Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Machine Machine |
1 |
Female |
I. General Requirements - 100% new machine, manufactured in 2026 or later - Main machine origin: G20 - Meets quality standards: (ISO 13485 and CE/EU) or (ISO 13485 and FDA) or equivalent - Power supply: 220V ± 10%; 50Hz - Operating environment: Maximum temperature and humidity 40°C, 80% II. Configuration provided: - Portable main unit: 1 unit - Multi-frequency Convex transducer: 1 unit - Multi-frequency Linear transducer: 1 unit - Cardiac transducer: 1 unit - Genuine trolley: 1 unit - Specialized carrying case for ultrasound machine: 1 unit - Black and white thermal printer: 1 unit - Continuous Doppler echocardiography software - M-mode anatomy software - English and Vietnamese user manuals: 1 set - Battery life ≥ 45 minutes - Hard drive ≥ 256GB III. Technical Features and Applications: Portable ultrasound machine for vascular, abdominal, obstetric, cardiac, small organ, and gynecological examinations. 1. General Specifications - Laptop-style design, with 1 probe port on the main unit (≥ 3 probe ports with probe expansion adapter) - Display: LCD ≥ 15.6 inches, resolution: ≥ 1920 x 1080 pixels - Image depth up to ≥ 30cm (depending on probe) - Frame rate: maximum ≥ 1700 frames/second depending on probe or ≥ 2200 frames/second in 2D - Number of system processing channels: ≥ 4,700,000 channels - Dynamic range: ≥ 265 dB - Supports maximum examination frequency up to ≥ 18 MHz depending on probe - Features beam transmission and reception technology 1. Multidirectional ultrasound (complex spatial imaging) - Features noise reduction, enhanced smoothness and ultrasound image quality - Features automatic image optimization - Software used must have a perpetual license. 2. Compatible transducer types are optional, minimum: - Convex transducer - Linear transducer - Sector transducer 3. Operating modes: - B-Mode (2D) - Tissue harmony - M-Mode - Color Doppler mode - Power Doppler mode - Pulsed Doppler mode 4. Transducer - Multi-frequency Convex transducer + Applications: Abdomen, obstetrics and gynecology, urology. + Frequency range: 2.0 MHz - 5.0 MHz + Number of elements: ≥ 128 + FOV: maximum ≥ 55° - Multi-frequency Linear transducer + Applications: blood vessels, small parts, musculoskeletal system… + Frequency range: 4 MHz - 12 MHz + Number of elements: ≥ 128 - Multi-frequency Sector transducer + Applications: Heart, Blood vessels, Transcranial, Thoracic + Frequency range: 2 MHz - 4 MHz + Number of elements: ≥ 64 5. Measurement and calculation functions: minimum - Measurement/calculation in vascular applications - Measurement/calculation in obstetrics - Measurement/calculation in gynecology - Full range of basic measurements: Distance, circumference, volume, area - Automatic calculation of real-time Doppler parameters 6. B mode (2D) parameters: minimum - Complex spatial imaging up to ≥ 9 adjustable angles - Line density ≥ 5 steps or Frame rate ≥ 3 levels - Minimum gain, dynamic range, frame average, grayscale map adjustable. 7. M-mode parameters: minimum - Selectable scan rate - Adjustable gain. 8. Color Doppler parameters: minimum - Selectable frequency (with one transducer and depending on the transducer) maximum ≥ 5 steps or adaptive multi-frequency flow technology - Baseline adjustment: ≥ 10 steps - Color map, including velocity map ≥ 20 types, or ≥ 256 color boxes - Maximum pulse repetition frequency: ≥ 27 kHz - Automatic sensitivity optimization and adaptive color resolution or packet size adjustment ≤ 8 - ≥ 20. 9. Power Doppler parameters: minimum - Color map ≥ 14 types, or ≥ 256 color boxes - Maximum pulse repetition frequency ≥ 26 kHz 10. Pulsed Doppler parameters: minimum - Pulse repetition frequency: ≤ 0.3 - ≥ 27 kHz - Baseline selectable - Adjustable sampling window size: from ≤ 1.0 to ≥ 16 mm 11. Minimum post-processing modes: - Grayscale map, TGC, color map, dynamic range, baseline, scan rate, spectral inversion, noise suppression, Doppler angle, frame averaging, noise compression 12. Connectivity - Peripheral connectivity: HDMI or DisplayPort, Ethernet, USB ports - Connectivity: DICOM 3.0 |
Soc Trang General Hospital |
|||
2 |
C-Arm machine |
1 |
Female |
I. General Requirements: - Year of manufacture: 2026 or later - Equipment quality: 100% new - Main machine origin: G7 - Quality standards met: (ISO 13485 and CE/EU) or (ISO 13485 and FDA) or equivalent - Power supply: 220V ± 10%; 50Hz - Operating environment: Maximum temperature and humidity 40°C, 80% II. Configuration provided: - X-ray source and control panel: 1 set - Trolley with C-arm: 1 unit - X-ray tube: 1 unit - Beam collimator: 1 set - Contrast enhancer: 1 set - Monitoring screens: 2 units - Digital image processor: 1 unit - Auxiliary equipment + Sterilization cover: 1 set + Lead apron: 2 units + Lead neck covering for thyroid gland: 2 units - Thermal printer: 1 machine - User manual in English and Vietnamese: 1 set III. Technical Specifications: 1. C-arm trolley - Vertical movement of the C-arm: Motorized ≥ 500 mm in ≤ 60 seconds - Horizontal movement of the C-arm: Manual, ≥ 210 mm - C-arm rotation around the horizontal axis: Manual, ± ≥ 270° - C-arm rotation around the orbit: Manual, ≥ 135° - Horizontal rotation of the C-arm: Manual, ± ≥ 12.5° - C-arm opening ≥ 770 mm - C-arm depth ≥ 690 mm - Image source-to-image distance (SID) ≥ 980 mm - Distance from focal center to patient ≤ 200 mm - Minimum distance to floor ≤ 150 mm - Distance from floor to focal center ≤ 360 mm mm - Distance from floor to patient ≤ 560 mm - Distance from center of intensifier tube II to floor in oblique projection ≤ 950 mm - Width in oblique projection ≥ 1600 mm 2. X-ray source and control cabinet - Power: ≥ 5 kW - Maximum imaging voltage: ≥ 120 kV - Maximum current in imaging mode: ≥ 50 mA - mA range in imaging mode: From ≤ 0.25 to ≥ 15 mA - Maximum frame acquisition rate in pulsed imaging mode: ≥ 12 images/second - mA range in half-dose imaging mode: From ≤ 0.25 to ≥ 4 mA - mA range in Snapshot imaging mode: From ≤ 2.5 to ≥ 30 mA - mA range in strong imaging mode: From ≤ 1 up to ≥ 125 mAs - Control panel: LCD display, touch screen ≥ 5”, membrane soft keypad. - Control panel can rotate ± ≥ 60° allowing control from any direction. - Microprocessor control - Imaging techniques: + 2-point technique with kV and mAs parameter selection + APR imaging technique 3. X-ray tube - Tube type: Rotating anode, speed ≥ 3000 rpm - Focal center size: from 0.3 mm to 0.6 mm - Anode target angle: ≤ 10° - Anode heat storage: ≥ 200 kHU - Maximum anode heat dissipation: ≥ 40 kHU / minute - Tube head heat storage: ≥ 1250 kHU - Maximum continuous heat dissipation of the tube head: ≥ 60 kHU / minute 4. Beam collimator: - Type: IRIS collimator or equivalent - Scattering leakage < 1 mGy/hour 5. Intensifier - Intensifier tube + Number of fields: ≥ 3 (≥ 9” / ≥ 6” / ≥ 4”) + Output image diameter: 20 ± 0.5 mm + Useful input field size: 215 ± 5 mm / 160 ± 5 mm / 120 ± 5 mm + Center resolution ≥ 48 / ≥ 56 / ≥ 64 lp/cm + Quantum detection effect at 59.5 kV ≥ 65% - TV Camera + Resolution ≥ 1280 x 960 pixels + Pixel size ≤ 3.75 x 3.75 micron + Continuous increase reading type 6. Trolley-mounted observation screen - Number of screens Image ≥ 2 - LCD screen ≥ 19 inch - Viewing angle Horizontal ≥ 170° / Vertical ≥ 170° - Contrast ratio ≥ 2000:1 - Resolution ≥ 1280 x 1024 pixels - Pixel size ≤ 0.294 mm x 0.294 mm - Maximum brightness ≥ 330 cd/m2 - Input signals: DVI-D, Dsub (VGA) 7. Digital image processor - Image capture: ≥ 1024x1024 (≥ 12 bit) - Number of images stored on hard drive: ≥ 55,000 images - Maximum digital image capture frequency: ≥ 25 images/second - Image processing software: + Manual/automatic image adjustment + Brightness and contrast adjustment + Electronic rotation in steps ≤ 1° + Vertical and horizontal image inversion + Grayscale inversion + Filter selection: recursive filters from 1 to 16 + Smart filter with "Motion detection" function + Virtual collimator selection, electronic collimator selection (circular and rectangular) + Image edge enhancement: Smooth, normal, sharp in post-processing mode + Image zoom from 1 to 3 + Image lens selection from 1 to 3 + View multiple images: from 4 to 16 images + Character editing + Radiation dose reporting + Patient saving + Length calibration on reference object - Must have a connection port to store results on the Hospital's system. Free connection to the Hospital's management software. - The software used must have a perpetual license. |
Soc Trang General Hospital |
|||
3 |
Audiometer + Audiometry chamber |
1 |
Female |
I. General Requirements: - Year of manufacture: 2026 or later - Equipment quality: 100% new - Main machine origin: G7 or Europe - Quality standards met: (ISO 13485 and CE/EU) or (ISO 13485 and FDA) or equivalent - Power supply: 220V ± 10%; 50Hz - Operating environment: Maximum temperature and humidity 40°C, 80% II. Configuration provided: 1. Audiometer: - Main unit: 1 - Air conduction earmuffs: 1 - Connecting device for bone conduction tester: 1 - Patient feedback button: 1 - Connecting cable: 1 - Audiometry software: 1 set - Power cord: 1 - English and Vietnamese user manuals: 1 set - Accessories: + Computer: 1 set + Printer: 1 set 2. Audiometry chamber: 1. III. Technical Specifications: 1. Audiometer: - Main Features: + Display: LCD or equivalent + Number of measurement channels: 2 channels (left, right) + Minimum measurement methods: ▪ Air conduction auditory threshold audiometry ▪ Bone conduction auditory threshold audiometry ▪ Speech audiometry + Narrowband and white noise reduction features + Frequency selection feature + Hearing loss calculation feature + Stimulation type selection: Pulsed or continuous + Number of tests: ≥ 1,000 tests + Diagnostic criteria: Minimum COUNCIL, ELI, SAL, KLOCKHOFF - Standard frequency range: From ≤ 125 to ≥ 8,000 Hz - Music signal: + Frequency range: From ≤ 135 to ≥ 8,000 Hz + Intensity range: ▪ Air conduction: From ≤ 80 to ≥ 120 dB HL ▪ Bone conduction: ≤ 50 to ≥ 70 dB HL - Noise: + Narrowband noise intensity range AC: ≤ 60 to ≥ 100 dB HL + Narrowband noise intensity range BC: ≤ 50 to ≥ 70 dB HL + White noise intensity AC: ≤ 100 dB SPL + Voice noise intensity: ≤ 100 dB SPL - Standard sound intensity: ≤ 5 dB - Reference sound intensity: ≤ 1 dB - Frequency accuracy: ± ≤ 1 % - Intensity accuracy: ± ≤ 2 % dB SPL - Audiometry software: + Functions for viewing, storing, transmitting, analyzing, and presenting audiometry test results + Functions for managing data 1. Audiometer: - Includes the ability to load saved tests from the device's internal memory. - Allows for the option to perform tests with different input data. - Displays detailed information on various test types. - Allows comparison of results from multiple tests on the same patient. - Allows customization of result reports. - Allows printing of reports. - The software used must have a perpetual license. 2. Audiometer: - Meets TCVN 7878-2:2018 or equivalent standards. - Soundproof windows are made of two layers of glass, each layer ≥ 19mm thick, with a vacuum between them for high sound and heat insulation. - Inside the metering chamber, a layer of foam ≥ 30mm thick made of PE Foam or equivalent is used for sound absorption. - The floor is covered with sound-absorbing carpet, ensuring effective sound insulation. - The external power outlet connection panel is compatible with many audiometers on the market, including ≥ 6. 6.3mm jacks, ≥ 1 USB Type A jack - The connection panel inside the measuring chamber has ≥ 6 6.3mm jacks, ≥ 1 USB Type A jack - Maximum attenuation at 5kHz: ≥ 45dB - Average attenuation: ≥ 30dB 3. Computer - Intel Pentium i5 CPU or higher; RAM ≥ 4GB; SSD hard drive ≥ 256GB. - Monitor: ≥ 19 inches - Mouse and keyboard included 4. Color printer - Paper size (minimum): A4 - Color printing speed: ≥ 15 pages/minute |
Soc Trang General Hospital |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Bệnh viện đa khoa Sóc Trăng:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Bệnh viện đa khoa Sóc Trăng:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.