| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Endoscopic surgery kit to hold the uterus |
1 |
Set |
General requirements:
- Equipment status: 100% new
- Quality standard: ISO 13485: 2016 is equivalent
- Origin: belonging to European countries, G7
Specifications:
- Need to lift uterus in the endoscopy of the uterus.
- Fix tightly into the cervix thanks to the special spiral barrel that helps to create the tension of the uterus and keep a safe distance from the bladder to avoid vaginal gas leakage during the endoscopy of the uterus.
- The cover of ceramics is about 40 mm, 35 mm, 32 mm or equivalent to suit the size of the vaginal arch. The working barrel works with a diameter of about 6 mm, with a length of about 60 mm, 80 mm, 100 mm
- There is a covered lid that helps easily observe the vaginal arch and plays a few tricks as the guide when removing the uterus is cut through the vagina. |
Nam Dinh Obstetrics and Gynecology Hospital |
|||
2 |
The uterus kit diagnosed and intervened |
1 |
Set |
General requirements:
- Status: 100% new
- Quality standard: ISO 13485: 2016 is equivalent
- Origin: belonging to European countries, G7
Specifications:
- The lens has a view of about 30 degrees, a diameter of about 4mm, a length of 30 cm, which can be sterilized. In the heart, there is a glass -shaped lens that helps to increase the field, the tip of the tube has scratch -resistant sapphire or equivalent.
- Endoscopic cutting hand: The endoscopic hand cutting of the bipolar cavity, cut with the thumb.
- The shell places the scope includes: the outer shell and the inner shell.
+ The shell places the cutting tube, the rotating type, about 26 Fring, there are 2 input and output lines for continuous or equivalent watering. Working length is about 185mm. The inner shell can revolve around the outer shell, the tip of the insulated shell made of ceramic material or equivalent.
- Barreling barrel: The barrel set the standard or equivalent.
- Round -shaped electrode is about 26 Fr.
-The hemostasis is about 26 Fr.
-The pointed polarization is about 26 Fr.
- Electrode protection tube: The tube has the effect of protecting electrode
- Sterilization box and preserve the scope, used for a working tube with a working length ≥ 34 cm, with silicone support cushions or equivalent, with lids. External size: about 430 x 65 x 52 mm
- Sterile and preserving tools, plastic or equivalent, perforated, transparent lid, silicone carpet or equivalent. External size: about 515 x 237 x 65 mm
- Disinfection box, about 740 x 220 x 132mm, including 3 parts: box, perforated tray, lid. |
Nam Dinh Obstetrics and Gynecology Hospital |
|||
3 |
Endoscopic stitching tools |
1 |
Set |
General requirements:
- Status: 100% new
- Quality standard: ISO 13485: 2016 is equivalent
- Origin: belonging to European countries, G7
Specifications:
- Kim clamp, straight jaw: needle clamp, straight jaw, straight handles with finger piercing holes and brake locks or equivalent. About 5 mm in diameter, about 32 cm long
- Kim clamps, left curved jaws: needle clamps, left curved jaws, piece, straight handles with fingers and brakes or equivalent. About 5 mm in diameter, about 32 cm long
- The blade is hooked, the function is about 10 mm long, single operation. About 5 mm, about 36 cm in length
- The outer shell, metal or equivalent, with an insulation, with a Luer lock connector for watering. About 5 mm, about 36 cm long
- Endoscopic surgery, plastic or equivalent, unlocked. |
Nam Dinh Obstetrics and Gynecology Hospital |
|||
4 |
Babies hearing screening machine |
1 |
Female |
General requirements: - Main machine manufacturing year: 2024 or later - Equipment status: 100% new - Quality standards: ISO 13485: 2016 equivalent - Origin: European countries, G7 - Operating environment: + Operating temperature: 10ºC ~ 30ºC + Operating humidity: 30% ~ 75% - Power source: 220V, 50-60 Hz Minimum configuration includes: - Main machine: 01 unit - Probe with cable clip: 01 set - Electrode cable: 01 unit - Electrode patch: 01 bag - Skin gel: 01 bottle - Cotton: 01 bag - Probe testing compartment: 01 unit - Earbud connector: 05 units - Earbud set: 01 set - Battery charger: 01 set - User manual: 01 set Technical parameters: - Switchable between clinical analysis and screening modes - ≥ 3 built-in measurements on the machine: DPOAE, TEOAE, ABR - Storage on the main machine: ≥ 1000 tests or ≥ 1Gb - Ability to print wirelessly to a mini printer or equivalent. - DPOAE mode: measuring distorted product OAEs + Test configuration: ≥ 6 protocols, ≥ 8 parameters + Frequency range: 1 to ≤ 8 kHz, ≥ 12 frequencies + Frequency resolution: ≥ 4 points/octave + Stimulation level: ≥ 60/50 to ≤ 70/70 (dBSPL) + Passing criteria: ≥ 3 parameters + Signal to noise ratio: 1 to ≤ 10 dB per frequency band (∆1dB) + Frequency ratio F2 = 1.22 F1 - TEOAE mode: measuring transient Evoked OAEs + Test configuration: ≥ 2 protocols, ≥ 8 parameters + Frequency range: ≥ 1 to ≤ 4 kHz + Frequency resolution: approximately 1/2 octave + Stimulus level: 60 to ≤ 84 (∆1dB) (dBSPLpe) + Minimum pass criteria: 2, 3 or 4 1/2 octaves, wide or narrow band to pass + Signal to sound ratio: 6 dB ± 2 dB - ABR mode: ABR auditory brainstem response measurement + Stimulus level: can be set from ≥ 5 to ≤ 60 dBHL + Stimulus repetition rate: ≥ 50 to ≤ 93 Hz + Stimulus type: Click or Chirp. + CMRR amplifier: > 60 dB at 100 Hz - Multiple user logins can be created simultaneously with password protection with administrator control - Full patient data can be entered when needed - Data display: + Resolution: QVGA or better (≥ 320 x 240 pixels), ≥ 166 dpi + Technology: Color LCD, 16 bit (displaying 65K colors) or better - Power: rechargeable battery ≥ 1000 mAh lithium polymer or equivalent. - Charging time: When charging ≤ 3 hours to 90% battery When charging ≤ 4 hours to 100% battery |
Nam Dinh Obstetrics and Gynecology Hospital |
|||
5 |
Body mass index meter |
1 |
Machine |
General requirements:
- Year of producing the main machine: in 2024 onwards
- Equipment status: 100% new
- Quality standard: ISO 13485: 2016 is equivalent
- Operating environment:
+ Operating temperature: 10ºC ~ 30ºC
+ Activity moisture: 30% ~ 75%
- Power source used: 220V, 50-60 Hz
Specifications
Beer frequency: Minimum with frequencies 5, 50, 250kHz
The age of users can install: from 6 to 99 years old or better
Maximum load: ≥ 270kg; Division: ≤ 0.1kg
The minimum connection interface has: RS232, USB, SD
Overall analysis of body components:
At least there are indicators:
- Weight
-BMI block index
- % body fat
-Organ fat level
-Grease volume
-Fatty mass
-Mechanical mass
-Close physique
-Total body water
- % of body water
-ECW extracellular water
-ICW intracellular water
-ECW/TBW ratio
-Phase angle
-Basic BMR metabolism speed
-Biological age
-Directive of mineral bone volume
Analyze each part of the body component:
At least there are indicators:
- % of the body fat
-Assess the amount of body fat parts
-The amount of body partial body
-Evaluation of partial body muscles
-Balancing the amount of body partial body
-Electrical resistance each part of the body
-Foot muscle score
-The angle of each part of the body |
Nam Dinh Obstetrics and Gynecology Hospital |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Bệnh viện Phụ sản Nam Định:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Bệnh viện Phụ sản Nam Định:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.