Invite to quote equipment and subclinical machines

Find: 15:21 03/09/2025

Bid info

Project name/purchase estimate
Shopping for equipment and subclinical machines
Bid name
Shopping for equipment and subclinical machines

Basic information of the request for quotation

Request for quotation code
RQ2500011020-00
Status
Posted
Name of request for quotation
Invite to quote equipment and subclinical machines
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
168 Tran Dang Ninh, Phường Nam Định, Province Ninh Bình
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Trần Đình Duẫn
Position
Deputy Head of Department - Division of VT -TBYT
Phone number
Address
No. 168 Tran Dang Ninh, Nam Dinh Ward, Ninh Binh Province

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 03/09/2025 15:20 To date 13/09/2025 17:00
Validity period of quotation
90 Day kể từ ngày 13/09/2025 17:00
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
Endoscopic surgery kit to hold the uterus
1
Set
General requirements: - Equipment status: 100% new - Quality standard: ISO 13485: 2016 is equivalent - Origin: belonging to European countries, G7 Specifications: - Need to lift uterus in the endoscopy of the uterus. - Fix tightly into the cervix thanks to the special spiral barrel that helps to create the tension of the uterus and keep a safe distance from the bladder to avoid vaginal gas leakage during the endoscopy of the uterus. - The cover of ceramics is about 40 mm, 35 mm, 32 mm or equivalent to suit the size of the vaginal arch. The working barrel works with a diameter of about 6 mm, with a length of about 60 mm, 80 mm, 100 mm - There is a covered lid that helps easily observe the vaginal arch and plays a few tricks as the guide when removing the uterus is cut through the vagina.
Nam Dinh Obstetrics and Gynecology Hospital
2
The uterus kit diagnosed and intervened
1
Set
General requirements: - Status: 100% new - Quality standard: ISO 13485: 2016 is equivalent - Origin: belonging to European countries, G7 Specifications: - The lens has a view of about 30 degrees, a diameter of about 4mm, a length of 30 cm, which can be sterilized. In the heart, there is a glass -shaped lens that helps to increase the field, the tip of the tube has scratch -resistant sapphire or equivalent. - Endoscopic cutting hand: The endoscopic hand cutting of the bipolar cavity, cut with the thumb. - The shell places the scope includes: the outer shell and the inner shell. + The shell places the cutting tube, the rotating type, about 26 Fring, there are 2 input and output lines for continuous or equivalent watering. Working length is about 185mm. The inner shell can revolve around the outer shell, the tip of the insulated shell made of ceramic material or equivalent. - Barreling barrel: The barrel set the standard or equivalent. - Round -shaped electrode is about 26 Fr. -The hemostasis is about 26 Fr. -The pointed polarization is about 26 Fr. - Electrode protection tube: The tube has the effect of protecting electrode - Sterilization box and preserve the scope, used for a working tube with a working length ≥ 34 cm, with silicone support cushions or equivalent, with lids. External size: about 430 x 65 x 52 mm - Sterile and preserving tools, plastic or equivalent, perforated, transparent lid, silicone carpet or equivalent. External size: about 515 x 237 x 65 mm - Disinfection box, about 740 x 220 x 132mm, including 3 parts: box, perforated tray, lid.
Nam Dinh Obstetrics and Gynecology Hospital
3
Endoscopic stitching tools
1
Set
General requirements: - Status: 100% new - Quality standard: ISO 13485: 2016 is equivalent - Origin: belonging to European countries, G7 Specifications: - Kim clamp, straight jaw: needle clamp, straight jaw, straight handles with finger piercing holes and brake locks or equivalent. About 5 mm in diameter, about 32 cm long - Kim clamps, left curved jaws: needle clamps, left curved jaws, piece, straight handles with fingers and brakes or equivalent. About 5 mm in diameter, about 32 cm long - The blade is hooked, the function is about 10 mm long, single operation. About 5 mm, about 36 cm in length - The outer shell, metal or equivalent, with an insulation, with a Luer lock connector for watering. About 5 mm, about 36 cm long - Endoscopic surgery, plastic or equivalent, unlocked.
Nam Dinh Obstetrics and Gynecology Hospital
4
Babies hearing screening machine
1
Female
General requirements: - Main machine manufacturing year: 2024 or later - Equipment status: 100% new - Quality standards: ISO 13485: 2016 equivalent - Origin: European countries, G7 - Operating environment: + Operating temperature: 10ºC ~ 30ºC + Operating humidity: 30% ~ 75% - Power source: 220V, 50-60 Hz Minimum configuration includes: - Main machine: 01 unit - Probe with cable clip: 01 set - Electrode cable: 01 unit - Electrode patch: 01 bag - Skin gel: 01 bottle - Cotton: 01 bag - Probe testing compartment: 01 unit - Earbud connector: 05 units - Earbud set: 01 set - Battery charger: 01 set - User manual: 01 set Technical parameters: - Switchable between clinical analysis and screening modes - ≥ 3 built-in measurements on the machine: DPOAE, TEOAE, ABR - Storage on the main machine: ≥ 1000 tests or ≥ 1Gb - Ability to print wirelessly to a mini printer or equivalent. - DPOAE mode: measuring distorted product OAEs + Test configuration: ≥ 6 protocols, ≥ 8 parameters + Frequency range: 1 to ≤ 8 kHz, ≥ 12 frequencies + Frequency resolution: ≥ 4 points/octave + Stimulation level: ≥ 60/50 to ≤ 70/70 (dBSPL) + Passing criteria: ≥ 3 parameters + Signal to noise ratio: 1 to ≤ 10 dB per frequency band (∆1dB) + Frequency ratio F2 = 1.22 F1 - TEOAE mode: measuring transient Evoked OAEs + Test configuration: ≥ 2 protocols, ≥ 8 parameters + Frequency range: ≥ 1 to ≤ 4 kHz + Frequency resolution: approximately 1/2 octave + Stimulus level: 60 to ≤ 84 (∆1dB) (dBSPLpe) + Minimum pass criteria: 2, 3 or 4 1/2 octaves, wide or narrow band to pass + Signal to sound ratio: 6 dB ± 2 dB - ABR mode: ABR auditory brainstem response measurement + Stimulus level: can be set from ≥ 5 to ≤ 60 dBHL + Stimulus repetition rate: ≥ 50 to ≤ 93 Hz + Stimulus type: Click or Chirp. + CMRR amplifier: > 60 dB at 100 Hz - Multiple user logins can be created simultaneously with password protection with administrator control - Full patient data can be entered when needed - Data display: + Resolution: QVGA or better (≥ 320 x 240 pixels), ≥ 166 dpi + Technology: Color LCD, 16 bit (displaying 65K colors) or better - Power: rechargeable battery ≥ 1000 mAh lithium polymer or equivalent. - Charging time: When charging ≤ 3 hours to 90% battery When charging ≤ 4 hours to 100% battery
Nam Dinh Obstetrics and Gynecology Hospital
5
Body mass index meter
1
Machine
General requirements: - Year of producing the main machine: in 2024 onwards - Equipment status: 100% new - Quality standard: ISO 13485: 2016 is equivalent - Operating environment: + Operating temperature: 10ºC ~ 30ºC + Activity moisture: 30% ~ 75% - Power source used: 220V, 50-60 Hz Specifications Beer frequency: Minimum with frequencies 5, 50, 250kHz The age of users can install: from 6 to 99 years old or better Maximum load: ≥ 270kg; Division: ≤ 0.1kg The minimum connection interface has: RS232, USB, SD Overall analysis of body components: At least there are indicators: - Weight -BMI block index - % body fat -Organ fat level -Grease volume -Fatty mass -Mechanical mass -Close physique -Total body water - % of body water -ECW extracellular water -ICW intracellular water -ECW/TBW ratio -Phase angle -Basic BMR metabolism speed -Biological age -Directive of mineral bone volume Analyze each part of the body component: At least there are indicators: - % of the body fat -Assess the amount of body fat parts -The amount of body partial body -Evaluation of partial body muscles -Balancing the amount of body partial body -Electrical resistance each part of the body -Foot muscle score -The angle of each part of the body
Nam Dinh Obstetrics and Gynecology Hospital
Approval decision information
Approval date
03/09/2025
Approval decision code
338/CV-BVPSNĐ
Approval decision file

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Invite to quote equipment and subclinical machines". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Invite to quote equipment and subclinical machines" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 6

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second