| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
Chemical solution used to clean on automatic blood clotting system |
5.000 |
ML |
Cleaning solutions for use in automated blood processing systems. – Minimum composition containing 100 mmol/L of hydrochloric acid. – Must meet ISO 13485, CE, or FDA quality standards. – Origin: G7 or EU. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
2 |
Chemicals for cleaning and infection on automatic coagulation system |
1.200 |
ML |
Liquid cleaning and disinfection solution for automated blood processing systems. – Minimum composition containing sodium hypochlorite solution. – ISO 13485, CE, or FDA quality certification. – Origin: G7 or EU. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
3 |
Chemical solution used to wash on automatic coagulation analysis system |
300.000 |
ML |
Liquid chemical used for cleaning in automated coagulation analysis systems. – Minimum composition containing 2-Methyl-4-isothiazolin-3-one hydrochloride (MIT HCl). – Quality certifications such as ISO 13485, CE, or FDA. – Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
4 |
Reacting on automatic blood clotting system |
60.000 |
Cuvette |
- Disposable cuvette for use with automated blood coagulation systems using photometric measurement, plastic material, 4 cuvettes per strip. - CE, ISO (13485) quality certification. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
5 |
Chemicals measuring time APTT for blood clotting analysts |
595 |
ML |
- Reagents used for APTT clotting time testing are packaged with Calcium Chloride and must be used on a blood coagulation analyzer. - The minimum composition includes silica gel, synthetic phospholipid, buffer, and preservative. - Must have ISO 13485, CE, or FDA certification. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
6 |
Chemicals measuring time pt time for blood clotting analyzer |
1.000 |
ML |
- Reagents for determining prothrombin time (PT) and quantifying fibrinogen in human plasma on an automated coagulation analyzer. - Reagents with an average ISI sensitivity of 1.0. - Minimum linearity range for Fibrinogen is 60 - 700 mg/dL. - ISO 13485, CE, or FDA quality certification. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
7 |
Chemicals used for quantitative fibrinogen testing, according to Clauss method on blood clotting analysts |
280 |
ML |
- Reagent used for quantitative fibrinogen Clauss assay. - Minimum components include: bovine origin thrombin. - Quality certifications: ISO 13485, CE, or FDA. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
8 |
Standard standard abnormal levels are used for tests on blood clotting analysts |
90 |
ML |
- Chemicals used for calibration in coagulation tests such as PT, APTT, TT, Fibrinogen, Antithrombin, Protein S, Protein C, and Hepatocomplex, with abnormal low ranges. - ISO 13485 quality certification, CE marking. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
9 |
High standard abnormal levels used for tests on blood clotting analyzes |
90 |
ML |
- Reagents used for calibrating coagulation tests such as PT, APTT, and Hepatocomplex at high abnormal ranges. - Minimum composition containing human plasma. - ISO 13485, CE quality certification. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
10 |
The normal standard test substance is used for tests on blood clotting analysts |
90 |
ML |
- Chemicals used for calibration in coagulation tests such as PT, APTT, TT, Fibrinogen, various clotting factors, Von Willebrand factor, Antithrombin, Plasminogen, Plasmin Inhibitor, Protein S, Protein C, and the Hepatocomplex within normal ranges. - ISO 13485 certification, CE marking. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
11 |
Chemicals used to dilute on blood clotting analysis system |
500 |
ML |
- Chemicals used to dilute control samples in blood coagulation testing on automated analyzers. - Must contain a minimum of sodium chloride and sodium azide. - Must have ISO 13485, CE, or FDA quality certification. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
12 |
The standard substance used for tests on blood clotting analyzes |
50 |
ML |
- Chemicals used for calibrating coagulation tests such as PT (Prothrombin Time) and Fibrinogen. - Minimum components: must contain human plasma. - Quality certifications: ISO 13485, CE, or FDA. - Origin: G7 or EU. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
13 |
Chemicals used for quantitative D-dimer testing. |
64 |
ML |
Reagents used for quantitative D-dimer testing using immunoturbidimetric methods, performed on coagulation analyzers, to rule out the possibility of venous thromboembolism (VTE). Minimum sensitivity of 99.99%, average specificity of 40%. - Reagents include buffer (or diluent) and standard. - Quality certification: ISO (13485), CE. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
14 |
The standard substance used for quantifying D-dimer. |
10 |
ML |
- The chemicals used for calibrating quantitative D-dimer assays include two threshold concentrations and an abnormal concentration, performed on a coagulation analyzer. - The minimum component containing D-dimer originates from human fibrin. - Quality certifications: ISO (13485), CE. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Automated blood coagulation testing reagents. The automated blood coagulation analyzer performs multi-wavelength photometric measurements and can conduct at least 110 PT/APTT tests per hour. Consumable reagent supplies are included. Regular maintenance and servicing are provided to ensure that the equipment functions properly throughout its lifespan, eliminating any unexpected costs after selecting a vendor. |
|
15 |
Dilute solution for hematological tests |
4.000 |
Liter |
- Diluted solution (isotonic buffer), used in conjunction with a lysis agent for cell counting and sizing on an automated blood analysis system. - Minimum components: Imidazole, cyanide-free. - ISO (13485) and FDA quality certifications. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Hematology testing reagents. The automated hematology analyzer utilizes laser, photometric, impedance, and power measurement technology, capable of performing ≥100 tests per hour and analyzing a minimum of 5 white blood cell components. Consumable chemical supplies are included. Regular maintenance and servicing are provided to ensure that no additional costs arise after the results are obtained, allowing for selection of a contractor. |
|
16 |
Solution solution for hematological tests |
80 |
Liter |
- A solution containing red blood cell lysis agents for quantitative hemoglobin testing, white blood cell counting, sizing, and optical measurement on hematology analyzers. – Minimum components: including Saponin, other detergents, and quaternary ammonium salts. – ISO (13485) and FDA quality certifications. – Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Hematology testing reagents. The automated hematology analyzer utilizes laser, photometric, impedance, and power measurement technology, capable of performing ≥100 tests per hour and analyzing a minimum of 5 white blood cell components. Consumable chemical supplies are included. Regular maintenance and servicing are provided to ensure that no additional costs arise after the results are obtained, allowing for selection of a contractor. |
|
17 |
Washing solution for hematological analysts |
150 |
Liter |
- The cleaning solution is used to clean components that come into contact with blood samples in the automated cell analysis system. - Composition: A solution containing protein-digesting enzymes, free of azide and formaldehyde. - ISO (13485) and FDA quality certifications. - Origin: G7 or EU. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Hematology testing reagents. The automated hematology analyzer utilizes laser, photometric, impedance, and power measurement technology, capable of performing ≥100 tests per hour and analyzing a minimum of 5 white blood cell components. Consumable chemical supplies are included. Regular maintenance and servicing are provided to ensure that no additional costs arise after the results are obtained, allowing for selection of a contractor. |
|
18 |
Chemicals used for sample preparation (lysis of red blood cells and protection of white blood cells) |
88.000 |
ML |
- Red blood cell lysis solution and white blood cell stabilization kit for performing a complete white blood cell count analysis (minimum of 5 components). - Components: red blood cell lysis solution and white blood cell stabilization solution, containing formic acid and sodium carbonate. - ISO (13485) and FDA quality certifications. - Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Hematology testing reagents. The automated hematology analyzer utilizes laser, photometric, impedance, and power measurement technology, capable of performing ≥100 tests per hour and analyzing a minimum of 5 white blood cell components. Consumable chemical supplies are included. Regular maintenance and servicing are provided to ensure that no additional costs arise after the results are obtained, allowing for selection of a contractor. |
|
19 |
Standard substances used on hematological analysts |
315 |
ML |
- Calibration standards are used to monitor the performance of automated hematology analyzers.
- Minimum components: contain stabilized human red blood cells in isotonic solution.
- ISO (13485) and FDA quality certifications.
- Origin: G7 or EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Hematology testing reagents. The automated hematology analyzer utilizes laser, photometric, impedance, and power measurement technology, capable of performing ≥100 tests per hour and analyzing a minimum of 5 white blood cell components. Consumable chemical supplies are included. Regular maintenance and servicing are provided to ensure that no additional costs arise after the results are obtained, allowing for selection of a contractor. |
|
20 |
Electrodes and calibrators for quantitative blood gas testing |
4.500 |
kiểm TRA |
The chemical/sample analysis kit contains all the necessary components for measuring and analyzing samples, including sample collection tubes, sensors (electrodes), calibration solutions, as well as electronic and liquid components required for analyzing patient and quality control (QC) samples, as well as calibrating the instrument. It can measure the following parameters: pH, pO2, pCO2, Na+, K+, Ca++, Cl-, glucose, lactate, total hemoglobin, oxyhemoglobin, deoxyhemoglobin, methemoglobin, carboxyhemoglobin, and bilirubin. The calibration solutions in the measurement kit are used to calibrate all the parameters: pH, pO2, pCO2, Na+, K+, Ca++, Cl-, glucose, lactate, total hemoglobin, and bilirubin. The integrated sample collection tube has a hands-free suction function. The measurement kit does not require maintenance, separate electrodes, reagents, or gas cylinders. Installation time for the measurement kit: < 25 minutes. Each cartridge is stable for ≥ 28 days when installed on the system. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
This blood gas analyzer is a quantitative device that measures 15 parameters of blood gases, electrolytes, and biochemistry. It uses cartridge technology. The device has an automatic sample collection function. Results are available within 60 seconds. Cartridge box capacity: 100/300/400 tests, ensuring no additional costs after results are obtained when selecting a vendor. |
|
21 |
Blood gas testing machine cleaning solution |
72 |
Set |
The waste container/sink contains cleaning solutions used to clean sample lines after each analysis and calibration procedure. It also contains gases (oxygen, carbon dioxide, nitrogen), salts (alkali halides), surfactants, and preservatives. The waste container/sink is also designed to hold liquid waste; all liquid waste contained within the container must be completely sealed to ensure safe and convenient disposal. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
This blood gas analyzer is a quantitative device that measures 15 parameters of blood gases, electrolytes, and biochemistry. It uses cartridge technology. The device has an automatic sample collection function. Results are available within 60 seconds. Cartridge box capacity: 100/300/400 tests, ensuring no additional costs after results are obtained when selecting a vendor. |
|
22 |
Blood gas test control materials |
18 |
Box |
Contains quality control (QC) solutions along with the necessary electronic, mechanical, and liquid handling components for analyzing QC samples. Must include at least three separate QC levels, and these levels must be verified to perform measurements across a range of clinical values for all parameters. The AQC system is independent of the measurement system. QC can be automated or performed manually (if needed). Eliminates large variations in results due to air exposure. Does not accept manual QC data. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
This blood gas analyzer is a quantitative device that measures 15 parameters of blood gases, electrolytes, and biochemistry. It uses cartridge technology. The device has an automatic sample collection function. Results are available within 60 seconds. Cartridge box capacity: 100/300/400 tests, ensuring no additional costs after results are obtained when selecting a vendor. |
|
23 |
Aortic blood syringe |
4.500 |
Female |
This 1cc arterial blood gas injection syringe contains a balanced lithium heparin and calcium formulation in a sprayable form, with a concentration of approximately 30 IU (~50 IU/mL). The product is a sterile, single-use medical device made from polypropylene (PP) material, and includes a protective cap. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
This blood gas analyzer is a quantitative device that measures 15 parameters of blood gases, electrolytes, and biochemistry. It uses cartridge technology. The device has an automatic sample collection function. Results are available within 60 seconds. Cartridge box capacity: 100/300/400 tests, ensuring no additional costs after results are obtained when selecting a vendor. |
|
24 |
The quantitative test of electrolytes (k, na, cl, ca, pH) |
34.000 |
ML |
Multi-parameter electrolyte quantification reagent (K, Na, Cl, Ca, pH). – Main components: KCl, NaCl, NaAc, CaCl2, pH buffer, surfactants, preservatives. - Concentration: Ammonium molybdate ≤ 0.4 mmol/L Sulphuric acid ≥ 100 mmol/L Hydrochloric acid ≥ 100 mmol/L - Calibration values: Calibration A: K+ ≥ 4 mmol/L, Na+ ≥ 140 mmol/L, Cl- ≥ 100 mmol/L, Ca2+ ≥ 1.25 mmol/L, pH ≥ 7.4 Calibration B: K+ ≥ 8 mmol/L, Na+ ≥ 110 mmol/L, Cl- ≥ 70 mmol/L, Ca2+ ≥ 2.5 mmol/L, pH ≥ 7 - Linear error D: K+ ≤3%, Na ≤1%, Cl- ≤2%, Ca2+ ≤5% Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Reagents for automatic electrolyte analyzers. Automatic sample collection system. ≥ 65 tests/hour capacity, with barcode scanner and integrated scanning function. Types of samples: whole blood, serum, plasma, urine – ensuring no additional costs after results are obtained; vendor selection. |
|
25 |
Quantitative testing quality control materials (K, Na, Cl, Ca, pH) |
200 |
ML |
Main components: KCl, NaCl, NaAc, CaCl2, LiCl, pH buffer, surfactants, preservatives. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Reagents for automatic electrolyte analyzers. Automatic sample collection system. ≥ 65 tests/hour capacity, with barcode scanner and integrated scanning function. Types of samples: whole blood, serum, plasma, urine – ensuring no additional costs after results are obtained; vendor selection. |
|
26 |
IVD is a cleaning solution used for electrolyte testing machines |
600 |
ML |
Main components: Sodium hypochlorite (NaClO) 0.4% - 0.5% Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Reagents for automatic electrolyte analyzers. Automatic sample collection system. ≥ 65 tests/hour capacity, with barcode scanner and integrated scanning function. Types of samples: whole blood, serum, plasma, urine – ensuring no additional costs after results are obtained; vendor selection. |
|
27 |
IVD is Na/K/Cl/Ca/pH electrode charging solution |
20 |
ML |
Reagent solutions for Na/K/Cl/Ca/pH: Main components include KCl, NaCl, NaAc, CaCl2, LiCl, pH buffer, surfactants, and preservatives. pH ≥ 7.6 Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Reagents for automatic electrolyte analyzers. Automatic sample collection system. ≥ 65 tests/hour capacity, with barcode scanner and integrated scanning function. Types of samples: whole blood, serum, plasma, urine – ensuring no additional costs after results are obtained; vendor selection. |
|
28 |
IVD is the reference electrode loading solution |
20 |
Jar |
Main components: KCl The product originates from G7 countries. Quality standard: ISO 13485:2016 Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
Reagents for automatic electrolyte analyzers. Automatic sample collection system. ≥ 65 tests/hour capacity, with barcode scanner and integrated scanning function. Types of samples: whole blood, serum, plasma, urine – ensuring no additional costs after results are obtained; vendor selection. |
|
29 |
Chromatography |
12.000 |
kiểm TRA |
Used to determine HbA1c (Hemoglobin A1c) in whole blood samples. Composition: Hydrophilic polymer of methacrylate ester copolymers. Includes a pre-filter – Meets ISO 13485 standard. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
30 |
The 1st chromatography solution |
36.000 |
ML |
Used to determine Hemoglobin A1c (HbA1c) in whole blood samples – after pre-extraction from area A0 and stabilization of the chromatography column. Composition: Sodium perchlorate, Sodium azide - Meets ISO 13485 standards. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
31 |
2nd chromatography solution |
12.000 |
ML |
Used to determine Hemoglobin A1c (HbA1c) in whole blood samples – after washing region A0 and identifying Hb variants (HbC).
Composition: Sodium perchlorate, phosphate, sodium azide.
ISO 13485 standard.
Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
32 |
Chromatographic solution for variant HB |
31.200 |
ML |
Used to determine Hemoglobin A1c (HbA1c) in whole blood samples – after washing region A0 and identifying Hb variants (e.g., HbS).
Components: Phosphate, sodium perchlorate, sodium azide. - Meets ISO 13485 standard. - Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
33 |
Hemoglobin A1c/HPLC testing solution / red blood cell lysis buffer |
114.000 |
ML |
Used to determine Hemoglobin A1C (HbA1C) in whole blood samples. Used to dilute whole blood samples and clean the tubing through which the sample flows.
Ingredients: 2-Phenoxyethanol; Sodium azide.
ISO 13485 standard. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
34 |
Diluted in-house HbA1c control solution for use with high-performance liquid chromatography (HPLC) systems. |
750 |
ML |
Used to determine Hemoglobin A1c (HbA1c) in whole blood samples. Used to dissolve, dilute, and prepare control solutions and whole blood samples. Ingredients: 2-Phenoxyethanol; Polyoxyethylated Octyl phenol; ISO 13485 standard. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
35 |
Reference standard for HbA1c on a high-performance liquid chromatography (HPLC) system |
108 |
ML |
Used to create a standard curve for HbA1c measurement.
Components: Calibrator 90 Diluent, - 2-Phenoxyethanol; - Polyoxyethylated Octyl phenol; Calibrator 90 High & Low, - Human source hemoglobin. Meets ISO 13485 standards. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
36 |
In-house testing of HbA1c using a high-performance liquid chromatography (HPLC) system. |
20 |
ML |
Utilize quality management to monitor accuracy and precision in the HbA1c quantification process. Meets ISO 13485 standards. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
High-Performance Liquid Chromatography (HPLC) HbA1c testing device. The HbA1c system is fully automated. Capacity: ≥ 60 tests/hour. CV < 1%; Automatic sample shaking, automatic barcode scanning, ensuring that no additional costs are incurred after results are obtained when selecting a vendor. Origin: G7 |
|
37 |
Sample red blood cells |
380 |
ML |
- The Hồng cầu mẫu is used to determine the ABO blood group in reverse direction using gel technology. - Minimum components: includes a 0.8% ready-to-use solution derived from human red blood cells belonging to A1, B blood groups; the cells are suspended in a buffered and preserved solution (neomycin, chloramphenicol). - Quality certification: CE, ISO (13485). - Origin: EU. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
REAGENTS SUITABLE FOR BLOOD GROUPING AND COAGGULATION TESTS |
|
38 |
Gelcard Coombs directly, perform blood type harmony at 37 degrees Celsius |
1.500 |
Card |
- Gel cards ≥ 8 wells, used for direct and indirect immunoglobulin testing on human blood samples using gel technology. These tests include screening and identification of abnormal antibodies, cross-reactivity detection, self-assessment, and cell type classification.
- Minimum components: low ionic strength LISS (Lysis Inhibition Solution) containing human immunoglobulin; a mixture of multi-line IgG and single-line C3d antibody.
- Storage: 2 to 25°C.
- Quality certifications: CE, ISO (13485).
- Origin: EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
REAGENTS SUITABLE FOR BLOOD GROUPING AND COAGGULATION TESTS |
|
39 |
Gelcard is determined to be blood type by sample red blood cell method, performing blood type harmony at 22 degrees Celsius |
1.500 |
Card |
- Gel cards ≥ 8 wells, suitable for tests in salt and enzyme environments, while also serving as control wells in gel electrophoresis. The following techniques can be performed using these gel cards: screening and identification of abnormal antibodies, cross-reactivity testing, self-control, red blood cell typing, and ABO group determination (reverse). - Minimum components: includes a buffer solution without antibodies. - Storage: 2 to 25°C. - Quality certifications: CE, ISO (13485). - Origin: EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
REAGENTS SUITABLE FOR BLOOD GROUPING AND COAGGULATION TESTS |
|
40 |
Gelcard intends to type ABO/RH with two methods of serum and sample red blood cells |
5.200 |
Card |
- Gel card ≥ 8 wells, ≥ 1 test/card, used to determine ABO and Rh (D) antigens, as well as the reverse ABO blood group in a gel format. - Minimum components include: Anti A; Anti B; Anti AB; Anti D with no ability to detect the D variant; Anti D with the ability to detect the D variant; control wells (buffer solution without antibodies); buffer solution without antibodies (for reverse ABO testing). - Sensitivity: ≥ 99.5%, Specificity: 100%. - Storage: 2-8°C. - Quality certifications: CE, ISO (13485). - Origin: EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
REAGENTS SUITABLE FOR BLOOD GROUPING AND COAGGULATION TESTS |
|
41 |
The patient's red blood cell dilute is automatically type blood types |
7.800 |
ML |
- Test solution for preparing cell suspension and diluted blood/plasma solutions used in gel preparation techniques. – Minimum components: including glycine and glucose; chloramphenicol and neomycin sulfate as preservatives. – Storage: 2 to 8°C. – Packaging: 200 mL (or equivalent). – Quality certifications: CE, ISO (13485). – Origin: EU. |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
REAGENTS SUITABLE FOR BLOOD GROUPING AND COAGGULATION TESTS |
|
42 |
The erythrocyte kit of abnormal antibody screening samples |
480 |
ML |
- The pink culture is used for filtering out abnormal antibodies using the gel technique. - Minimum components: contains 0.8% ready-to-use mixture of pink blood cells from group O donors, produced by a single donor per vial. The cells are suspended in a stabilizing solution. - Storage: 2 to 8°C. - Packaging: 30 mL (or equivalent). - Quality certifications: CE, ISO (13485). - Origin: EU |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
REAGENTS SUITABLE FOR BLOOD GROUPING AND COAGGULATION TESTS |
|
43 |
Standard red blood cell set |
360 |
ML |
- The control material is used to enable regular testing of materials, work processes, and equipment in order to determine the ABO blood group antigen system, the Rhesus system, and the K system, identify appropriate ABO blood group antibodies, and detect abnormal antibodies using both immunoglobuline and enzyme assays, as well as ABO blood group compatibility testing. - Minimum components: human red blood cells (hematocrit) in isotonic saline solution, with a preservative (neomycin, chloramphenicol), and sodium azide-containing antibodies. - Packaging: 24 mL (or equivalent). - Quality certifications: CE, ISO (13485). |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
REAGENTS SUITABLE FOR BLOOD GROUPING AND COAGGULATION TESTS |
|
44 |
The Real-time PCR test kit quantifies the HIV virus (including standard, positive and internal evidence) |
1.056 |
kiểm TRA |
*Reverse transcription and quantitative nucleic acid amplification assay to detect and quantify RNA of the human immunodeficiency virus type 1 (HIV-1) in extracted RNA samples from clinical specimens. The test can detect HIV-1 RNA belonging to groups M, O, N, and CRF01-AE, CRF02-AG, and CRF03-AB. * Components: HIV1 Mix HIV1 Standard: HIV1 Positive Control, HIV1 Internal Control. * LoD: 60 IU/mL (26 copies/mL) with plasma samples * Specificity: 99.5% * Includes: HIV PCR Mix RT EnzymeMix HIV1 Q - PCR Standard 10^5 HIV1 Q - PCR Standard 10^4 HIV1 Q - PCR Standard 10^3 HIV1 Q - PCR Standard 10^2 HIV1 - ELITe Positive Control HIV1 CPE *Includes CPE positive control (already included in the kit) Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
1. Real-time PCR diagnostic and monitoring kits for detecting and tracking bloodborne viruses (Hepatitis B virus and HIV). |
|
45 |
The Real-time PCR test kit quantifies hepatitis B virus (including standard substances, positive and internal evidence) |
960 |
kiểm TRA |
* A nucleic acid amplification test to detect and quantify the DNA of Hepatitis B Virus (HBV) extracted from patient samples. The test can detect HBV belonging to genotypes A, B, C, D, E, F, G, H, I, and RF. * Components: HBV Mix, HBV Standard, HBV Positive Control, HBV Internal Control
* LoD: 9 IU/mL (38 copies/mL) of serum or plasma samples
* Specificity: 97.6%
* Includes: HBV PCR Mix, HBV Q - PCR Standard 10^5, HBV Q - PCR Standard 10^4, HBV Q - PCR Standard 10^3, HBV Q - PCR Standard 10^2, HBV - ELITe Positive Control, HBV CPE
* Uses: CPE control (included in the kit)
* Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
1. Real-time PCR diagnostic and monitoring kits for detecting and tracking bloodborne viruses (Hepatitis B virus and HIV). |
|
46 |
The Real-time PCR test sets to qualitative diagnosis and type of HPV virus with high risk: 16, 18, 31, 45; HR1 (33, 52, 58); HR2 (35, 39, 51, 56, 59, 66 and 68). |
384 |
kiểm TRA |
* Real-time nucleic acid amplification test for the detection and typing of 14 high-risk types of human papillomavirus (HPV): Detection and typing of high-risk HPV types 16, 18, 31, 45; Detection of HR1 high-risk HPV group (33, 52, 58); Detection of HR2 high-risk HPV groups and non-vaccine types (35, 39, 51, 56, 59, 66, and 68). * Components: HPV PLUS PCR Mix * Performance: 96.7% for HPV16–31; 88.5% for HPV; 93% for HPV HR2; 95.0% for HPV18–45. * Includes: HPV PLUS PCR Mix * The kit includes an internal control. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
2. Real-time PCR diagnostic tests for identifying sexually transmitted infections caused by pathogens. |
|
47 |
Standard checking high risk HPV virus positive |
960 |
µl |
* Positive control for quantitative nucleic acid amplification tests to detect the DNA of Human Papillomavirus (HPV) types with high risk. * Contents: HPV PLUS Positive Control * Storage duration: 15 days per use * Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
2. Real-time PCR diagnostic tests for identifying sexually transmitted infections caused by pathogens. |
|
48 |
Chemical extraction sample 600µl - 1000µl for completely molecular biological machine |
2.736 |
kiểm TRA |
Function: A ready-to-use tray containing reagents for the extraction and purification of nucleic acids (NA). Technology: An NA isolation protocol based on magnetic particles, designed for automated preparation of highly purified DNA (from humans, bacteria, viruses, and fungi) and viral RNA from human serum, plasma obtained in EDTA or citric acid, urine, nasal secretions (swabs), and respiratory samples (bronchoalveolar lavage (BAL) / Broncho Aspirate (BA)). The reagent kit is optimized for the isolation of nucleic acids from 600 µL or 1 mL samples. Compatibility: Suitable for use with fully automated molecular biology instruments. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
3. Extraction chemicals and consumables for extraction, as well as real-time PCR running on an automated molecular biology system. |
|
49 |
PCR reaction cassette for fully molecular biological machine |
3.456 |
kiểm TRA |
Function: As a consumable item, used in conjunction with real-time PCR reagents to perform real-time PCR reactions. Designed specifically as a reaction cassette. Each cassette includes a tube and a PCR lid. Compatibility: Used on fully automated molecular biology systems. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
3. Extraction chemicals and consumables for extraction, as well as real-time PCR running on an automated molecular biology system. |
|
50 |
Chemical extraction of 200 µl sample for completely molecular biological machines |
480 |
kiểm TRA |
Function: A ready-to-use tray containing chemicals for extracting and purifying nucleic acids (NA). The NA extraction technology, based on magnetic particles, is designed to automatically prepare highly pure DNA from human cells, bacteria, viruses, fungi, and parasites, as well as viral RNA from the following clinical samples: whole blood collected in EDTA or citrate, serum, plasma obtained in EDTA or citrate, urine, cerebrospinal fluid, amniotic fluid, pleural fluid, gastric aspirates (bronchoalveolar lavage/aspirate for sputum and pharyngeal secretions), nasal swabs, throat swabs, vaginal swabs, cervical swabs, mucosal swabs, rectal swabs, stool samples, blood cultures, biopsies, and gastric aspiration. Each extraction kit includes: lysis solution, PK buffer, magnetic particles, binding buffers, wash buffers, and distilled water. The procedure is optimized for isolating nucleic acids from 200 µL of sample volume. Compatibility: Specifically designed for use on fully automated molecular biology systems. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
3. Extraction chemicals and consumables for extraction, as well as real-time PCR running on an automated molecular biology system. |
|
51 |
Set of extract consumption supplies for completely automatic molecular biological machines |
3.216 |
kiểm TRA |
Function: A set of plastic consumables for extracting nucleic acids from biological samples. Components: 48 sample tubes, 4 x 12 tip cassettes, and 50 extraction tubes with 0.5 mL capacity. Compatibility: Designed for use with fully automated molecular biology systems. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
3. Extraction chemicals and consumables for extraction, as well as real-time PCR running on an automated molecular biology system. |
|
52 |
The taper tip has a 300µL type filter for the extract for completely automatic molecular biology |
5.760 |
TIP |
The tip has a 300µL filter for use with automated molecular biology extraction kits. Origin: OECD |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
3. Extraction chemicals and consumables for extraction, as well as real-time PCR running on an automated molecular biology system. |
|
53 |
2.0 mL storage vial |
5.000 |
Female |
2.0 ml sterile, threaded storage tube with lid, designed for use with automated molecular biology equipment. Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
3. Extraction chemicals and consumables for extraction, as well as real-time PCR running on an automated molecular biology system. |
|
54 |
PreservCyt preservation, transportation and antibacterial solution for gynecological specimens |
400 |
ML |
*Preservative, transport, and antiseptic solution for gynecological specimens. Used for preparing cytology slides or in HPV virus testing or sexually transmitted infection tests. * Ingredients: Methanol (35-55%) Origin: G7 |
Binh Phuoc General Hospital – National Highway 14 – Dong Xoai Ward, Dong Nai City |
. |
3. Extraction chemicals and consumables for extraction, as well as real-time PCR running on an automated molecular biology system. |
Downloading files directly on the new Public Procurement System requires a computer using Windows operating system and installing Client Agent software (Linux and MacOS operating systems cannot install Client software yet). Therefore, to be able to download files on smartphones, tablets or computers using operating systems other than Windows, you need to use DauThau.info software to download files.
To download, please Login or Register
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor Bệnh viện Đa khoa Bình Phước:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding Bệnh viện Đa khoa Bình Phước:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced:
No similar goods have been found in the bidding results of the Ministry of Health.