Test chemicals

Find: 16:58 20/11/2025

Bid info

Project name/purchase estimate
BUY CHEMICALS, TESTING SUPPLIES - GENERAL CHEMICALS - BIOLOGICAL PRODUCTS - MEDICAL GAS IN 2025-2026
Bid name
BUY CHEMICALS, TESTING SUPPLIES - GENERAL CHEMICALS - BIOLOGICAL PRODUCTS - MEDICAL GAS IN 2025-2026

Basic information of the request for quotation

Request for quotation code
RQ2500021959-00
Status
Posted
Name of request for quotation
Test chemicals
Unit requesting quote
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
No. 355, Tran Lam Street, Phường Trần Lãm, Province Hưng Yên
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Bùi Duy Duyn
Position
Dean of Pharmacy
Phone number
Address
No. 355 Tran Lam Street, Tran Hiep Ward, Hung Yen Province

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 20/11/2025 16:56 To date 30/11/2025 17:00
Validity period of quotation
120 Day kể từ ngày 30/11/2025 17:00
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
Chemicals to quantify HBA1C in blood
30
Box
Reagent form: Prepackaged liquid. Application: To quantitatively determine total Hemoglobin A1c (HbA1c). blood supports the diagnosis and treatment of diabetes. HbA1c value provides an indication of blood sugar control in patients have diabetes and indicate glucose levels compared to 4-8 weeks ago. Active concentration: R1: Buffer, pH 7.0 100 mmol/L. Proteases 4 KU/mL. Triton-X 100 0.5 %. Redox agents > 10 µmol/L. R2: FVO enzyme > 10 U/mL. POD 90 U/mL. Chromogen 0.8 mmol/L. Haemolysis Reagent: CHES buffer, pH 8.7 100 mmol/L. Triton-X 100 1 %. SDS 0.45 %. Redox agents 0.5 mmol/L. Measuring range: ≤15 %. Storage: 2-8°C. Compatible: Use with all open system biochemical testing machines.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
1 x 30 mL + 1 x 10 mL + H: 2 x 80 mL
Can be used on Miura biochemical testing machine
2
Chemical to determine Alkaline phosphatase in blood
7
Box
The reagent is intended for the in vitro qualitative determination of condensed alkaline phosphatase in human serum and plasma. Specification: - Reagent 1: 4 vials x 40.5ml liquid reagent - Reagent 2: 4 vials x 10.5ml liquid reagent Condensation: - Reagent A: Diethanolamine pH 9.8: 1.2 mol/L; Magnesium Chloride: 0.6 mmol/L - Reagent B: p-nitrophenylphospahte: 50 mmol/L Method: - Name: Kinetic substrate - Unit: UI/I - Filter F1: 405nm - R1 capacity: 200 µL - Sample capacity: 4 µL - Incubation time R1,S ->R2: 4 seconds - R2 capacity: 50 µL - Final incubation time: 60 seconds - Kinematic reading time: 192 seconds Normal value; Serum or plasma; For adults: - At temperature 25°C: <170 UI/I - At 30°C: <211 UI/I - At temperature 37°C: <258 UI/I
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
4x40.5ml + 4x10.5ml
Can be used on Muira and KHB Polaris c1000 biochemical testing machines
3
Magnesium quantitative chemicals
15
Box
Reagent form: Prepackaged liquid. Application: For quantitative determination of Magnesium in serum, heparinized Plasma and urine aid in diagnosis and treatment Hypomagnesemia is observed in cases of diabetes, alcoholism, diuretics, hyperthyroidism, hypothyroidism, malabsorption, myocardial infarction, cirrhosis and hypermagnesemia is observed in cases of renal failure, diabetic acidosis, Addison's disease, vitamin D poisoning. Active concentration: R: Good's buffer 175.0 mmol/L Xylidyl blue 0.12 mmo/L Potassium carbonate 60.0 mmol/L EGTA 0.04 mmol/L Measuring range: ≤10 mg/dL. Storage: 15 - 25°C. Compatible: Use with all open system biochemical testing machines.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
6 x 25 ml
Can be used on Muira and KHB Polaris c1001 biochemical testing machines
4
Balancing agent, electrolyte electrode activation
5
Box
For HY-LYTE 300 series electrolyte analyzers Used to activate new electrodes. Code: ASR5014-00 Capacity: 1x50ml Ingredients: ionic, non-ionic surfactants. On the chemical bottle there is a barcode to identify the chemical. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
1x50ml
Can be used on AS 930 electrolyte testing machine
5
Low level internal quality control substance HBA1C
4
Jar
HBA1C Control Low Used to check Hba1C quality at low values. Extracted from whole human blood with established high pathological values Capacity: R: 1x0.5 ml Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
1x0.5 ml
Can be used on Miura biochemical testing machine
6
Internal quality control agent with 2 levels HBA1C
2
Box
Reagent form: Lyophilized powder. Application: Control agent HBA1c is a two-level control agent for quality HBA1c test control process on clinical chemistry analyzer. Active concentration: Hemolysate prepared from packed human red blood cells, freeze-dried and stable. Storage: 2-8°C. Compatible: Use with all open system biochemical testing machines. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
1 x 0.5 mL + 1 x 0.5 mL
Can be used on Miura biochemical testing machine
7
Multi-parameter internal control agent for cardiovascular testing
3
Box
Code: 691027 Multi Control Cardiac Marker is an immunoassay quality control serum used for in vitro quantification of Troponin I (cTnI), Myoglobin (MYO), Creatine Kinase MB (CK-MB), N-terminal pro B-type Natriuretic Peptide (NT-proBNP) and MYO STAT, CK-MB STAT, NT-proBNP STAT in Lifotronic standards and supporting reagents using a fully automated immunoanalyzer for testing. Control the quality of the respective standards during the detection process. Active ingredients: The product set is lyophilized horse serum products containing natural troponin (cTnI), recombinant myoglobin, natural creatine kinase MB (CK-MB), recombinant N-terminal pro B-type natriuretic peptide (NT-proBNP). Target values ​​and ranges for batches are encoded in the quality control tag. Necessary supporting tools and materials not provided in this package (provided by Lifotronic) Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 2After reconstitution at 2~8℃ for 7 days. -25 ~ -15 ℃: 3 months
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
Box (Low level: 3 × 2 mL+ High level: 3× 2 mL)
Can be used on eCL8000 immunoassay machine
8
HBA1C calibration
1
Box
Reagent form: Lyophilized powder. Application: HBA1c calibrator is a four-level calibration blood for calibrating the test method for determining HbA1c from whole blood on clinical biochemistry analyzers. Active concentration: Hemolysate prepared from packed human red blood cells, freeze-dried and stable. Storage: 2-8°C. Compatible: Use with all open system biochemical testing machines. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
4 x 0.5 ml
Can be used on Miura biochemical testing machine
9
CRP HS quantitative test calibrator
4
Box
CRP HS quantitative test calibrator. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
1x1ml
Can be used on Muira and KHB Polaris c1000 biochemical testing machines
10
CRP HS quantitative test control material
12
Box
CRP HS quantitative test control material. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
2x1ml
Can be used on Muira and KHB Polaris c1000 biochemical testing machines
11
Pancreatic and biliary tract cancer testing
400
kiểm TRA
Carbohydrate Antigen 19-9 is an immunoassay reagent for in vitro Quantitative determination of Carbohydrate Antigen 19-9 (CA19-9) in humans serum or plasma with a fully automated immunoassay analyzer that monitors the treatment effects of pancreatic and biliary tract malignancies. Active ingredients: MB: Streptavidin coated magnetic particles, 0.45 mg/mL; 0.1 M phosphate-buffered saline (PBS); ProClin300. RB: Biotinylated CA19-9 antibody, 3.0 mg/L; 50 mM HEPES; ProClin300. RA: Ru complex-labeled CA19-9 antibody, 1.5 mg/L; 50 mM HEPES; ProClin300. Calibrator: CA19-9 antigen, 100 mM PBS pH7.4, ProClin 300. Control Material (Optional): CA19-9 antigen, 100 mM PBS pH7.4, ProClin 300. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 18 months. 56 days in the machine. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
50 test
Can be used on eCL8000 immunoassay machine
12
Total β-HCG quantitative testing reagent
200
kiểm TRA
Total Beta Human Chorionic Gonadotropin Is an Immunoassay Reagent for the quantitative in vitro determination of total human beta chorionic gonadotropin (Total β-HCG) in human serum and plasma by automated immunoassay analyzer to aid in the diagnosis of pregnancy and pregnancy-related complications. Active ingredients: (MB): Microparticle-coated streptavidin, 0.75mg/mL; 0.1 million PBS; 0.05% ProClin™ 300. (RA): Anti-β-HCG-Ab ~ Ru (bpy) 3 2+, 1mg/L; 0.1 million PBS; 0.05% ProClin™ 300 (RB): Anti-β-HCG-Ab ~ biotin, 3 mg/L; 0.1 M PBS; 0.05% ProClin™ 300. Sample Diluent: 0.1M PBS; 1% BSA; 0.05 % ProClin™ 300. Calibration (High): 50 mM Tris; 0.05% ProClinTM300. Calibration (Low): 50 mM Tris; 0.05% ProClinTM300. Control (High): 50 mM Tris; 0.05% ProClinTM300. Control (low): 50 mM Tris; 0.05% ProClinTM300. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in machine (temperature 4~15℃)
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
100 test
Can be used on eCL8000 immunoassay machine
13
Cardiovascular disease testing
800
kiểm TRA
Troponin I is an in vitro immunoassay reagent for the quantitative determination of cardiac troponin I in human serum and plasma. This test is intended to aid in the diagnosis of myocardial infarction. Active ingredients: MB: Streptavidin-coated micro magnetic beads 0.75mg/mL: 0.1 M PBS; 0.05% ProClin™ 300. RB: Anti-cTnI-Ab~biotin 0.8 mg/L: 0.05 M MES buffer; 0.05% ProClin™ 300. RA: Anti-cTnI-Ab~Ru(bpy) 3 2+ 0.63 mg/L: 0.05 M MES buffer; 0.05% ProClin™ 300. Calibration (High): Equine serum, 0.05% ProClin™ 300. Calibration (Low): Equine serum, 0.05% ProClin™ 300. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in the machine. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
100 test
Can be used on eCL8001 immunoassay machine
14
Test folic acid concentration in blood
600
kiểm TRA
Folate is an immunoassay reagent for the in vitro quantitative determination of folate in human serum, aiding in the diagnosis of disorders associated with folate deficiency. Active ingredients: PT2: Sodium 2-mercaptoethanesulfonate (MESNA). PT3: Sodium Hydroxide. MB: Streptavidin-coated microparticles, 0.75 mg/mL; PBS; ProClin300. RB: Biotinylated folate coupled BSA, 0.6 mg/L; HEPES; preservative. RA: Ru complex-labeled folate binding protein, 0.3 mg/L; HEPES; preservative. Folate Calibrator: folate antigen; horse serum; Folate preservative. Control Material: folate antigen; horse serum; Folate preservative. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in the machine.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
100 test
Can be used on eCL8002 immunoassay machine
15
Anemia Test
900
kiểm TRA
Ferritin is an immunoassay reagent for the in vitro quantification of Ferritin in human serum and plasma to aid in the diagnosis of diseases related to iron metabolism, such as hemochromatosis and iron deficiency anemia. Active ingredients: MB: Streptavidin-coate d microparticles, preservative. RB: Anti-Ferritin~biot in, PBS, preservative. RA: Anti-Ferritin~Ru (bpy) 3 2+, PBS, preservative. Calibrator (High): bovine serum, preservative; freeze dried. Calibrator (Low): bovine serum, preservative. Control (High): bovine serum, preservative. Control (Low): bovine serum, preservative. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in the machine.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
100 test
Can be used on eCL8003 immunoassay machine
16
Insulin testing
400
kiểm TRA
Insulin is an in vitro immunoassay reagent for the quantitative determination of insulin in human serum and plasma. Active ingredients: MB: Streptavidin-coated bacteria magnetic beads; preservatives. RB: Anti-Insulin-Ab~biotin: 50 MES; preservatives. RA: Anti-Insulin-Ab~Ru(bpy) 3 2+ : MES 50 mM; preservatives. Calibrator (High): bovine serum, preservative; freeze dried. Calibrator (Low): bovine serum, preservative; freeze dried. Control (High): bovine serum, preservative; freeze dried. Control (Low): bovine serum, preservative; freeze dried. Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2~8℃ for 12 months. 28 days in the machine. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
100 test
Can be used on eCL8004 immunoassay machine
17
Vitamin D test
400
kiểm TRA
25-OH Vitamin D Total is an immunoassay reagent for the in vitro quantification of total 25-hydroxy Vitamin D in human serum and plasma. Results can be used to aid in the diagnosis of Vitamin D adequacy. Active ingredients: PT2 1.4% Dithiothreitol PT3 0.25M Sodium Hydroxide MB: Streptavidin-coated microparticles, 0.75 mg/mL: 0.1M PBS; 0.05% ProClin™ 300 RB: 25-OH vitamin D~ Biotin: 0.05M MES; 0.05% ProClin™ 300 RA: Anti-vitamin D ~Ru(bpy) 2+ 3: 0.05M BIS-Tris; 0.05% ProClin™ 300 Calibrator(High): Horse serum, 0.05% ProClin™ 300; lyophilized Calibrator(Low): Horse serum, 0.05% ProClin™ 300; lyophilized Control Material (High): Horse serum, 0.05% ProClin™ 300; lyophilized. Control Material (Low): Horse serum, 0.05% ProClin™ 300; lyophilized Compatible devices: Compatible devices: eCL8000, eCL8000i, eCL8000p, eCL8000x, eCL9000, eCL9000i, eCL9600, eCL9900, eCL9900i. Storage: 2 ~ 8 ℃ for 18 months, 8 weeks in the machine. Meets standards: ISO 13485:2016.
Tran Lam General Hospital, address: No. 355, Tran Lam Street, Tran Lam Ward, Hung Yen Province
100 test
Can be used on eCL8005 immunoassay machine
Approval decision information
Approval date
20/11/2025
Approval decision code
1248/QĐ-BV
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Test chemicals". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Test chemicals" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 2

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second