Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Bilirubin Auto Total FS |
4 |
Box |
Chemicals for quantitative testing of total bilirubin in serum or plasma.
-Ingredients: R1: Phosphate buffer 50 mmol/L, NaCl 150 mmol/L. R1 ≥ 6x32.8mL ; R2: 2,4-Dichlorophenyl-diazonium salt 5 mmol/L, HCl 130 mmol/L, R2 ≥ 6x11.7mL
-Measuring range: up to 30 mg/dL (513 µmol/L).
-Detection limit: 0.03 mg/dL (0.5 µmol/L) |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3010 biochemical machine |
||
2 |
Bilirubin Auto Direct FS |
4 |
Box |
Diagnostic reagent for direct bilirubin quantitative test in serum or plasma.
- Ingredients: R1: EDTA-Na2 0.1 mmol/L, NaCl 150 mmol/L, Sulfamic acid 100 mmol/L, ; R2: 2,4-Dichloroaniline 0.5 mmol/L, HCl 900 mmol/L, EDTA-Na2 0.13 mmol/L
- R1 ≥ 16.2mL x6, R2 ≥ 6.6mL x6
- Detection limit: 0.01 mg/dL
- Measuring range: up to 10 mg/dL. |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3011 biochemical machine |
||
3 |
Cholesterol FS |
4 |
Box |
Chemicals for quantitative testing of cholesterol in serum or plasma. Box ≥ 59.4mL x4
-Ingredients: Good's buffer pH 6.7 50 mmol/L, Phenol 5 mmol/L, 4-Aminoantipyrine 0.3 mmol/L, Cholesterol esterase (CHE) ≥ 200 U/L, Cholesterol oxidase (CHO) ≥ 50 U/L, Peroxidase (POD) ≥ 3 kU/L
-Measuring range: up to 750 mg/dL (19.4 mmol/L).
-Detection limit: 2 mg/dL (0.05 mmol/L) |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3012 biochemical machine |
||
4 |
Creatinine FS |
8 |
Box |
Chemicals for quantitative testing of Creatinine in serum, plasma or urine according to the Jaffé method.
-Ingredients: R1: Sodium hydroxide 0.2 mol/L ; R2: Picric acid 20 mmol/L
- R1 ≥ 32.8mL x 6, R2 ≥ 11.7mL x 6
-Measuring range: up to 14 mg/dL.
-Detection limit: 0.1 mg/dL |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3013 biochemical machine |
||
5 |
Glucose Hexokinase FS |
12 |
Box |
Chemicals for quantitative testing of Glucose in serum, plasma or urine.
-Ingredients: R1: TRIS buffer pH 7.8 100 mmol/L, Mg2+ 4 mmol/L, ATP 2.1 mmol/L, NAD 2.1 mmol/L ; R2: Mg2+ 4 mmol/L, Hexokinase (HK) ≥7.5 kU/L, Glucose-6-phosphatedehydrogenase (G6P-DH) ≥7.5 kU/L
- R1 ≥ 57.8mL x 4, R2 ≥ 26.5mL x 3
- Measuring range: up to 500 mg/dL (30 mmol/L).
- Detection limit: 1 mg/dL (0.05 mmol/L) |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3014 biochemical machine |
||
6 |
Urea FS |
8 |
Box |
Chemicals for quantitative testing of Urea in serum, plasma or urine
-Ingredients: R1: TRIS pH 7.8 150 mmol/L, 2-Oxoglutarate 9 mmol/L, ADP 0.75 mmol/L, Urease ≥7 kU/L, GLDH (Glutamate dehydrogenase, bovine) ≥1 kU/L, R2: NADH 1.3 mmol/L.
- R1 ≥ 57.8mL x 4; R2 ≥ 26.5mL x 3
-Measuring range: up to 300 mg/dL (50 mmol/L).
-Detection limit: 2 mg/dL (0.35 mmol/L) |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3015 biochemical machine |
||
7 |
α-Amylase CC FS |
1 |
Box |
Chemicals for quantitative testing of α-Amylase in serum, plasma or urine.
-Ingredients: R1: Good's buffer pH 7.15 0.1 mol/L, NaCl 62.5 mmol/L, MgCl2 12.5 mmol/L, α-Glucosidase ≥2 kU/L, R2: Good's buffer pH 7.15 0.1 mol/L, EPS-G7 8.5 mmol/L.
- R1 ≥ 16.2 mL x 6; R2 ≥ 6.6mL x 6
-Measuring range: up to 1920 U/L.
-Detection limit: 0.6 U/L |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3016 biochemical machine |
||
8 |
ASAT (GOT) FS (IFCC mod.) |
7 |
Box |
Reagents for quantitative ASAT (GOT) assay in serum or plasma.
-Ingredients: R1: TRIS pH 7.65 110 mmol/L, L-Aspartate 320 mmol/L, MDH (malate dehydrogenase) ≥800 U/L, LDH (lactate dehydrogenase) ≥1200 U/L, R2: 2-Oxoglutarate 85 mmol/L, NADH 1 mmol/L.
- R1 ≥ 25mL x 6; R2 ≥ 9.2mL x 6
-Measuring range: up to 600 U/L.
-Detection limit: 1.2 U/L |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3017 biochemical machine |
||
9 |
ALAT (GPT) FS (IFCC mod.) |
7 |
Box |
Reagents for quantitative ALAT assay (GPT) in serum or plasma.
-Ingredients: R1: TRIS pH 7.15 140 mmol/L, L-Alanine 700 mmol/L, LDH (lactate dehydrogenase) ≥ 2300 U/L, R2: 2-Oxoglutarate 85 mmol/L, NADH 1 mmol/L. R1 ≥ 25mL x 6, R2 ≥ 9.2mL x 6
-Measuring range: up to 600 U/L.
-Detection limit: 0.6 U/L |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3018 biochemical machine |
||
10 |
Calcium P FS |
4 |
Box |
Chemicals for quantitative testing of Calcium in serum, plasma or urine. - Ingredients: R1: Malonic acid buffer pH 5.0 150 mmol/L, Phosphonazo III 150 µmol/L, R2: Malonic acid 150 mmol/L, Chelating agent < 150 mmol/L. - R1 ≥ 32.8 mL x 6, R2: ≥ 11.7 mL x 6 - Measuring range: up to 25 mg/dL (6.2 mmol/L). - Detection limit: 0.1 mg/dL (0.025 mmol/L) |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3019 biochemical machine |
||
11 |
Uric acid FS TIPS |
3 |
Box |
Chemicals for quantitative testing of Uric Acid in serum, plasma or urine.
- Ingredients: R1: Phosphate buffer pH 7.0 100 mmol/L, TOOS 1.25 mmol/L, Ascorbate oxidase ≥1.2 kU/L, R2: Phosphate buffer pH 7.0 100 mmol/L, 4-Aminoantipyrine 1.5 mmol/L, K4[Fe(CN)6] 50 µmol/L, Peroxidase (POD) ≥5 kU/L, Uricase ≥250 U/L. - R1 ≥ 32.8 mL x 6, R2: ≥ 11.7 mL x 6
- Measuring range: up to 20 mg/dL (1200 µmol/L).
- Detection limit: 0.24 mg/dL (14.5 µmol/L) |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3020 biochemical machine |
||
12 |
Triglycerides FS |
8 |
Box |
Chemicals for quantitative testing of Triglycerides in serum or plasma
- Ingredients: Good's buffer pH 7.2 50 mmol/L, 4-Chlorophenol 4 mmol/L, ATP 2 mmol/L, Mg2+ 15 mmol/L, Glycerokinase (GK) ≥0.4 kU/L, Peroxidase (POD) ≥2 kU/L, Lipoprotein lipase (LPL) ≥2 kU/L, 4-Aminoantipyrine 0.5 mmol/L, Glycerol-3-phosphate-oxidase (GPO) ≥0.5 kU/L.
- ≥ 31.7 mL x 4
- Measuring range: up to 1000 mg/dL (11.3 mmol/L).
- Detection limit: 2 mg/dL (0.023 mmol/L) |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3021 biochemical machine |
||
13 |
TruLab N |
6 |
Box |
Common level controls for a variety of routine tests.
Box ≥ 5mL x 6 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3022 biochemical machine |
||
14 |
TruLab P |
6 |
Box |
Pathological level control agent for many types of routine testing. Box ≥ 5mL x 6 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3023 biochemical machine |
||
15 |
Wash Solution No. 3 |
3 |
Box |
Washing water used for biochemical testing machines
Ingredients: Oxalic acid 6.2%. Box ≥ 500mL |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3024 biochemical machine |
||
16 |
Wash Solution No. 9 |
3 |
Box |
Washing water used for biochemical testing machines
Ingredients: Ethanol amine 8%. Box ≥ 500mL |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3025 biochemical machine |
||
17 |
WASH SOLUTION C-1 |
3 |
Box |
Washing water used for biochemical testing machines
Ingredients: Sodium hypochlorite 8.4%. Box ≥500mL |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3026 biochemical machine |
||
18 |
Halogen lamp |
6 |
Female |
The light bulb for the biochemical testing machine is suitable for the BX 3010 (Sysmex) machine. |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3027 biochemical machine |
||
19 |
TruCal U |
4 |
Box |
Test calibrator for quantifying 29 biochemical parameters. Box ≥ 3mL x 6 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3028 biochemical machine |
||
20 |
Alcohol |
4 |
Box |
Quantification of alcohol concentration in blood
R1: Tris-based buffer, sodium azide
R2: alcohol dehydrogenase (ADH), nicotinamide adenine dinucleotide, sodium azide. R1 ≥ 20mL x 4, R2 ≥ 15mL x 2 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3029 biochemical machine |
||
21 |
Alcohol Calibrator |
4 |
Box |
Calibration solution for Alcohol test. R1 ≥ 5mL x 1, R2 ≥ 5mL x 1 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3030 biochemical machine |
||
22 |
Alcohol Control Set |
4 |
Box |
Test solution for Alcohol test. Box ≥ 1mL x 2 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3031 biochemical machine |
||
23 |
HDL-c direct FS |
3 |
Box |
Chemicals for quantitative assay of HDL-c in serum or plasma.
- Ingredients: R1: Buffer pH 6.85 20 mmol/L, Peroxidase (POD) ≥ 2000 U/L, N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline sodium salt (H-DAOS) ≥ 0.7 mmol/L. R2: Buffer pH 8.15 20 mmol/L, Cholesterol esterase (CHE) ≥ 400 U/L, Cholesterol oxidase (CHO) ≥ 700 U/L, Peroxidase (POD) ≥ 15000 U/L, 4-Aminoantipyrine ≥ 1.5 mmol/L. - R1 ≥ 32.8mL x 6, R2 ≥ 11.7mL x 6
- Measuring range: up to 200 mg/dL
- Detection limit: 3 mg/dL. |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3032 biochemical machine |
||
24 |
TruCal Lipids |
2 |
Box |
Calibrator for serum HDL-C, LDL-C tests. Box ≥ 2mL x 3 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3033 biochemical machine |
||
25 |
TruLab L Level 1 |
2 |
Box |
Control substances for tests belonging to the Lipid set (level 1). Box ≥ 3mL x 3 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3034 biochemical machine |
||
26 |
TruLab L Level 2 |
2 |
Box |
Control substances for tests belonging to the Lipid set (level 2). Box ≥ 3mL x 3 |
Pleiku Medical Center |
Part 1: Procurement of chemicals and supplies for the BX3035 biochemical machine |
||
27 |
Quantitative test reagent Na, K, CL |
6 |
Box |
Chemicals used for electrolysis machine with 3 parameters Na, K, Cl
- Box of 1 bottle includes Standard A ≥ 650mL, Standard B ≥ 350mL
- Ingredient:
Buffer <0.1%
Inorganic salts <3.0 % |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3000 electrolysis machine |
||
28 |
Calibration substance quantitative test Na, K, CL, Ca, PH |
1 |
Jar |
Calibration solution for electrolyte components. Vial ≥ 30mL
- Ingredient:
Organic Buffer <0.1%
Inorganic salts <2.0 %
Preservative <0.05% |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3001 electrolysis machine |
||
29 |
Quantitative testing materials Na, K, CL, Ca, PH |
2 |
Jar |
Control solution for parameters Na +, K +, Cl-, Ca ++, pH; Vial ≥ 30mL
- Ingredient:
Organic Buffer <0.1%
Inorganic salts <2.0 %
Preservative <0.05% |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3002 electrolysis machine |
||
30 |
Washing solution for electrolyte analysts |
3 |
Jar |
Weekly cleaning solution. Vial ≥ 30mL
Ingredient:
Hypochlorite de sodium < 0.1 %
Surfactant < 1.0 %
Conservateurs < 0.05 % |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3003 electrolysis machine |
||
31 |
Reference electrode |
1 |
Female |
Reference electrode |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3004 electrolysis machine |
||
32 |
Chlorine electrode |
1 |
Female |
CL- electrode |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3005 electrolysis machine |
||
33 |
Potassium electrode |
1 |
Female |
K+ electrode |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3006 electrolysis machine |
||
34 |
Sodium electrode |
1 |
Female |
Na+ electrode+ |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3007 electrolysis machine |
||
35 |
Reagents for filling pH electrodes, Sodium, Chloride |
1 |
Jar |
Solution used with PH, Na, Cl electrodes; Vial ≥ 30mL
- Ingredient:
Buffer <0.5%
Inorganic salts <8.0 % |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3008 electrolysis machine |
||
36 |
Potassium electrode filling reagent for ISE 3000 electrolysis machine |
1 |
Jar |
Solution used with K electrode; Vial ≥ 30mL
- Ingredient:
Buffer <0.5%
Potassium salts <6.0 % |
Pleiku Medical Center |
Part 2: Procurement of chemicals and supplies for the ISE 3009 electrolysis machine |
||
37 |
INNOVIN |
12 |
Box |
Used to determine prothrombin time (PT)
Packaged in lyophilized powder form, containing recombinant human tissue factor, thromboplastin, calcium ions, neutralized heparin, buffers and stabilizers
Box ≥ 4ml x 10 |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-104 coagulation machine |
||
38 |
ACTIN FSL ACTIVATED PTT REAGENT |
12 |
Box |
Used to determine activated partial thromboplastin time (APTT)
Packaged in liquid form, the composition contains purified rabbit brain and soy phosphatides in 1 x 0.0001 ellagic acid, buffer and stabilizer.
Box ≥ 2ml x 10 |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-105 coagulation machine |
||
39 |
DADE THROMBIN RAGENT |
12 |
Box |
Used to quantify fibrinogen in plasma
Packaged in lyophilized powder form, the ingredient contains about 100 IU/ml of bovine-derived thrombin;
Box ≥ 1ml x 10 |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies used for the CA-106 coagulation machine |
||
40 |
DADE CI-TROL 1 |
20 |
Jar |
Control material for normal limits of coagulation tests.
Packaged in lyophilized powder form, derived from citrate anticoagulated human plasma
Vial ≥ 1ml |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-107 coagulation machine |
||
41 |
DADE CI-TROL 2 |
20 |
Jar |
Control material for coagulation tests in the mid to high range.
Packaged in lyophilized powder form, derived from citrate anticoagulated human plasma;
Vial ≥ 1ml |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-108 coagulation machine |
||
42 |
Calcium Chloride Solution |
3 |
Box |
Used as supplementary chemicals in blood coagulation tests such as APTT, factors VIII, IX, protein C, protein S tests...
Packaged in liquid form, 0.025 mol/L calcium chloride solution.
Box ≥ 15ml x 10 |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-109 coagulation machine |
||
43 |
Dade Owren's Veronal Buffer |
3 |
Box |
As a buffer solution in coagulation tests
Packed in liquid form, ingredients include sodium bardital 2.84 x 0.01M and sodium chloride 1.25 x 0.1M, pH 7.35 ± 0.1
Box ≥ 15ml x 10 |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-110 coagulation machine |
||
44 |
Standard Human Plasma |
5 |
Box |
Used to calibrate tests for PT, Fibrinogen, coagulation factors, inhibitors, Plasminogen. Ingredients are derived from human plasma.
Box ≥ 1ml x 10 |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-111 coagulation machine |
||
45 |
SUL-400A CUVETTE FL COMPLETE |
8.000 |
Female |
Cuvette used for CA-104 coagulation machine |
Pleiku Medical Center |
Part 3: Procurement of chemicals and supplies for the CA-112 coagulation machine |
||
46 |
FLUOROCELL WDF (WDF-800A) |
5 |
Box |
Uses: used to mark white blood cells in diluted and lysed blood samples to classify white blood cell components
Ingredients: Polymethine 0.002%; methanol 3.0%; Ethylene Glycol 96.9%;
Box ≥ 42ml x 2 |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies for the XN-550 hematology machine |
||
47 |
CELLCLEAN AUTO (CCA-500A) |
5 |
Box |
Uses: strong alkaline solution used to wash the system
Ingredients: Sodium Hypochloride 5.0%
Box ≥ 4mL x 20 |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies for the XN-551 hematology machine |
||
48 |
Sulfolyser |
7 |
Box |
Uses: used to measure hemoglobin concentration in blood
Ingredients: Sodium lauryl sulfate 1.7 g/L;
Box ≥ 500ml x 3 |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies used for XN-552 hematology machine |
||
49 |
Lysercell WDF (WDF-210A) |
8 |
Bin |
Uses: used to count the number of types of white blood cells: neutrophils, lymphocytes, eosinophils, monocytes
Ingredients: Organic quaternary ammonium salts 0.07%; Nonionic surfactant 0.17%
Container ≥ 5L |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies for the XN-553 hematology machine |
||
50 |
CELLPACK DCL (DCL-300A) |
45 |
Bin |
Uses: used to measure the number and size of red blood cells and platelets, also as a lysate to measure hemoglobin, and as a flow solution for flow cytometry
Ingredients: Sodium chloride 0.7%; Tris buffer 0.2%; EDTA-2K 0.02%;
Container ≥ 20L |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies for the XN-554 hematology machine |
||
51 |
CHECK L2 |
6 |
Jar |
Level 2 control material for CBC complete blood count
Composition: includes human red blood cells, human white blood cells, nuclear red blood cells and platelets;
Vial ≥ 3.0mL |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies for the XN-555 hematology machine |
||
52 |
CHECK L3 |
6 |
Jar |
Level 3 control material for CBC complete blood count
Composition: includes human red blood cells, human white blood cells, nuclear red blood cells and platelets;
Vial ≥ 3.0mL |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies for the XN-556 hematology machine |
||
53 |
CHECK L1 |
6 |
Jar |
Level 1 control material for CBC complete blood count
Composition: includes human red blood cells, human white blood cells, nuclear red blood cells and platelets;
Vial ≥ 3.0mL |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies used for XN-557 hematology machine |
||
54 |
XN Cal |
4 |
Jar |
Calibrators for hematology machines, including parameters WBC, RBC, HGB, HCT, PLT, RET
Vial ≥ 3.0mL |
Pleiku Medical Center |
Part 4: Procurement of chemicals and supplies used for XN-558 hematology machine |
||
55 |
Quantitative hematology test reagent GD-5 Diluent A |
25 |
Bin |
Chemical designed for use in diluting samples to prepare cell suspensions prior to blood cell analysis in Mispa HX50, HX58 automated hematology analyzers;
Ingredient:
- Sodium sulfate: 0.82%
- Sodium chloride: 0.50%
- Boric Acid: 0.10%
Container ≥ 20L |
Pleiku Medical Center |
Part 5: Procurement of chemicals and supplies for the MISPA HX58 hematology machine |
||
56 |
Quantitative hematology test reagent LH-5 Lysing Reagent A (used for 5-component hematology tester MISPA HX58) |
12 |
Box |
This reagent is used to destroy blood cells, dissolve hemoglobin and maintain the morphology of cells that need to be analyzed for cell counting or hemoglobin quantification in Mispa automatic hematology analyzers HX50, HX58 series;
Ingredient:
- Potassium chloride: 1%
- 2-phenoxyethanol: 1%
Box ≥ 500 mL |
Pleiku Medical Center |
Part 5: Procurement of chemicals and supplies for MISPA HX59 hematology machine |
||
57 |
Quantitative hematology test reagent LD-5 Lysing Reagent A (used for 5-component hematology tester MISPA HX58) |
18 |
Box |
This reagent is designed to be used to destroy blood cells, dissolve hemoglobin and maintain the morphology of the cells to be analyzed to count the number of differential cells in Mispa automatic hematology analyzers HX50, HX58 series;
Ingredient:
- Potassium hydrogen phthalate: 0.408%
- 2-phenoxyethanol: 0.13%
- Sodium Hydroxide: 0.095%
Box ≥ 1L |
Pleiku Medical Center |
Part 5: Procurement of chemicals and supplies for MISPA HX60 hematology machine |
||
58 |
Quantitative hematology test reagent DD-5 Fluorescent Dye A (used for 5-component hematology tester MISPA HX58) |
12 |
Box |
This reagent is used to stain blood cells to observe their shape and structure so that Mispa HX50 and HX58 series automatic hematology analyzers can perform various blood cell counts;
Ingredient:
- Methanol: 95.89%
- Ethane-1,2-diol: 4.11%
- Dye: 0.0027%
Box ≥ 42 mL |
Pleiku Medical Center |
Part 5: Procurement of chemicals and supplies for MISPA HX61 hematology machine |
||
59 |
Washed IVD used in CC-5 Cell Clean A hematology test |
12 |
Box |
This reagent is used for regular cleaning of Mispa HX50, HX58 series automatic hematology analyzers;
Ingredient:
- Sodium hypochlorite: 99.98%
Box ≥2 mL x 6 |
Pleiku Medical Center |
Part 5: Procurement of chemicals and supplies for MISPA HX62 hematology machine |
||
60 |
Quantitative hematology control materials HX Series Haematology Control (Tri Level) |
6 |
Box |
The product is used for quality control of Mispa HX series automatic hematology analyzers;
Kit components:
- Hematology Control Low (Level 1) - quantity 1
- Hematology Control Normal (Level 2) - quantity 1
- Hematology Control High (level 3) - quantity 1
Box ≥ 4.5 mL x3 |
Pleiku Medical Center |
Part 5: Procurement of chemicals and supplies for MISPA HX63 hematology machine |
||
61 |
HX Series Calibrator Hematology Quantitative Assay Calibrator |
4 |
Box |
Sản phẩm được sử dụng để hiệu chuẩn Mispa HX50, HX58, HX80, HX85, HX88 và các máy phân tích huyết học tương tự khác;
Ingredients: whole blood
Box ≥ 3.5 mL |
Pleiku Medical Center |
Part 5: Procurement of chemicals and supplies for MISPA HX64 hematology machine |
||
62 |
ALT/GPT |
10 |
Box |
Alanine aminotransferase (ALT) quantitative reagent
Ingredients and concentration:
R1 TRIS buffer 150 mmol/L; R1 L-Alanine 750 mmol/L; R1 LDH ≥1200 U/L; R2 NADH 0.4 mmol/L; R2 α-oxoglutarate 90 mmol/L;
Linear range: Serum/Plasma 4-1000 U/L: 0.07-16.67 µkat/L
R1 ≥ 35mL x4; R2 ≥ 18mL x2 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
63 |
AST/GOT |
10 |
Box |
Aspartate aminotransferase (AST) quantitative reagent;
Ingredients and concentration:
R1 TRIS buffer 100 mmol/L; R1 L-aspartate 300 mmol/L; R1 LDH ≥900 U/L; R2 MDH ≥600 U/L; R2 NADH 0.4 mmol/L; R1 ≥35mL x4 + R2 ≥ 18mL x2
Linear range: Serum/Plasma 4-800 U/L: 0.07-13.33 µkat/L
R1 ≥35mL x4; R2 ≥ 18mL x2 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
64 |
Bil-D(DSA) |
4 |
Box |
Diagnostic reagent for direct bilirubin quantitative test in serum or plasma;
Ingredients and concentration:
R1 Tartrate buffer 100 mmol/L; R2 Phosphate buffer 10 mmol/L; R2 Vanadiate 4 mmol/L
Linear range: Serum/Plasma 0.06-25.3 mg/dL: 1-430 umol/L
R1 ≥ 20mL x4; R2 ≥ 20mL x1 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
65 |
Bil-T(DSA) |
4 |
Box |
Chemicals for quantitative testing of total bilirubin in serum or plasma.
Ingredients and concentration:
R1 Citrate buffer 100 mmol/L; R1 Surfactant <1%; R2 Phosphate buffer 10 mmol/L; R2 Vanadiate 4 mmol/L
Linear range: Serum/Plasma 0.12-40.2 mg/dL: 2-684 umol/L
R1: ≥4×20mL x4; R2: ≥20mLx1. |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
66 |
Shift |
5 |
Box |
Calcium testing chemicals
Ingredients and concentration:
R Phosphate buffer 50 mmol/L; R 8-Hydroxyquinoline-5- sulfonic acid 5 mmol/L; R Arsenazo Ⅲ 0.12 mmol/L
Linear range: Serum/Plasma/Urine 0.1-3.75 mmol/L: 0.1-3.75 mmol/L
Box ≥ 40mLx4 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
67 |
CREA(SOX) |
20 |
Box |
Creatinine quantitative reagent.
Ingredients and concentration:
R1 Sodium hydroxide 0.38 mol/L; R2 Picric acid 15 mmol/L.
Linear range: Serum/Plasma/Urine 9–2420 µmol/L
R1 ≥ 27mL x2; R2 ≥ 18mL x1 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
68 |
GGT |
10 |
Box |
γ‑glutamyltransferase (GGT) quantitative reagent
Ingredient:
R1 TRIS buffer 100 mmol/L, Glycyl-glycine 150 mmol/L
R2 L-γ-glutamyl-3-carboxy-4-nitroanilide 20 mmol/L
R1 ≥ 35mL x4; R2 ≥ 18mL x2 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
69 |
Glu(HK) |
40 |
Box |
Glucose quantitative reagent
Ingredients and concentration:
R1: Tris buffer 15 mmol/L
NAD+ 6 mmol/L
ATP 1.43 mmol/L
Sodium azide 0.09%
R2: Tris buffer 25 mmol/L
Magnesium acetate tetrahydrate 9.98 mmol/L
Hexokinase >6 KU/L
Glucose-6-phosphate dehydrogenase >10 KU/L
Sodium azide 0.09%
R1 ≥ 40mL x4 ; R2 ≥ 20mL x2 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
70 |
HDL-C |
3 |
Box |
Reagent for quantifying HDL‑cholesterol concentration
Ingredients and concentration:
R1: Good’s buffer 100 mmol/L
Cholesterol esterase 600 U/L
Cholesterol oxidase 380 U/L
Catalase 600 KU/L
HDAOS 0.42 mmol/L
R2: Good’s buffer 100 mmol/L
4-aminoantipyrine 1.0 mmol/L
Peroxidase >2.8 U/mL
Surfactant<2%
Linear range: Serum 0.05-6 mmol/L
R1 ≥ 40mL x1; R2 ≥ 14mL x1 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
71 |
Lipids Calibrator |
6 |
Box |
Calibration of tests: Apolipoprotein A1 (ApoA1), Apolipoprotein B (ApoB), HDL- Cholesterol (HDL-C), LDL- Cholesterol (LDL-C)
Box ≥ 1 mL x 5 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
72 |
UA |
3 |
Box |
Uric Acid quantitative reagent
Ingredients and concentration:
R1 Phosphate buffer 70 mmol/L; R1 Peroxidase 5000 U/L; R1 Ascorbate oxidase 3000 U/L; R1 TOOS 0.72 mmol/L; R2 Phosphate buffer 70 mmol/L; R2 Peroxidase 10000 U/L; R2 4-Aminoantipyrine 1.7 mmol/L; R2 Uricase 750 U/L
Linear range: Serum/Plasma/Urine 20.8-1500 µmol/L
R1 ≥ 40mL x 4; R2 ≥ 20mL x 2 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
73 |
Urea |
10 |
Box |
Urea quantitative reagent
Ingredients and concentration:
R1 Tris buffer 120 mmol/L; R1 ADP 750 mmol/L; R1 Urease ≥40 KU/L; R1 GLDH ≥0.4 KU/L; R2 NADH 1.2 mmol/L; R2 α-Oxoglutarate 25 mmol/L
Linear range: Serum/Plasma/Urine 1-40 mmol/L
R1 ≥ 35mL x 4; R2 ≥ 18mL x 2 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
74 |
α-AMY |
3 |
Box |
Amylase test chemicals
Ingredients and concentration:
R1 TRIS buffer 50 mmol/L; R1 Magnesium sulphate 10 mmol/L; R1 a-Glucosidase 4500 U/L; R2 TRIS buffer 50 mmol/L; R2 E-pNP-G7 5.5 mmol/L R1 ≥ 38mL; R2 ≥ 10mL
Linear range: Serum / Plasma / Urine 5-1500 U/L: 0.08-25 µkat/L
R1 ≥ 38mL; R2 ≥ 10mL |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
75 |
Multi Sera Calibrator |
6 |
Box |
Quantitative calibration chemicals for routine chemical analytes.
Box ≥ 3mL x 10 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
76 |
Clinchem Multi Control (Level 1) |
6 |
Box |
General control chemicals for routine parameters level 1
Box ≥5 mL x6 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
77 |
Clinchem Multi Control (Level 2) |
6 |
Box |
Chemicals for general control of routine parameters level 2
Box ≥5 mL x6 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
78 |
Ref electrode,direct,international |
1 |
Female |
The main components of the reference electrode are the sensitive membrane in contact with the sample flow path, the reference solution in the carrier, and the reference electrode inside the Ag/AgCl |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
79 |
K electrode, direct, international |
1 |
Female |
The K+ electrode is a sensitive membrane in contact with the sample flow channel and reference solution and the Ag/AgCl reference electrode in the carrier. The composition of the K+ electrode sensitive membrane is PVC. |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
80 |
Na electrode ,direct ,international |
1 |
Female |
The Na+ electrode is a sensitive membrane in contact with the sample flow channel and reference solution and the Ag/AgCl reference electrode in the carrier. The composition of the Na+ electrode sensitive membrane is PVC. |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
81 |
Cl electrode,direct ,international |
1 |
Female |
The Cl- electrode is a sensitive membrane in contact with the sample flow channel and reference solution and the Ag/AgCl reference electrode in the carrier. The composition of the Cl electrode sensitive membrane is PVC. |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
82 |
ISE Reagent Pack |
10 |
Box |
Solution for the determination of sodium, potassium and chloride in serum, plasma or urine using ISE ion selective electrodes, Ingredients: Calibrant A , Calibrant B , Waste Storage;
Box includes Buffer A ≥ 460ml and Buffer B ≥ 360ml |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
83 |
Na Cleaning Solution |
6 |
Box |
Clean the response system during detection.
Main ingredient: ammonium acid fluoride.
Box ≥ 15mL |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
84 |
Probe Cleanser (Detergent C) |
12 |
Box |
Sample needle cleaning solution, when running electrolysis.
Box ≥ 15mL |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
85 |
ISE Cleaning Solution |
6 |
Box |
Purify the reaction system during detection to facilitate in vitro detection of the substance under test. Main ingredients: Methylene blue, surfactant.
Box ≥ 50 mL |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
86 |
Urine Diluent |
5 |
Box |
Urine sample dilution solution for electrolysis.
Box ≥ 50 mL |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
||
87 |
CD80 Detergent |
12 |
Box |
Wash sample needles, reagent needles, stirrers and measuring cuvettes for biochemical testing machines. Ingredients: 2% potassium hydroxide, EDTA disodium salt dihydrate, phosphate free.
Box ≥ 2Lx 6 |
Pleiku Medical Center |
Part 6: Procurement of chemicals and supplies for Mindray BS-600M biochemical machine |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
- RQ2500018401-01 - Change:Request for quotation code, Quotation acceptance time (View changes)
- RQ2500018401-00 Posted for the first time (View changes)
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor TRUNG TÂM Y TẾ PLEIKU:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding TRUNG TÂM Y TẾ PLEIKU:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.