| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Chemicals to quantify HBA1C in blood |
30 |
Box |
Reagent form: Prepackaged liquid.
Application: To quantitatively determine total Hemoglobin A1c (HbA1c).
blood supports the diagnosis and treatment of diabetes. HbA1c value provides an indication of blood sugar control in patients
have diabetes and indicate glucose levels compared to 4-8 weeks ago.
Active concentration:
R1:
Buffer, pH 7.0 100 mmol/L.
Proteases 4 KU/mL.
Triton-X 100 0.5 %.
Redox agents > 10 µmol/L.
R2:
FVO enzyme > 10 U/mL.
POD 90 U/mL.
Chromogen 0.8 mmol/L.
Haemolysis Reagent:
CHES buffer, pH 8.7 100 mmol/L.
Triton-X 100 1 %.
SDS 0.45 %.
Redox agents 0.5 mmol/L.
Measuring range: ≤15 %.
Storage: 2-8°C.
Compatible: Use with all open system biochemical testing machines. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
1 x 30 mL + 1 x 10 mL + H: 2 x 80 mL |
Can be used on Miura biochemical testing machine |
|
2 |
Chemical to determine Alkaline phosphatase in blood |
7 |
Box |
The reagent is intended for the in vitro qualitative determination of condensed alkaline phosphatase in human serum and plasma.
Specification:
- Reagent 1: 4 vials x 40.5ml liquid reagent
- Reagent 2: 4 vials x 10.5ml liquid reagent
Condensation:
- Reagent A: Diethanolamine pH 9.8: 1.2 mol/L; Magnesium Chloride: 0.6 mmol/L
- Reagent B: p-nitrophenylphospahte: 50 mmol/L
Method:
- Name: Kinetic substrate
- Unit: UI/I
- Filter F1: 405nm
- R1 capacity: 200 µL
- Sample capacity: 4 µL
- Incubation time R1,S ->R2: 4 seconds
- R2 capacity: 50 µL
- Final incubation time: 60 seconds
- Kinematic reading time: 192 seconds
Normal value; Serum or plasma; For adults:
- At temperature 25°C: <170 UI/I
- At 30°C: <211 UI/I
- At temperature 37°C: <258 UI/I |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
4x40.5ml + 4x10.5ml |
Can be used on Muira and KHB Polaris c1000 biochemical testing machines |
|
3 |
Magnesium quantitative chemicals |
15 |
Box |
Reagent form: Prepackaged liquid.
Application: For quantitative determination of Magnesium in serum, heparinized
Plasma and urine aid in diagnosis and treatment
Hypomagnesemia is observed in cases of diabetes, alcoholism, diuretics, hyperthyroidism, hypothyroidism, malabsorption, myocardial infarction, cirrhosis and hypermagnesemia is observed in cases of renal failure, diabetic acidosis, Addison's disease, vitamin D poisoning.
Active concentration:
R:
Good's buffer 175.0 mmol/L
Xylidyl blue 0.12 mmo/L
Potassium carbonate 60.0 mmol/L
EGTA 0.04 mmol/L
Measuring range: ≤10 mg/dL.
Storage: 15 - 25°C.
Compatible: Use with all open system biochemical testing machines. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
6 x 25 ml |
Can be used on Muira and KHB Polaris c1001 biochemical testing machines |
|
4 |
Balancing agent, electrolyte electrode activation |
5 |
Box |
For HY-LYTE 300 series electrolyte analyzers Used to activate new electrodes.
Code: ASR5014-00
Capacity: 1x50ml
Ingredients: ionic, non-ionic surfactants.
On the chemical bottle there is a barcode to identify the chemical. Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
1x50ml |
Can be used on AS 930 electrolyte testing machine |
|
5 |
Low level internal quality control substance HBA1C |
4 |
Jar |
HBA1C Control Low Used to check Hba1C quality at low values. Extracted from whole human blood with established high pathological values
Capacity: R: 1x0.5 ml
Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
1x0.5 ml |
Can be used on Miura biochemical testing machine |
|
6 |
Internal quality control agent with 2 levels HBA1C |
2 |
Box |
Reagent form: Lyophilized powder.
Application: Control agent HBA1c is a two-level control agent for quality
HBA1c test control process on clinical chemistry analyzer.
Active concentration: Hemolysate prepared from packed human red blood cells,
freeze-dried and stable.
Storage: 2-8°C.
Compatible: Use with all open system biochemical testing machines. Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
1 x 0.5 mL + 1 x 0.5 mL |
Can be used on Miura biochemical testing machine |
|
7 |
Multi-parameter internal control agent for cardiovascular testing |
3 |
Box |
Code: 691027
Multi Control Cardiac Marker is an immunoassay quality control serum used for in vitro quantification of Troponin I (cTnI), Myoglobin (MYO), Creatine Kinase MB (CK-MB), N-terminal pro B-type Natriuretic Peptide (NT-proBNP) and MYO STAT, CK-MB STAT, NT-proBNP STAT in Lifotronic standards and supporting reagents using a fully automated immunoanalyzer for testing. Control the quality of the respective standards during the detection process.
Active ingredients:
The product set is lyophilized horse serum products containing natural troponin (cTnI), recombinant myoglobin, natural creatine kinase MB (CK-MB), recombinant N-terminal pro B-type natriuretic peptide (NT-proBNP). Target values and ranges for batches are encoded in the quality control tag. Necessary supporting tools and materials not provided in this package (provided by Lifotronic)
Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2~8℃ for 12 months. 2After reconstitution at 2~8℃ for 7 days. -25 ~ -15 ℃: 3 months |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
Box
(Low level: 3 × 2 mL+ High level: 3× 2 mL) |
Can be used on eCL8000 immunoassay machine |
|
8 |
HBA1C calibration |
1 |
Box |
Reagent form: Lyophilized powder.
Application: HBA1c calibrator is a four-level calibration blood for calibrating the test method for determining HbA1c from whole blood on clinical biochemistry analyzers.
Active concentration: Hemolysate prepared from packed human red blood cells,
freeze-dried and stable.
Storage: 2-8°C.
Compatible: Use with all open system biochemical testing machines.
Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
4 x 0.5 ml |
Can be used on Miura biochemical testing machine |
|
9 |
CRP HS quantitative test calibrator |
4 |
Box |
CRP HS quantitative test calibrator. Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
1x1ml |
Can be used on Muira and KHB Polaris c1000 biochemical testing machines |
|
10 |
CRP HS quantitative test control material |
12 |
Box |
CRP HS quantitative test control material. Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
2x1ml |
Can be used on Muira and KHB Polaris c1000 biochemical testing machines |
|
11 |
Pancreatic and biliary tract cancer testing |
400 |
kiểm TRA |
Carbohydrate Antigen 19-9 is an immunoassay reagent for in vitro
Quantitative determination of Carbohydrate Antigen 19-9 (CA19-9) in humans
serum or plasma with a fully automated immunoassay analyzer that monitors the treatment effects of pancreatic and biliary tract malignancies.
Active ingredients:
MB: Streptavidin coated magnetic particles, 0.45 mg/mL; 0.1 M phosphate-buffered
saline (PBS); ProClin300.
RB: Biotinylated CA19-9 antibody, 3.0 mg/L; 50 mM HEPES; ProClin300.
RA: Ru complex-labeled CA19-9 antibody, 1.5 mg/L; 50 mM HEPES; ProClin300.
Calibrator: CA19-9 antigen, 100 mM PBS pH7.4, ProClin 300.
Control Material (Optional): CA19-9 antigen, 100 mM PBS pH7.4, ProClin 300.
Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2~8℃ for 18 months. 56 days in the machine.
Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
50 test |
Can be used on eCL8000 immunoassay machine |
|
12 |
Total β-HCG quantitative testing reagent |
200 |
kiểm TRA |
Total Beta Human Chorionic Gonadotropin Is an Immunoassay Reagent for the quantitative in vitro determination of total human beta
chorionic gonadotropin (Total β-HCG) in human serum and plasma by automated immunoassay analyzer to aid in the diagnosis of pregnancy and
pregnancy-related complications.
Active ingredients:
(MB): Microparticle-coated streptavidin, 0.75mg/mL; 0.1 million PBS; 0.05% ProClin™ 300.
(RA): Anti-β-HCG-Ab ~ Ru (bpy) 3 2+, 1mg/L; 0.1 million PBS; 0.05% ProClin™ 300
(RB): Anti-β-HCG-Ab ~ biotin, 3 mg/L; 0.1 M PBS; 0.05% ProClin™ 300.
Sample Diluent: 0.1M PBS; 1% BSA;
0.05 % ProClin™ 300.
Calibration (High): 50 mM Tris; 0.05%
ProClinTM300.
Calibration (Low): 50 mM Tris; 0.05%
ProClinTM300.
Control (High): 50 mM Tris; 0.05%
ProClinTM300.
Control (low): 50 mM Tris; 0.05%
ProClinTM300.
Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2~8℃ for 12 months. 28 days in machine (temperature 4~15℃) |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
100 test |
Can be used on eCL8000 immunoassay machine |
|
13 |
Cardiovascular disease testing |
800 |
kiểm TRA |
Troponin I is an in vitro immunoassay reagent for the quantitative determination of cardiac troponin I in human serum and plasma. This test is intended to aid in the diagnosis of myocardial infarction.
Active ingredients:
MB: Streptavidin-coated micro magnetic beads 0.75mg/mL: 0.1 M PBS; 0.05%
ProClin™ 300.
RB: Anti-cTnI-Ab~biotin 0.8 mg/L: 0.05 M MES buffer; 0.05% ProClin™ 300.
RA: Anti-cTnI-Ab~Ru(bpy) 3 2+ 0.63 mg/L: 0.05 M MES buffer; 0.05% ProClin™
300.
Calibration (High): Equine serum, 0.05% ProClin™ 300.
Calibration (Low): Equine serum, 0.05% ProClin™ 300.
Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2~8℃ for 12 months. 28 days in the machine.
Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
100 test |
Can be used on eCL8001 immunoassay machine |
|
14 |
Test folic acid concentration in blood |
600 |
kiểm TRA |
Folate is an immunoassay reagent for the in vitro quantitative determination of folate in human serum, aiding in the diagnosis of disorders associated with folate deficiency.
Active ingredients:
PT2: Sodium 2-mercaptoethanesulfonate (MESNA).
PT3: Sodium Hydroxide.
MB: Streptavidin-coated microparticles, 0.75 mg/mL; PBS; ProClin300.
RB: Biotinylated folate coupled BSA, 0.6 mg/L; HEPES; preservative.
RA: Ru complex-labeled folate binding protein, 0.3 mg/L; HEPES; preservative.
Folate Calibrator: folate antigen; horse serum; Folate preservative.
Control Material: folate antigen; horse serum; Folate preservative.
Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2~8℃ for 12 months. 28 days in the machine. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
100 test |
Can be used on eCL8002 immunoassay machine |
|
15 |
Anemia Test |
900 |
kiểm TRA |
Ferritin is an immunoassay reagent for the in vitro quantification of Ferritin in human serum and plasma to aid in the diagnosis of diseases related to iron metabolism, such as hemochromatosis and iron deficiency anemia.
Active ingredients:
MB: Streptavidin-coate d microparticles, preservative.
RB: Anti-Ferritin~biot in, PBS, preservative.
RA: Anti-Ferritin~Ru (bpy) 3 2+, PBS, preservative.
Calibrator (High): bovine serum, preservative; freeze dried.
Calibrator (Low): bovine serum, preservative.
Control (High): bovine serum, preservative.
Control (Low): bovine serum, preservative.
Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2~8℃ for 12 months. 28 days in the machine. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
100 test |
Can be used on eCL8003 immunoassay machine |
|
16 |
Insulin testing |
400 |
kiểm TRA |
Insulin is an in vitro immunoassay reagent for the quantitative determination of insulin in human serum and plasma.
Active ingredients:
MB: Streptavidin-coated bacteria magnetic beads; preservatives.
RB: Anti-Insulin-Ab~biotin: 50 MES; preservatives.
RA: Anti-Insulin-Ab~Ru(bpy) 3 2+ : MES 50 mM; preservatives.
Calibrator (High): bovine serum, preservative; freeze dried.
Calibrator (Low): bovine serum, preservative; freeze dried.
Control (High): bovine serum, preservative; freeze dried.
Control (Low): bovine serum, preservative; freeze dried.
Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2~8℃ for 12 months. 28 days in the machine.
Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
100 test |
Can be used on eCL8004 immunoassay machine |
|
17 |
Vitamin D test |
400 |
kiểm TRA |
25-OH Vitamin D Total is an immunoassay reagent for the in vitro quantification of total 25-hydroxy Vitamin D in human serum and plasma. Results can be used to aid in the diagnosis of Vitamin D adequacy.
Active ingredients:
PT2 1.4% Dithiothreitol
PT3 0.25M Sodium Hydroxide
MB: Streptavidin-coated microparticles, 0.75 mg/mL: 0.1M
PBS; 0.05% ProClin™ 300
RB: 25-OH vitamin D~ Biotin: 0.05M MES; 0.05% ProClin™ 300
RA: Anti-vitamin D ~Ru(bpy) 2+ 3: 0.05M BIS-Tris; 0.05% ProClin™ 300
Calibrator(High): Horse serum, 0.05% ProClin™ 300; lyophilized
Calibrator(Low): Horse serum, 0.05% ProClin™ 300; lyophilized
Control Material (High): Horse serum, 0.05% ProClin™ 300; lyophilized.
Control Material (Low): Horse serum, 0.05% ProClin™ 300; lyophilized
Compatible devices: Compatible devices: eCL8000, eCL8000i, eCL8000p,
eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i.
Storage: 2 ~ 8 ℃ for 18 months, 8 weeks in the machine.
Meets standards: ISO 13485:2016. |
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province |
100 test |
Can be used on eCL8005 immunoassay machine |
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor BỆNH VIỆN ĐA KHOA TRẦN LÃM:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding BỆNH VIỆN ĐA KHOA TRẦN LÃM:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.