Medical equipment quotation

Find: 16:29 21/04/2026

Bid info

Project name/purchase estimate
Shopping for medical equipment
Bid name
Shopping for medical equipment

Basic information of the request for quotation

Request for quotation code
RQ2600014218-00
Status
Posted
Name of request for quotation
Medical equipment quotation
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
Sub-zone 4, Xã Quỳnh Nhai, Province Sơn La
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Lèo Văn Mai
Position
Head of Pharmacy - Medical Equipment Department
Phone number
Address
Sub-zone 4, Quynh Nhai Commune

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 21/04/2026 16:25 To date 01/05/2026 08:00
Validity period of quotation
90 Day kể từ ngày 01/05/2026 08:00
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
Industrial washing machine
1
Female
Production year from 2026 onwards, 100% new product, manufacturer must meet ISO 9001 quality standards (or equivalent), power supply 380V; 50 Hz; 3P for electrical equipment, operating environment suitable for Vietnam's climate. Machine ≥ 50 kg, including 01 main machine, 01 power cord, 01 washing drum, 01 touch control panel, 01 rubber gasket, 01 water supply system and 01 user manual. Industrial washing machine with solid legs, horizontal machine shaft, maximum washing capacity ≥ 50 kg/batch, using 3-phase 380V power source, washing drum made of stainless steel or equivalent, drum diameter ≥ 1000 mm, drum depth ≥ 550 mm, drive motor ≥ 10 HP (7.5 kW), inverter ≥ 15 HP (11 kW), capacity water capacity of about 740 L ±10%, with at least 2 water supply lines and at least 1 drain valve, touch screen control or better, with balance check function to ensure safety, error display on screen, display of remaining time of the washing cycle and washing progress step by step, with chemical tank and automatic chemical supply port, with at least 8 groups of default washing programs, support for many different water levels, adjustable washing temperature settings, water supply time, chemical supply, washing time and spin time are all adjustable, overall dimensions do not exceed 1,550 x 1,350 x 1,800 mm.
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune
Set/ barrel
2
Electrocardiogram
1
Female
Manufactured from 2026 onwards, 100% new, from a manufacturer meeting ISO 13485 and CE or FDA quality standards, 220V; 50Hz power supply for electrical devices, suitable for the Vietnamese climate. Includes 1 main unit, 1 patient cable set, 6 rubber chest electrodes, 4 limb clamp electrodes, 1 roll of thermal printing paper, 1 power cable set, and 1 set of English and Vietnamese user manuals. The device is capable of transmitting and recording standard 12-lead ECGs including I, II, III, aVR, aVL, aVF, V1 to V6, supporting minimum recording modes of 6 channels, 6 channels + 1R, 3 channels, 3 channels + 1R, and 3 channels + 3R (R stands for rhythm lead), minimum sensitivity of 5, 10, and 20 mm/mV, recording speeds of 5, 10, 12.5, 25, and 50 mm/second, equipped with a minimum 7-inch TFT color LCD screen with a minimum resolution of 800 x 480, displaying real-time QRS rhythms in the range of ≤30 to ≥240 bpm, with audible indicators and warnings for electrode drop, low battery, or out of paper, a user interface including a membrane keypad and LCD touchscreen or equivalent, simultaneous 12-lead ECG signal acquisition, and high resolution. Minimum 24-bit A/D (0.29 μV/bit), minimum A/D sampling rate of 1000 samples/second/channel, minimum pacemaker signal sampling frequency of 8000 samples/second, CMRR greater than 100 dB, frequency response range from ≤0.05 Hz to ≥150 Hz, integrated digital filters including minimum 0.1 Hz baseline drift filter, minimum 25/35 Hz electromechanical noise filter, 50/60 Hz AC filter, and minimum 75, 100, 150 Hz high-frequency filter, data management functions including saving, deleting, reviewing, transmitting, and measuring, support for data transmission ports such as USB, USB memory card, and LAN Ethernet, capable of connecting to HIS systems with HL7, XML, SCP, PDF, JPG, PNG formats (via USB, FTP) and DICOM (PACS), integrated functionality Electrocardiogram (ECG) analysis and arrhythmia alert with the ability to automatically extend recording time from ≤20 to ≥60 seconds when detecting ventricular tachycardia or bradycardia, with audible and minimal display alerts for out-of-paper, low battery, or lead loss, using AC 100–240VAC ±10%, 50/60 Hz automatic power supply and built-in rechargeable battery. Other requirements: The device must be capable of storing a minimum of 4,000 records, connect and transmit data via computer, support data management with functions for saving, deleting, copying, reviewing, transferring, and measuring, support HIS formats including HL7, XML, SCP, PDF, JPG, PNG (USB, FTP) and DICOM (PACS), communicate via USB memory card, USB port, and LAN network, be able to connect to peripherals such as external printers, barcode readers, and card readers, have a rechargeable battery with a minimum operating time of 90 minutes, leakage current less than 10 µA, and comply with IEC 60601-1 and Class I electrical safety standards or equivalent.
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune
Set/ barrel
3
Operating table
1
Female
I. GENERAL REQUIREMENTS: Year of production from 2026 onwards, 100% new product, manufacturer meets ISO 13485 quality standards for main engine, power supply 220V; 50 Hz for electrical equipment, operating environment suitable for Vietnam's climate. II. CONFIGURATION REQUIREMENTS: Includes 01 pair of handrails, 01 cushion set, 01 power cord, 01 curtain frame, 01 foot switch and 01 English and Vietnamese user manual. III. TECHNICAL SPECIFICATIONS: The device has the ability to adjust the position up and down, supports neat and simple electrical wiring management, the table top is made of aluminum or equivalent material and is machined/folded at a 90° right angle, the base is made from special anti-rust FRP material or equivalent, the table size is about 1,900 mm in length and 500 mm in width with an error of ±10%, using an electric hydraulic lifting system or equivalent. equivalent, AC power source 220V/50–60 Hz, height adjustable from ≤620 mm to ≥840 mm, legs can be lowered at least 90°, backrest can be raised at least 80° and lowered up to 15°, minimum load is ≥135 kg.
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune
Set/ barrel
4
Dental X-ray machine
1
Female
Manufactured from 2026 onwards, 100% new, the manufacturer must meet ISO 13485 and CE or FDA quality standards, the equipment must comply with ANSI/AAMI ES60601-1 (2005) + AMD 1 (2012), CAN/CSA-C22.2 No. 60601-1 (2014), IEC 60601-1-3 (2008), IEC 60601-2-63 (2012), 21 CFR 1020.30, 31, 33 and NEMA Standard publication PS 3.1-3.18, power supply 220V; 50 Hz for electrically powered devices, suitable for the Vietnamese climate. The main unit with standard accessories includes: 1 unit, 1 chin rest/bite block, 1 chin rest for toothless patients, 1 chin rest for sinus and TMJ, 1 pair of temporal bone supports, 1 Carpus plate, 1 box of sanitary covers for the bite block, 1 computer set, 1 set of 2D image viewing and diagnostic software, and 1 set of user, maintenance, and repair manuals in English and Vietnamese. The main unit is a digital X-ray machine capable of vertical movement ≥700 mm, with dimensions of approximately 990 × 1247 × 2320 mm and an accuracy of ±1%, weighing approximately 90 kg ±1%. The scanning times for various modes include: standard panoramic ≤10.5 seconds, orthogonal panoramic ≤10.5 seconds, bite-wing ≤7.5 seconds, pediatric panoramic ≤9 seconds, unilateral TMJ opening/closing ≤5 seconds, anterior/posterior TMJ opening/closing ≤6 seconds, anterior sinus ≤8 seconds, unilateral sinus ≤5 seconds, unilateral/anterior/posterior/submental (SMV)/Waters View/Carpus ≤13 seconds, and full skull ≤17 seconds. The focal point is ≤0.5 mm, and the Ceph FOV size is... With a scan size of 21×23 cm (8.3×9.1 inch) for LAT, PA, SMV, Waters View, Carpus and 27×23 cm (10.6×9.1 inch) for Full LAT, grayscale ≤14 bits. The X-ray generator has a rated power ≥0.9 kW, a high-voltage generator operating in the range of 50–90 kV and 4–10 mA with automatic cooling ≤60°C, a focal tube size ≤0.5 mm, target angle ≤5 degrees, anode enthalpy ≤35 kJ, voltage and current in the range of ≤50 to ≥90 kVp and ≤4 to ≥10 mA. The X-ray detector system consists of a Pano section with pixel size ≥100 μm, active area approximately 6×150 mm ±10%, frame rate ≥300 frames/second, sensor size approximately 175 × 86 × 21 mm ±10%, and a Ceph section with pixel size ≥100 μm, active area approximately 6×230 mm ±10%, frame rate ≥200 frames/second, sensor size approximately 251 × 69 × 27 mm ±10%. The patient management and image viewing software allows connection to the main unit and sensors, supports saving and viewing images, creating and retrieving patient information, controlling imaging modes, providing approximately 200 treatment procedures with animated images, rapid implant simulation, image management and viewing with functions such as zooming/zooming, image analysis, drag-and-drop, viewing multiple images simultaneously, screen-fit display mode, and also supports image processing such as adjusting brightness, contrast, smoothness, zooming in/out, measuring distance and angle, cropping, flipping images, creating annotations, drawing on images, screen capturing, and image filtering. Standard accessories include a computer with a minimum Core i3 CPU, ≥4 GB RAM, ≥500 GB HDD, one 21-inch or 1920 × 1080 resolution medical-grade color monitor, and user, maintenance, and repair manuals in both English and Vietnamese.
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune
Set/ barrel
5
Foot massage system
1
Female
The equipment includes 01 herbal compartment, 01 control screen, at least 05 automatic programs, 01 automatic water heater, at least 05 basic massage rollers and 01 user manual. The device operates with a rated voltage of 100–240 VAC, 50–60 Hz, maximum power not exceeding 550 W, minimum capacity of 7 liters, equipped with at least 05 massage rollers capable of rotating from 180° or more, touch screen control screen with high quality tempered glass surface or equivalent material, heating system capable of automatically heating and maintaining water temperature in the range of 30 to 50°C, integrates red light therapy technology, has at least 05 automatic operating modes, is equipped with moving wheels and convenient drainage port, safety system includes at least 02 layers of insulation and heat insulation, and integrates an independent herbal compartment.
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune
Set/ barrel
Approval decision information
Approval date
20/04/2026
Approval decision code
Số 135/CV/BVĐK
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Medical equipment quotation". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Medical equipment quotation" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 10

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second