| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
RMU 22kV, 2-compartment type with SCADA connectivity (2 x 630A LBS circuit breakers) |
1 |
Cabinet |
Compact type, expandable on both sides, with SCADA connectivity, and 2 compartments. |
Khanh Hoa province |
IEC 62271 standard |
Delivery time: 45 days
Warranty period: 18 months
Payment terms: Within 14 days |
|
2 |
RMU 22kV, 2-compartment type, with SCADA connectivity (1 compartment for 630A LBS circuit breaker and 1 compartment for MBA surge protection device). |
1 |
Cabinet |
Compact type, expandable on both sides, with SCADA connectivity, and 2 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
3 |
RMU 22kV, 3-compartment type with SCADA connectivity (3 x 630A LBS circuit breakers). |
1 |
Cabinet |
Compact design, expandable in both directions, with SCADA connectivity, and 3 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
4 |
RMU 22kV, 3-compartment type with SCADA connectivity (2 compartments for 630A LBS circuit breakers and 1 compartment for a main breaker protection busbar) |
1 |
Cabinet |
Compact design, expandable in both directions, with SCADA connectivity, and 3 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
5 |
RMU 22kV, 3-compartment type, with SCADA connectivity (1 compartment for 630A LBS circuit breaker and 2 compartments for MBA surge arresters). |
1 |
Cabinet |
Compact design, expandable in both directions, with SCADA connectivity, and 3 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
6 |
RMU 22kV, 4-compartment type with SCADA connectivity (4 x 630A LBS circuit breakers) |
1 |
Cabinet |
Compact type, expandable in both directions, with SCADA connectivity, and 4 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
7 |
RMU 22kV, 4-compartment type with SCADA connectivity (3 compartments for 630A LBS circuit breakers and 1 compartment for a main breaker protection busbar) |
1 |
Cabinet |
Compact type, expandable in both directions, with SCADA connectivity, and 4 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
8 |
RMU 22kV, 4-compartment type with SCADA connectivity (2 compartments for 630A LBS circuit breakers and 2 compartments for MBA surge arresters). |
1 |
Cabinet |
Compact type, expandable in both directions, with SCADA connectivity, and 4 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
9 |
RMU 22kV, 4-compartment type with SCADA connectivity (2 compartments for 630A LBS circuit breakers, 1 compartment for a busbar protection device and 1 compartment for metering). |
1 |
Cabinet |
Compact type, expandable in both directions, with SCADA connectivity, and 4 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
10 |
RMU 22kV, 5-compartment type with SCADA connectivity (4 compartments for 630A LBS circuit breakers, and 1 compartment for a surge protection busbar) |
1 |
Cabinet |
Compact type, expandable in both directions, with SCADA connectivity, and 5 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
11 |
RMU 22kV, 5-compartment type with SCADA connectivity (3 compartments for 630A LBS circuit breakers, 1 compartment for MBA protection fuses, and 1 compartment for metering). |
1 |
Cabinet |
Compact type, expandable in both directions, with SCADA connectivity, and 5 compartments. |
Khanh Hoa province |
IEC 62271 standard |
||
12 |
LBS 630A Cutting Disc Guard |
1 |
Compartment |
Module type: Load shedding circuit |
Khanh Hoa province |
IEC 62271 standard |
||
13 |
MBA protection case |
1 |
Compartment |
Type of module, specifically the MBA protection module. |
Khanh Hoa province |
IEC 62271 standard |
||
14 |
Measurement and counting |
1 |
Compartment |
Module type, counting |
Khanh Hoa province |
IEC 62271 standard |
||
15 |
Low-voltage distribution panel for a 250 kVA transformer within a steel tower |
1 |
Cabinet |
Pre-fabricated, integrated within a steel column, compatible with MBA 250kVA |
Khanh Hoa province |
IEC 60947 standard |
||
16 |
Low-voltage distribution panel for a 400 kVA transformer within a steel pole |
1 |
Cabinet |
Pre-fabricated, integrated within a steel column, compatible with MBA 400kVA |
Khanh Hoa province |
IEC 60947 standard |
||
17 |
Low-voltage switchgear for a 560 kVA transformer in a steel column |
1 |
Cabinet |
Pre-fabricated, integrated within a steel column, compatible with MBA 560kVA |
Khanh Hoa province |
IEC 60947 standard |
||
18 |
Low-voltage surge arresters for a 250 kVA transformer substation |
1 |
Cabinet |
Pre-fabricated, integrated within a steel column, compatible with MBA 250kVA |
Khanh Hoa province |
IEC 60831-1/2 standards |
||
19 |
Low-voltage surge arresters for a 400 kVA transformer substation |
1 |
Cabinet |
Pre-fabricated, integrated within a steel column, compatible with MBA 400kVA |
Khanh Hoa province |
IEC 60831-1/2 standards |
||
20 |
Low-voltage surge arresters for the 560 kVA substation |
1 |
Cabinet |
Pre-fabricated, integrated within a steel column, compatible with MBA 560kVA |
Khanh Hoa province |
IEC 60831-1/2 standards |
||
21 |
MBA support structure (100-250 kVA) with an MBA enclosure. |
1 |
pillar |
Ready-made, with a protective enclosure for up to 250 kVA |
Khanh Hoa province |
IEC 60694 standard or IEC 60076 standard |
||
22 |
MBA support structure (320-400 kVA) with an MBA enclosure. |
1 |
pillar |
Ready-made, with a protective enclosure for up to 400 kVA |
Khanh Hoa province |
IEC 60694 standard or IEC 60076 standard |
||
23 |
Tru MBA 560-630 kVA with a protective enclosure |
1 |
pillar |
Pre-fabricated, with a complete MBA system up to 630 kVA |
Khanh Hoa province |
IEC 60694 standard or IEC 60076 standard |
||
24 |
MBA 100-800 kVA support structure with integrated 2-compartment RMU |
1 |
pillar |
Pre-fabricated, includes an MBA enclosure, and allows for the installation of a 2-bay RMU within the unit. |
Khanh Hoa province |
IEC 60694 standard or IEC 60076 standard |
||
25 |
MBA 100-800 kVA support structure with integrated 3-compartment RMU |
1 |
pillar |
Pre-fabricated, includes an MBA enclosure, and allows for the installation of a 3-compartment RMU within the unit. |
Khanh Hoa province |
IEC 60694 standard or IEC 60076 standard |
||
26 |
MOF 3-phase measuring set, 24kV-150(300)/5A |
1 |
Set |
150-300 Amperes |
Khanh Hoa province |
According to IEC 61869-4 |
||
27 |
MOF 3-phase measuring set, 24kV-100(200)/5A |
1 |
Set |
100-200 Amperes |
Khanh Hoa province |
According to IEC 61869-4 |
||
28 |
MOF 3-phase measuring set, 24kV-50(100)/5A |
1 |
Set |
50-100 Amperes |
Khanh Hoa province |
According to IEC 61869-4 |
||
29 |
MOF 3-phase measuring set, 24kV-30(60)/5A |
1 |
Set |
30-60 Amperes |
Khanh Hoa province |
According to IEC 61869-4 |
||
30 |
MOF 3-phase measuring set, 24kV-20(40)/5A |
1 |
Set |
20-40 Amperes |
Khanh Hoa province |
According to IEC 61869-4 |
||
31 |
35kV, 3-phase reclosing switch with all necessary accessories, conforming to regulations. |
1 |
Set |
Three-phase, 35 kV system, including accessories and a power source (MBA). |
Khanh Hoa province |
IEC 62271-111:2012 Standard |
||
32 |
35kV, 3-phase reclosing switch with all necessary accessories as per regulations (excluding power supply unit - PSU). |
1 |
Set |
Three-phase, 35 kV system, including accessories but excluding the power supply unit (PSU). |
Khanh Hoa province |
IEC 62271-111:2012 Standard |
||
33 |
22kV, 3-phase recloser with all accessories as per specifications + source transformer (MBA) |
1 |
Set |
Three-phase, 22kV system, including accessories and a power supply unit (PSU). |
Khanh Hoa province |
IEC 62271-111:2012 Standard |
||
34 |
22kV, 3-phase reclosing switch with all necessary accessories as per regulations (excluding power supply unit - PSU). |
1 |
Set |
Three-phase, 22kV system, including accessories but excluding the power supply unit (PSU). |
Khanh Hoa province |
IEC 62271-111:2012 Standard |
||
35 |
The 35kV enclosed-type, three-phase cutting circuit breaker, complete with all accessories as specified by regulations. |
1 |
Set |
Type 3-phase, 35 kV, enclosed type, including accessories and a source-side MBA (motor building assembly) |
Khanh Hoa province |
IEC 62271-103:2011 Standard |
||
36 |
The 35kV enclosed, three-phase cutting cage earthing switch complies with all regulations and includes all necessary accessories (excluding the source breaker). |
1 |
Set |
Type 3-phase, 35 kV, enclosed type, including accessories but excluding the MBA (medium-voltage breaker) |
Khanh Hoa province |
IEC 62271-103:2011 Standard |
||
37 |
The 22kV enclosed-type, three-phase cutting shears comply with all relevant regulations and come complete with all necessary accessories. |
1 |
Set |
Type 3-phase, 22kV, enclosed type, including accessories and a power supply unit (PSU). |
Khanh Hoa province |
IEC 62271-103:2011 Standard |
||
38 |
The 22kV enclosed, three-phase cutting cage is complete with all necessary accessories as per regulations (excluding the power supply unit). |
1 |
Set |
Type 3-phase, 22kV, enclosed type, including accessories but excluding the MBA (medium-voltage air circuit breaker) |
Khanh Hoa province |
IEC 62271-103:2011 Standard |
||
39 |
Step-down voltage converter (22/0.22) |
1 |
Machine |
Outdoor type, 22/0.22 kV, sold with recloser or LBS |
Khanh Hoa province |
IEC 61869-1 standard |
||
40 |
Open-type, three-phase, 35kV cutting switch with all necessary accessories for installation. |
1 |
Set |
Type 3 phase, 22 kV, open-type with accessories |
Khanh Hoa province |
IEC 62271-103:2011 Standard |
||
41 |
Open-type, three-phase 22kV cutting circuit breaker with all necessary accessories for installation. |
1 |
Set |
Type 3-phase, 35 kV, open type with accessories |
Khanh Hoa province |
IEC 62271-103:2011 Standard |
||
42 |
Open-type, three-phase 35kV isolation switch, complete with all necessary accessories for installation. |
1 |
Set |
Three-phase, 35 kV, open type |
Khanh Hoa province |
IEC 62271-102 standard |
||
43 |
Open-type, three-phase 22kV disconnect switch with all necessary accessories for vertical mounting. |
1 |
Set |
Three-phase, 22kV, open-type, vertical pole |
Khanh Hoa province |
IEC 62271-102 standard |
||
44 |
Open-type, three-phase 22kV isolating switch with all necessary accessories for installation using the "axe-through" method. |
1 |
Set |
Three-phase, 22kV, open-type, overhead pole |
Khanh Hoa province |
IEC 62271-102 standard |
||
45 |
Open-type, three-phase 22kV disconnect switch with all necessary accessories for horizontal mounting. |
1 |
Set |
Three-phase, 22kV, open-type, side-mounted |
Khanh Hoa province |
IEC 62271-102 standard |
||
46 |
22kV suspended cable support structure, single-phase, complete with all accessories. |
1 |
Set |
Type 1, 22 kV |
Khanh Hoa province |
IEC 62271-102 standard |
||
47 |
35kV suspended conductor support system, single-phase, complete with all accessories. |
1 |
Set |
Type 1, 35 kV |
Khanh Hoa province |
IEC 62271-102 standard |
||
48 |
22kV-100A self-latching polymer fuse |
1 |
Female |
polymer, 22kV, 100A |
Khanh Hoa province |
IEC 60282-2 standard |
||
49 |
22kV-200A self-falling polymer fuse |
1 |
Female |
polymer, 22kV, 200A |
Khanh Hoa province |
IEC 60282-2 standard |
||
50 |
35kV self-falling polymer connectors |
1 |
Female |
polymer, 35kV, 100A |
Khanh Hoa province |
IEC 60282-2 standard |
||
51 |
Self-latching, load-breaking bridge fuse, LBFCO-22kV (polymer) - 100A |
1 |
Female |
polymer, 22kV, 100A |
Khanh Hoa province |
IEC 60282-2 standard |
||
52 |
Self-falling, load-bearing bridge jumper cable, LBFCO-22kV (polymer) - 200A |
1 |
Female |
polymer, 22kV, 200A |
Khanh Hoa province |
IEC 60282-2 standard |
||
53 |
Self-latching, load-breaking bridge fuse, LBFCO-35kV (polymer), 100A |
1 |
Female |
polymer, 35kV, 100A |
Khanh Hoa province |
IEC 60282-2 standard |
||
54 |
18kV line surge protection device + Disconnect switch + Soft copper wire (connecting from the disconnect switch to the main grounding wire) |
1 |
Female |
polymer, 18kV, with a fault indicator connection |
Khanh Hoa province |
IEC 60099-4 standard |
||
55 |
22kV line surge arrestor + Disconnect switch + Flexible copper wire (connecting from the disconnect switch to the main grounding wire) |
1 |
Female |
polymer, 22kV, with a fault indicator connection block |
Khanh Hoa province |
IEC 60099-4 standard |
||
56 |
Jumper + Soft copper wire (connecting from the bottom of the jumper to the main ground wire) |
1 |
Female |
Accessories included: surge protection valve |
Khanh Hoa province |
TCCS 13:2021/EVN |
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor KHANH HOA POWER JOINT STOCK COMPANY:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding KHANH HOA POWER JOINT STOCK COMPANY:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.