1 |
Blood gas testing machine |
1 |
Machine |
BLOOD GAS ANALYZER: 1 UNIT – REQUIREMENTS FOR CONFIGURATION AND TECHNICAL SPECIFICATIONS I – General Requirements: – Origin: Group of major G7 economies – 100% new equipment – Manufacturing year from 2026 onwards – Compliance with quality management standards: ISO 13485 or equivalent (for main unit) – Power supply: 100-240 VAC, 50/60 Hz (for devices using electricity) – Operating environment conditions: + Maximum temperature ≥ 30°C + Maximum humidity ≥ 80% II – Configuration Requirements: – Main unit: 1 unit – Test reagents: < 100 samples per box – QC reagent kit: 1 sample – 1ml standard sampling syringe: 1 box – Includes a thermal printer – Barcode reader: 1 piece – Associated technical accessories: cables, thermal paper, CD-ROM – Technical documentation and user manual (English-Vietnamese): 1 set III – Technical Requirements Description: Blood gas/electrolyte/glucose & lactate/hematocrit analyzer. Uses biosensor technology (sensors) and intelligent quality management software (IQM) – a system for continuous, automatic, real-time quality assurance - PAK Cartridge, single-use, does not require refrigeration, contains all components for patient testing and does not require maintenance - IQM continuously monitors all tests while providing continuous error detection and correction, 24 hours/day, 7 days/week. Includes: + Continuous, real-time quality monitoring + Reduced error detection time compared to traditional QC + Automatic and continuous monitoring, finding, and correcting errors + Evaluation of functionality and proof of error correction + When the device exceeds the specified error limit, results will not be displayed - Easy operation, user-friendly touch screen, clear and concise menu simplifies selection, parameter adjustment, and result review. - Larger sample collection area with LED lighting for easy sampling. - Barcode scanner for quick data entry. - GEMweb connectivity: remote management software + View all operating status of networked devices in real time + Find and view patient and quality results on all networked machines from any connected PC + Request patient information from HIS/LIS + Connect to HIS/LIS via ASTM or HL-7 protocol - Can be connected to coagulation and CO-Oximetry modules - Single-use, refrigeration-free reagent box containing all necessary components for patient testing: process control solution, reference solution, sensor card, distribution valve, pump tube, sampling needle, and waste bag. Direct measurement parameters of blood gas (pH, pCO2, pO2), electrolytes (Na+, K+, Ca++), glucose & lactate, hematocrit Measurement limits and accuracy: Blood gas pH: ≤ 6.80 to ≥7.80, accuracy 0.01 PCO2: from ≤ 5 to ≥ 115 mmHg; accuracy 1 mmHg PO2: 0 to ≥ 760 mmHg; accuracy 1 mmHg Electrolytes Na+: from ≤ 100 to ≥ 200 mmol/L; accuracy 1 mmol/L K+: from ≤ 0.1 to ≥ 20.0 mmol/L; accuracy 0.1 mmol/L Ca++: ≤ 0.10 to ≥ 5.00 mmol/L; accuracy 0.01 mmol/L Metabolites Glucose from ≤ 5 to ≥ 500 mg/dL; accuracy 1 mg/dL Lactate from ≤ 0.2 to ≥ 15.0 mmol/L ; accuracy 0.1mmol/L Hematocrit from ≤ 15% to ≥ 65% ; accuracy 1% Calculated HCO3- from ≤ 3.0 to ≥ 60.0 mmol/L; accuracy 0.1 mmol/L HCO3std from ≤ 3.0 to ≥ 60.0 mmol/L; accuracy 0.1 mmol/L TCO2 from ≤ 3.0 to ≥ 60.0 mmol/L; accuracy 0.1 mmol/L BE(B) from ≤-30.0 to ≥30.0 mmol/L; accuracy 0.1 mmol/L BE(ecf) from ≤-30.0 to ≥30.0 mmol/; accuracy 0.1 mmol/L SO2C 0 to 100%; accuracy 1% Ca++(7.4) from ≤0.10 to ≥5.00 mmol/L; accuracy 0.01 mmol/L Input parameters: Temperature Range from ≤15.0 - ≥45.0oC Patient ID 16 characters Last name 16 characters First name 16 characters Operator password Full notes Sample 48 characters O2 0.0 - ≥99.0 L/min FIO2 ≤20% - ≥100% Other parameters: Type of sample: Whole blood, heparinized Volume of sample for one measurement 135l - ≤150 l At least 3 modes of operation: Arterial, Venous, Capillary Function interruption and recovery Time to measure a sample ≤ 85 seconds Packaging of reagents: 75/150/300/450/600 samples per box No need for refrigeration Technology measurement: Current measurement: pO2, Glucose, Lactate; Voltage measurement: pH, pCO2, Na+, K+, Ca++; Conductivity measurement: Hct Detection, correction and re-measurement: Automatic LCD color touch screen ≥ 10 inch Storage capacity ≥ 20.000 patient samples 3 port RS-232, 1 parallel printer port, 1 internet port, 4 USB ports Size, weight: H: 17.5 in, W: 13 in, D: 11.8 in, Wt: 31.2 lbs H: 44,5 cm, W: 33 cm, D: 30 cm, Wt: 14,2 kg. |
Cao Loc Regional Medical Center. Address: block 16, My Son street, Ky Lua ward, Lang Son province. |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Trung tâm y tế khu vực Cao Lộc:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Trung tâm y tế khu vực Cao Lộc:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.