Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Industrial washing machine |
1 |
Female |
Production year from 2026 onwards, 100% new product, manufacturer must meet ISO 9001 quality standards (or equivalent), power supply 380V; 50 Hz; 3P for electrical equipment, operating environment suitable for Vietnam's climate. Machine ≥ 50 kg, including 01 main machine, 01 power cord, 01 washing drum, 01 touch control panel, 01 rubber gasket, 01 water supply system and 01 user manual. Industrial washing machine with solid legs, horizontal machine shaft, maximum washing capacity ≥ 50 kg/batch, using 3-phase 380V power source, washing drum made of stainless steel or equivalent, drum diameter ≥ 1000 mm, drum depth ≥ 550 mm, drive motor ≥ 10 HP (7.5 kW), inverter ≥ 15 HP (11 kW), capacity water capacity of about 740 L ±10%, with at least 2 water supply lines and at least 1 drain valve, touch screen control or better, with balance check function to ensure safety, error display on screen, display of remaining time of the washing cycle and washing progress step by step, with chemical tank and automatic chemical supply port, with at least 8 groups of default washing programs, support for many different water levels, adjustable washing temperature settings, water supply time, chemical supply, washing time and spin time are all adjustable, overall dimensions do not exceed 1,550 x 1,350 x 1,800 mm. |
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune |
Set/ barrel |
||
2 |
Electrocardiogram |
1 |
Female |
Manufactured from 2026 onwards, 100% new, from a manufacturer meeting ISO 13485 and CE or FDA quality standards, 220V; 50Hz power supply for electrical devices, suitable for the Vietnamese climate. Includes 1 main unit, 1 patient cable set, 6 rubber chest electrodes, 4 limb clamp electrodes, 1 roll of thermal printing paper, 1 power cable set, and 1 set of English and Vietnamese user manuals. The device is capable of transmitting and recording standard 12-lead ECGs including I, II, III, aVR, aVL, aVF, V1 to V6, supporting minimum recording modes of 6 channels, 6 channels + 1R, 3 channels, 3 channels + 1R, and 3 channels + 3R (R stands for rhythm lead), minimum sensitivity of 5, 10, and 20 mm/mV, recording speeds of 5, 10, 12.5, 25, and 50 mm/second, equipped with a minimum 7-inch TFT color LCD screen with a minimum resolution of 800 x 480, displaying real-time QRS rhythms in the range of ≤30 to ≥240 bpm, with audible indicators and warnings for electrode drop, low battery, or out of paper, a user interface including a membrane keypad and LCD touchscreen or equivalent, simultaneous 12-lead ECG signal acquisition, and high resolution. Minimum 24-bit A/D (0.29 μV/bit), minimum A/D sampling rate of 1000 samples/second/channel, minimum pacemaker signal sampling frequency of 8000 samples/second, CMRR greater than 100 dB, frequency response range from ≤0.05 Hz to ≥150 Hz, integrated digital filters including minimum 0.1 Hz baseline drift filter, minimum 25/35 Hz electromechanical noise filter, 50/60 Hz AC filter, and minimum 75, 100, 150 Hz high-frequency filter, data management functions including saving, deleting, reviewing, transmitting, and measuring, support for data transmission ports such as USB, USB memory card, and LAN Ethernet, capable of connecting to HIS systems with HL7, XML, SCP, PDF, JPG, PNG formats (via USB, FTP) and DICOM (PACS), integrated functionality Electrocardiogram (ECG) analysis and arrhythmia alert with the ability to automatically extend recording time from ≤20 to ≥60 seconds when detecting ventricular tachycardia or bradycardia, with audible and minimal display alerts for out-of-paper, low battery, or lead loss, using AC 100–240VAC ±10%, 50/60 Hz automatic power supply and built-in rechargeable battery. Other requirements: The device must be capable of storing a minimum of 4,000 records, connect and transmit data via computer, support data management with functions for saving, deleting, copying, reviewing, transferring, and measuring, support HIS formats including HL7, XML, SCP, PDF, JPG, PNG (USB, FTP) and DICOM (PACS), communicate via USB memory card, USB port, and LAN network, be able to connect to peripherals such as external printers, barcode readers, and card readers, have a rechargeable battery with a minimum operating time of 90 minutes, leakage current less than 10 µA, and comply with IEC 60601-1 and Class I electrical safety standards or equivalent. |
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune |
Set/ barrel |
||
3 |
Operating table |
1 |
Female |
I. GENERAL REQUIREMENTS: Year of production from 2026 onwards, 100% new product, manufacturer meets ISO 13485 quality standards for main engine, power supply 220V; 50 Hz for electrical equipment, operating environment suitable for Vietnam's climate. II. CONFIGURATION REQUIREMENTS: Includes 01 pair of handrails, 01 cushion set, 01 power cord, 01 curtain frame, 01 foot switch and 01 English and Vietnamese user manual. III. TECHNICAL SPECIFICATIONS: The device has the ability to adjust the position up and down, supports neat and simple electrical wiring management, the table top is made of aluminum or equivalent material and is machined/folded at a 90° right angle, the base is made from special anti-rust FRP material or equivalent, the table size is about 1,900 mm in length and 500 mm in width with an error of ±10%, using an electric hydraulic lifting system or equivalent. equivalent, AC power source 220V/50–60 Hz, height adjustable from ≤620 mm to ≥840 mm, legs can be lowered at least 90°, backrest can be raised at least 80° and lowered up to 15°, minimum load is ≥135 kg. |
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune |
Set/ barrel |
||
4 |
Dental X-ray machine |
1 |
Female |
Manufactured from 2026 onwards, 100% new, the manufacturer must meet ISO 13485 and CE or FDA quality standards, the equipment must comply with ANSI/AAMI ES60601-1 (2005) + AMD 1 (2012), CAN/CSA-C22.2 No. 60601-1 (2014), IEC 60601-1-3 (2008), IEC 60601-2-63 (2012), 21 CFR 1020.30, 31, 33 and NEMA Standard publication PS 3.1-3.18, power supply 220V; 50 Hz for electrically powered devices, suitable for the Vietnamese climate. The main unit with standard accessories includes: 1 unit, 1 chin rest/bite block, 1 chin rest for toothless patients, 1 chin rest for sinus and TMJ, 1 pair of temporal bone supports, 1 Carpus plate, 1 box of sanitary covers for the bite block, 1 computer set, 1 set of 2D image viewing and diagnostic software, and 1 set of user, maintenance, and repair manuals in English and Vietnamese. The main unit is a digital X-ray machine capable of vertical movement ≥700 mm, with dimensions of approximately 990 × 1247 × 2320 mm and an accuracy of ±1%, weighing approximately 90 kg ±1%. The scanning times for various modes include: standard panoramic ≤10.5 seconds, orthogonal panoramic ≤10.5 seconds, bite-wing ≤7.5 seconds, pediatric panoramic ≤9 seconds, unilateral TMJ opening/closing ≤5 seconds, anterior/posterior TMJ opening/closing ≤6 seconds, anterior sinus ≤8 seconds, unilateral sinus ≤5 seconds, unilateral/anterior/posterior/submental (SMV)/Waters View/Carpus ≤13 seconds, and full skull ≤17 seconds. The focal point is ≤0.5 mm, and the Ceph FOV size is... With a scan size of 21×23 cm (8.3×9.1 inch) for LAT, PA, SMV, Waters View, Carpus and 27×23 cm (10.6×9.1 inch) for Full LAT, grayscale ≤14 bits. The X-ray generator has a rated power ≥0.9 kW, a high-voltage generator operating in the range of 50–90 kV and 4–10 mA with automatic cooling ≤60°C, a focal tube size ≤0.5 mm, target angle ≤5 degrees, anode enthalpy ≤35 kJ, voltage and current in the range of ≤50 to ≥90 kVp and ≤4 to ≥10 mA. The X-ray detector system consists of a Pano section with pixel size ≥100 μm, active area approximately 6×150 mm ±10%, frame rate ≥300 frames/second, sensor size approximately 175 × 86 × 21 mm ±10%, and a Ceph section with pixel size ≥100 μm, active area approximately 6×230 mm ±10%, frame rate ≥200 frames/second, sensor size approximately 251 × 69 × 27 mm ±10%. The patient management and image viewing software allows connection to the main unit and sensors, supports saving and viewing images, creating and retrieving patient information, controlling imaging modes, providing approximately 200 treatment procedures with animated images, rapid implant simulation, image management and viewing with functions such as zooming/zooming, image analysis, drag-and-drop, viewing multiple images simultaneously, screen-fit display mode, and also supports image processing such as adjusting brightness, contrast, smoothness, zooming in/out, measuring distance and angle, cropping, flipping images, creating annotations, drawing on images, screen capturing, and image filtering. Standard accessories include a computer with a minimum Core i3 CPU, ≥4 GB RAM, ≥500 GB HDD, one 21-inch or 1920 × 1080 resolution medical-grade color monitor, and user, maintenance, and repair manuals in both English and Vietnamese. |
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune |
Set/ barrel |
||
5 |
Foot massage system |
1 |
Female |
The equipment includes 01 herbal compartment, 01 control screen, at least 05 automatic programs, 01 automatic water heater, at least 05 basic massage rollers and 01 user manual. The device operates with a rated voltage of 100–240 VAC, 50–60 Hz, maximum power not exceeding 550 W, minimum capacity of 7 liters, equipped with at least 05 massage rollers capable of rotating from 180° or more, touch screen control screen with high quality tempered glass surface or equivalent material, heating system capable of automatically heating and maintaining water temperature in the range of 30 to 50°C, integrates red light therapy technology, has at least 05 automatic operating modes, is equipped with moving wheels and convenient drainage port, safety system includes at least 02 layers of insulation and heat insulation, and integrates an independent herbal compartment. |
Quynh Nhai Regional General Hospital, sub -area 4, Quynh Nhai commune |
Set/ barrel |
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Bệnh viện Đa khoa khu vực Quỳnh Nhai:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Bệnh viện Đa khoa khu vực Quỳnh Nhai:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.