Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Communication board for IPL skin treatment machine, Lumenis brand, model: M22 |
1 |
Female |
Communication board: - Communication between all system modules (power supply, switching module, handle, cooling system, service panel, PC display and additional modules). - Integrated logic circuits, amplifiers and converters. - Contains the main controller of the system. - Compatible with Lumenis IPL skin treatment machine, model: M22 being used at the hospital. - Warranty period: minimum 06 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
2 |
52-pin communication cable for Lumenis IPL skin treatment machine, model: M22 |
1 |
Set |
52-pin communication cable: - Communication between the screen module and the Interface on the camera body. - Compatible with Lumenis IPL skin treatment machine, model: M22 being used at the hospital. - Warranty period: minimum 06 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
3 |
Controller for image acquisition block used for dual-plane background subtraction angiography system, Philips brand, model: Allura Xper FD 20/10 |
1 |
Set |
Controller for image acquisition block: - Power supply: +12V/5.5A - Compatible with Philips dual-plane background subtraction angiography system, model: Allura Xper FD 20/10 being used at the hospital - Warranty period: minimum 06 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
4 |
Chamber part used for ASP low temperature sterilizer, model: Sterrad 100S |
1 |
Set |
Chamber part: - Compatible with ASP low temperature sterilizer, model: Sterrad 100S being used at the hospital. - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
5 |
Olympus image processor repair service, model: CV-170 |
1 |
Package |
Image processor repair service: - Replace the following components according to the manufacturer's standards: + Video cable connection part + Control panel + Scope connection port + Front base + Power button set + Gasket - After replacing the above components, the image processor operates normally. - Warranty period: minimum 06 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
6 |
Cassette holder for MicroTec microtome, model: CUT 4060 |
1 |
Female |
Cassette clamp head: - Compatible with MicroTec microscopic cutter, model: CUT 4060 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
7 |
Knife clamp base for MicroTec micro cutter, model: CUT 4060 |
4 |
Female |
Knife clamp base: - Compatible with MicroTec micro cutter, model: CUT 4060 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
8 |
Knife clamp plate for MicroTec micro cutter, model: CUT 4060 |
4 |
Female |
Knife clamp plate: - Compatible with MicroTec micro cutter, model: CUT 4060 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
9 |
Water supply float of Getinge autoclave, model: GSS67H/HS66 |
1 |
Female |
Water supply float of the autoclave: - Compatible with Getinge autoclave, model: GSS67H/HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
10 |
Boiler gasket, resistor used for Getinge autoclave machine model: GSS67H/HS66 |
4 |
Set |
Boiler gaskets and resistors used for autoclave machines: - Compatible with Getinge autoclave machines, model: GSS67H/HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
11 |
Pressure monitoring sensor for Getinge autoclave sterilization chamber, model: GSS67H/HS66 |
1 |
Female |
Pressure monitoring sensor for autoclave sterilization chamber: - Used to measure autoclave chamber pressure, measuring range: 0-5bar - Compatible with Getinge autoclave, model: GSS67H/HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
12 |
Air filter used for Getinge autoclave, model: GSS67H/HS66 |
2 |
Set |
Air filter for autoclave: - Compatible with Getinge autoclave, model: HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
13 |
Getinge steam sterilizer boiler safety valve, model: GSS67H/HS66 |
1 |
Female |
Steam sterilizer boiler safety valve: - Function: adjusts pressure when overpressure - Material: stainless steel - Working pressure: 3.5 bar - Compatible with Getinge autoclave, model: GSS67H/HS66 being used at the hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
14 |
Control/protection role for Getinge steamer boiler water supply pump, model: HS66/GSS 67H |
2 |
Female |
Control/protection role for water supply pump for autoclave boiler: - Compatible with Getinge autoclave, model: HS66/GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
15 |
Large piston valve used for Getinge autoclave, model: GSS67H/HS66 |
1 |
Female |
Large piston valve used for autoclave machines: - Function: used to shut off liquid/pressure through pipelines controlled by compressed air - Compatible with Getinge autoclave machines, model: GSS67H/HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
16 |
Resistors used for Getinge autoclave, model: GSS67H |
3 |
Female |
Resistors used for the autoclave: - Voltage: 380V to 415V, 50Hz - Power: 10KW - Compatible with Getinge autoclave, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
17 |
Control monitoring module for Getinge autoclave, model: GSS67H |
1 |
Female |
Control monitoring module used for autoclave: - Compatible with Getinge autoclave, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
18 |
Gasket for FCV12 exhaust valve set for Getinge autoclave, model: GSS67H |
1 |
Female |
Gasket for FCV12 exhaust valve set used for autoclave: - Compatible with Getinge autoclave, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
19 |
Exhaust valve controller for Getinge autoclave, model: GSS67H |
1 |
Set |
Exhaust valve controller for autoclave machine: - Adjusts chamber pressure and controls steam flow from the chamber to the vacuum pump - Compatible with Getinge autoclave machine, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
20 |
Door gasket used for Getinge autoclave, model: GSS67H |
4 |
Female |
Door gasket used for autoclave machine: - Material: Silicone - Compatible with Getinge autoclave machine, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
21 |
Resistors used for Getinge autoclave, model: GSS67H |
2 |
Female |
Resistors used for the autoclave: - Voltage: 380V to 415V, 50Hz - Power: 10KW - Compatible with Getinge autoclave, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
22 |
Pneumatic pilot valve (10 modules) for Getinge autoclave, model: GSS67H |
1 |
Female |
Pilot valve for pneumatic control (10 modules) for autoclave: - Compatible with Getinge autoclave, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
23 |
Control/protection role for Getinge steamer vacuum pump, model: GSS67H |
1 |
Female |
Control/protection role for autoclave vacuum pump: - Compatible with Getinge autoclave, model: GSS67H being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
24 |
Boiler pressure monitoring sensor of Getinge steamer, model: GSS67H |
1 |
Female |
Sensor to monitor boiler pressure of autoclave machine: - Sensor type PT100, monitors boiler pressure/autoclave chamber pressure/outer shell pressure - Compatible with Getinge autoclave machine, model: GSS67H being used at the hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
25 |
Resistors used for Getinge autoclave, model: HS66 |
1 |
Female |
Resistors used for the autoclave: - Voltage: 380V to 415V, 50Hz - Power: 9.7KW - Compatible with Getinge autoclave, model: HS66 in use at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
26 |
Getinge autoclave door seal pressure switch, model: HS66 |
1 |
Female |
Autoclave machine door seal pressure switch: - Compatible with Getinge autoclave machine, model: HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
27 |
Getinge steam sterilizer boiler pressure switch, model: HS66 |
1 |
Female |
Autoclave boiler pressure switch: - Compatible with Getinge autoclave, model: HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
28 |
Relay controls the boiler water level signal/autoclave door gasket pressure of Getinge brand, model: HS66 |
3 |
Female |
Relay controls the boiler water level signal / controls the door gasket pressure signal: - Compatible with Getinge autoclave, model: HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
29 |
Relay controls water pumping time for steam generation chamber of Getinge autoclave, model: HS66 |
3 |
Female |
Relay controls water pumping time for steam generation chamber: - Compatible with Getinge autoclave, model: HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
30 |
Relay controls/protects vacuum pump for Getinge autoclave, model: HS66 |
1 |
Female |
Vacuum pump control/protection relay: - Compatible with Getinge autoclave, model: HS66 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
31 |
Overheating protector used for autoclave, model: HS66 |
1 |
Female |
Overheat protector used for autoclave: - Material: stainless steel - Overheat protection at 171°C - Compatible with Getinge autoclave, model: HS66 used at the hospital. - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
32 |
Cylinder opens and closes the engine room door used in Getinge autoclave, model: HS66 |
1 |
Female |
Cylinder opens and closes the engine room door: - Compatible with Getinge autoclave, model: HS66 being used at the hospital. - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
33 |
Cylinder opens and closes the engine room door used in Getinge autoclave, model: HS66 |
2 |
Female |
Cylinder opens and closes the engine room door: - Compatible with Getinge autoclave, model: HS66 being used at the hospital. - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
34 |
Pressure relay, used to control pressure for Getinge autoclave, model: HS66 |
1 |
Female |
Pressure relay, used to control pressure for autoclave machines: - Compatible with Getinge autoclave machines, model: HS66 being used at the Hospital. - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
35 |
Getinge washer and disinfectant machine door gasket, model: S8668 |
2 |
Female |
Disinfectant washer door gasket: - Compatible with Getinge disinfectant washer, model: S8668 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
36 |
Drying fan for Getinge washing machine dryer, model: S8668 |
2 |
Female |
Drying fan for the drying part of the washing machine: - Compatible with Getinge disinfectant washing machine, model: S8668 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
37 |
Washing chamber pressure sensor for Getinge washing machine, model: S8668 |
2 |
Female |
Washing chamber pressure sensor of the washing machine: - Compatible with Getinge disinfectant washing machine, model: S8668 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
38 |
Door opening and closing lock used for Getinge tool dryer, model S-363 |
1 |
Female |
Door opening and closing lock of the tool dryer: - Compatible with Getinge tool dryer, model: S-363 being used at the Hospital - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
|||
39 |
Air filter used for Getinge tool dryer, model: S-363 |
1 |
Female |
Air filter of tool dryer: - Compatible with Getinge tool dryer, model: S-363 being used at the hospital. - Warranty period: minimum 03 months from the date of signing the acceptance record. |
Ho Chi Minh City University of Medicine and Pharmacy |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
[VIDEO] Guide for Bid Solicitors to Extend the Prequalification Document Submission Date for PPP Projects
Similar goods purchased by Investor University Medical Center:
No similar goods purchased by the %s were found.
Similar goods purchased by other Investor excluding University Medical Center:
No similar goods have been found that other %s have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.