| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Analysis: Mettler Toledo AB 204 |
1 |
Female |
Calibrated all ladder |
Medicine, cosmetic and food testing center in Son La province |
|||
2 |
Analysis: Mettler Toledo MS 204 |
1 |
Female |
Calibrated all ladder |
As above |
|||
3 |
Analysis: Mettler Toledo Me 204 |
1 |
Female |
Calibrated all ladder |
As above |
|||
4 |
Analysis of Denver TB 224 |
1 |
Female |
Calibrated all ladder |
As above |
|||
5 |
Analysis of Ohaus (EP 214) |
1 |
Female |
Calibrated all ladder |
As above |
|||
6 |
Jadever electronic engineering scales |
1 |
Female |
Calibrated all ladder |
As above |
|||
7 |
High -performance liquid chromatography HPLC Agilent 1260 |
1 |
Female |
Calibration on 1 detector:
- Flow speed accuracy
-The accuracy of the solvent mixer (03 A-B, A-C, A-D)
- The accuracy of the furnace temperature
- System repetition
- Linear volume of injection
- Linear system |
As above |
|||
8 |
Waters Alliance E 2695 |
1 |
Female |
Calibration on 1 detector:
- Flow speed accuracy
- Gradient accuracy
- The accuracy of the furnace temperature
- Repeatedly
- Linear degree |
As above |
|||
9 |
UV-VIS spectroscopy (Thermo Nicolet Evolution 300) |
1 |
Female |
Calibration: The accuracy of the wavelength. Accuracy of absorption |
As above |
|||
10 |
UV-VIS spectroscopy (Shimadzu UV 1800) |
1 |
Female |
Calibration: The accuracy of the wavelength. Accuracy of absorption |
As above |
|||
11 |
Solubility test machine 6-8 positions (PT-DT7) |
1 |
Female |
Calibration: Temperature accuracy
Stir speed accuracy
The accuracy of time counter |
As above |
|||
12 |
Electrollab EDT-08LX (Electrollab EDT-08LX) |
1 |
Female |
Calibration: Temperature accuracy
Stir speed accuracy. The accuracy of time counter |
As above |
|||
13 |
Sanaky refrigerator |
2 |
Female |
Calibration at the thermal range 2-8 degrees Celsius |
As above |
|||
14 |
Moisture (Testo 608 - H2) |
3 |
Female |
Calibration at four heat points 15, 20, 25, 30 degrees Celsius
Humidity: 40, 60, 75 % |
As above |
|||
15 |
Moisture (tanita) |
2 |
Female |
Calibration at four heat points 15, 20, 25, 30 degrees Celsius
Humidity: 40, 60, 75 % |
As above |
|||
16 |
Eyela dryer
NDO 420 |
1 |
Female |
Calibration at three heat points 70, 105, 160 degrees Celsius |
As above |
|||
17 |
MOV-212 dryer |
1 |
Female |
Calibration at three heat points 70, 105, 160 degrees Celsius |
As above |
|||
18 |
JSOF 153P dryer |
1 |
Female |
Calibration at 90 degrees heat C; 105 degrees Celsius |
As above |
|||
19 |
Hirayama steamer
HVE 50 |
2 |
Female |
Calibration at a 121 -degree heat point C |
As above |
|||
20 |
Mir 254 refrigerator |
1 |
Female |
Calibration at two heat points 25, 30 degrees Celsius |
As above |
|||
21 |
Wedco kettle |
1 |
Female |
Calibration at three heat points 30, 37, 44 degrees Celsius |
As above |
|||
22 |
JSGI warm cabinet 153 p |
1 |
Female |
Calibration at three heat points 30, 37, 44 degrees Celsius |
As above |
|||
23 |
JSGI 100P warm cabinet |
1 |
Female |
Calibration at three heat points 30, 37, 44 degrees Celsius |
As above |
|||
24 |
Sanyo-SR 13M refrigerator |
1 |
Female |
Calibration at the thermal range 2-8 degrees Celsius |
As above |
|||
25 |
Level II biological cabinet 1386 |
1 |
Female |
Calibration: the efficiency of the HEPA filter;
The speed and uniformity of the gas flow;
Light intensity and noise level;
Purple light leakage and illumination |
As above |
|||
26 |
Metrohm 827 pH |
1 |
Female |
Calibration: pH accuracy (4,7,10) |
As above |
|||
27 |
Con Ke |
1 |
Female |
Calibration: measuring range: 0-50 %Vol |
As above |
|||
28 |
Haloes caliper sterile ring meter |
1 |
Female |
Calibrated all ladder |
As above |
|||
29 |
200g standard weight |
1 |
Female |
Volume calibration calibration |
As above |
|||
30 |
Glass thermometer from 0 degrees C to 100 degrees Celsius |
1 |
Female |
Total calibration |
As above |
|||
31 |
Glass thermometer from -10 degrees C to 110 degrees Celsius |
1 |
Female |
Total calibration |
As above |
|||
32 |
Micropipet single channel strip 20 µl - 200 µl |
1 |
Female |
Calibration: at 90 µl; 100 µl |
As above |
|||
33 |
Micropipet single channel strip 20 µl - 200 µl |
1 |
Female |
Calibration: at 200 µl; 100 µl |
As above |
|||
34 |
Micropipet single channel range 1 µl - 1000 µl |
2 |
Female |
Calibration: at 100 µl; 1000 µl |
As above |
|||
35 |
Microscope 2 Glasses (Pink MC 50 Micros, Manufacturer: Micros-Austria, serial number: 2-400960) |
1 |
Female |
Calibrated all ladder |
As above |
|||
36 |
Agilent 1260 high -performance liquid chromatography |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the system "PAS" SELFTEST mode; Check the feedback of the control unit (buttons, touch, knob); The display and warning department (LCD screen, LED, Buzz ...); Check the functions of the system (pump, heating, rotary motor, lifting axis ...); Check the functions of the system (heating, probes ...); Check software activities, device warning functions.
External maintenance: Cleaning the area of equipment, equipment surface; Check the outer surface, the status of the connection port; External surface check, keyboard surface status, display screen, computer system and warning sensor system; Check the outer surface and clean the solvent filter (ultrasound with water solvent> isopropyl> water) minimize 5 minutes for each stage.
Inner maintenance: Examining the exterior of the capillary wire system (capillary wiring system, no connector without the phenomenon of breaking, broken and leaked solvent); Check the exterior and clean the heat load system of the modules; External surface testing and circuit board hygiene; Inspect and maintain the system movement system; Check out and clean the probe system; Run wash the whole system with water solvents> isopropyl> Water) Single channel minimum 10 minutes for each stage, according to the program: column: capillary, current rate [1 ÷ 2] ml/minute
Hygiene, maintenance of Pump systems (including pump system, mixer, conductor, bottle bottle ...), detector, - Check the stability of the device.
Review linear, repeat
After sanitation, maintenance, conduct the operation of the device: |
As above |
|||
37 |
Waters Alliance E 2695 |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the system "PAS" SELFTEST mode; Check the feedback of the control unit (buttons, touch, knob); The display and warning department (LCD screen, LED, Buzz ...); Check the functions of the system (pump, heating, rotary motor, lifting axis ...); Check the functions of the system (heating, probes ...); Check software activities, device warning functions.
External maintenance: Cleaning the area of equipment, equipment surface; Check the outer surface, the status of the connection port; External surface check, keyboard surface status, display screen, computer system and warning sensor system; Check the outer surface and clean the solvent filter (ultrasound with water solvent> isopropyl> water) minimize 5 minutes for each stage.
Inner maintenance: Examining the exterior of the capillary wire system (capillary wiring system, no connector without the phenomenon of breaking, broken and leaked solvent); Check the exterior and clean the heat load system of the modules; External surface testing and circuit board hygiene; Inspect and maintain the system movement system; Check out and clean the probe system; Run wash the whole system with water solvents> isopropyl> Water) Single channel minimum 10 minutes for each stage, according to the program: column: capillary, current rate [1 ÷ 2] ml/minute
Hygiene, maintenance of Pump systems (including pump system, mixer, conductor, bottle bottle ...), detector, - Check the stability of the device.
Review linear, repeat
After sanitation, maintenance, conduct the operation of the device: |
As above |
|||
38 |
UV-VIS spectroscopy (Thermo Nicolet Evolution 300) |
1 |
Female |
Maintenance and maintenance: Pre -maintenance inspection: Checking the structure of farming sources, connecting equipment to appropriate farming sources; Check the operation structure of the device, key, and connect ports.
- External inspection: hygiene around the device; check and clean the connection ports; Clean the keyboard, the display screen and the sample optical lid.
- Maintenance of sample measuring compartment: Cleaning cuvert surface racks; Cleaning the measuring compartment, cleaning the transmission door; Clean the sample tray.
- Maintenance of light cavity: Cleaning the compartment; Cleaning the transmission door, checking and cleaning light source lights; Check, hygiene parallel to heat, unanimous fans.
- Maintenance of optical cavity: Hygiene of compartments, hygiene and hygiene, reflected mirrors. |
As above |
|||
39 |
UV-VIS spectroscopy (Shimadzu UV 1800) |
1 |
Female |
Maintenance and maintenance: Pre -maintenance inspection: Checking the structure of farming sources, connecting equipment to appropriate farming sources; Check the operation structure of the device, key, and connect ports.
- External inspection: hygiene around the device; check and clean the connection ports; Clean the keyboard, the display screen and the sample optical lid.
- Maintenance of sample measuring compartment: Cleaning cuvert surface racks; Cleaning the measuring compartment, cleaning the transmission door; Clean the sample tray.
- Maintenance of light cavity: Cleaning the compartment; Cleaning the transmission door, checking and cleaning light source lights; Check, hygiene parallel to heat, unanimous fans.
- Maintenance of optical cavity: Hygiene of compartments, hygiene and hygiene, reflected mirrors. |
As above |
|||
40 |
Solubility test machine (PT-DT7) |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the response of the keys; Check the functions of the system (pump, heating, rotary motor, lifting axis ..); Check software activities, device warning functions.
- External maintenance and hygiene of circuit boards: San surface hygiene around the device (above, below, side and back of the device), equipment area; check the appearance, status and hygiene reinforcing connectors; Check the outer surface, status and keyboard hygiene, display screen.
- Maintenance of heating unit: Examination of external surface, hygiene of heat circulation system, check the status of valve locks, circulation pipes.
- Maintenance of motor system: Examination check, motor system, transmission axis; Maintenance of motor systems, lifting shafts, transmission systems.
- Check the accuracy and frequency of fluctuations |
As above |
|||
41 |
Electrollab EDT-08LX) |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the response of the keys; Check the functions of the system (pump, heating, rotary motor, lifting axis ..); Check software activities, device warning functions.
- External maintenance and hygiene of circuit boards: San surface hygiene around the device (above, below, side and back of the device), equipment area; check the appearance, status and hygiene reinforcing connectors; Check the outer surface, status and keyboard hygiene, display screen.
- Maintenance of heating unit: Examination of external surface, hygiene of heat circulation system, check the status of valve locks, circulation pipes.
- Maintenance of motor system: Examination check, motor system, transmission axis; Maintenance of motor systems, lifting shafts, transmission systems.
- Check the accuracy and frequency of fluctuations |
As above |
|||
42 |
Sanaky refrigerator |
2 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
Maintenance: Technical inspection of heat system: Settings system display operating; The heating system is active.
Maintenance above the device: cleaning on the roof or lid above the device.
Maintenance inside the working compartment: Checking and hygiene for convections naturally; Check the sanitation of frames, drawers, and heat blowing compartments; Checking the anticoagulant system, anti -freezing; Sensor hygiene inspection; test heating system; Hygiene and hygiene of heating system; cleaning the working compartment and wheels, brackets ...; Hygiene of heat -conducting compartments, cooling fans, heat dispersion fans; checking the lighting system; Check the sanitation of the device's installation system.
Maintenance behind the device: cleaning the surface of the device; Cleaning the cooling system of the device; Clean the wastewater discharge system.
Maintenance outside the device: Cleaning around the device
Temperature accuracy
Operating characteristics |
As above |
|||
43 |
Eyela dryer
NDO 420 |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the conformity with technical requirements of parts, shapes, models ...; check equipment information, instructions for thick and clear use; Checking the structure of farming sources, connecting equipment to appropriate farming sources, turning on the source, checking the operating structure of the display, the key, the connection ports; Check the operating status of the sensor motor; Assessment of equipment status.
- External maintenance: Cleaning the surface around the device (above, below, on the side and behind the device), the area where the device is placed in the external surface test, the condition and hygiene, reinforcing the connection ports.
- Maintenance of the area above the cabinet: Checking, hygiene and protection, door adjustment doors (input); Checking and reinforcing the power source connection to motor, motor movement, motor regulating system; check and clean the rough filter, added an appendage; Check, sanit Sensor wind speed.
- Internal maintenance: Checking and cleaning the wind cavity; check and clean motor, rotor, suction cage; check and clean the surface of HEPA filters; Cable check, Motor hygiene.
- Maintenance of working areas: Checking and cleaning the protective mesh and the surface of HEPA filters; Checking for lighting systems, UV (light bulbs, tanfo, electrical connections, switches ..); Check, hygiene around the working compartment and door frame, safe sensor, switch sensor.
- Maintenance of the area below: Check and hygiene of rough filter surface; Check and clean power connections to motor, motor starting parts, wind sensor, speed ...
- Maintenance of the rear area: Checking, hygiene of cable connection, opposite motor hygiene, counterweight plate; Hygiene test behind the back of the device has a poly.
- Maintenance of the control system: Checking and cleaning the keyboard, the connections.
- Post -maintenance test: noise test; Check the wind speed through the door; check the wind speed down the working compartment surface; light illuminance down to the working surface (background light) (Lux); testing the visible lighting at the working surface; Filter efficiency testing; Test purple light intensity. |
As above |
|||
44 |
MOV-212 dryer |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the conformity with technical requirements of parts, shapes, models ...; check equipment information, instructions for thick and clear use; Checking the structure of farming sources, connecting equipment to appropriate farming sources, turning on the source, checking the operating structure of the display, the key, the connection ports; Check the operating status of the sensor motor; Assessment of equipment status.
- External maintenance: Cleaning the surface around the device (above, below, on the side and behind the device), the area where the device is placed in the external surface test, the condition and hygiene, reinforcing the connection ports.
- Maintenance of the area above the cabinet: Checking, hygiene and protection, door adjustment doors (input); Checking and reinforcing the power source connection to motor, motor movement, motor regulating system; check and clean the rough filter, added an appendage; Check, sanit Sensor wind speed.
- Internal maintenance: Checking and cleaning the wind cavity; check and clean motor, rotor, suction cage; check and clean the surface of HEPA filters; Cable check, Motor hygiene.
- Maintenance of working areas: Checking and cleaning the protective mesh and the surface of HEPA filters; Checking for lighting systems, UV (light bulbs, tanfo, electrical connections, switches ..); Check, hygiene around the working compartment and door frame, safe sensor, switch sensor.
- Maintenance of the area below: Check and hygiene of rough filter surface; Check and clean power connections to motor, motor starting parts, wind sensor, speed ...
- Maintenance of the rear area: Checking, hygiene of cable connection, opposite motor hygiene, counterweight plate; Hygiene test behind the back of the device has a poly.
- Maintenance of the control system: Checking and cleaning the keyboard, the connections.
- Post -maintenance test: noise test; Check the wind speed through the door; check the wind speed down the working compartment surface; light illuminance down to the working surface (background light) (Lux); testing the visible lighting at the working surface; Filter efficiency testing; Test purple light intensity. |
As above |
|||
45 |
JSOF 153P dryer |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the conformity with technical requirements of parts, shapes, models ...; check equipment information, instructions for thick and clear use; Checking the structure of farming sources, connecting equipment to appropriate farming sources, turning on the source, checking the operating structure of the display, the key, the connection ports; Check the operating status of the sensor motor; Assessment of equipment status.
- External maintenance: Cleaning the surface around the device (above, below, on the side and behind the device), the area where the device is placed in the external surface test, the condition and hygiene, reinforcing the connection ports.
- Maintenance of the area above the cabinet: Checking, hygiene and protection, door adjustment doors (input); Checking and reinforcing the power source connection to motor, motor movement, motor regulating system; check and clean the rough filter, added an appendage; Check, sanit Sensor wind speed.
- Internal maintenance: Checking and cleaning the wind cavity; check and clean motor, rotor, suction cage; check and clean the surface of HEPA filters; Cable check, Motor hygiene.
- Maintenance of working areas: Checking and cleaning the protective mesh and the surface of HEPA filters; Checking for lighting systems, UV (light bulbs, tanfo, electrical connections, switches ..); Check, hygiene around the working compartment and door frame, safe sensor, switch sensor.
- Maintenance of the area below: Check and hygiene of rough filter surface; Check and clean power connections to motor, motor starting parts, wind sensor, speed ...
- Maintenance of the rear area: Checking, hygiene of cable connection, opposite motor hygiene, counterweight plate; Hygiene test behind the back of the device has a poly.
- Maintenance of the control system: Checking and cleaning the keyboard, the connections.
- Post -maintenance test: noise test; Check the wind speed through the door; check the wind speed down the working compartment surface; light illuminance down to the working surface (background light) (Lux); testing the visible lighting at the working surface; Filter efficiency testing; Test purple light intensity. |
As above |
|||
46 |
2 times distilled water machine |
2 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the response of the keys; check the functions of the system (system, pump system ..); Check software operations of device warning functions.
- Perform maintenance: Cleaning, cleaning the working area and around the equipment surface; Clean the water valve, pipe, input water filter; Clean the connection valve; check the status and hygiene of burning rods; check the status and hygiene of glass; check the status of the probe; Check water float hygiene |
As above |
|||
47 |
Hirayama HVE 50 (50 liters) |
2 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection: Settings system displaying operations; The heating system is active.
- Hygiene outside the device: close hygiene; Safety valve and sensor examination; Check the display screen hygiene, Settings key system.
- Cleaning the working compartment: Cleaning in the heart of the device; Hygiene of thermal probes, pressure gauges; hygiene of heat resistance, resistance protection lid; Check cleaning ron, lid; Check the hygiene of valves, lock lids ...
- Hygiene inside the device: checking the motherboard hygiene, hourly clock, protective clock, Role ...; Examining hygiene of overheating system; hygiene of exhaust pipes, wastewater tanks; check and hygiene of water cooling system; check water float hygiene; check steam and pressure pipelines; Water supply valve hygiene; Clean the pressure pipe pressure, magnetic valves; Check pressure gauges, safety valves. |
As above |
|||
48 |
Mir 254 refrigerator |
1 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Maintenance above the device: cleaning on the lid or lid above the device; Check, clean the key system, install the device; check and clean the donation system of the device; control and hygiene of control boad; Check the source system hygiene.
- Maintenance inside the working compartment: Checking and cleaning the convection tubes naturally; Checking and cleaning frames, drawers, and heating compartments; check and clean the aluminum radiator; test heating system; check the heating system; Cleaning the working compartment and wheels, brackets ...
- Maintenance behind the device: cleaning the surface of the device's back
- Maintenance outside the device: Cleaning around the device.
- Check the temperature after maintenance
- Temperature accuracy |
As above |
|||
49 |
Wedco kettle |
1 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Maintenance above the device: cleaning on the lid or lid above the device;
- Maintenance inside the working compartment: Checking and sanitation maintenance inside the working compartment: Checking and cleaning the convection tube naturally; Checking and cleaning frames, drawers, and heating compartments; check and clean the aluminum radiator; check the heating system; cleaning the working compartment and wheels, brackets ...; Hygiene of thermal cavity, dispersed fan.
- Maintenance behind the device: cleaning the surface of the device's back
- Maintenance outside the device: Cleaning around the device, cleaning the display screen; Clean the device's installation system.
- Check the temperature after maintenance
- Temperature accuracy |
As above |
|||
50 |
JSGI warm cabinet 153 p |
1 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Maintenance above the device: cleaning on the lid or lid above the device;
- Maintenance inside the working compartment: Checking and sanitation maintenance inside the working compartment: Checking and cleaning the convection tube naturally; Checking and cleaning frames, drawers, and heating compartments; check and clean the aluminum radiator; check the heating system; cleaning the working compartment and wheels, brackets ...; Hygiene of thermal cavity, dispersed fan.
- Maintenance behind the device: cleaning the surface of the device's back
- Maintenance outside the device: Cleaning around the device, cleaning the display screen; Clean the device's installation system.
- Check the temperature after maintenance
- Temperature accuracy |
As above |
|||
51 |
JSGI 100P warm cabinet |
1 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Maintenance above the device: cleaning on the lid or lid above the device;
- Maintenance inside the working compartment: Checking and sanitation maintenance inside the working compartment: Checking and cleaning the convection tube naturally; Checking and cleaning frames, drawers, and heating compartments; check and clean the aluminum radiator; check the heating system; cleaning the working compartment and wheels, brackets ...; Hygiene of thermal cavity, dispersed fan.
- Maintenance behind the device: cleaning the surface of the device's back
- Maintenance outside the device: Cleaning around the device, cleaning the display screen; Clean the device's installation system.
- Check the temperature after maintenance
- Temperature accuracy |
As above |
|||
52 |
Refrigerator 130 liters |
1 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Maintenance above the device: cleaning on the lid or lid above the device;
Maintenance inside the working compartment: Checking and cleaning the natural convection tube; Checking and cleaning frames, drawers, and heating compartments; checking anticoagulant and anti -freezing systems; Check and clean the protective sensor; test heating system; check and clean the heating system; Cleaning the working compartment and wheels, racks ...; check and clean the lighting system; Check the equipment installation system.
- Maintenance behind the device: cleaning the surface of the device; Cleaning the device cooling system (fan, heat sink ...); Clean the wastewater discharge system.
- Maintenance outside the device: Cleaning around the device,
- Check the temperature after maintenance
- Temperature accuracy |
As above |
|||
53 |
314 liters |
1 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Maintenance above the device: cleaning on the lid or lid above the device;
Maintenance inside the working compartment: Checking and cleaning the natural convection tube; Checking and cleaning frames, drawers, and heating compartments; checking anticoagulant and anti -freezing systems; Check and clean the protective sensor; test heating system; check and clean the heating system; Cleaning the working compartment and wheels, racks ...; check and clean the lighting system; Check the equipment installation system.
- Maintenance behind the device: cleaning the surface of the device; Cleaning the device cooling system (fan, heat sink ...); Clean the wastewater discharge system.
- Maintenance outside the device: Cleaning around the device,
- Check the temperature after maintenance
- Temperature accuracy |
As above |
|||
54 |
Level II biosafety cabinets |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the conformity with technical requirements of parts, shapes, models ...; check equipment information, instructions for full and clear use; Checking the source structure to connect equipment to the appropriate source, turning on the power, checking the operation structure of the device, the key, the connection ports; Check the operating status of motor, sensors; Assessment of equipment status.
- External maintenance: Cleaning the surface around the device (above, below, on the side and behind the device), the equipment area; Examining exterior, condition and hygiene, the price has connected ports; Check out the appearance, status and clean the keyboard, display screen
- Maintenance of the area above the cabinet: Checking, hygiene and protection, door adjustment door and output; Check the hygiene to reinforce power ports connecting the power to the motor, the motorbike booting, the motor regulating system; check and clean the filter plate, extra appendage; Check, sanit Sensor wind speed.
- Inner maintenance: Checking and hygiene of wind circulation; check and clean the surface of HEPA filters; Cable check, Motor hygiene.
- Maintenance of working area: Checking, cleaning the protection mesh and the surface of HEPA filters; check and clean the lighting system, UV (light bulbs, tanfo, electrical connections, switches ...); Check, hygiene around the working compartment and door frame, safety, switch sensor.
- Maintenance of the area below: Check and clean the rough filter; Check and clean power source connections to motor, motor starting parts, wind sensor, speed ...; check and clean the safety parts (shields, mesh); Checking, cleaning the wind cavity, exhaust blades ...
- Maintenance of the rear area: Checking, hygiene of connections, counterpart motor hygiene, counterweight panels; Check and clean the sheet behind the device, the poly.
- Maintenance of control systems: Checking, hygiene of source, control of connections; check, clean the controller, wind speed; Check, give birth to the keyboard, the connection. |
As above |
|||
55 |
HB Incourse Cabinet |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Check the conformity with technical requirements of parts, shapes, models ...; check equipment information, instructions for full and clear use; Checking the source structure to connect equipment to the appropriate source, turning on the power, checking the operation structure of the device, the key, the connection ports; Check the operating status of motor, sensors; Assessment of equipment status.
- External maintenance: Cleaning the surface around the device (above, below, on the side and behind the device), the equipment area; Examining exterior, condition and hygiene, the price has connected ports;
- Maintenance of the area above the cabinet: Checking, hygiene and protection, door adjustment door and output; Check the hygiene to reinforce power ports connecting the power to the motor, the motorbike booting, the motor regulating system; check and clean the filter plate, extra appendage; Check, sanit Sensor wind speed.
- Inner maintenance: Checking and hygiene of wind circulation; check and clean the surface of HEPA filters; Check cleaning motor, rotor, suction cage; Cable check, Motor hygiene.
- Maintenance of working area: Checking, cleaning the protection mesh and the surface of HEPA filters; check and clean the lighting system, UV (light bulbs, tanfo, electrical connections, switches ...); Check, hygiene around the working compartment and door frame, safety, switch sensor.
- Maintenance of the area below: Check and clean the rough filter; Check and clean power source connections to motor, motor starting parts, wind sensor, speed ....
- Maintenance of the rear area: Checking, hygiene of connections, counterpart motor hygiene, counterweight panels; Check and clean the sheet behind the device, the poly.
- Maintenance of the control system: Checking and cleaning the keyboard, the connections.
Check after maintenance: Check noise; check the wind speed through the door; check the wind speed down the working compartment surface; light illuminance down to the working surface (background light) (Lux); testing anti -anti -anti -anti -antibodies at the working surface, LUX; testing of filters, %; Test purple light intensity. |
As above |
|||
56 |
Metrohm 827 pH |
1 |
Female |
Maintenance, maintenance: Pre -maintenance test: Equipment information
- Inner and external maintenance: hygiene around the device; check and clean the connection ports; Clean the keyboard, exam screen, battery sliding tray; Checking connection wire hygiene; Check, clean the main motherboard and control bo.
- Sensor maintenance: Examination and hygiene of electrode; Add electrolytic solution; Check and clean the temperature probe.
- Check accuracy
- Check electrode performance |
As above |
|||
57 |
IR turbine meter 1000 |
1 |
Female |
Maintenance, maintenance: Pre -maintenance test: Equipment information
- Inner and external maintenance: hygiene around the device; check and clean the connection ports; Clean the keyboard, exam screen, battery sliding tray; Checking connection wire hygiene; Check, clean the main motherboard and control bo. |
As above |
|||
58 |
UDK 132 and DK6 semi -automatic protein machine |
1 |
Female |
Maintenance and maintenance: Pre -maintenance test: Selftest mode "pass" system; Check the feedback of the control set (buttons, touch, knob); Warning display (LCD screen, LED light, Buzz ...); check the functions of the system (pump, heating, rotary motor, lifting axis ...); check the functions of the system (heating, probes ...); Check software activities, device warning functions.
- Maintenance of working areas: Checking and hygiene around the device; checking hygiene of source ports, external auxiliary equipment; Check the key to the key, the display screen; Clean the display area; Cleaning racks, inspiration trays; Check and clean the steam and pipes of the sample; Check and hygiene Roang high steam tube.
- Maintenance inside the device: Checking and sanitizing cooling water pipes, input water, water supply to the tank, shot pipes, titration chemicals; Check the skin of the source switch; check and clean the keyboard board and display screen; Hygiene of vapors.
- Check post -cell postparts |
As above |
|||
59 |
Polarized (0-100%) |
1 |
Female |
Maintenance, maintenance: External inspection: Equipment information, fully instructed
- Technical test: installation system, display normal operation
- Perform maintenance: hygiene outside the device, sanitizing the measuring compartment; Hygiene of light sources, cleaning the viewfinder; Tell the point not equal to the adjustment screw.
- Measurement test: repeat level |
As above |
|||
60 |
Germany Nabbertherm furnace |
1 |
Female |
Maintenance and nursing: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Cleaning outside the device: cleaning the protective plate, the upper heat holder; Check the roof cleaning or lid above the device; Check the display screen hygiene, Settings system; Clean the back of the device.
- Hygiene of working compartments: hygiene of heating system; Cleaning the temperature probe; Clean the compartment
- Check the temperature after maintenance: temperature accuracy; Operating characteristics. |
As above |
|||
61 |
Sample stirrer T 180D |
1 |
Female |
Maintenance and maintenance: Power inspection: Using the power meter to check the power plug source, checking the grounding
- Check and clean the entire body and shell: Use a clean towel and alcohol to clean the outer shell of the device, the power cord.
- Check the sensitivity of the function keys.
- Check the board of the machine, check the sample stirring speed. |
As above |
|||
62 |
GFL1002-1013 thermal cashew tank |
1 |
Female |
Maintenance and maintenance: External inspection: Equipment information.
- Technical inspection of heat system: Settings display system; The heating system is active.
- Maintenance of heat compartments: Cleaning the working compartment; check the hygiene of thermal probes; Check hygiene of heating system.
- Maintenance inside the device: Cleaning the inner compartment of the device.
- Maintenance around the device: Cleaning, cleaning working surfaces and around the equipment surface; hygiene of drainage system; Screen hygiene and control system.
- Check the temperature after maintenance: temperature accuracy; Operating characteristics. |
As above |
|||
63 |
Electronic technical scales 2 numbers Sky 600t |
1 |
Female |
Maintenance, maintenance: Checking and cleaning the whole body, shell
- Check the accuracy of the weight weight
- Check the stability of the device |
As above |
|||
64 |
Microscope 2 vision Pink MC 50 micros |
1 |
Female |
Maintenance, maintenance: Checking and cleaning the whole body, shell
- Check the accuracy of the weight weight
- Check the stability of the device
- External inspection: Equipment information
- Clean the entire surface of the glass, glass, glass objects with solutions and dedicated towels.
- Check and clean the lighting system (lights, reflected mirrors). |
As above |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Trung tâm Kiểm nghiệm thuốc, mỹ phẩm, thực phẩm tỉnh Sơn La:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Trung tâm Kiểm nghiệm thuốc, mỹ phẩm, thực phẩm tỉnh Sơn La:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.