Purchase additional medical equipment

Find: 16:42 18/06/2026

Bid info

Project name/purchase estimate
Request a quote: Purchasing additional medical equipment
Bid name
Additional purchase of medical equipment (2nd time) from Van Chan Regional Medical Center, Lao Cai province.

Basic information of the request for quotation

Request for quotation code
RQ2600023889-00
Status
Posted
Name of request for quotation
Purchase additional medical equipment
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
Village 9, Xã Thượng Bằng La, Province Lào Cai
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Cao Ngọc Thủy
Position
Dean of the Faculty of Pharmacy - Materials and Medical Equipment
Phone number
Address
Village 9, Thuong Bang La commune, Lao Cai province

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 18/06/2026 16:41 To date 03/07/2026 08:00
Validity period of quotation
90 Day kể từ ngày 03/07/2026 08:00
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
Monitor monitor patients 5 parameters
2
Female
- Year of manufacture: 2025 onwards • DISPLAY: Display: ≥12.1 inch, TFT color touchscreen Resolution: 800x600 Maximum display: ≥13 waveforms Battery: Capacity: ≥2550mAh, operating time ≥4h, charging time ≤3.5h (90%) Printer: 48mm paper width Paper speed: 12.5 mm/s, 25 mm/s, 50 mm/s Printing type: Continuous real-time 8s real-time 20s real-time Wi-Fi: IEEE 802.11b/g/n, Frequency band: 2.4GHz ISM band Data transmission: Data output: Ethernet/USB Data management: Patient care monitoring Central monitoring system: MFM-CMS HIS/EMR connection: HL7 Gateway software MFM-CMS/GW1 • 1. ECG: Modes: 3 leads: I, II, III; 5 leads: I, II, III, aVR, aVL, aVF, V; 6 leads: I, II, III, aVR, aVL, aVF, and feedback leads Va, Vb; 10 leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6; Standards: AHA, IEC; Display sensitivity (adjustable): 1.25 mm/mV (x0.125), 2.5 mm/mV (x0.25), 5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2), 40 mm/mV (x4), auto-adjustment; Scanning speed: 6.25 mm/s, 12.5 mm/s 25 mm/s, 50 mm/s Bandwidth (-3 dB): Diagnosis: 0.05 Hz to 150 Hz Surgery 1: 0.05 Hz to 40 Hz Monitoring: 0.5 Hz to 40 Hz Surgery: 1 Hz to 20 Hz Boost: 2 Hz ~ 18 Hz Adjustment: Low-pass filter and high-pass filter CMRR: Diagnosis: > 95 dB Monitoring: > 105 dB Surgery: > 105 dB Boost: > 105 dB Surgery 1: > 105 dB (when Notch filter is on) Adjustment: > 105 dB (low-pass filter < 40Hz) > 95 dB (low-pass filter > 40Hz) Hum filter: In diagnosis, surgery 1, monitoring, surgery, boost mode: 50Hz/60 Hz (Hum filter can be manually turned on or off) Recovery time after defibrillation: < 5s ESU Protection: Cutting mode: 300 W; Hemostasis mode: 100 W; Recovery time: ≤ 10s Pulse rate of leads One of leads I, II, III, AVR, AVL, AVF, V1, V2, V3, V4, V5, V6 • 2. RESP: Method: Transthoracic impedance: R – F (RA-LL), R – L (RA-LA) Measurement lead: Select lead I and II Measurement range: Adults: 0 rpm to 120 rpm Children/neonatal: 0 rpm to 150 rpm Resolution: 1 rpm Accuracy: Adults: 6 rpm to 120 rpm: ±2 rpm 0 rpm to 5 rpm: not specified Children: 6 rpm to 150 rpm: ±2 rpm 0 rpm to 5 rpm: not specified Adjustment selection: x0.25, x0.5, x1, x2, x3, x4, x5 Scanning speed: 6.25 mm/s, 12.5 mm/s, 25.0 mm/s, 50.0 mm/s Apnea alert time: 10s, 15s, 20s, 25s, 30s, 35s, 40s • 3. NIBP (Non-Invasive Blood Pressure Measurement): Method: Oscillometric Mode: Manual, automatic, continuous Automatic measurement mode in intervals: 1/2/3/4/5/10/15/30/60/90/120/180/240/360/480 minutes Continuous: 5 minutes, interval 5s Measurement type: SYS, DIA, MAP, PR Measurement range: Adult mode: SYS: 25 mmHg to 290 mmHg DIA: 10 mmHg to 250 mmHg MAP: 15 mmHg to 260 mmHg Pediatric mode: SYS: 25 mmHg to 240 mmHg DIA: 10 mmHg to 200 mmHg MAP: 15 mmHg to 215 mmHg Neonatal mode: SYS: 25 mmHg to 140 mmHg DIA: 10 mmHg to 115 mmHg MAP: 15 mmHg to 125 mmHg Cuff pressure measurement range: 0 mmHg to 300 mmHg Pressure resolution: 1 mmHg Maximum mean error: ±5 mmHg Maximum standard deviation: 8 mmHg Maximum measurement time: Adults/children 120s; Neonatal: 90s Typical calculation time: 20s to 35s (based on HR/movement noise) Overpressure protection: Adults: 297 mmHg ±3 mmHg; Children: 245 mmHg ±3 mmHg; Infants: 147 mmHg ±3 mmHg • 4. SpO2 (Peripheral Blood Oxygen Saturation): Measurement Range: 0% to 100% Resolution: 1% Data Update Time: 1s Accuracy: Adults/Children: ±2% (70% to 100% SpO2); Infants: ±3% (70% to 100% SpO2) • 5. Temperature (TEMP) Number of Channels: 2 Sensor Type: YSI-10K and YSI-2.252K Technique: Thermistor Measurement Parameters: T1, T2, TD Location: Skin, mouth, rectum Units: Celsius, Fahrenheit Measurement Range: 0°C to 50°C Resolution: 0.1°C Accuracy: ±0.1°C excluding sensor Sensor accuracy ≤ ±0.2°C Transient response time: ≤ 30s
Unit name: Van Chan Regional Medical Center; Address: Village 9, Thuong Bang La commune, Lao Cai province; Email: [email protected]; Phone number: 02163 873 114
Unconscious
After receiving the winning bid results: Request the contractor to provide the Certificate of Origin, CO, CQ; User manual in Vietnamese (For imported goods)
Approval decision information
Approval date
18/06/2026
Approval decision code
1343/QD-TTYT
Approval decision file

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Purchase additional medical equipment". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Purchase additional medical equipment" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 4

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second