| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Glucose testing chemicals |
20.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include: +Buffer PH: 6.5-7.5; +Glucose oxidase (GOD) ≥ 15,000U/L 2. Technical characteristics and features: Used to determine Glucose concentration in serum, plasma, urine and CSF. Optical enzymatic method, endpoint measurement. - Lowest detection limit: ≤3.0 mg/dL - Linearity without dilution: ≥ 400 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
2 |
Cholesterol testing chemicals |
20.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include: +Buffer PH: 6.5-7.5; + Cholesterol esterase ≥ 180 U/L + Cholesterol oxidase ≥ 100 U/L + Peroxidase ≥ 200 U/L 2. Characteristics and technical features: Used to determine cholesterol concentration in serum. End point measurement method. - Lowest detection limit: ≤ 3.0 mg/dL - Linearity without dilution: ≥ 600 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
3 |
Triglycerid testing chemicals |
20.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include: + PH buffer: 6.5-7.5; + Adenosine Triphosphate (ATP) ≥ 2mmol/L + Glycerol Kinase ≥ 400 U/L + Peroxidase ≥ 500 U/L + Glycerol–3-phosphate oxidase ≥ 2000 U/L 2. Characteristics and technical features: Used to determine the concentration of Triglycerides in serum and plasma. End point measurement method. - Lowest detection limit: ≤ 3.0 mg/dL - Linearity without dilution: ≥ 1000 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
4 |
Urea testing chemicals |
20.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include: + PH buffer: 7.5-8.0; + Urease ≥ 6500 U/L + Adenosine diphosphate (ADP) ≤ 1.6 mmol/L, + Glutamate dehydrogenase (GLDH) ≥ 800 U/L, + Nicotinamide adenine dinucleotide (NADH) ≤ 1.6 mmol/L, 2. Characteristics and technical features: Used to determine Urea concentration in serum, plasma or urine. Measuring method: Two Point Kinetic. - Lowest detection limit: ≤ 3.0 mg/dL - Linearity without dilution: ≥ 300 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
5 |
Creatinine testing chemicals |
20.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include: + Sodium hydroxide ≤ 800 mmol/L, + Picric acid ≤ 24 mmol/L, 2. Technical characteristics and features: Used to determine Creatinine concentration in serum, plasma or urine. Jaffe measurement method - Lowest detection limit: ≤ 0.2 mg/dL - Linearity without dilution: ≥ 10 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
6 |
HDL cholesterol test |
4.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents. 2. Technical characteristics and features: Used to determine HDL Cholesterol concentration in serum and plasma. Measurement method: Colorimetric, End Point Reaction - Lowest detection limit: ≤ 2.0 mg/dL - Linearity when undiluted: ≥ 150 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
7 |
LDL cholesterol test |
500 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include: + PH buffer: 6.5-7.5; + Cholesterol esterase: ≥ 1500 U/L; + Cholesterol oxidase: ≥ 1500 U/L; + Peroxidase: ≥ 1300 U/L 2. Technical characteristics and features: Used to determine LDL Cholesterol concentration in serum and plasma. Measurement method: Colorimetric, End Point Reaction - Lowest detection limit: ≤ 4.0 mg/dL - Linearity when undiluted: ≥ 250 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
8 |
GOT/AST testing chemicals |
20.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Reagents include: + PH buffer: 7.5-8.5; + Lactate Dehydrogenase (LDH): ≥ 650 U/L; + Nicotinamide Adenine Dinucleotide (NADH): ≤0.3 mmol/L; + Malate Dehydrogenase (MDH): ≥ 600 U/L 2. Technical characteristics and features: Used to determine SGOT concentration in serum and plasma. Measurement method: kinetic - Lowest detection limit: ≤ 2.0 U/L - Linearity without dilution: ≥ 400 U/L 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
9 |
Chemicals for GPT/ALT test |
20.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Reagents include: + PH buffer: 7.5-8.5; + Lactate Dehydrogenase (LDH): ≥ 800 U/L; + Nicotinamide Adenine Dinucleotide (NADH): ≤ 0.3 mmol/L 2. Technical characteristics and features: Used to determine SGPT concentration in serum and plasma. Kinetic measurement method - Lowest detection limit: ≤ 2.0 U/L - Linearity without dilution: ≥ 500 U/L 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
10 |
GGT test chemicals |
3.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Reagents include: + PH buffer: 6.5-8.5; + Glycylglycine: ≥ 100 mmol/L; 2. Technical characteristics and features: Used to determine Gamma GT concentration in serum and plasma. Kinetic measurement method - Lowest detection limit: ≤ 4.0 U/L - Linearity without dilution: ≥ 200 U/L 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
11 |
Direct bilirubin testing chemicals |
3.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Reagents include: + HCL ≤ 0.5M ; 2. Technical characteristics and features: Used to quantitatively determine Bilirubin in serum or plasma, Diazo measurement method, endpoint measurement - Lowest detection limit: ≤ 0.1 mg/dL - Linearity when undiluted: ≥ 9 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
12 |
Total bilirubin testing chemicals |
3.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Reagents include: + HCL ≤ 0.5M; + Diazonium derivative, using diazo salts: ≤3mmol 2. Technical characteristics and features: Used to quantitatively determine Bilirubin in serum or plasma, Diazo measurement method, endpoint measurement - Lowest detection limit: ≤ 2 mg/dL - Linearity when undiluted: ≥ 20 mg/dl 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
13 |
Amylase testing chemicals |
1.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Reagents; Chemical buffer PH 6.5-7.5 2. Characteristics and technical features: Used to quantitatively determine Amylase in serum or plasma. Kinematic measurement method. - Lowest detection limit: ≤3 U/L - Linearity when undiluted: ≥ 1,500U/L 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
14 |
Protein quantitative chemicals |
2.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; -Standard substance; - Reagents include; + Sodium-potassium tartrate ≤ 24mmol; + Potassium iodide ≤24mmol; 2. Technical characteristics and features: Used to quantitatively determine total Protein in serum or plasma. Colorimetric, Endpoint, Increasing Reaction, Biuret measurement methods. - Lowest detection limit: ≤0.3 g/dL - Linearity when undiluted: ≥ 12 g/dL 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
15 |
Chemical testing albumin |
2.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include; + PH buffer 3.5-4.5 + Bromcresol green: ≤ 0.8 g/L; 2. Technical characteristics and features: Used to quantitatively determine Albumin in serum or plasma. Bromocresol blue measurement method, endpoint measurement. - Lowest detection limit: ≤0.1 g/dL - Linearity when undiluted: ≥ 6 g/dL 3. Quality criteria: ISO or equivalent ' |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
16 |
Uric acid tests |
10.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include; + Buffer PH 7.0-8.0 + Uricase: ≤ 350 U/L; 2. Technical characteristics and features: Used to quantify uric acid in serum, plasma and urine. Colorimetric, Endpoint, Trinder, Increasing Reaction, Enzymatic measurement methods - Lowest detection limit: ≤0.2 mg/dL - Undiluted linearity: ≥ 25 mg/dL 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
17 |
Chemicals quantitative test CRP _HS |
5.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include; + PH buffer 6.5-8.5 + Sodium azide: ≤ 1.0 g/L; 2. Characteristics and technical features: Used to diagnose the risk of cardiovascular disease by quantifying C-reactive protein (CRP_hs) in human serum. Immunoturbidimetric method - Lowest detection limit: ≤2.0 mg/L - Linearity when undiluted: ≥ 10 mg/L 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
18 |
Ethanol quantitative testing chemicals |
500 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagent: Alcohol dehydrogenase (ADH) ≥ 25,000 IU/L 2. Technical characteristics and features: Used to quantify alcohol concentration in human serum and plasma. Method: Enzymatic UV test with alcohol dehydrogenase (ADH) - Lowest detection limit: ≤ 10 mg/dL 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
19 |
Standard chemicals Ethanol level 1 |
50 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: Ethanol level 1 control chemicals 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
20 |
Chemical standard Ethanol level 2 |
50 |
ML |
'1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: Ethanol level 2 control chemicals 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
21 |
CK-MB quantitative testing chemicals |
1.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; - Standard substance; - Reagents include: + PH buffer: 6.0-7.5; + Glucose ≤ 25 mM + Creatine phosphate ≥ 22mmol/L; + Adenosine Diphosphate (ADP) ≥ 3.0 mmol/L + Nicotinamide Adenine Dinucleotide Phosphate (NADP) ≤ 3.0 mmol/L 2. Characteristics and technical features: used to quantify CK-MB in serum and plasma. Kinematic measurement method. - Lowest detection limit: ≤ 4 U/L; - Linearity without dilution: ≥ 600 U/L 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
22 |
Standardization of normal biochemical testing machines |
200 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; 2, Technical characteristics and features: used to internally check normal biochemical levels. - Calibration used for ≥ 31 routine biochemical tests. 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
23 |
Standard chemicals for biochemical testing machines |
200 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; 2, Technical characteristics and features: used for internal biochemical testing of pathological levels - Calibration used for ≥ 31 routine biochemical tests. 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
24 |
Chemical washing machine biochemistry |
4.000 |
ML |
1. Ingredients: - Compatible with CA400 automatic biochemical machine; 2. Technical characteristics and features: Used to clean sample needles and cuvettes on automatic biochemical analyzers 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
25 |
Sample Cup |
10.000 |
ML |
1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: Plastic cup, disposable 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
26 |
HDL/LDL calibration chemicals |
50 |
ML |
'1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: HDL/LDL calibration chemicals for biochemical testing 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
27 |
CRP_hs calibration chemical for biochemical testing machines |
40 |
ML |
'1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: 5-level calibration chemicals for CRP_hs. 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
28 |
CRP_hs control chemical for level 1 biochemical testing machine |
200 |
ML |
'1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: Control chemicals for CRP_hs, ASO, RF level 1 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
29 |
CRP_hs control chemical for level 2 biochemical testing machine |
200 |
ML |
'1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: Control chemicals for CRP_hs, ASO, RF level 2 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
30 |
Cute chemical CKMB for biochemical testing machines |
40 |
ML |
'1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: CKMB calibration chemicals for biochemical testing machines 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
|||
31 |
Calibrated chemicals for biochemical testing machines |
40 |
ML |
'1. Ingredients: - Compatible with automatic biochemical machine CA400; 2. Technical characteristics and features: Chemicals used to calibrate biochemical testing machines 3. Quality criteria: ISO or equivalent |
Binh Long Regional Medical Center, No. 82, Phan Boi Chau, Binh Long Ward, Dong Nai Province. |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Trung tâm y tế khu vực Bình Long:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Trung tâm y tế khu vực Bình Long:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.