmol/l (0.05 mg/dl).
Calculation sensitivity: About 0.018 ABS/120 seconds for 1 mg/dl (88.5 µmol/l).
C.V % repeat ≤ 1.8 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 1 x 125 ml
R2: 1 x 125 ml
R3: 1 x 10 ml |
||
25 |
Total calcium quantitative chemical |
2.000 |
ML |
Chemicals to determine the quantitative calcium in serum, plasma or urine.
Ingredients: R1- Calcium Arsenazo III reagent (IMidazol buffer solution pH 6.8 at 25 degrees C> 90, Arsenazo III> 0.18 mmol/l, surfactants: 0.1%, preservatives); R2- Calcium Arsenazo III standard (Calcium 10 mg/dl (2.5mmol/l)).
Linear range: from 6 to 20 mg/dl
Detection limit: about 0.01 mg/dl.
Calculation sensitivity: About 0.054 ABS for 1 mg/dL.
C.V % repeat level ≤ 0.8 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 2 x 125 ml
R2: 1 x 10 ml |
||
26 |
Albumin quantitative chemicals |
1.200 |
ML |
Chemicals to determine the quantitative albumin in serum and plasma.
Ingredients: R1- Albumin reagent (Succinic Acid: 83 mmol/l, BCG: 167 µmol/l, sodium hydroxide: 50 mmol/l, polyoxyethylene monolauryl ether: 1.00g/l, preservatives); R2- Albumin Quality Quality (Bovine Albumin 5.0 G/DL (725 µmol/l)).
Linear range: from 0.4 to 7.0 g/dl
Detection limit: about 0.01 g/dl.
Analysis sensitivity: About 0.0125 ABS for 0.1g/DL.
C.v% repeat level ≤ 1.5%
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 2 x 200 ml
R2: 1 x 5 ml |
||
27 |
Urea quantitative chemical |
2.000 |
ML |
Chemicals to determine URE quantitative serum and plasma or urine.
Ingredients: R1- Urea enzyme cushion (tris pH 7.9 ± 0.1 at 30 degrees C: 100 mmol/l, urease ≥ 17000 IU/l, GLDH ≥ 700 IU/L, Oxoglutarate: 6.5 mmol/l, preservatives); R2- Urea Coenzyme (NADH ≥ 1.5 mmol/l, preservatives); R3- Urea standard (Urea: 40 mg/dl (6.66 mmol/l)).
Linear range: from 11 to 250 mg/dL.
Detection limit: about 1.7 mg/dL.
Analysis sensitivity: about 0.0012 ABS/minute for 1 mg/dl.
C.V % repeat ≤ 3.5 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 4 x 100 ml
R2: 1 x 100 ml
R3: 1 x 10 ml |
||
28 |
CRP quantitative chemicals |
1.300 |
ML |
Chemicals used to determine quantitative C-Reactive protein (CRP) in human serum.
Ingredients: R1- CRP cushioning rays (Phosphate saline pH 7.43, polyethylene glycol: 40 g/l, sodium azide: 0.95 g/l); R2- CRP Anti-CRP rays (Phosphate salt water pH: 7.43, CRP of multi-line antibiotic (goat), sodium azide: 0.95 g/l).
Linear range: from 0.4 mg/dL to 24.8 mg/dl.
Detection limit: 0.26 mg/dl
C.V % repeat level ≤ 6.3 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 6 x 20 ml
R2: 1 x 10 ml |
||
29 |
Total protein quantitative chemicals |
1.000 |
ML |
Chemicals to determine the quantitative protein in the serum and plasma.
Ingredients: R1- Total protein reagent (sodium hydroxide: 370 mmol/l, Na-K Tartrate: 10 mmol/l, potassium iodide: 3 mmol/l, copper II sulfate: 3 mmol/l); R2- Total Protein Standard (Bovine Albumin 6G/DL).
Linear range: from 0.7 to 8.0 g/dl
Detection limit: about 0.01 g/dl.
Analysis sensitivity: about 0.057 ABS (1 g/dl).
C.V % repeat level ≤ 0.96 %
C.
Quality standard: ISO 13485: 2016 |
Yen Lap Medical Center |
R1: 1 x 200 ml
R2: 1 x 5 ml |
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Trung tâm Y tế khu vực Yên Lập:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Trung tâm Y tế khu vực Yên Lập:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.