| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Automatic hematological test machine 20 parameters |
1 |
Female |
I. General requirements
Year of production: 2024 onwards
Export: Europe
Machine quality: 100% new
Quality certificate: ISO 13485
Main machine operating environment: Suitable for Vietnam's climate
Source: appropriate use in Vietnam
II.The configuration requirements
1. The main machine comes with a standard set of lawsuits: 01 set
2. Set of accessories and auxiliary equipment: 01 set
Automatic sample picking set: 01 set
Pack chemical testing machine (about 1200 tests): 01 set
Calibrated blood tube: 01 tube
Standard blood tube set: 01 set
Printer results (purchased in Vietnam): 01 piece
Print paper results: 01 file
Set of user manuals + TV: 01 set
III. Technical requirements
Measuring power: ≥ 60 test/hour
Measurement: ≥ 20 parameters
Measuring technology:
The method of antibodies for the WBC and RBC or equivalent
Optical measurement method for HBG or equivalent
Chart: Minimum with RBG, PLT, WBC 3-Part
Sample volume: ≤ 38 µl of all blood
Sample volume: ≤ 2 x 1.4 µl of total blood
Accuracy: WBC <3%, RBC <2%, PLT <5%, MCV <1%, HGB <2%
User interface: LCD, ≥ 10 inches, capacitive touch screen or equivalent
Barcode integration and barcode scan
Connection: Minimum 2 x USB vertical port, Ethernet, LIS (HL7)
Language support: minimum British, French, German, Vietnam, ... |
Yen Khanh Medical Center |
|||
2 |
Respiratory function meter |
1 |
Female |
I. General characteristics- Year of production: from 2024 onwards
- Origin: G7- Machine quality: 100%new- Meeting quality standards: ISO 13485- Source: Suitable use in Vietnam- Main machine operating environment: suitable for Vietnam II. Configuration for each machine-main machine: 01 pcs-paper mouth: 100 pcs- thermal paper: 01 roll- Sensor head: 02 pieces- standard cylinder machine: 01 pcs- power cord: 01 pieces- User manual, English: 01 multiple. Specifications with minimum technical functions:- Can be saved more than ≥ 20,000 checks- can be connected directly to the external printer- with the function of supporting the age estimate of the minimum number of pulmonary numerals:+ Flow resolution: ≤ 0.01 l/s+ Carus range: ≥ ± 18 liters/second+ accuracy of flow: ≤ +/- 5% or ± 0. ≥ ± 10.. FEV1./SVC, FEV1/FEV6, MMEF (FEF25-75), PEF, FEF25, FEF50, FEF75, FEF90, FEF50/FEF75, FEF75-85, FEF200-1200, OI, ATI, PEF TIME, FET, EXTRAPV, ExtracPV%, FIVC, FIV0.5, FIV1, FIV1/FIV1/FIV1/FIV1/FIV1/FIV1/FIV1/FIV1/FIV1/FIV1/FIV1/FIV1/FIV1 FIV1/FIVC, PIF, FIF50, FEF50/FIF50, FIF50/FEF50, CVI, MVV43, FVC+FEV1, MVV, MV, RR, TV, Br, VR, BD Test, Bronchial test |
Yen Khanh Medical Center |
|||
3 |
Vapor pressure massage machine |
2 |
Female |
I. General requirements - Year of manufacture: From 2024 onwards - Machine quality: 100% new - Meets quality standards: ISO 13485 or equivalent - Power supply: Suitable for use in Vietnam - Main machine operating environment: Suitable for Vietnam's climate II. Standard configuration: Main body: 01 unit Power cord: 01 cord 01 pair of lower limb airbags 01 upper limb airbags User manual: 01 set III. Technical parameters 1. Operating mode: digital display, push-button control, easy to use. 2. Weight: Net weight ≤ 4Kg, convenient for medical staff to use at any time 3. Core accessories: Use genuine imported air pumps and high-precision pressure sensors to control pressure and achieve precise pressure stability in the chamber. 4. Number of airbag chambers: 1 upper limb 4-chamber airbag; 1 pair of lower limb airbag, 4-chamber airbag on one side, 8-chamber on both sides, standard equipped with double lower limb airbag (4 chambers), 2 4-chamber airbag can be inflated at the same time, can be selected to treat one limb or two limbs5. Pressure range: 0kPa ~ 27kPa (0mmHg ~ 203mmHg), in 1kPa steps, to achieve precise pressure regulation.6. Pressure adjustment: Using data acquisition technology to quickly determine the pressure value, and using the potentiometer knob to quickly adjust the pressure, easy to operate.7. Zero pressure bypass: In areas with wounds or contraindications to pressure treatment, you can choose to turn off the airbag pressure at that location.8. Treatment time: freely set from 1 minute to 99 minutes, default is 20 minutes when turned on.9. Reminder and warning: equipped with overpressure protection reminder function10. Automatic pressure relief function: When the threshold is reached, the power is suddenly cut off or the treatment is interrupted, the airbag can automatically relieve pressure.11. Safety protection function: Equipped with an emergency function switch, which can perform an emergency stop in an emergency. The emergency switch can be used without installing additional batteries.11. Quiet treatment: The noise when using the device does not exceed 60dB(A).12. Pressure monitoring: Built-in pressure detection module, real-time pressure monitoring under working conditions.13. Automatic alarm: When the device fails, there will be an alarm reminder function. |
Yen Khanh Medical Center |
|||
4 |
Intravascular laser machine |
2 |
Female |
I. General requirements:
- Year of production: From 2024 onwards- Machine quality: 100%new- meeting quality standards: ISO 13485 or equivalent- Supply: suitable use in Vietnam- MAIN MACHINE MACHINE ENVIRONMENT: Suitable for Vietnam Climate
II. Standard configuration:
Standard configuration 01 Machine:- Main machine: 01 pcs- Laser transmitter: 02 pieces- Source wire: 01 pieces- Interior laser needle: 05 pieces- Venous catheter: 05 pieces- Vietnamese ToSD: 01 volume
Iii Number of activities each channel: Yes |
Yen Khanh Medical Center |
|||
5 |
Obstetrics Machine 2 Functions |
1 |
Female |
I. General requirements:
- Year of production: from 2024 onwards
- Origin: G7- Machine quality: 100%new- Meeting quality standards: ISO 13485 or equivalent- Power source: appropriate use in Vietnam- MAIN MACHINE MACHINE MACHINE: Suitable for Vietnamese climate
II. Configuration requirements: 1. The main machine comes with a standard accessory set: 01 unit. The kit of accessories (including standard accessories): 01 set, including:- Matching head (dop/uc) letter Y: 01 pcs- Belt fixed probe: 01 pcs- basket mounted behind the back: 01 pcs- Solar switch for single pregnancy: 01- Marking switch for pregnancy: 01 pcs- Doppler measurement head (for twins): 01 heat printer (integrated on the machine) Vials- Trolley: 01 unit- Source wire: 01 pcs- instructions for use in English + Vietnamese: 01 multiple. Technical requirements: Measuring fetal heart rate FHR:- How to measure FHR: 2-channel Doppler ultrasound system- FHR measurement technique: pulse doppler and automatic correlation processing- FHR counting range: 50- 240 beats/minute- Alarm function: Users select high and low FHR alarm thresholds, and fetal movement time (FM)- FM measurement techniques by Ultrasound System (2 Self-measure Channel)- Printing method: Print graph, print dot Fmo with uterine contractions (UC)- UC measurement method: tension meter- measurement range: 0- 100 units of monitoring FHR- Doppler Sound- Screen: TFT color LCD screen, Touch- Dimensions: ≥7 inches- Display information: CTG (ELECTRIC CONTROL Installation of in-printing methods: Printing method with heat print head (8 dots/ mm)- Print width: 80mm FHR (50-210 BPM) or 70mm (30-240BPM), UC 40 mm- Printing content: year/ month/ hour/ minute, measurement, time label, fetal movement, UC, UC cycle, fetal mark Like VAS, mark the settings for 0 for UC, mark the wrong measurement for FHR- Printing speed: 10mm/ min, 20 mm/ minute, 30mm/ min, 1500mm/ min (for high print speed) or better than battery life- minimum 30 minutes (after full charge) |
Yen Khanh Medical Center |
|||
6 |
Refractor |
1 |
Female |
I. General requirements:
- Year of production: From 2024 onwards- Machine quality: 100%new- Meeting quality standards: ISO 13485 or equivalent- Power source: appropriate use in Vietnam- MACHINE MACHINE MACHINE ENVIRONMENT: Suitable for Vietnam Climate
II. Specifications specifications R/k: Serious refractive measurement Ref: Refractive measurement Ker mode: Measurement of refractive cornea tip (VD): Peak 0, 10, 12.5, 15 mmsph: -25.00- +22.00 d (0.12 d/0.25 d) Cyl: 0.00- +/-10,000DAXIS: 1-180 degrees Dong Tu: 10-85 mm minimum diameter of the pupil: Ø 2.0 corneal. |
Yen Khanh Medical Center |
|||
7 |
Eye examination machine |
1 |
Female |
I. General requirements:
- Year of production: from 2024 onwards
- Origin: G7- Machine Quality: 100%New- Meet Quality Standards: ISO 13485- Source: Suitable use in Vietnam- MAIN MACHINE MACHINE ENVIRONMENT: Suitable for Vietnam Climate
II. Figure:- Main machine with standard accessories: 01 pcs- Price of chin: 01 pcs- Paper chin paper: 01 file- covering dust: 01 pieces- Automatic lifting legs: 01 pieces- Instructions for using English + Vietnamese: 01 multiple II close): 10x (20, 13mm); 16x (16, 13mm); Adjust the distance of the pupils: 52 -90mm of convergence: 100mm adjusting to the ride: +8 to -8DS Lighting of the slot light: The width of the light slot (mm): 0 -10mm The degree (mm): 0.2, 1, 3, 4, 6, 10mm long slot slot: 0 -10mm Rotating slot light slot: ± 900 filter filter ND Tilting the slot of light: 50, 100,150,200 Sumon: Maximum bright light bulb: 45,000 Lux: Horizontal movement: 30mmdi vertical: 79mm.Di on the side: 115mm Movement: ± 10mm Foot color: Can choose the chin color: Vertical movement vertical: 75mm Fixed target |
Yen Khanh Medical Center |
|||
8 |
Monitor monitor monitor patients 5 parameters |
1 |
Female |
I. General requirements; - Year of manufacture: From 2024 onwards - Machine quality: 100% new - Meets quality standards: ISO 13485 - Supply source: Suitable for use in Vietnam - Main machine operating environment: Suitable for Vietnam's climate II. Configuration includes: Main machine with touch screen ≥12.1 inches: 01 piece Accessories: - Reusable ECG cable (5-electrode type): 01 piece - Reusable adult SPO2 sensor: 01 piece - SPO2 extension cable: 01 piece - Adult blood pressure cuff and extension tube: 01 piece - Reusable temperature sensor: 01 piece - Built-in rechargeable battery: 01 piece - Thermal printer: 01 set - Power adapter: 01 piece - User manual in English and Vietnamese - Monitor trolley (made in Vietnam): 01 piece. III. Technical features: - Compact design with a thickness of 65mm, convenient and smart.- System startup time: About 1 second.- TFT color touch screen ≥12.1 inches.- Resolution: Minimum 800 x 600- Extremely low power consumption.- Fanless design so no noise.- Automatic screen brightness adjustment.- Accurate ECG measurement with anti-vibration mode.- ST wave analysis, and detection of 16 different types of arrhythmias.- Extremely accurate SpO2 performance even with movement and low blood flow.- USB port support for easy software upgrades and data transfer.- Intelligent pressure adjustment software and NIBP pump pressure protection hardware.- Protection against data loss when power is suddenly lost.- With smart hanging arm, the machine can be placed in many positions.- 7-lead ECG display mode, large-size text display, CRC Oxygen.- Continuous working time up to up to 5 hours with built-in battery.- DC 12 ~ 15V input suitable for placing on ambulance.- Ability to connect to central monitoring system.- HL7 extract clinical information system data.- Suitable for adults, children, infants.- Indicators: Power indicator, battery indicator- Rechargeable Li-ion battery. Battery capacity ≥4400 mAh - Continuous battery usage time: 5 hours.- Data import and export: o LAN port, RJ45 standard port. o USB port for data import and export. o Nurse call connection. Monitoring parameters: ECG parameters: - 3 electrode wires: 3/5 leads. - Optional gain: 0.125, 0.25, 0.5, 1, 2, automatic - Scanning speed: 12.5mm/s, 25mm/s, 50mm/s. - Filter: o Dignostic mode: 0.05-130Hz. o Monitoring mode: 0.5 - 40 Hz. o Surgical mode: 1 - 25 Hz. o Strong mode: 5 - 20 Hz. o Frequency: 50Hz, 60 Hz.- Heart rate range o Adults 15 ~ 300 beats/minuteo Children/infants: 15 ~ 350 beats/minuteo Accuracy: ±1 beat/minuteRespiratory parameters.- Measurement method: Transthoracic impedance- Operation mode: Automatic- Measurement range: 0~ 120 times/minute.- Apnea alarm time: 20, 25, 30, 35, 40, 45, 50, 55, 60 seconds.- Bandwidth: 0.3 to 2Hz (- 3dB)- Scanning speed: 6.25 mm/second, 12.5 mm/second, 25mm/second.SpO2 parameters.- Measurement range: 0 ~ 100%- Resolution: 1%.- Accuracy:o Adults, children: ±2% (70 ~ 100%)o Newborn: ±3% (70 ~ 100%)- Perfusion index: 0.05% ~ 20%- Refresh time: 1 second.- Scanning speed: 12.5 mm/sec, 25mm/sec.Heart rate parameters:- Measuring range: 25 ~ 250 beats/min.- Resolution: 1 beat/min.- Accuracy: ± 2%NIBP (Non-invasive blood pressure) parameters- Method: Automatic oscillation- Modes: Manual/Auto/Continuous.- Measuring unit: mmHg or kPa optional- Measuring type: Systolic, diastolic, average.- Measuring range:o Systolic blood pressure range:§ Adults: 40 ~ 270 mmHg§ Children: 40 ~ 200 mmHg§ Newborn: 40 ~ 130 mmHg.o Diastolic blood pressure range:§ Adult: 10 ~ 210 mmHg§ Child: 10 ~ 160 mmHg§ Infant: 10 ~ 90 mmHgo Average blood pressure range§ Adult: 20 ~ 230 mmHg§ Child: 20 ~ 175 mmHg§ Infant: 20 ~ 100 mmHgo Accuracy: Maximum: ±5mmHg- Overpressure protection: 2-layer protection.- Resolution: 1 mmHgTemperature parameters- Measuring range: 0 ~ 500C.- Accuracy: ± 0.10 or ±0.20F- Monitoring channels: 2 channels.- Resolution: 0.10C.- Measuring parameters: T1, T2 and TD Thermal printer - Type: Thermal printing- Printing speed: 12.5, 25, 50 mm/s- Roll paper size: 58 mm (width) x 42m (length) |
Yen Khanh Medical Center |
|||
9 |
Electrocardiogram |
1 |
Female |
I. General requirements: - Year of manufacture: From 2024 onwards - Machine quality: 100% new - Meets quality standards: ISO 13485 - Power supply: Suitable for use in Vietnam - Main machine operating environment: Suitable for Vietnam's climate II. Configuration: - Main machine: 01 unit - Patient connection cable: 01 unit - Limb clamp electrode: 01 set (04 units) - Chest electrode: 01 set (06 units) - Power cord: 01 unit - Rechargeable battery: 01 unit - Recording paper: 01 roll - Thermal head cleaning pen: 01 unit - User manual and CD: 01 set III. Technical characteristics: 1. MAIN FEATURES Designed to ensure Diagnostic quality, Examination quality anywhere, 2. TECHNICAL SPECIFICATIONS: * Electrocardiogram signal collection: - Resistance Input: ≥ 50MW (at 0.67 Hz)- Offset voltage: ≥ ± 550mV- Input circuit: Isolated and protected to avoid electrocardiographic shock- Noise filtering coefficient: ≥105dB (at 10V)- Input current: ≤ 0.05µA- Sensitivity: 10mm/mv ± 2%- Internal noise: ≤ 20µVp-v- Interference between channels: ≤ -40dB- Frequency response: with 10Hz, 0.05-150Hz (+0.4dB/-3dB). 150 Hz (≥71%, high-pass filter: 150Hz)- Sampling rate: 8000 samples/sec* Signal processing:- Analysis sampling rate: 500 samples/sec, 1.25µv/LSB- Minimum signal response: 20µVp-v- Electromechanical noise filter: 25/35 Hz- High-pass filter: 75, 100, 150 Hz (≥3 dB)- AC noise filter: 50/60Hz- Baseline anti-drift filter: Weak: -20dB (0.1Hz), Strong: -34dB (0.1Hz)- Time constant: ≥ 3.2s- Sensitivity: 5, 10, 20mm/mV* Display:- Screen size: ≥5.0 inch- Type: TFT color LCD screen (with backlight) background)- Resolution: Minimum 800 x 480 dots- Display parameters: waveform, patient information, recording mode settings, operating mode, heart rate, QRS synchronization mark, Error message, electrode contact, noise* Recording:- Print density: Minimum 200dpi (8 dots/mm)- Scan density: 1ms- Number of recording channels: 1, 1 + beat, or 3- Paper speed: 25, 50 mm/s - Recording parameters: ECG waveform, heart rate, version, recording program type, date and time, paper speed, sensitivity, lead name, Filter, patient information, event marker, electrode slip, noise- Paper size: 63 mm wide, 30m long in roll- Mechanical noise: ≤ 48 dB at 25 mm/s paper speed* ECG analysis:- Program name: ECAPS 12C- Patient age: from birth to adult- ECG result finding item: nearly 200- Result analysis item: 5* Power supply requirements:- Voltage: AC (100V to 240V) ± 10%;- Frequency: 50/ 60 Hz- Input power: ≤ 45 VA- Battery: Rechargeable, ≥1600 mAh- Battery usage time: More than 180 minutes (under conditions: automatic recording every 3 minutes with new battery, at 25oC) About 60 minutes (continuous recording with new battery, at 25oC) - Charging time: within 3 hours* Communication port: - USB type A port: 2- LAN port: 1* Wireless LAN connection:- Apply wireless LAN standard: IEEE 802.11 a/b/g/n/ac* Operating environment: Storage and transportation environment- Temperature Main unit: -20 - 650CRecording paper: 0 - 450CBackup battery: -20 - 650C (less than 1 week) -20 - 550C (less than 1 month) -20 - 450C (less than 6 months) -20 - 350C (less than 1 year)- Humidity: Main unit: 10 - 95% (no condensation)Recording paper: 40 - 80% (no condensation)Backup battery: 10 - 95% (no condensation) (less than 2 months)45 - 85% (no condensation) (more than 2 months)- Environmental pressure: 700 to 1060 hPaOperating environment:- Temperature: 5 to 40°C- Relative humidity: Main unit: 25 to 95% (no condensation)Battery: 40 to 85% (no condensation) mist)- Operating environment pressure: 700 to 1060 hPa* Dimensions, weight:- Volume: Not required (Approximately W260 x H75 x D172mm ± 10%). - Weight: Main unit: Not required (approximately 1.1kg, without recording paper and power adapter)* Safety standards:Standard: IEC60601-1:2012, IEC60601-2-25:2011 IEC60601-1-2:2014* Type of protection against electric shock. AC power supply: class 1 device Battery power supply: internal power supply device Degree of protection against electric shock: - Defibrillator protection type CF, applicable on patient cables: BJ-961D, BJ-962D, BJ-901D, BJ-902D, BJ-903D, BA-901D or equivalent. Degree of protection against water: IPX0 (unprotected) Degree of safety of application in the presence of flammable anesthetic mixtures with air, oxygen or nitrous oxide: not suitable for use in the presence of such mixtures. Mode of operation: continuous |
Yen Khanh Medical Center |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Trung tâm Y tế Yên Khánh:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Trung tâm Y tế Yên Khánh:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.