| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Repair and replacement of components for mammography systems. |
1 |
Package |
- Model: Pristina Senographe – Manufacturer: GE Spare parts, including: 1. 3000W inverter, used to power the X-ray tube of the mammography machine: 1 unit 2. Rectifier, used to power the mammography machine: 1 unit Service personnel performing the service, including: - Verify and confirm any errors or required parts before commencing the service. - Adjust and configure the machine system according to GE's operating standards after completing part replacement. - Inspect, verify, and hand over the equipment after the service is complete. |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
2 |
Repair and replacement of components for the GE OEC Elite C-arm system. |
1 |
Package |
Repair and replacement of components for the GE OEC Elite C-arm system Model: OEC Elite Manufacturer: GE Healthcare Replacement parts: Signal cable assembly, voltage <1000V, plastic or equivalent insulation, for mobile X-ray machines: 1 set Compatible with the existing OEC Elite C-arm system used at the Hospital. |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
3 |
Repair and replace components for continuous dialysis machines |
1 |
Package |
Repair and replacement of components for the continuous dialysis machine: Model: Prismaflex, Serial: PA12040. Components include: 1 blood pressure sensor for the continuous dialysis machine; 1 pre-filter pressure sensor for the continuous dialysis machine. All replacement parts must be compatible with the Prismaflex continuous dialysis machine. |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
4 |
Repair and replacement of Vitek MS bacterial identification machines |
1 |
Package |
Replacement parts include: - A set of replacement parts and components for maintenance, including: cooling fan, oil filter, desiccant, replacement oil, oil filter, rubber seals, and maintenance costs. |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
5 |
Repair and replacement of CO2 pump components used in laparoscopic abdominal surgery. |
1 |
Package |
Serial Number: 1100634416 Manufacturer: Richard Wolf Condition: Device failed the safety self-check program and is not suitable for use Error Code: 352-150-409 |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
6 |
Replacing the battery for the ECMO system |
1 |
Package |
Serial number: 90458526 Manufacturer: Maquet Rechargeable battery: 1 set |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
7 |
Repair and calibration of Fiboscan liver quantification ultrasound machine |
1 |
Package |
Ser: F63026. Model: Fibroscan. Manufacturer: Echosens. Country of Origin: France. Calibration (Calib) for M+ Probe: 1 time/per probe |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
8 |
Regular maintenance of the RO water system used for dialysis |
1 |
Package |
Regular maintenance of the RO water system used for hemodialysis and the filter cleaning machine, as per Decision 2482/QD-BYT. |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
9 |
Olympus gastroscopy instrument repair |
1 |
Package |
Repair and replacement of parts for the TF-160VR microscope:
Serial number: 2203218
Current status: Cable broken, unusable.
Parts list:
* Microscope body: 1
* Common cable: 1
* Corner protection mesh: 1
* Control cables: 4
* Corner protection housing: 1
* Elevator tool cable: 1
* Light guide fiber optic cable: 1
* Tool guide channel: 1
* Suction valve cylinder: 1 |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
10 |
Repairing Olympus gastroscopes |
1 |
Package |
Olympus GIF-XP190N Stomach Endoscopy Scope Repair: Serial Number: 2934446 Condition: Broken, unusable. Replacement parts include: Machine body: 1 unit Optical fiber cable: 1 unit Instrument channel cable: 1 unit Control cable: 4 units Corner bending protective net: 1 unit Corner bending protective shell: 1 unit |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
11 |
Repair and replacement of components for 3 high-temperature steam heating systems from Getinge |
1 |
Package |
Model: GSS67H Manufacturer: Getinge Replacement parts for steam sterilizers, including: *Serial: BAA097109 Positioner Valve: 1 piece Door Seal: 2 pieces HEPA Filter: 1 piece FV07 Piston Valve: 1 piece FV09 Piston Valve: 1 piece Steam Sterilizer Cleaning Kit: 1 set Air line kit: 1 set *Serial: BAA097110 HEPA Filter: 1 piece FV07 Piston Valve: 1 piece Steam Sterilizer Cleaning Kit: 1 set Air line kit: 1 set *Serial: BAA097111 Positioner Valve: 1 piece - All replacement parts must be compatible with Getinge's high-temperature steam sterilizers; |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
12 |
Repair and replacement of parts for Fujifilm portable X-ray machines. |
1 |
Package |
Model: FDR NANO
Manufacturer: Fujifilm
Services Offered: Repair and replacement of lithium batteries for portable X-ray systems; cleaning and calibration of equipment. |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
|||
13 |
Repairing and replacing components for fluorescent X-ray machines. |
1 |
Package |
Repair of the control screen for the fundus camera: Model: Eidon FA, Serial Number: 30021 - Replacement of the touch screen and recalibration of the control screen. |
Kien Giang General Hospital - No. 13 Nam Ky Khoi Nghia, Rach Gia ward, An Giang province |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Kiên Giang General Hospital:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Kiên Giang General Hospital:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.