| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Monitor monitor patients 5 parameters |
2 |
Female |
- Year of manufacture: 2025 onwards • DISPLAY: Display: ≥12.1 inch, TFT color touchscreen Resolution: 800x600 Maximum display: ≥13 waveforms Battery: Capacity: ≥2550mAh, operating time ≥4h, charging time ≤3.5h (90%) Printer: 48mm paper width Paper speed: 12.5 mm/s, 25 mm/s, 50 mm/s Printing type: Continuous real-time 8s real-time 20s real-time Wi-Fi: IEEE 802.11b/g/n, Frequency band: 2.4GHz ISM band Data transmission: Data output: Ethernet/USB Data management: Patient care monitoring Central monitoring system: MFM-CMS HIS/EMR connection: HL7 Gateway software MFM-CMS/GW1 • 1. ECG: Modes: 3 leads: I, II, III; 5 leads: I, II, III, aVR, aVL, aVF, V; 6 leads: I, II, III, aVR, aVL, aVF, and feedback leads Va, Vb; 10 leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6; Standards: AHA, IEC; Display sensitivity (adjustable): 1.25 mm/mV (x0.125), 2.5 mm/mV (x0.25), 5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2), 40 mm/mV (x4), auto-adjustment; Scanning speed: 6.25 mm/s, 12.5 mm/s 25 mm/s, 50 mm/s Bandwidth (-3 dB): Diagnosis: 0.05 Hz to 150 Hz Surgery 1: 0.05 Hz to 40 Hz Monitoring: 0.5 Hz to 40 Hz Surgery: 1 Hz to 20 Hz Boost: 2 Hz ~ 18 Hz Adjustment: Low-pass filter and high-pass filter CMRR: Diagnosis: > 95 dB Monitoring: > 105 dB Surgery: > 105 dB Boost: > 105 dB Surgery 1: > 105 dB (when Notch filter is on) Adjustment: > 105 dB (low-pass filter < 40Hz) > 95 dB (low-pass filter > 40Hz) Hum filter: In diagnosis, surgery 1, monitoring, surgery, boost mode: 50Hz/60 Hz (Hum filter can be manually turned on or off) Recovery time after defibrillation: < 5s ESU Protection: Cutting mode: 300 W; Hemostasis mode: 100 W; Recovery time: ≤ 10s Pulse rate of leads One of leads I, II, III, AVR, AVL, AVF, V1, V2, V3, V4, V5, V6 • 2. RESP: Method: Transthoracic impedance: R – F (RA-LL), R – L (RA-LA) Measurement lead: Select lead I and II Measurement range: Adults: 0 rpm to 120 rpm Children/neonatal: 0 rpm to 150 rpm Resolution: 1 rpm Accuracy: Adults: 6 rpm to 120 rpm: ±2 rpm 0 rpm to 5 rpm: not specified Children: 6 rpm to 150 rpm: ±2 rpm 0 rpm to 5 rpm: not specified Adjustment selection: x0.25, x0.5, x1, x2, x3, x4, x5 Scanning speed: 6.25 mm/s, 12.5 mm/s, 25.0 mm/s, 50.0 mm/s Apnea alert time: 10s, 15s, 20s, 25s, 30s, 35s, 40s • 3. NIBP (Non-Invasive Blood Pressure Measurement): Method: Oscillometric Mode: Manual, automatic, continuous Automatic measurement mode in intervals: 1/2/3/4/5/10/15/30/60/90/120/180/240/360/480 minutes Continuous: 5 minutes, interval 5s Measurement type: SYS, DIA, MAP, PR Measurement range: Adult mode: SYS: 25 mmHg to 290 mmHg DIA: 10 mmHg to 250 mmHg MAP: 15 mmHg to 260 mmHg Pediatric mode: SYS: 25 mmHg to 240 mmHg DIA: 10 mmHg to 200 mmHg MAP: 15 mmHg to 215 mmHg Neonatal mode: SYS: 25 mmHg to 140 mmHg DIA: 10 mmHg to 115 mmHg MAP: 15 mmHg to 125 mmHg Cuff pressure measurement range: 0 mmHg to 300 mmHg Pressure resolution: 1 mmHg Maximum mean error: ±5 mmHg Maximum standard deviation: 8 mmHg Maximum measurement time: Adults/children 120s; Neonatal: 90s Typical calculation time: 20s to 35s (based on HR/movement noise) Overpressure protection: Adults: 297 mmHg ±3 mmHg; Children: 245 mmHg ±3 mmHg; Infants: 147 mmHg ±3 mmHg • 4. SpO2 (Peripheral Blood Oxygen Saturation): Measurement Range: 0% to 100% Resolution: 1% Data Update Time: 1s Accuracy: Adults/Children: ±2% (70% to 100% SpO2); Infants: ±3% (70% to 100% SpO2) • 5. Temperature (TEMP) Number of Channels: 2 Sensor Type: YSI-10K and YSI-2.252K Technique: Thermistor Measurement Parameters: T1, T2, TD Location: Skin, mouth, rectum Units: Celsius, Fahrenheit Measurement Range: 0°C to 50°C Resolution: 0.1°C Accuracy: ±0.1°C excluding sensor Sensor accuracy ≤ ±0.2°C Transient response time: ≤ 30s |
Unit name: Van Chan Regional Medical Center; Address: Village 9, Thuong Bang La commune, Lao Cai province; Email: [email protected]; Phone number: 02163 873 114 |
Unconscious |
After receiving the winning bid results: Request the contractor to provide the Certificate of Origin, CO, CQ; User manual in Vietnamese (For imported goods) |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Trung tâm Y tế Khu vực Văn Chấn:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Trung tâm Y tế Khu vực Văn Chấn:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.