Supply chemicals for testing

Find: 10:21 10/09/2025

Bid info

Project name/purchase estimate
Buy chemicals for testing for hematology and blood clotting analysis
Bid name
Buy chemicals for testing for hematology and blood clotting analysis

Basic information of the request for quotation

Request for quotation code
RQ2500011814-00
Status
Posted
Name of request for quotation
Supply chemicals for testing
Address of the unit requesting a quote
Address of the unit requesting a quote (After merge)
No. 15 Luu Cong Hoa Street, Tan My Village, Xã Hậu Lộc, Province Thanh Hoá
Categorize quotation requests
Bidding package for purchasing chemicals, testing supplies, and medical equipment

Contact information of the person responsible for receiving the quotation

Full Name
Hoàng Sỹ Quân
Position
Dean
Phone number
Address
Faculty of Pharmacy - VT, TBYT - Hau Loc General Hospital

How to receive quotation

Form of receiving quotation
Offline
Location of request for quotation
http://muasamcong.mpi.gov.vn
Quotation acceptance time
Since 10/09/2025 10:19 To date 24/09/2025 17:00
Validity period of quotation
90 Day kể từ ngày 24/09/2025 17:00
Request for quotation
 

Content of request for quotation

Filter data

data/page
No List of product/services Quantity Unit Description Location Specification Note Feature
1
IVD is a diluted solution for hematological testing
200.000
ML
Ingredient: Sodium chloride <1.5% Buffer solution <1.0% preservatives <0.5% stabilizer <0.5% Properties: Melting point: -2 ° C boiling point: 102 ° C Density at 20 ° C: 1.0 g/cm3 Vapor pressure at 20 ° C: 23 HPA PH: 7.0 Analysis results: Thermal conductivity (at 25 ° C): 19.2 (16.5 - 21.5) MS/cm pH (at 25 ° C): 7.2 (6.9 - 7.4) OSM: 310 - 350 MOS/kg PLT ≤ 5 (PLT = 2) Efficiency: R (WBC) ≥ 0.95; R (HGB) ≥ 0.95; R (RBC) ≥ 0.95; R (MCV) ≥ 0.90; R (PLT) ≥ 0.90 Meet ISO 13485: 2016
Hau Loc General Hospital
2
IVD awards for hematological analysts
8.000
ML
Ingredient: The substrate <3.5% Buffer solution <1.0% preservatives <0.5% stabilizer <0.5% Properties: Melting point: -2 ° C boiling point: 102 ° C Density at 20 ° C: 1.0 g/cm3 Vapor pressure at 20 ° C: 23 HPA PH: 7.5 Organic solvent: <1% of analysis results: Thermal conductivity (at 25 ° C): 3.5 (3.0 - 5.0) ms/cm pH (at 25 ° C): 7.5 (6.3 - 8.2) WBC ≤ 0.05 Efficiency: R (WBC) ≥ 0.95; R (HGB) ≥ 0.95; R (Lym) ≥ 0.90; R (Gran) ≥ 0.90 Meet ISO 13485: 2016
Hau Loc General Hospital
3
IVD is a washing solution for hematological analysts (normal washing solution, cleaning blood sediment, daily/periodic use.)
5.000
ML
Ingredient: Deterges <1.0% Buffer solution <1.0% preservatives <0.5%. Stable <0.5% Properties: Melting point: -2 ° C boiling point: 102 ° C The density is at 20 ° C: 1.0 g/cm3 of the vapor pressure at 20 ° C: 23 hpa pH: 9.0 Organic solvent: 0% of the analysis results: Thermal conductivity (at 25 ° C): 14.6 (13.0 - 17.0) MS/cm pH (at 25 ° C): 9.0 (7.0 - 9.0) PLT ≤ 5 (PLT = 1) Meet ISO 13485: 2016
Hau Loc General Hospital
4
IVD is a washing solution for hematological analysts (washing solution containing hypochlorite components
3.000
ML
Ingredient: Deterges <1.0% sodium hypochlorite <1.0% sodium hydroxide <1.0% stabilizer <0.4% Properties: Melting point: -2 ° C boiling point: 102 ° C The density is at 20 ° C: 1.0 g/cm3 of the vapor pressure at 20 ° C: 23 HPA PH: 12 Organic solvent: 0% Ingredients: Sodium hypochlorite: 0.1 - 1.0% (m/m) Sodium hydroxide: 0.5 - 2.0% (m/m) analytical results: pH (at 25 ° C): 12.9 (11.0 - 13.5) PLT ≤ 5 (PLT = 1) Meet ISO 13485: 2016
Hau Loc General Hospital
5
IVD is a washing solution for hematological analysts (Washing solution contains hypochlorite composition
100
ML
Ingredient: Deterges <1.0% sodium hypochlorite <5.0% sodium hydroxide <0.5% stabilizer <0.5% Properties: Melting point: -2 ° C boiling point: 102 ° C Density at 20 ° C: 1.07 g/cm3 Vapor pressure at 20 ° C: 23 HPA PH: 13 Organic solvent: 0% Ingredients: Sodium hypochlorite: 1.0 - 5.0% (m/m) Sodium hydroxide: 0.3 - 2.0% (m/m) Analysis results: pH (at 25 ° C): 13.1 (11.5 - 13.5) Sodium hypoclorite content ≥ 4.5 % meet ISO 13485: 2016.
Hau Loc General Hospital
6
Control materials for hematological analyst 3 parameters
18
ML
2x3x3 ml Ingredient: Potassium hydroxide <1% (m/m) .Sodium azide <0.1% (m/m) cicloheximide ≤0.05% (m/m) meets ISO 13485: 2016
Hau Loc General Hospital
7
Chemicals for cleaning and infection on automatic coagulation system
240
ML
Chemicals are used to clean and infected on automatic coagulation system. The minimum component contains sodium hypoclorite solution. Certificate of CE, ISO quality (13485)
Hau Loc General Hospital
8
The standard substance used for tests on blood clotting analyzes
10
ML
Chemicals used for calibration for blood clotting tests such as pt, fibrinogen, elements, elements Von Willebrand, Antithrombin, Plasminogen, Plasmin Inhitor, Protein S, Protein C. Freezing. Minimum composition: Contains human plasma. Stable time: At least 24 hours at 2-8 degrees Celsius with PT, APTT, Fibrinogen, TT, Antithrombin, Plasminogen, Plasmin Inhitor, Protein C and S protein, minimum from 8 hours at 2-8 degrees Celsius with tests for CE, FDA, ISO quality certification factor (13485)
Hau Loc General Hospital
9
Chemical solution used to clean on automatic blood clotting system
2.000
ML
Chemicals are used to clean on automatic coagulation system. The minimum component contains 100 mmol chlohydric acid. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
10
Chemicals used to dilute on blood clotting analysis system
200
ML
Chemicals used to dilute the standard test on blood clotting testing machines. Liquid form. The minimum component contains sodium chloride and sodium Azide. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
11
Chemicals used for quantitative fibrinogen testing, according to Clauss method on blood clotting analysts
80
ML
Chemicals used for quantitative fibrinogen-clauss. Dry powder. Minimum component containing: Thrombin originated from cow. Linear linearity is at least 35 mg/dL and up to 1000 mg/dL. Stability used after reconstitution (or open lid) minimum at least 3 days of temperature 2-8 degrees C, minimum from 3 days temperatures 15 degrees Celsius on the machine. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
12
Extraordinary verification substances for tests on blood clotting analyzes
10
ML
Chemicals used to check for blood clotting tests such as PT, APTT, hepatoComplex in high abnormal measurement range. Dry powder. The minimum component contains human plasma. Stable time: minimum from 24 hours with PT, APTT test or a minimum stable time from 8 hours with HepatoComlex test. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
13
Low abnormal verification substances used for tests on blood clotting analyzes
20
ML
Chemicals used to check for blood clotting tests such as PT, APTT, TT, Fibrinogen, Antithrombin, S protein, protein C, hepatoCompple in low abnormal measurement range. Dry powder. The minimum component contains human plasma. Stable time: minimum 24 hours for PT, APTT, Fibrinogen test, TT or at least 8 hours with HepatOCOCEX test. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
14
The normal tester is used for tests on blood clotting analysts
20
ML
Chemicals used to check the blood clotting tests such as pt, APTT, TT, Fibrinogen, all kinds of elements, elements Von Willebrand, Antithrombin, Plasminogen, Plasmin Inhitor, Protein S, Protein C, HepatoComplex in normal measurement bands. Dry powder. The minimum component contains human plasma. At least 24 hours of stability with PT, APTT, Fibrinogen test, TT or at least 8 hours with HepatoComplex test. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
15
Chemicals measuring time pt time for blood clotting analyzer
400
ML
Chemicals to determine prothrombin (PT) time and quantify fibrinogen in human plasma on automatic blood clotting testing machine. Chemicals with average ISI sensitivity reaches 1.00 and sensitivity to heparin ≤ 1.0 U/ml. Dry powder and preservatives and cushions. The minimum component contains: Factors of recombinant tissue, synthetic phospholipid, calcium chloride. Stability used after reconstitution (or open the lid) minimum 10 days at a temperature of 2-8 degrees Celsius and at least 4 days at 15 degrees Celsius on the machine. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
16
Chemicals measuring time APTT for blood clotting analysts
500
ML
Chemicals used for APTT time testing with calcium chloride. Liquid form. The minimum component contains silica glue, synthetic phospholipid, cushion and preservatives. Stability used after reconstitution (or open the lid) at least 30 days of temperature 2-8 degrees Celsius, at least 10 days of temperature 15 degrees Celsius on the machine. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
17
Thrombin Time Time Testing (TT) for blood clotting analysts
119
ML
Chemicals used to test the time thrombintime (TT) in a plasma sample. Dry and liquid powder. The minimum ingredient contains thrombin derived from cows, calcium chloride, cushion. Stability used after reconstitution (or open lid): Thrombin chemicals at least 15 days of temperature 2-8 degrees Celsius, at least 1 day of temperature of 15 degrees Celsius on the machine. Certification CE, FDA, ISO (13485)
Hau Loc General Hospital
18
Sample container used for blood clotting testing machines
7.200
Female
Reaction used on automatic coagulation system by optical measurement method. Packing: Box of 2400 cuvette (600 range x 4) Ingredients: Polystyrene plastic certification CE quality, ISO (13485)
Hau Loc General Hospital
Approval decision information
Approval date
10/09/2025
Approval decision code
Số 166/YCBG-BVHL
Approval decision file

Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register

Files with this icon are not supported by the public procurement system for direct download in normal mode. Visit DauThau.info and select Quick Download mode to download the file if you do not use Windows with Agent. DauThau.info supports downloading on most modern browsers and devices!
In case it is discovered that the BMT does not fully attach the E-HSMT file and design documents, the contractor is requested to immediately notify the Investor or the Authorized Person at the address specified in Chapter II-Data Table in E- Application form and report to the Procurement News hotline: 02437.686.611
Utilities for you
Follow quote requests
The Track Request for Quotation function helps you quickly and promptly receive email notifications of changes to Request for Quotation "Supply chemicals for testing". Our software will track the requests for quotations that you have registered for you. When there is any change, it will immediately send you an email notification.
Receive similar quote requests via email
To be one of the first to receive similar Requests for Quotations by email: "Supply chemicals for testing" as soon as they are published, subscribe to DauThau.info's VIP 8 package.
Views: 3

Select columns to display


You did not use the site, Click here to remain logged. Timeout: 60 second