Quotation for 24-parameter hematology machine, urine testing machine

Find: 20:01 01/12/2025

Bid info

Project name/purchase estimate
Shopping for medical equipment in 2025
Bid name
Buy 24-parameter hematology testing machine, urine testing machine in 2025

Basic information of the request for quotation

Request for quotation code
RQ2500023119-02
Status
Posted
Name of request for quotation
Quotation for 24-parameter hematology machine, urine testing machine
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
Doan Ket Ward, Lai Chau Province, Phường Đoàn Kết, Province Lai Châu
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Ngô Thị Thúy Hà
Position
In charge of the Department of Planning, Finance and Information
Phone number
Address
Lai Chau Provincial Traditional Medicine Hospital, No. 316- Tran Hung Dao Street - Doan Ket Ward - Lai Chau Province

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 28/11/2025 16:16 To date 08/12/2025 17:00
Validity period of quotation
10 Day kể từ ngày 08/12/2025 17:00
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
24-parameter hematology analyzer
1
Female
I. General information: - 100% new machine - Year of manufacture 2024 and later - Quality standards applicable to the main machine manufacturer: ISO 13485 or equivalent - Power source: 110-240VAC, 50/60Hz - Working environment conditions: + Maximum temperature: 30 degrees Celsius + Maximum humidity: 80% II. Supply configuration: Main machine with automatic sample loader: 01 set Chemicals to run the machine: 03 sets Accompanying accessories set includes: + Chemical and waste wire set: 01 set + Power cord: 01 set + Sample tube tray: 01 set + Installation accessories set: 01 set + User manual in English and Vietnamese: 01 set Computer, printer (domestic purchase): 01 set + Connection software Lisa III. Technical specifications: Laser dispersion: + Multi-angle dispersion separation + Stem cell morphology signal Flow adjustment: + Chemical dye-free technology Minimum measured parameters include: + WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM#, MON#, NEU#, EOS#, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, P_LCC, RETIC%, RETIC_ABS, IRF + ≥7 body fluid parameters: WBC-BF, RBC-BF, MN %, MN#, PMN%, PMN#, TC- BF# + ≥14 research parameters: ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#, BLAST%, BLAST#, InR%, InR#, Eos-BF%, E os-BF#, Neu-BF%, Neu-BF# + ≥2 histograms for RBC and PLT + Two 3D stereoscopic images or equivalent Operating principle: + 5-part WBC: flow cytometry (FCM) analysis + 4-angle laser light scattering or equivalent + WBC analysis: optical and impedance measurement or equivalent + RBC/PLT analysis: impedance method or equivalent + HGB test: cyanide-free reagent colorimetry or equivalent + RETIC test: flow cytometry (FCM) analysis + laser light scattering or equivalent + Scatter method + chemical staining or equivalent
Lai Chau Provincial Traditional Medicine Hospital; Address: No. 316- Tran Hung Dao Street - Doan Ket Ward - Lai Chau Province
2
Urine testing machine
1
Female
I. General information: - 100% new machine - Year of manufacture 2024 and later - Quality standards applicable to the main machine manufacturer: ISO 13485 or equivalent II. Included configuration includes: + Main machine: 01 Unit + Integrated thermal printer: 01 Unit + Box of test strips: 01 Box + Printing paper: 01 Roll + Slider: 01 Unit + Power cord + Adapter: 01 Set 01 Unit + Lis connection software + User manual: 01 Set III. Features and technical specifications - Testing speed: ≥ 60 samples/hour - Minimum main measurement parameters include: Bilirubin, Glucose, Ketone, Leukocytes, nitrite, pH, protein, SG, Urobilinogen, Blood - Measurement ability: Albumin/Creatinine ratio (detects complications of kidney damage), detects hCG when using appropriate test strips - Screen: Touch - Storage: Results are stored on a personal computer or Network connection to the central computer via RS 232 port connection - Printer: Synchronous thermal printer integrated on the machine body - Measurement method: Photometric method or equivalent - Minimum wavelength includes: 470nm, 525nm, 565nm, 625nm, 660nm and 845nm - Display: Displays the time of reading results on the screen - Settings: Set up patient data, technicians and parameters other information through entering data directly on the screen - Select measurement parameters: Select measurement parameters depending on the type of test strip, measurement unit, mark abnormal results - Warning: Display errors on the screen - Autocheck feature or equivalent - Battery/battery: Can use batteries instead of mains power in case of mobile examination or power outage - Internal memory: ≥ 950 test results and ≥ 700 person IDs do a test
Lai Chau Provincial Traditional Medicine Hospital; Address: No. 316- Tran Hung Dao Street - Doan Ket Ward - Lai Chau Province
Other attachments

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Approval decision information
Approval date
28/11/2025
Code of decisions approving amendments
741/YCBG-BVYHCT
Approval decision file

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Related versions request quotation
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Quotation for 24-parameter hematology machine, urine testing machine". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Quotation for 24-parameter hematology machine, urine testing machine" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 10

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second