Contact Us
- 0904.634.288, 024.8888.4288
- [email protected]
- Facebook Fanpage: http://fb.com/dauthau.info
- Messenger: http://m.me/dauthau.info
Contact Us
| No | List of product/services | Quantity | Unit | Description | Location | Specification | Note | Feature |
|---|---|---|---|---|---|---|---|---|
1 |
7cm x5m bucket tape |
800 |
Roll |
Size: 7cm x 5m. The product is woven from 100% cotton fibers with high absorbency, no toxins. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
2 |
3 hook tape |
84 |
Roll |
Ingredients: Polyester and rubber fibers, |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
3 |
Suction cotton |
160 |
Kg |
Medical cotton made of 100% natural cotton fibers has good absorbency, softness, and no impurities. Packed tightly in PE bags |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
4 |
Non-resorbable surgical suture number 10/0 |
48 |
Fiber |
No. 10/0 ; 2 trapezoidal needles 1/2C, 6.2mm needle, silicone coated needle, 30cm long thread. Is a sterile nonabsorbable monofilament surgical thread made from polyamide 6.0 or 6.6; The smooth surface of the thread makes it easy to penetrate tissues. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
5 |
Non-absorbable surgical suture number 5/0 |
36 |
Fiber |
No. 5/0; 3/8C triangular needle, 16mm needle, silicone coated needle, 75cm long thread. Is a sterile nonabsorbable monofilament surgical thread made from polyamide 6.0 or 6.6; The smooth surface of the thread makes it easy to penetrate tissues. The thread has the characteristics of easy tying and good tension. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
6 |
Non-resorbable surgical suture number 2/0 |
48 |
Fiber |
Thread made from high-quality nylon, 75cm long, triangular needle, 3/8 curved. thread 2/0 turn of 26mm needle. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
7 |
Non-absorbable surgical suture number 5/0 |
144 |
Fiber |
The thread is made from high-quality nylon, 75cm long, with a triangular needle, 3/8 curved. index 5/0 20mm needle ring. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
8 |
Non-resorbable surgical suture number 3/0 |
240 |
Fiber |
Thread made from high-quality nylon, 75cm long, triangular needle, 3/8 curved. thread 3/0 turn of 26mm needle. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
9 |
Non-absorbable surgical suture number 4/0 |
240 |
Fiber |
Thread made from high-quality nylon, 75cm long, triangular needle, 3/8 curved. index 4/0 20mm needle ring. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
10 |
Silk tape 2.5cm x 5m |
1.152 |
Roll |
White Taffeta silk fabric, 100% cellulose acetate fiber, thread count 44x19.5 threads/cm, Zinc oxide glue without solvent applied evenly, weight of coating block 50-60 g/m2, adhesive force 1.8-5.5 N/cm. Plastic core with protective wings. Raw materials from G7 countries. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
11 |
Heparin test tube |
43.200 |
Tube |
* PP plastic test tube, size Ø13 x 75 (mm), maximum capacity 6 ml, black plastic cap. * Inside contains Lithium Heparin anticoagulant, there is a volume indicator on the tube label. * Withstands centrifugal rotation force accelerated at 6,000 rpm for 10 minutes, achieving safety, achieving tightness of test tube body and lid, and achieving sterility (with test results card from the verification unit). * Used to separate plasma for use in biochemical tests such as: Ionogram (Na+, K+, Ca2+, Cl-... minus Li+), PH, blood gas, alcohol quantification in blood. * Meets ISO 13485: 2016, CE, 2 CFS standards |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
12 |
PS 5ml plastic test tube without lid, no label |
10.800 |
Tube |
5ml PS plastic test tube without lid, no label*Dimensions Ø13 x 75 (mm) or Ø12 x 75 (mm), clear white PS plastic, no lid, no label, maximum capacity 6 ml. * Neutral pH, high smoothness. * Meets ISO 13485: 2016 or equivalent standards |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
13 |
1 -time acupuncture needle |
150.000 |
Female |
Disposable sterile acupuncture needles are spirally coiled, made of medical steel wire, and have a uniform color. The needle body is made from break-resistant, corrosion-resistant stainless steel, with no cracks, breaks or separation into layers. The hardness of the needle is 450-650 HV (according to the Vicker hardness scale), corresponding to a diameter of 0.3 |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
14 |
ELECTRIC PAPER 3 NEED |
400 |
Roll |
Used for ECG machine 3, size: 63mm x 30m. Achieved ISO 13485, CE. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
15 |
Surgery only number 3/0 |
144 |
Fiber |
No. 3/0 1/2C round needle, 26mm needle, silicone coated needle, 75cm long thread. A type of sterilized, biodegradable synthetic surgical thread using Polyglactin 910, composed of 90% Glycolide and 10% L-lactide. The thread will lose about 50% tension after 21 days of implantation, graft and completely dissolve in 56 to 71 days. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
16 |
Surgical suture number 4/0 |
96 |
Fiber |
No. 4/0 1/2C round needle, 22mm needle, silicone coated needle, 75cm long thread. A type of sterilized, biodegradable synthetic surgical thread using Polyglactin 910, composed of 90% Glycolide and 10% L-lactide. The thread will lose about 50% tension after 21 days of implantation, graft and completely dissolve in 56 to 71 days. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
17 |
High level disinfection solution |
12 |
Can |
High-level disinfectant solution for medical instruments, surgical instruments, endoscopic instruments, non-heat-resistant medical instruments - Ingredients: Ortho-Phthalaldehyde 0.55% (w/w), pH buffer = 7-9. Test strip included - Effective after a minimum soaking time of 5 minutes. Reuse within 14 days. Storage time in can ≥ 75 days from the date of opening. - Does not cause tool corrosion, compatible with many types of tools and materials - Use environment does not require special ventilation. Can be used for manual and machine processing. Packaging ≥ 5 liters Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
18 |
EDTA test tube |
12.000 |
Tube |
`* PP plastic test tube, size Ø13 x 75 (mm) or Ø12 x 75 (mm), maximum capacity 6 ml, blue LPDE plastic cap. * Inside contains the anticoagulant Ethylenediaminetetraacetic Acid Dipotassium Salt Dihydrate (EDTA K2) at a standard concentration to keep cells stable in the blood, with only 1 line indicating the volume on the tube label. * Withstands centrifugal rotation force accelerated at 6,000 rpm for 10 minutes, achieving safety, achieving tightness of test tube body and lid, and achieving sterility (with test results card from the verification unit). * Meets ISO 13485: 2016, CE, 2 European CFS standards |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
19 |
Polypropylene non-consumable thread No. 7/0 |
24 |
Fiber |
Non-absorbable surgical thread is made of Polypropylene fiber, number 7/0, 60cm long, 2 needles 11mm long, 3/8 circle. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
20 |
Wire feeding numbers (number 8 to number 18) |
40 |
Female |
Manufactured from medical PVC material, 1,250 mm long. One end of the wire tube is attached to a funnel with a lid (or no lid). Sterilized by E.O gas. ISO 13485 - 2003 standard or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
21 |
Betzer catheter |
10 |
Female |
Catheter Made from natural latex, includes catheter, drainage funnel, blower funnel, washing funnel, balloon and valve. Sizes range from 12 Fr to 40 Fr. Tube length: 400 ± 10 mm. Flow rate ≥ 100 ml/min with numbers from 16Fr. Single use, sterilized with EO gas. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
22 |
Endotoxic tube of numbers |
150 |
Female |
The tube is made from high-quality medical grade PVC, non-toxic, soft and transparent with appropriate curves, transparent, soft, shiny or non-shiny. Stored separately in individual bags sterilized with EO gas. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
23 |
5ml PS plastic test tube without cap or lid |
10.000 |
Tube |
*Dimensions Ø13 x 75 (mm) or Ø12 x 75 (mm), clear white PS plastic, no cap, no label, maximum capacity 6 ml. * Neutral pH, high smoothness. * Meets ISO 13485: 2016 standards. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
24 |
Gia Ven country |
2.000 |
Liter |
Ingredients: Sodium Hypochlorite, Sodium Hydroxide, water and accessories, Clear, yellow solution Packaging: Maximum 20 liter can |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
25 |
Fast Dental X-ray was washed |
8 |
Box |
X-ray film used in dentistry, with developer bag attached to each film Film size: 30.5 x 40.5mm |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
26 |
DRASS Use 5ml |
20.000 |
Female |
5ml seamless plastic syringe, made from transparent, glossy primary medical plastic, without burrs. Clear capacity division lines. - There is a scale for maximum suction capacity up to 6ml; needle size 23G; 25G, 3-sided beveled needle tip with cap. Plunger has a groove to break to destroy, does not contain DEHP toxins. The bloody needle tip helps distinguish the needle size according to international standards and is tightly attached to the needle body to prevent leakage and is safe to use. Standard EN ISO 13485:2016 |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
27 |
Clip Polymer clamping blood vessels of sizes |
24 |
Female |
Vascular Clamps, sizes: L, ML, XL, Materials: Polymer; There is a lock. Close quickly. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
28 |
Non-woven surgical gauze (7.5cm x 7.5cm x 6 sterile layers) |
600 |
Pieces |
Gauze is made from fast absorbent non-woven fabric. Mesh fabric with holes, soft, smooth, uniform white color. No toxins. Contains no allergens, no starch, no water-soluble humus and viscera. Sealed packaging with EO gas sterilization Meets ISO 13485 or equivalent standards |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
29 |
Distilled water 2 times |
200 |
Liter |
Double distilled water Packed with maximum capacity of 10 liters/can |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
30 |
Sterile camera bag |
100 |
Female |
Ingredients include 1. Nylon tube 18 x 230 cm - 2 x 60 cm lanyards 2. 9 x 14 cm nylon bag - 2 x 30 cm lanyards Manufactured from Pe nylon, with clarity, soft and smooth surface, and toughness. No dirt, impurities, no tears, no punctures, no skin irritation... Sterilized with EO gas Meets ISO 13485:2016 or equivalent standards |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
31 |
Silicon suction cord |
5 |
Female |
A suction line is used in surgery to help drain fluid out. Sterilized, Silicone material, 3.6m long. There is a tube connecting both ends. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
32 |
Gloves |
1.000 |
Pair |
Household rubber gloves. The main ingredient is Latex rubber. Sizes M, L, XL. Length 380 mm. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
33 |
Gold -headed |
10.000 |
Female |
Yellow tapered tip, 200µl volume. Material is PP plastic, can be sterilized. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
34 |
Ultrasound gel |
12 |
Can |
Water-based lubricant gel is used in medical diagnostic ultrasound. High sound conductivity, water soluble, odorless. Does not cause skin irritation, does not contain formaldehyde. Packaging: Can ≥ 5 liters |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
35 |
Surgery only number 3/0 |
120 |
Fiber |
Polyglactin 910 multifilament synthetic absorbable suture, covered with polyglactin and Calcium stearate, number 3/0, minimum length ≥ 75cm, round needle. Needle covered with Silicone, length ≥26mm, needle curvature 1/2 circle. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
36 |
Paper to print results used in ultrasound |
200 |
Roll |
Size 110 mm x 20 m. Used for Sony and Mitsubishi printers. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
37 |
Mercury thermometer |
12 |
Female |
Mercury thermometer 42 degrees. 12 cái / hộp |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
38 |
Probiotics |
70 |
Package |
DW97H is a combination of billions of microorganisms belonging to the groups of bacteria, filamentous fungi, yeast, and actinomycetes that have been carefully isolated and selected to have a synergistic role in strongly decomposing organic substances into harmless inorganic substances such as H2O and CO2. Besides, they also strongly oppose disease-causing bacteria, making it impossible for disease-causing bacteria to survive long and grow in the water environment. In addition, the presence of DW97H in aerobic wastewater treatment systems also increases flocculation and sedimentation of activated sludge, increasing the density of useful microorganisms on biological membranes, helping to increase the efficiency of wastewater treatment systems in general and hospital wastewater in particular. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
39 |
Chlorin |
90 |
Kg |
It is a disinfectant chemical in tablet form. Weight ≤ 200g/tablet. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
40 |
Steamed box |
1 |
Female |
Box made of stainless steel. Diameter 360 mm. Has a lock and handle. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
41 |
Rubber squeeze |
5 |
Fruit |
Made of red latex rubber, high elasticity. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
42 |
AS LATEX testing chemicals |
2 |
Box |
Sensitivity: the reagent is designed to agglutinate in the presence of anti-SLO levels higher than 200 ± 50 IU/ml IU/ml. Specificity: the correlation of results with the Rantz and Randall titration method was 100% for titers lower than 166 IU/ml or higher than 250 IU/ml. Titters between these levels can give questionable results. There was no prozone phenomenon for titers ≤ 1100 IU/ml. Box ≥ 100 tests Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
43 |
Anti A |
20 |
Jar |
- Vial of monoclonal antibody A solution diluted in a phosphate buffer containing sodium chloride, EDTA and bovine albumin, used for hemagglutination test to determine blood type. - Antibody titer 1:512 - Sensitivity and specificity: 100% - Store at 2-8oC - Packaging ≥ 10 ml / Vial Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
44 |
Anti AB |
20 |
Jar |
Vial of AB monoclonal antibody solution diluted in a phosphate buffer containing sodium chloride, EDTA and bovine albumin, used for hemagglutination test to determine blood type. - Antibody titer 1:512 - Sensitivity and specificity: 100% - Store at 2-8oC - Packaging ≥ 10 ml / Vial Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
45 |
Anti b |
20 |
Jar |
- Vial of monoclonal antibody B solution diluted in a phosphate buffer containing sodium chloride, EDTA and bovine albumin, used for hemagglutination test to determine blood type. - Antibody titer 1:512 - Sensitivity and specificity: 100% - Store at 2-8oC - Packaging ≥ 10 ml / Vial Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
46 |
Quo-lab A1c Test Kit |
1.700 |
kiểm TRA |
Quantification of HbA1c in human blood. - Ingredients: + Buffer: Ammonium Chloride: 0.54%, Sodium, Deoxycholate Monohydrate: 0.40%, Sodium Azide: Appropriate amount, Water: Appropriate amount. + Conjugate: Boronate conjugate: 11μg - Compatible on Quo-Lab A1c machine - Specification: Box of ≥ 50 tests - Meets ISO 13485: 2016 standards or equivalent. |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
47 |
Test detects HIV-1 and HIV-2 antibodies |
200 |
kiểm TRA |
Sensitivity 100%, specificity ≥ 99.75%, Fast results within 15 minutes, Stability of test results up to 60 minutes, no need to use any additional buffer solution (chase) for serum and plasma blood samples. - Main content: Antibody Anti HIV-1, Antibody Anti HIV-2, Antigen (pGO9-CKS/XL-1) HIV-1 Group O, Antigen (pGO11-CKS/XL-1) HIV-1 Group O, Antigen (PjC100)HIV-2, Antigen (pOM10/PV361) HIV-1, Antigen (pTB319/XL-1)HIV-1, HIV-1 Antigen Peptide, HIV-2 Antigen Peptide. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
48 |
Quick test kit detects HIV antibodies 1 & 2 |
200 |
kiểm TRA |
Detect and differentiate antibodies (IgG, IgM, IgA) specific to HIV-1 virus including subtype O and HIV-2 in serum, plasma and whole blood samples. Sensitivity: 100%; Specificity ≥ 99.8%. Meets ISO 13485 standards |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
49 |
Rapid detection test for H.Pylori test |
400 |
kiểm TRA |
Used for rapid detection of H. pylori in clinical specimens or on culture media. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
50 |
Test HIV |
50 |
kiểm TRA |
Specimens: Serum, plasma, whole blood - Sensitivity ≥ 99.47%; Specificity ≥99.87% - Test Kit Ingredients: Recombinant HIV-Ag gold conjugate. - Anti-human IgG-Fe Mcab results line. - Included in the 2020 supplementary national HIV diagnostic testing recommendations of the National Institute of Hygiene and Hygiene Meets ISO 13485 standard or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
51 |
The test strip qualitatively detects hCG in human urine |
500 |
kiểm TRA |
Early pregnancy detection tool used for quick testing, detecting the presence of pregnancy hormone (HCG) in urine Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
52 |
Anti d |
5 |
Jar |
- Vial of monoclonal antibody D solution diluted in a phosphate buffer containing sodium chloride, EDTA and bovine albumin, used for hemagglutination test to determine blood type. - Antibody titer 1:512 - Sensitivity and specificity: 100% - Store at 2-8oC - Packaging ≥ 10 ml / Vial Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
|||
53 |
Test detects 4 addictive substances (MOP, AMP, MET, THC) |
1.000 |
kiểm TRA |
Qualitative detection of narcotic substances in urine (Morphine + Amphetamine + Methamphetamine + THC). 100% sensitivity. 100% specificity. Meets ISO 13485 standards or equivalent |
Department of Pharmacy and Medical Equipment - An Lao Medical Center |
Select columns to display
If you are still not our member, please sign up.You can use your account on DauThau.info to log in to Dauthau.Net, and vice versa!
Only 5 minutes and absolutely free! Your account can be use on all over our ecosystem, including DauThau.info and DauThau.Net.
Detailed instructions on how to deposit money and redeem points on DauThau.info
When does contract negotiation fail?
[VIDEO] Guide for bid solicitors to Extend the Bid Submission Deadline
[VIDEO] Guide to Evaluating Bid Documents on the New National Bidding Network System
[VIDEO] Guide to Posting Tender Notices for PPP Projects
[VIDEO] Guide to Posting Prequalification Notices for PPP Projects
[VIDEO] Guide to Responding to Clarification Requests for e-HSMST (E-Prequalification Invitation Documents) of PPP Projects on the New National Bidding Network System
[VIDEO] Guide to Uploading the Shortlist for PPP Projects
Similar goods purchased by Investor An Lao Medical Center:
No similar goods purchased by the Investor were found.
Similar goods purchased by other Investor excluding An Lao Medical Center:
No similar goods have been found that other Investor have purchased.
Similar goods for which the bidding results of the Ministry of Health have been announced: