Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Cold centrifugal machine with blood bags |
1 |
Female |
REFRIGERATED BLOOD BAG CENTRIFUGE 1. General Requirements - 100% new equipment - Year of manufacture: 2025 or later - Origin: G7 group (Applies to the main unit) - Manufacturer meets the following standards (Applies to the main unit): ISO 13485 or equivalent - Power supply: 220V/50 Hz or 380V/3 phase/50Hz - Operating environment: + Maximum temperature: ≥ 30°C + Maximum humidity: ≥ 75% 2. Minimum Configuration - Main unit with accessories as per manufacturer's standard: 1 unit - Swing-out rotor with wind shield (or equivalent): 1 unit - Swing-out bucket: 1 set - Blood bag adapter: 1 set, including all necessary adapters for simultaneous centrifugation of at least 12 250 mL blood bags or simultaneously a minimum of 12 bags of 350 mL blood - Barcode reader - User manual; Technical documentation for equipment repair and maintenance: English and Vietnamese: 1 set. 3. Features and Technical Requirements Technical Specifications - Floor-standing refrigerated blood bag centrifuge used for centrifuging blood bags, separating blood components, and providing refrigerated blood bag centrifugation. - Microprocessor-based control and digital display of parameters such as speed, time, temperature, acceleration/deceleration levels, and running programs. - TFT or LCD display or better. - Connectivity to a central data management system. - Program setting function. - Blood bag centrifuge with a maximum capacity of ≥ 12 blood bags. - Acceleration/deceleration control and display in linear or square curve or equivalent form. - Centrifuge height can be adjusted relative to the floor for balance and stability. Main Machine Specifications - Maximum speed ≥ 4,000 rpm - Maximum centrifugal force ≥ 5.100 xg - Number of acceleration programs ≥ 10; deceleration programs: ≥ 10 programs - Displays speed and centrifugal force on screen - Number of programs: ≥ 50 programs - Setting time up to ≥ 99 hours: 59 minutes - Time increment: approximately 1 second or 60 seconds - Cooling temperature range: ≤ -9°C to ≥ +40°C - Temperature increment: approximately 1°C Safety functions - Imbalance detection function - Audible and visual/light warning - Emergency lid opening function in case of malfunction - Centrifuge meets international safety standards such as EN61010 or equivalent |
Ninh Binh General Hospital |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Bệnh viện đa khoa tỉnh Ninh Bình:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Bệnh viện đa khoa tỉnh Ninh Bình:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.