Purchasing assets from the 2026 public service development fund

Find: 17:17 03/08/2026

Bid info

Project name/purchase estimate
Purchasing assets from the 2026 public service development fund
Bid name
Purchasing assets from the 2026 public service development fund

Basic information of the request for quotation

Request for quotation code
RQ2600031294-00
Status
Posted
Name of request for quotation
Purchasing assets from the 2026 public service development fund
Unit requesting quote
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
New street, Phường Đồng Nguyên, Province Bắc Ninh
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Nguyễn Duy Luyện
Position
Secretary of the Price Planning Team
Phone number
Address
Clerical department - Tu Son General Hospital, Pho Moi - Dong Nguyen ward - Bac Ninh province.

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 03/08/2026 17:16 To date 13/08/2026 17:00
Validity period of quotation
120 Day kể từ ngày 13/08/2026 17:00
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
General digital X -ray machine
1
Machine
a. General requirements: - Year of manufacture: 2026 - Machine quality: 100% new, unused - Standard compliance: ISO 13485 - Power supply: 3-phase, 380V, 50/60Hz - Origin: + Main unit: Manufactured in a country belonging to the Organization for Economic Cooperation and Development (OECD). + Digital X-ray image receiver (FPD): Manufactured in a G7 country. + X-ray tube: Manufactured in a G7 country. - Operating environment: + Maximum temperature: ≥ 35oC + Maximum humidity: ≥ 70% b. Configuration: Digital X-ray system for general imaging, 2-sensor type, configuration includes: - X-ray machine with accessories including: + High-voltage generator: 1 unit + X-ray tube: 1 unit + Floor-mounted X-ray tube column: 1 set + Beam collimator: 1 unit + Patient table: 1 unit + Chest X-ray stand: 1 unit - Digital X-ray image receiver (FPD): 2 sets - Image acquisition and processing software: 1 set - Image receiver connection box: 2 units - Computer workstation: 1 set - 2 kVA Online UPS: 1 unit - X-ray warning light: 1 unit - English and Vietnamese user manual, English and Vietnamese maintenance manual: 1 set. Technical Specifications: * Digital High-Frequency X-ray Machine - High-Voltage Generator + Scanning Power: ≥ 50kW + Frequency: ≥ 60 kHz + Scanning Voltage: 40kV - 150kV + Scanning Current: ≥ 630mA + mA Range: 10 – 630mA + mAs Range: ≥ 630 mAs + Scanning Time: From 0.1ms – ≤ 10 seconds + Scanning Parameter Selection: By kV, mA, s, mAs + Preset Scanning Programs: ≥ 216 programs - X-ray Tube + Number of Focal Spots: 2 + Focal Size: - Small: ≤ 0.6 mm - Large: ≤ 1.2 mm + Anode Heat Resistance: ≥ 300 kHU. + Anode heat dissipation rate: ≥ 1226 HU/second. + Maximum voltage of the tube: ≥ 150 kV + Beam opening angle: ≤ 120° - Floor-mounted X-ray tube column + Simultaneous up/down and left/right movement sensor + LCD screen displaying SID distance and angle between the X-ray tube and the digital receiver + Tube travel distance along the vertical axis of the support column: ≥ 1500 mm + Lateral travel distance: ≥ 1860 mm + Vertical tube rotation angle: ± 180° + Horizontal tube rotation angle: ± 90° - Beam collimator + Manual field control + Illumination lamp: Halogen or LED type, brightness: ≥ 160 lux at SID 100 cm + Lamp auto-off time: ≥ 30 seconds + Minimum maximum field size: ≥ 43 cm x 43 cm The SID distance is 100cm. + Filter: Equivalent to: ≥ 1.5mmAl + Minimum aperture: ≤ 1 cm x 1 cm (SID 100 cm) - Patient table + Four-way movable type, with electromagnetic brake, controlled by foot pedal + Table surface with X-ray filter mesh with a ratio of: ≥ 215 lines/cm, ratio: ≥ 10:1 + Table height: ≥ 650mm + Distance from table surface to image sensor: ≥ 80mm + Horizontal travel range: ± ≥ 105mm + Vertical travel range: ± ≥ 500 mm + Minimum table size: ≥ 1890 x 800 mm + Minimum patient weight: ≥ 150 kg - Standing chest X-ray stand + Bucky stand for image sensors with dimensions from: 18 x 24 cm to ≥ 43 x 43cm. + Vertical movement: ≥ 1500 mm + Up/down control range: from 350 mm to ≥ 1850 mm. + Tabletop with X-ray filter: ≥ 215 lines, ratio: ≥ 10:1 + Motorized up/down movement + Uses electromagnetic brake * Digital X-ray image receiver (FPD) - Sensor material made of CsI or material with equivalent or better signal reception performance - Active area: ≥ 426 x 425 mm - Overall dimensions: ≥ 459 x 459 x 15 mm - Pixel matrix: ≥ 2800 x 3036 pixels - Resolution: ≥ 3.7 Lp/mm - Pixels: ≤ 140µm - A/D conversion: ≤ 16 bits - Weight: ≤ 4.3 kg * Image processing software - Software for image display and processing - Software for image stitching - Software for left-right marking - Functions Image rotation - Software for measuring dimensions and distances, measuring length and angles using freehand lines and displaying them on the screen - Digital image processing functions: image contrast; image rotation; image zooming; marking on film, * Image processing workstation - Processing, storing and sharing images - Processor: ≥ Intel Core i5 CPU or higher - Screen size: Medical monitor ≥ 27", resolution ≥ 8Mbps - Hard drive/storage: ≥ 1TB/ SSD: ≥ 256G - RAM: ≥ 16 GB - DVD/CR-ROM image recorder - Keyboard and mouse - Licensed Windows operating system * DICOM connection: - Minimum of the following functions: + DICOM Storage + DICOM Print + DICOM 3.0
Tu Son General Hospital
2
General ultrasound machine
1
Machine
a. General Requirements: - 100% new machine, never used - Year of manufacture: 2026 or later - Main machine quality standard: ISO 13485, EU or EC or equivalent - Operating environment: + Maximum temperature ≥ 30°C + Maximum humidity ≥ 70% - Power supply: Suitable for voltage in Vietnam b. Configuration: - Main machine: 1 unit - Multi-frequency linear detector: 1 unit - English and Vietnamese user manual: 1 set of accessories - 1KVA UPS: 1 unit - Thermal printer: 1 unit c. Technical Specifications: - Scanning methods available: Electronic convex; Electronic linear; Main Unit 1. Main Unit - Integrated design on a trolley - Number of active transducer sockets: ≥ 2 ports - Internal hard drive capacity: ≥ 256 GB - Image display depth up to ≥ 33 cm - Frame rate: ≥ 1780 frames/second - Number of digitization processing channels: ≥ 500,000 channels - Frequency range: ≤ 2 to ≥ 13 MHz (Depends on transducer) - Ultrasound beam transmission and reception technique from multiple directions (Spatial composite imaging) ≥ 9 scanning angles or Non-focal ultrasound technology. - Dynamic range: ≥ 265 dB - Tissue harmonic imaging - Continuous automatic image optimization - Automatic real-time Doppler spectrum calculation 2. Display: - Display screen: + Size ≥ 21.5 inches + Resolution: ≥ 1920 x 1080 pixels 3. Transducer - Multi-frequency linear transducer + Application: blood vessels, small organs, musculoskeletal system + Frequency range: ≤ 5 to ≥ 12 MHz + Number of transducers: ≥ 128 - Minimum operating modes: + B-mode, Encoded or inverted tissue harmonics, M-mode, Color stream mode, Power Doppler mode, Pulsed Doppler mode Scanning parameters: - B-mode scanning parameters: + Amplification: maximum ≥ 80 dB + Dynamic range: approximately ≤ 40 - ≥ 90 dB + Maximum current density: ≥ 5 steps + Average frame ≥ 8 levels or stability ≥ 8 levels + Selectable frequency (with one probe and depending on the probe) up to ≥ 4 options. + Grayscale level map: ≥ 6 types + Spot noise filtering: ≥ 6 levels + Compression ≥ 6 steps or Low-frequency feedback reduction - Mode M scanning parameters: + Gain: range from ≤ -20 dB to ≥ 20 dB - Color flow mode scanning parameters: + Flow density in zoom mode: ≥ 5 or flow density (normal): ≥ 8 + Frame average or stability: ≥ 7 steps + PRF: range ≤ 0.1 – ≥ 19.8 kHz + Color map (including velocity map) ≥ 19 types, depending on transducer and application or color code ≥ 15 types + Package size: ≤ 10 - ≥ 20 (depending on transducer and application) or adjustable by at least 3 levels + Selectable frequency (with one transducer) (and depending on the transducer) up to ≥ 4 steps or selectable frequency range with all transducer types): ≤ 1.9 - ≥ 10 MHz, (equivalent to ≥ 12 steps) + Filtering: ≥ 4 steps (levels), depending on the transducer and application + Spot noise compression or removal of body movement effects: ≥ 3 steps + Spatial filtering or smoothing: ≥ 5 steps + Color accumulation: yes - Pulsed Doppler Mode Scanning Parameters + Gain adjustment range: ≥ 60 dB + Pulse repetition frequency (PRF): ≤ 0.6– ≥ 27.5 KHz + Filtering: ≤ 6- ≥ 5000 Hz or ≥ 12 adjustment steps (depending on the transducer) + Spectrum inversion: On/Off + Compression: ≤ 0.5 - ≥ 2.4 or reduced low-frequency feedback + Trace sensitivity: 0 - ≥ 40 or enhanced grayscale - Power Doppler Mode scanning parameters + Color maps: ≥ 14 maps + Pulse repetition frequency (PRF): from ≤ 0.1 to ≥ 19.8 kHz Measurement functions: + Automatic calculation of real-time Doppler parameters + Full range of basic measurements: distance, circumference, volume, area… + Measurements in vascular ultrasound Minimum connection parameters - Connectivity: DICOM 3.0 or better - Connectivity: HDMI or DVI-D output port, USB port.
Tu Son General Hospital
3
Patient monitoring machine (5 parameters)
2
Machine
a. General requirements: - 100% new equipment, never used - Year of manufacture: 2026 or later - Main machine quality standard: ISO 13485 - Operating environment: + Maximum temperature ≥ 30°C + Maximum humidity ≥ 70% b. Configuration - Main unit and built-in thermal printer: 1 set - ECG connecting cable, for 3 electrodes: 1 piece - SpO2 sensor connecting cable: 1 piece - Blood pressure cuff connecting cable for children and adults: 1 piece - Children's blood pressure cuff: 1 piece - Adult blood pressure cuff: 1 piece - Recording paper: 1 pack (consumable) - Adhesive electrodes: 30 pieces/bag (consumable) - Thermal printer head cleaning pen: 1 piece (consumable) - ECG cable: 1 piece - SpO2 sensor: 1 piece - Skin temperature sensor: 1 piece - Built-in rechargeable battery: 1 piece - Machine trolley: 1 piece - Power cord: 1 piece - English and Vietnamese user manual: 1 set. Technical specifications - Monitoring and alerting on key parameters in resuscitation: ECG, respiratory rate, SpO2/pulse, NIBP, temperature. - Color, liquid crystal, touch screen display - Features arrhythmia detection and recall * Measurement Range and Accuracy - ECG: - Number of electrodes: 3 electrodes - Input dynamic range: ≥ ± 5mV - Internal noise: ≤ 30µVp-p - Common-mode noise immunity: ≥ 95dB - Input resistance: ≥ 5MΩ (at 10Hz) - Input polarization current: ≤ 100 nA - Frequency response: diagnostic mode: 0.05 to 150Hz - Display sensitivity: 10mm/mV ±5% Selectable at least x 1/4, x 1/2, x1, x2, x4, or automatic - Recovery time after electrical shock: ≤ 10 seconds * Heart rate: - Measurement method: Moving average - Measurement range: ≥ 0 to ≤ 300 beats/minute ± 2 beats/minute - Accuracy: Not exceeding ± 2 beats/minute - Measurement update interval: every 3 seconds or upon alarm - High/low alarm limits can be set between 16 and 300 beats/minute * Arrhythmia analysis: - Number of channels: ≥ 1 - VPC counting rate: From 0 to ≥ 99 VPCs/minute - Number of arrhythmia recall files: ≥ 120 hours - Storage time for each segment: ≥ 10 seconds * ST elevation: - Number of channels: ≥ 1 - ST elevation measurement range: ±2.5mV * Respiratory rate: - Measurement method: Impedance - Measurement range: 0-≥150 beats/minute - Error: Not exceeding ± 2 beats/minute - Measurement impedance: Approximately 220Ω to 4kΩ - Internal noise: ≤ 0.2Ω - Sensitivity control: x1/4, x1/2, x1, x2, x4 - Frequency response: 3Hz ±10% - Shock resistance: 400 Ws/DC 5 kV ±10% - Shock recovery time: ≤ 10 seconds - Apnea monitoring: 5 to 40 seconds in 5-second increments * SpO2: - Update cycle: Every ≤ 3 seconds or when an alarm occurs - Scanning speed: 6.25, 12.5, 25, 50 mm/s - Sensitivity: x1/8, x1/4, x1/2, x1, x2, x4, x8, AUTO SpO2: - Method: Dual-wavelength absorption - Wavelength: 650/950 nm - Display range: 0 - 100% SpO2 - Accuracy: ± 3% SpO2 - High/low alarm limits can be set * Temperature: - Measurement range: Approximately 0°C - 45°C ± 0.2°C – 0.3°C - Deviation: Not exceeding ± 0.005°C/°C - Measurement update interval: Not exceeding 3 seconds or when an alarm is triggered - High/low alarm limits can be set * Non-invasive blood pressure (NIBP): - Measurement method: Oscillometric - Measurement range: 0 – ≥ 300 mmHg - Cuff inflation range: 0 - ≥ 300 mmHg - Accuracy: ± 3 mmHg - Measurement modes: Manual, continuous (≤ 15 minutes), cyclic, SIM - Automatic re-measurement available - Air leakage: ≤ 3 mmHg/min - Display items: Systolic (SYS), Diastolic (DIA) Average MAP, cuff pressure during NIBP measurement, pulse rate - Displays updated after each measurement - Audible alert when measurement is complete. - High/low alarm limits can be set - Recovery time after shock: ≤ 10 seconds * Pulse rate: - Measurement range: 30 to ≥ 300 beats/minute - Accuracy: ± ≤ 2 beats/minute or ±3% - Recovery time after shock: ≤ 10 seconds - High/low alarm limits can be set * Display: - Color, touch screen, TFT LCD or equivalent - Screen size ≥ 12 inches, resolution ≥ 800 x ≥ 600 pixels - Waveform display: Respiratory rate, SpO2 pulse waveform, ECG - Maximum number of waveforms: 6 - Numerical display: Heart rate, VPC, ST, respiratory rate, NIBP, SpO2, pulse rate, temperature - Synchronization with heart rate, respiratory rate and pulse can be marked * Alarm function - Alarm levels: At least emergency levels, warning Alarms and Reminders - Alarm Items: Vital Signs, Arrhythmia, Technical - Alarm Indicators: Indicator lights, alarm sounds, and message marking - Alarms can be paused for a period of time or turned off * Printer - Printing Method: Thermal matrix or equivalent - Number of Printing Channels: 3 channels - Recording Modes: Manual, cyclic, alarm - Paper Speed: Selectable 12.5, 25, and 50 mm/s.
Tu Son General Hospital
4
Patient monitoring machine (7 parameters)
3
Machine
a. General requirements: - 100% new equipment, never used - Year of manufacture: 2026 or later - Main unit quality standard: ISO 13485 - Main unit origin: From G7 or EU countries - Operating environment: + Maximum temperature ≥ 30°C + Maximum humidity ≥ 70% b. Requirements - Main unit and built-in thermal printer: 1 set - 3-wire ECG cable: 1 piece - Reusable non-invasive blood pressure (NIBP) cuff for adults: 1 piece - Reusable NIBP cuff for children: 1 piece - EtCO2 measurement kit: 1 set - IBP probe connector cable: 1 piece - Reusable SpO2 cable and probe for adults and children: 1 set - Reusable skin temperature probe: 1 piece - Machine trolley: 1 piece - Power cord: 1 piece - English-Vietnamese user manual: 1 set Technical Specifications: * Measurement Range and Accuracy: ECG: - Number of Electrodes: ≥ 3 (I, II, III) - Input Dynamic Range: ≥ ± 5mV - Internal Noise: ≤ 30µVp-p - Display Sensitivity: Selectable automatically or manually with values ​​of 10mm/mV x 1/4, x 1/2, x1, x2, x4, or automatic * Heart Rate - Measurement Method: Moving Average or equivalent. - Measurement range: ≥ 0 to ≤ 300 beats/minute ± 2 beats/minute - Measurement update interval: No more than 3 seconds or when an alarm is triggered * Arrhythmia analysis - Number of channels: 2 - Storage time for each segment: ≥ 8 seconds ST elevation - Number of channels: 1 - ST elevation measurement range: ±2.5mV * Respiratory rate - Measurement method: impedance or equivalent - Measurement range: ≥ 0 to 150 beats/minute - Accuracy: ± 2 beats/minute - Measurement impedance: Approximately 220Ω to 4kΩ - Display sensitivity: ≥ 5 values ​​10mm/ 1 Ω x 1/4 to x4 - Frequency response: Approximately 3Hz * SpO2 - Measurement range: 0 to 100% - Display range: ≥ 70 to 100% - Measurement update interval: None Over 3 seconds or when an alarm is triggered - Audible alarm with tone changing according to changes in SpO2 measurement value - Waveform sensitivity: Automatic or manual selection of x1/8, x1/4, x1/2, x1, x2, x4 and x8 values ​​* Temperature - Measurement range: 0ºC - 45ºC - Deviation: Not more than ± 0.005ºC/ºC - Measurement update interval: Not more than 3 seconds or when an alarm is triggered * Non-invasive blood pressure (NIBP) - Measurement method: Oscillometric or equivalent - Cuff pressure range: 0 to ≤ 300 mmHg - Maximum measurement time: Adults/children: ≤ 160 seconds, neonates: ≤ 80 seconds - Maximum pressure value: Adults/children ≥ 300mmHg, neonates: ≥ 150mmHg - Audible alarm * Invasive Blood Pressure (IPB) - Measurement range: 50 to 300 mmHg - Accuracy: ± 4% or ± 4mmHg - Auto-zero point equilibrium range: ± 200 mmHg - Auto-zero point equilibrium accuracy: ± 1mmHg - Noise level: Not exceeding ± 1mmHg - Measurement update: Not exceeding 3 seconds or when an alarm is triggered - Pulse measurement range: 30 to 300 beats/minute ± 2 beats/minute * EtCO2 - Startup time: ≤ 5 seconds - Measurement update: Not exceeding 3 seconds or when an alarm is triggered - Measurement range: 0 to ≤ 100 mmHg - Error: Not exceeding ± 10% - Response time: ≤ 160ms - Respiratory rate measurement range: 3-150 breaths/minute ± 10% * Display - Color touchscreen display, TFT LCD or equivalent type - Screen size ≥ 12 inches. - Displays 7 parameters simultaneously: ECG, respiratory rate, pulse, SpO2, IBP, CO2, and temperature. - Scanning speed: 6.25, 12.5, 25, and 50 mm/second. - Scanning time at 25 mm/second: 6.5 seconds. * Alarm function - Three alarm levels: Emergency, Reminder/Warning - Technical alarm items: Wire disconnection, interference, electrode disconnection, waveform detection, probe disconnection, blood pressure cuff/connector check, low battery… - Alarm type: Audible alarm, flashing/on light alarm, message/numerical data marking. - Alarm parameters: High and low alarm thresholds can be set. - Alarm can be deactivated within 1, 2, or 3 minutes. * Printer - Printing method: Thermal matrix or equivalent - Number of printing channels: 3 channels - Recording mode: Manual, cyclic, alarm - Paper speed: Selectable 12.5, 25 and 50 mm/s * Supply voltage - AC: 100 to 240VAC, 50-60Hz - DC: built-in battery, operating time ≥ 90 minutes
Tu Son General Hospital
5
Electrical syringe
10
Machine
a. General Requirements - 100% new, unused production equipment - Year of manufacture: 2025 or later, 100% new - Main machine manufacturer meets ISO 13485 quality standards - Main machine origin: From G7 or EU countries - Power supply: 220V/380V ± 10%, 50 Hz or suitable for Vietnam's power supply - Operating environment: + Maximum temperature ≥ 30°C + Maximum humidity ≥ 70% b. Configuration - Main machine with standard accessories: 1 set - Rechargeable battery: 1 set - Clamp/hanging lock: 1 set - Power cord: 1 - User manual in English and Vietnamese: 1 set c. Technical Specifications * General Features: - Color LCD or TFT screen or equivalent, size ≥ 3 inches - Indicator lights to show operating status, shutdown status, and warnings. - Two power sources: AC mains power and internal battery. * Technical Specifications: - Compatible syringe sizes: 5mL, 10mL, 20mL, 30mL, 50/60mL - Dosing Modes: + ml/h mode + µg/kg/min mode + mg/kg/h mode - Injection Rate: 0.1 to ≥ 1200mL/h + From 0.1 to ≥ 150 mL/h (using 5mL syringe) + From 0.1 to ≥ 300 mL/h (using 10, 20, 30 mL syringes) + From 0.1 to ≥ 1200 mL/h (using 50/60 mL syringe) - Step increment: ≤ 1 mL/h - Rate setting via rotary knob, button, or touchscreen - Injectable fluid volume: 00 to ≥ 9999 mL (step increment) ≤ 1 mL) - Rapid injection rate (Bolus) when pressing and holding the button: ≥ 100 mL/h (using a 5 mL/h syringe) + From 100.00 to ≥ 300.00 mL/h (using 10, 20, 30 mL syringes) + From 100.00 to ≥ 1200.00 mL/h (using a 50/60 mL syringe) - Rapid injection volume without pressing and holding the button (Bolus): 1 to ≥ 10 mL (setting increment ≤ 0.1) - Accuracy: ±3% with flow rate ≥ 1 mL/h - Infusion line blockage/occlusion alarm pressure: 50 to ≥ 120 kPa - Purge/air removal rate: Approximately ≥ 150 mL/h (using a syringe) 5 mL) + Approximately ≥ 300 mL/h (using a 10 mL syringe) + Approximately ≥ 400 mL/h (using a 20 mL syringe) + Approximately ≥ 500 mL/h (using a 30 mL syringe) + Approximately ≥ 1200 mL/h (using a 50/60 mL syringe) Alarms will sound in the following cases: Infusion line blockage, nearly empty fluid, incorrect syringe body assembly, low battery, infusion parameters not set, completion of preset fluid volume.
Tu Son General Hospital
6
Transmission machine
2
Female
a. General Requirements - 100% new, unused production equipment - Year of manufacture: 2026 or later - Main machine manufacturer meets ISO 13485 quality standards - Origin of main machine: From G7 or EU countries - Power supply: 220V/380V ± 10%, 50 Hz or suitable for Vietnam's power supply - Operating environment: + Maximum temperature ≥ 30°C + Maximum humidity ≥ 70% b. Configuration - Main machine and all standard accessories: 1 unit - Transfer terminal clamp: 1 unit - User manual in English and Vietnamese: 1 set c. Technical Specifications - Infusion pump capable of administering fluids and blood transfusions - Features a 4-inch or larger color LCD screen displaying parameters - DC power supply: Internal rechargeable battery provides continuous operation for 5 hours during power outages. - Includes an auxiliary battery for warning in case of battery failure or power outage. - Includes error and status indicator lights - Dose setting modes: ml/h; µg/kg/min; mg/kg/h - Infusion rate: + 0.1 – ≥ 1,200 ml/h + Step increment: 0.1 ml/h (within the infusion rate range of 0.1 – 100 ml/h) 1 ml/h (within the infusion rate range of 100 – 1,200 ml/h) - Volume limit: + 0.10 to 100 ml (step increment ≤ 0.1 ml) + 100 to 9,999 ml (step increment ≤ 1 ml) + Option to not set volume limit - Infusion time limit: + 1 minute to ≥ 99 hours 59 minutes (step increment 1 minute) + Option to not set infusion time limit - Dose setting range: + 0.01 to 10 (step increment 0.01) + 10 to 100 (step increment 0.1) + 100 to 999 (setting step 1) - Patient weight setting range: 0.1 – 300 kg (setting step 0.1 kg) - Set rapid infusion rate (Bolus) when pressing and holding the button: + 100 to ≥ 1,200 ml/h + Setting step ≤ 100 ml - Set rapid infusion volume without pressing and holding the button: + 0.01 to 10 mL (setting step ≤ 0.01 ml) + 10 to 100 mL (setting step ≤ 0.1 ml) + 100 to 999 mL (setting step ≤ 1 ml) - Set rapid infusion time without pressing and holding the button: 1 second to 60 minutes or more (setting step 1 second) - Display range for infused fluid volume: + 0 to ≥ 10 ml (setting step) ≤ 0.01 ml) + 10 to ≥ 100 ml (setting increment ≤ 0.1 ml) + 100 to ≥ 9,999 ml (setting increment ≤ 1 ml) - Accuracy: ± ≤ 5% - Pressure threshold for blockage detection: + Upper blockage detection pressure threshold: -100 to -30 kPa or more + Lower blockage detection pressure threshold: 30 to 120 kPa or more + ≥ 10 levels of lower blockage detection pressure threshold can be set - Fast infusion rate: ≥ 500 ml/hour - Alarms in the following cases: + Upper blockage + Lower blockage + Nearly empty infusion fluid + Air in the infusion line + Pump door open + Abnormal infusion rate + Empty infusion bottle + Low battery + Battery dead + Repeat alarm + START button prompt. + Infusion rate not set + Infusion volume not set + Infusion rate set exceeds the infusion volume limit + Preset volume completed - Safety functions: + Select line blockage alarm pressure at ≥ 10 levels + Select air infusion alarm sensitivity at 2 levels + Function to set near-empty infusion volume detection + Line automatically clamped when pump door opens + Set speed range limit A (Soft limit) + Set speed range limit B (Hard limit) + Keypad lock to prevent accidental key presses while the machine is operating + Bolus deceleration function - Other functions: + Display infusion line installation instructions on LCD screen + Display the type of infusion line being used on LCD screen. + Select and display infusion line type on LCD screen + Select infusion drop volume + Display infusion drop volume + Set infusion volume + Set infusion time + Audible alert in Purge/Bolus mode + Clear infused volume + Standby mode + Set standby time + Adjust alarm volume + Adjust keypad volume + Audible alert when STOP button is pressed + ≥ 5 levels of LCD screen brightness adjustment + Set and report device maintenance time + Set date and time + Save and view data: Approximately ≥ 10,000 events + AC mains power detection + Audible alert when AC mains power is detected + Keep injection line open + Clear infused fluid while the machine is still operating + Change speed while the machine is operating + Select dose setting mode while the machine is operating + Select alarm tone + Select 100 setting steps to shorten setting time + Fast infusion by pressing and holding Key + Fast infusion mode (no need to press and hold the key) + Audible alert when power is off. + Microdose symbol display selection function + Fast infusion by pressing and holding the key + Fast infusion mode (no need to press and hold the key) + Audible alert when power is off. + Microdose symbol display selection function
Tu Son General Hospital
7
Electrolytic
2
Machine
a. General requirements - 100% new, unused equipment - Year of manufacture: 2025 or later - Meets quality standards ISO 13485, MDR or equivalent - Origin: Group of G7 countries b. Configuration - Main machine with accessories: 01 set - 5 cm2 probe: 01 piece - Power cord: 01 piece - Patient cable + alligator clip: 02 pieces - Rubber electrode with belt: 01 set - User manual in English and Vietnamese: 01 set c. Technical specifications - Power source: Suitable for voltage in Vietnam - Power consumption: ≤60VA - Electrical protection level: I - Number of treatment channels: ≥2 channels - Screen: Color touch screen ≥7 inches, ≥1024×600 - Minimum current types: Galvanic current, Diadynamic current, High voltage current, Medium frequency current, Interferential current, Micro simulation current, Low frequency rectangular current - Preset program available - Galvanic current: ≥80 mA - Diadynamic current: ≥20 mA - High voltage current: ≥250 mA / 128V - Medium frequency current: ≥80 mA - Interference current: ≥100 mA - Micro simulation current: ≥2 mA - Low frequency rectangular wave current: ≥80 mA - Data storage Material: Internal memory, memory card or equivalent storage method - Capable of incorporating ultrasound function: - Application part: Type BF; ultrasound head - Therapy frequency: + 0.8 MHz + 2.4 MHz - Intensity level: 0.1 to 3 W/cm² within 0.1 W/cm²
Tu Son General Hospital
8
Electric machine
20
Female
a. General requirements: - 100% new, unused equipment - Year of manufacture: 2025 or later - Quality standards: ISO 13485 b. Configuration - Main machine: 01 piece - UM1 1.5V battery (big battery): 04 pieces - Acupuncture needle set: 01 set - Electrode wire: 06 pieces - User manual: 01 set c. Technical specifications: - Frequency and amplitude of output waves can be adjusted - There are ≥ 2 types of output waves: Add and describe or more - The machine uses DC batteries, does not use direct power. - There are ≥ 2 LED lights flashing according to the output frequency. - Frequency ≥ 2 output waveforms adjustable from ≥ 0.5 to 45 Hz - Pulse form: oscillating pulse, using both positive and negative parts. - Main pulse width, in ms: ≤ 0.4 ± 10%. - Output pulse amplitude, in Vpp: ≥ 0 to 140 ± 10%. - Pulse frequency, in Hz: ≥ 0.5 to 45 Hz. - There are ≥ 6 intensity adjustment knobs for ≥ 6 separate outputs. - Has a time setting: Set treatment time ≤ 90 minutes, error ≤ 3 minutes - Has sound warning (bell when time runs out). - Shell made of ABS plastic (base made of PP plastic).
Tu Son General Hospital
9
Automatic intraocular pressure monitor (non-contact)
1
Machine
a. General requirements - 100% new equipment, never used - Year of manufacture: 2025 or later - Main machine meets quality standards: ISO 13485 - Origin of main machine: Made in a country belonging to Group G7. b. Supply configuration - Main body and standard accessories: 01 piece - Dust cover: 01 piece - Integrated touch screen: 01 piece - Chin rest paper: 01 file - Lifting table with electric motor: 01 piece (China) - User manual in English and Vietnamese: 01 set c. Technical requirements - Has touch sensor. Helps quickly align between eye center and screen center. Has automatic alignment and automatic capture functions - Notifies the patient about the time of measurement - Has a function to calibrate eye pressure + Stable air pressure between measurements + Measurement delay time is ≤ 15 ms - Noise level is only ≤ 55 dB * Technical specifications: - Touch screen, size ≥ 5.7 inches - Measurement range: 0 to ≥ 60 mmHg - Movement range of the probe chin: ≥ 70 mm - Parts can be moved: + Up - down: ≥ 45 mm + Right - Left: ≥ 88 mm + Front - back: ≥ 40 mm - Communication port: RS - 232C - Print results: Integrated thermal printer
Tu Son General Hospital
10
Endoscopic ENT
1
System
a. General requirements: - 100% new equipment, never used - Year of manufacture: 2026 or later - Meets quality standard: ISO 13485 b. Configuration - The ENT endoscopy system includes: - Camera: 1 unit - Full HD image processor: 1 unit - Light source: 1 unit - Light guide cable: 1 unit - 0° endoscope (Size Ø 3mm x 110 mm): 1 unit - 0° endoscope (Size Ø4mm x 175 mm): 1 unit - 70° endoscope (Size Ø4mm x 175 mm): 1 unit - Machine trolley: 1 unit - Endoscope monitor: 1 unit - Power cord: 1 unit - Computer including Intel® Core™ i5 CPU, RAM: 8GB, Hard drive: 256GB SSD, Monitor ≥ 23 inch: 1 set - Color printer: 1 unit - User manual: 1 set Technical Specifications: * Image Processor - Power Supply: AC220V/50Hz - Video output with minimum ports: 2 HDMI, 1 DVI, 1 AV - Features include: White balance, Color correction, Zoom in/out, Pedal-operated shutter, Playback and replacement of captured images, Display: Real-time display, ≥ 3 split-screen modes (1, 2, 4 images, standard HD or more), Integrated physical control panel with waterproof and chemical-resistant membrane or equivalent. * Light Source - Power Supply: 220V/50Hz - Bulb type: LED or higher - Color temperature/Color rendering index: ≥ 5000 to 6000K/CRI 90 - Minimum of the following functions: - Brightness display - Brightness adjustment - Display of 80% brightness level when switched on - Age Lamp lifespan: ≥ 45,000 hours - Light plug standard: Storz/Wolf or equivalent * Endoscope camera - CMOS image sensor or higher - Image display ratio: 16:9 (1920 x 1080) - 5x4 (1280 x 1024) - Resolution: ≥ 1945 x 1109 ~ 2.16 Mega pixels - Camera has buttons: Zoom and shutter buttons * Light guide cable: - Length ≥ 2m - Outer diameter: ≤ 10 mm - 0° endoscope: Size: Ø 3mm x 110 mm - 0° endoscope: Size: Ø4mm x 175 mm - 70° endoscope: Size: Ø4mm x 175 mm * Machine trolley - Pressure die-cast aluminum column, anodized and powder coated - Wheels Vehicle diameter 100mm - Tool box with adjustable drawers - Camera and light cable suspension: Soft, scratch-resistant - Monitor suspension: Adjustable up/down, tilt, fold, and rotate - Endoscope holder: For storing the optics - Power supply system: ≥ 3 power outlets with covers, main On/Off switch * Endoscope monitor - Screen size: ≥ 27 inches - IPS technology or equivalent - Response time: ≥ 5 ms - Resolution ≥ 4K (3840 x 2160 pixels) - Signal input: HDMI
Tu Son General Hospital
11
Helicolytic treatment machine
1
Machine
a. General requirements - 100% new, unused production equipment - Year of manufacture: 2026 or later - Manufacturer meets ISO 13485 standards (for main machine) - Origin (for main machine): G7 - Equipment operating environment: + Maximum temperature: ≥ 30 degrees Celsius + Maximum humidity: ≥ 70% - Operating voltage: can be used with the voltage in Vietnam b. Configuration requirements: - Hand-held endodontic hand (body): 01 pc - Power supply + battery charger: 01 pc - Protective bag: 30 pcs - Mouth/cheek electrodes: 03 pcs - File clip: 01 pc - Connecting wire: 01 pc - User manual in English + Vietnamese: 01 set c. Technical specifications: Functions: - Apical positioning - Optimize sliding path - Optimize sliding path 2 - Optimize torque force - Optimize apical operation - Optimize apical operation 2 - Automatically turn on and off, automatically rotate when reaching the apex - Automatically stop at the apex, rotate slowly when reaching the apex - Gradually reduce torque, gradually reduce torque when reaching the apex - Reversal of torque Technical specifications - Endodontic hand: + Rotation speed: from 100 to ≥ 1000 rpm. + Torque: ≥ 4 Ncm - Rechargeable battery: + Machine uses Battery: Lithium-ion battery or equivalent + Estimated input voltage: DC 5V + Estimated input current: ≥ 2.A AC adapter + Input voltage: AC100 - 240 V + Estimated input frequency: ≥ 47 - ≤ 63 Hz + Estimated input current: ≥ 0.4A
Tu Son General Hospital
12
Hand -held spo2 meter
6
Machine
a. General requirements - 100% new, unused production equipment - Year of manufacture: 2025 or later Quality standards: ISO13485, CE or equivalent b. Configuration - Main body: 1 piece - Reusable SpO2 sensor for adults: 1 piece (for children, infants: optional) - Protective cover (optional): 1 piece - Lithium battery: 1 piece - Lithium charger: 1 piece - User manual in English + Vietnamese: 01 set c. Technical specifications: - TFT screen simultaneously displays SPO2 number, heart rate, perfusion index (PI), wave area - Suitable for both adults, children and infants - Audible and visual warning expressions can be adjusted according to the user's wishes - Manage patient information, allowing review of ≥ 600 most recent SPO2 and heart rate measurement results through tables and graphs displayed on the screen. - Display: Color LCD ≥ 2.3'' - SPO2 accuracy: Range: 70 to 100% ± 2 digits, 0% to 69%: unknown - Heart rate accuracy: Range: 25 to 250 ± 3 digits - Power supply: Lithium battery ≥ 3.7v or Alkaline battery: 3x1.5v AA - Operating time: Alkaline battery: ≥ 8 hours, Lithium battery: ≥ 10 hours - Charging time (for Lithium battery) ≤ 3 hours to get ≥ 90%, ≤ 6 hours to get 100%.
Tu Son General Hospital
13
Specialized medicine cabinet
3
Female
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 and FDA standards or equivalent b. Configuration: Specialized medicine cabinet: 01 c. Technical specifications: - Dimensions (LxWxH): (900x400x1700) ± 10mm - Cabinet divided into two compartments, with separate locks for each compartment: + Upper compartment ≥ 900mm, has 2 white glass doors, with hidden lock. Divided into 3 compartments with 2 inclined floors made of stainless steel plates; Above there are 2 AB compartments; has a separate key. + The lower compartment is ≥ 650mm high, has 1 stainless steel floor that can be removed or attached to the cabinet with mounting plates, 2 stainless steel doors, with locks. - Roof, roof, rear, floor covered with stainless steel panels. - 4 cabinet legs with rubber cushions. - Material: All metal parts are made of stainless steel 304 or higher + Cabinet frame, cabinet doors are made of stainless steel box 25x25, ≥ 0.6 mm thick + Surrounding panels, return, cabinet bottom, doors are made of stainless steel sheets ≥ 0.5 mm thick - White door glass is ≥ 5 mm thick
Tu Son General Hospital
14
Specialized injection vehicle
2
Female
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 and FDA standards or equivalent b. Configuration - Emergency equipment cart: 01 - Cart includes 5 drawers - Plastic box for needles to destroy: 02 - Plastic bin for medical waste: 02 - Shelf for defibrillator or monitor: 01 - CPR plate: 1 - File tray: 01 - Infusion pole: 01 Hook to hold oxygen tank: 01 - Vehicle has 04 wheels, 02 with wheels brake c. Technical specifications: - Dimensions (length x width x height): 840mm x 495mm x 965mm - The chassis is made of shaped aluminum bars. - The car's surface is made of monolithic molded plastic, the railing is made of stainless steel Ø 12.7, ≥ 70mm high. - The drawer is made of powder-coated steel, inside there are bars that divide the large tray into many small trays, with locks.
Tu Son General Hospital
15
Suction machine (low pressure)
2
Machine
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2026 or later - Main machine quality standards: ISO 13485 - Power supply: 220 – 240 VAC, 50/60Hz b. Configuration - Main machine with power cord: 01 piece - Suction tube length ≥ 120 cm: 2 pieces - Suction bottle ≥ 2 liters: 02 pieces - Bacterial filter: 02 pieces - Spare fuse: 02 pieces - 2-way conduit: 01 piece - English-Vietnamese usage documents: 01 set c. Technical specifications: - The machine is controlled by a microprocessor circuit - The machine has intermittent suction mode and continuous suction mode - You can set the suction time for the intermittent suction mode - The minimum suction time is ≥ 1 minute and the maximum ≤ 99 minutes - You can set the rest time for the intermittent suction mode - There is a pressure display - The suction bottle uses PC plastic that can be autoclaved (Autoclave) - The surface is made of stainless steel rusty - Safety device with anti-spill float assembly - Power consumption: ≤ 10W - Maximum negative pressure adjustment: 0 ~ ≤ 1500 mmH2O - Fluid tank capacity: ≥ 2000 ml x 02 pieces - Has a clock-type pressure gauge - Has a sterilization filter
Tu Son General Hospital
16
Suction machine (two-bottle pressure)
2
Machine
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Quality standards: ISO 13485 b. Configuration - Soft straw: 1 pc - Filter: 2 pcs - Power cord: 1 pc - Foot switch: 1 pc - Suction bottle: 02 bottles - User manual: 1 set 2. Technical specifications - Power source: AC220V±22V; 50Hz - Maximum vacuum pressure: ≥ 80kPa - Maximum pump suction pressure (suction speed): ≥ 20L/min - Operating noise: ≤ 60dB(A) - Suction tank: ≥ 2500ml with 2 tanks
Tu Son General Hospital
17
Patient bed
40
Female
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 and FDA quality standards or equivalent. b. Supply configuration: - Patient bed type 1 crank: 01 piece. - Bed mattress: 01 piece. - Hand crank: 01 piece. - Bed railing: 01 set. - Transmission pole: 01 piece. c. Technical specifications: - Dimensions (Length x Width x Height): + Length = 2,150mm (± 5%) (including headboard). + Width = 960mm (± 5%) (including barriers), 900 (± 5%) (without barriers). + Height = 510mm (± 5%) (not including cushion). - Highest back and head elevation angle: About 85° ± 5°. - Paint material: Powder coating. - Bed surface: The sections are made of ABS plastic, molded in one solid piece, making it easy to clean. - The inlaid surface has open oval holes divided into 2 parts: + Head back plate: 700mm long x 820mm wide x 40mm thick (±5mm). + Bed body panel: Length 1,175mm x width 820mm x thickness 40mm (±5mm). + Bed floor size: 820mm x 1,910 mm (±5mm). - Bed frame: Made of powder-coated box steel, box size ≥ 40mm x 80 mm, 1.5 mm thick. - Bed legs: Made of powder-coated box steel, box size ≥ 50mm x 50mm, 1.4mm thick. The two legs of the bed are connected together with a square steel box ≥ 30mm x 30 mm - Headboard: Made of ABS plastic, removable and easy to clean. - Headboard dimensions: 930mm long x 530mm high x 50mm thick (±5mm). - Crank: The bed has a crank with a threaded screw system on the outside covered with a plastic tube. - The crank can be folded at the end of the bed. - Fence: + Materials made of plastic, powder-coated steel and aluminum alloy. + The barrier is ≥ 1,460mm long, about 360mm high (± 5mm), can be folded down. + The barrier has 6 vertical stainless steel bars. - Cushion: + Dimensions: 1,910mm x 840mm (± 5mm). + Thickness: ≥ 70mm. + Cushion cover: Made of waterproof material. + Cushion: Made of PE.
Tu Son General Hospital
18
Bunker cabinet
40
Female
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 and FDA quality standards or equivalent. b. Supply configuration: - Plastic bedside cabinet: 01 piece. - Wheels: 04 pieces. c. Features and specifications: - Dimensions: 470mm x 470mm x 780mm (tolerance +/- 5%). - Materials: ABS plastic. - Table top for sitting and eating (top compartment, can be pulled in and out). - In the middle is a drawer for items. - Storage compartment with cabinet doors. - There are towel racks on both sides of the cabinet.
Tu Son General Hospital
19
Automatic hand sink
2
System
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 and CE standards or equivalent b. Configuration: - Surgical hand sink with 2 faucets: 01 piece - Standard installation accessories included: 01 set - Water pressure pump: 01 set - Filtration system: 2 coarse filters, 1 fine filter. - UV lamp: 01 set - Infrared sensor system combined with solenoid valve: 02 sets - Knee switch system: 02 sets - Water supply faucet: 02 sets - Automatic soap dispenser and dispenser: 01 set - Electrical control cabinet system: 01 set - English-Vietnamese user manual: 01 set c. Technical specifications: - Power source: 220V, 50 Hz ± 10% - Sterile hand washing sink is made of chemical-resistant monolithic composite used in medicine, fixed on the wall - The sink operates completely automatically and is adapted to environments with many interfering devices. - Water pressure pump with capacity ≥ 150W - Filter system: + Coarse filter ≥ 5 µm + Fine filter ≥ 1 µm. - Water sterilization system: + UV lamp has 3 layers + UV lamp capacity ≥ 29W. + Water can be sterilized up to ≥ 98%. + UV lamp life ≥ 9,000 hours. - Water heating system: Direct heating tank type, with temperature regulator to adjust the hand sanitizer temperature to suit the user from ambient temperature to 40° - High sensitivity infrared sensor system combined with solenoid valve - Knee switch system: One-touch shutdown type. - Water supply faucet: 304 stainless steel water supply faucet with automatic control. - Automatic soap dispenser and dispenser - Control cabinet system: All electrical equipment is installed in 01 electrical cabinet and placed inside the sink and suitable for the medical environment - Indicator light of voltage entering the sink: Yes - Sink: Volume 110 -120 liters - Approximate tank size (L x W x H): 1500x600x750 (mm) (tolerance ±5%)
Tu Son General Hospital
20
Minor surgery
1
Female
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 and CE standards or equivalent b. Configuration - Minor surgery table: 01 piece - Cushion: 01 piece c. Technical specifications: - Dimensions: (tolerance ± 5%) + Length 1950mm + Width 750mm + Height 750mm - Material is stainless steel - Includes 2 parts: Table top and table legs - Table top has raised head and back - Table top frame is 30x30 stainless steel ≥ 1mm thick; Table legs are made of stainless steel F32x1mm - Leg braces are made of 22 x 0.8mm - Table top and lifting head are made of stainless steel ≥ 0.8 mm - Lifting head can change the lifting angle from 0' - 60o - Table top and table legs are connected together by bolts and the support is ≥ 3mm - Foam cushion covered with faux leather fabric suitable for minor surgery tables
Tu Son General Hospital
21
Neonatal resuscitation bed (combined with jaundice light)
1
Female
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 standards b. Configuration: - Main machine with monitoring screen: 1 piece - Heating head integrated synchronously with main machine: 1 piece - Central skin temperature sensor, multiple use: 1 set - Peripheral skin temperature sensor, multiple use: 1 set - Mattress: 1 piece - Specialized cart with 4 wheels, designed synchronously with the main machine: 1 piece - User manual: 1 set c. Technical specifications: - Main machine system: + The device is a heating system for newborns + Control panel with LED display screen (with audio alarm) - Skin temperature measurement: Setting range: 32°C to 39°C - Jaundice lamp wavelength: within the range of 400nm - 500nm. - Power source: + Power consumption of heating element: ≤ 700 W + Voltage: 220V; 50Hz - Dimensions: + Bed size (length x width): About 550 - 700 mm × 550 - 700 mm + Bed tilt can be adjusted
Tu Son General Hospital
22
Newborn resuscitation bed
1
Female
a. General requirements: - 100% new, unused production equipment - Year of manufacture: 2025 or later - Meets ISO 13485 standards b. Configuration of Heated bed for newborns with standard accessories: 01 set including - Instrument tray: 01 - Skin temperature sensor: 01 - Infusion hanger: 01 - Cushion: 01 - User manual in English and Vietnamese: 01 set c. Technical specifications - Measurement: + Display resolution: ≥ 0.10C + Measurement resolution: ≥ 0.10C + Measurement parameters: Ambient temperature, probe (sensor) temperature - Measurement range + Heating measurement temperature: 0 - 40oC + Set temperature range: 32oC - 39oC - Proportional control based on set temperature and environmental temperature, ensuring safety by probe temperature - Dimensions: + Overall dimensions: 880 x 570 x 1800 mm (LxWxH) + Bed size: 880 x 565 x 1040 mm (LxWxH) + Crib size: Approx. 460 x 700 (mm) - Bed material: Transparent Meca - Height adjustment: From 1600: 1800 mm (Approx. 200 mm adjustment) - Crib height above the ground: ≥ 870 (mm) - Minimum heating rod life ≥ 2000 hours of use - Heating area: 800 x 600 mm (LxW) at a distance of 700 mm from the heating tray to the patient - Lighting system: Includes 6 1W warm white LEDs - Wheels: 4 rotating wheels, 65mm diameter (tolerance ± 5%) - Heating trough tilt: ± 40o - Weight: 25 to 30 kg - Infusion hanger: 150mm (tolerance ± 5%) - Working environment: + Measurement temperature range: From 0 to 40oC + Heating power level adjustment range: 0% to 100% - Noise: ≤ 20 dB (or ≤ 15 dBA - approved level adjusted to the same frequency to match the characteristics of the human ear) - Radiant power of heating head: ≥ 400W - Power source used: Nominal 220VAC - 50Hz, actual 185 to 240V AC, 47-63Hz - Optional accessories: Temperature sensor
Tu Son General Hospital
Approval decision information
Approval date
03/08/2026
Approval decision code
1345/BVĐKTS-VTTBYT
Approval decision file

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Purchasing assets from the 2026 public service development fund". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Purchasing assets from the 2026 public service development fund" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 5

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second